• Title/Summary/Keyword: magnetic measurement

Search Result 1,264, Processing Time 0.026 seconds

3-Dimensional Dosimetry of Small Field Photon Beam (광자선의 소조사면에서의 3차원적 선량 측정)

  • Jang, Ji-Sun;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.54-61
    • /
    • 2012
  • A polymer gel dosimeter was fabricated. A 3-dimensional dosimetry experiment was performed in the small field of the photon of the cyberknife. The dosimeter was installed in a head and neck phantom. It was manufactured from the acrylic and it was used in dosimetry. By using the head and neck CT protocol of the CyberKnife system, CT images of the head and neck phantom were obtained and delivered to the treatment planning system. The irradiation to the dosimeter in the treatment planning was performed, and then, the image was obtained by using 3.0T magnetic resonance imaging (MRI) after 24 hours. The dose distribution of the phantom was analyzed by using MATLAB. The results of this measurement were compared to the results of calculation in the treatment planning. In the isodose curve on the axial direction, the dose distribution coincided with the high dose area, 0.76mm difference on 80%, rather than the low dose area, 1.29 mm difference on 40%. In this research, the fact that the polymer gel dosimeter and MRI can be applied for analyzing a small field in a 3 dimensional dosimetry was confirmed. Moreover, the feasibility of using these for the therapeutic radiation quality control was also confirmed.

Study precision attitude control of marine biological robot which utilizes a plurality of sensors (다중 센서를 이용한 해양 생체 로봇의 정밀 자세 제어 연구)

  • Kim, Min;Son, Kyung-Min;Park, Won-hyun;Kim, Gwan-Hyung;Byun, Ki-sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.548-549
    • /
    • 2015
  • 무인 잠수정은 자율 무인잠수정(이하 'AUV' 또는 '자율무인잠수정'을 혼용)과 원격조정잠수정(이하 'ROV'로 지칭)으로 분류를 할 수 있다. ROV는 테더 게이블로 인한 작업 범위의 한계와 운동성능 효율이 떨어지는 단점을 지니고 있어, 테더 케이블이 필요 없는 AUV에 대한 필요성이 증대되고 있다. 추측 항법 시스템인 관성 항법 시스템(inertial navigation system, 이하 'INS'로 지칭)은 외부 도움없이 관성측정 장치(inertial measurement unit, 이하 'IMU'로 지칭)를 활용하여 구성된 시스템을 말한다. IMU는 자이로 스코프(gyroscope), 가속도계(accelerometer), 지자기(magnetic)센서로 구성된 측정 장치로 3개의 센서를 사용하여 상호 보정을 통한 기동 체의 위치, 속도 및 자세 정보를 제공한다. 복합항법시스템은 추측항법시스템이 가지는 누적오차와 측위 항법시스템이 가지는 외부환경에 대한 단점을 상호 보완하는 방법으로 연구가 진행 중이다. 하지만 심해서 또는 해양의 특성에 따라 측위 시스템이 사용되지 못하기 때문에 추측 항법시스템의 다양한 관성 센서를 활용한 상로 보완과 신호처리 방법을 통한 연구 개발이 진행 중이다. 다양한 센서 정보를 통합하는 목적으로 칼만 필터와 같은 최적 필터기법이 보편적으로 사용되고 있다. 칼만 필터는 확률 선형 시스템에 대하여 공정잡음 및 측정 잡음이 가우시안 확률 분포를 따를 때 최적의 추정자가 된다. 또한 가우시안 조건을 만족하지 않는 경우에도 선형 추정자 중에 추정 오차의 분산이 가장 작은 추정자이다. 칼만 필터가 최상의 성능을 발휘 하려면 공정잡음과 측정 잡음의 실제 값을 정확히 알아내는 것이 중요하다. 잡음 수준에 대한 정보가 부정확 할 경우 칼만 필터는 발산 할 수 있기 때문에 시스템에서 잡음 수준의 공산은 칼만 필터의 최적 이득을 결정하는 중요한 요소로 추정치에 큰 영향을 준다. 따라서 칼만 필터를 추측항법시스템에 적용 시킬 경우 실제 모텔의 잡음 공분산을 정확히 추정할 수 있는 기법이 요구된다. 추측항법시스템은 다양한 센서를 활용하기 때문에 움직이는 기동 표적에 적용시 잡음공분상이 변하기 때문에 항법시스템이 저하 될 수 있다. 본 연구에서는 다양한 센서를 융합하여 해양 생체 로봇의 정밀 자세 제어가 가능한 시스템을 제안하고자 한다.

  • PDF

Analysis and Application of Compact Planar Multi-Loop Self-Resonant Coil of High Quality Factor with Coaxial Cross Section (고품질 계수를 갖는 소형 평판형 동축 단면 다중 루프 자기 공진 코일 해석 및 응용)

  • Son, Hyeon-Chang;Kim, Jinwook;Kim, Do-Hyeon;Kim, Kwan-Ho;Park, Young-Jin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.4
    • /
    • pp.466-473
    • /
    • 2013
  • In this paper, a compact planar multi-loop self-resonant coil of high quality factor with a coaxial cross section is proposed for effective wireless charging. The proposed coil has high Q-factor and a resonant frequency of a coil can be easily controlled by adjusting distributed capacitance. For designing the coil, a self-inductance and a distributed capacitance are calculated theoretically. The self-inductance is calculated from the sum of the mutual energies between small circular loops that are made by dividing the cross section of the coil. To verify its properties and calculation results, the self-resonant coils are fabricated by using a coaxial cable with characteristic impedance of $50{\Omega}$. The measured frequencies are very consistent with the calculated ones. In addition, the resonant frequency can be adjusted slightly by the tuning parameter ${\gamma}$. The resonant coils are applied to a tablet PC, the Q-factors of the Tx and Rx resonant coils are 282 and 135, respectively. As a result of measurement when height between the two resonant coils is 4.4 cm, the power transfer efficiency is more than 80 % within a radius of 5 cm.

REPLACEMENT OF A PHOTOMULTIPLIER TUBE IN A 2-INCH THALLIUM-DOPED SODIUM IODIDE GAMMA SPECTROMETER WITH SILICON PHOTOMULTIPLIERS AND A LIGHT GUIDE

  • KIM, CHANKYU;KIM, HYOUNGTAEK;KIM, JONGYUL;LEE, CHAEHUN;YOO, HYUNJUN;KANG, DONG UK;CHO, MINSIK;KIM, MYUNG SOO;LEE, DAEHEE;KIM, YEWON;LIM, KYUNG TAEK;YANG, SHIYOUNG;CHO, GYUSEONG
    • Nuclear Engineering and Technology
    • /
    • v.47 no.4
    • /
    • pp.479-487
    • /
    • 2015
  • The thallium-doped sodium iodide [NaI(Tl)] scintillation detector is preferred as a gamma spectrometer in many fields because of its general advantages. A silicon photomultiplier (SiPM) has recently been developed and its application area has been expanded as an alternative to photomultiplier tubes (PMTs). It has merits such as a low operating voltage, compact size, cheap production cost, and magnetic resonance compatibility. In this study, an array of SiPMs is used to develop an NaI(Tl) gamma spectrometer. To maintain detection efficiency, a commercial NaI(Tl) $2^{\prime}{\times}2^{\prime}$ scintillator is used, and a light guide is used for the transport and collection of generated photons from the scintillator to the SiPMs without loss. The test light guides were fabricated with polymethyl methacrylate and reflective materials. The gamma spectrometer systems were set up and included light guides. Through a series of measurements, the characteristics of the light guides and the proposed gamma spectrometer were evaluated. Simulation of the light collection was accomplished using the DETECT 97 code (A. Levin, E. Hoskinson, and C. Moison, University of Michigan, USA) to analyze the measurement results. The system, which included SiPMs and the light guide, achieved 14.11% full width at half maximum energy resolution at 662 keV.

Arthroscopic Posterior Capsular Shaft for Traumatic Recurrent Unidirectional Posterior Subluxation of the Shoulder (외상으로 인한 재발성 단방향 견관절 후방 아탈구의 관절경을 이용한 후방낭 이동술)

  • Kim, Seung-Ho;Ha, Kwon-Ick;Yoo, Jae-Chul;Lee, Yong-Seuk;Lee, Hui-Dong
    • Clinics in Shoulder and Elbow
    • /
    • v.6 no.1
    • /
    • pp.55-66
    • /
    • 2003
  • Background: The purpose of this study was to evaluated results of arthroscopic treatment of the traumatic recurrent unidirectional posterior subluxation. Materials and Methods: We treated twenty-seven patients who had traumatic recurrent unidirectional posterior subluxation of the shoulder by arthroscopic labral repair and posterior capsular shift and prospectively evaluated for a mean of thirty-nine months (range,24 to 85 months). Patients who had posteroinferior instability, multidirectional instability, atraumatic onset, or revision cases were excluded. There were twenty-five male and two female patients with the mean age of twenty-one years (range, 14 to 33 years). All patients were involved in sports activity. All had a significant traumatic event prior to the onset of the instability. Stability, motion, three objective measurement (UCLA, ASES, and Rowe scores) and two subjective measurements (pain and function visual analogue scale) were evaluated. Results: The most common finding in magnetic resonance image-arthrogram was separation of the posteroinferior labrum without displacement in 9 patients, In arthroscopic examination, all patients had one or more lesions in the posterior inferior labrum and capsule. The most common finding was incomplete stripping of the posterior inferior labrum (18 patients). The posteroinferior capsule subjectively appeared to be stretched in twenty-two patients. At follow-up, all patients had improved shoulder function and scores(p < 0.01). All patients had stable shoulder by subjectivel and objectivel measurements, except one patient who had recurrent subluxation. All but one patient with postoperative recurrence were able to return to their prior sports activity with little or no limitation. Twenty-four patients were graded as having more than 90% of shoulder function. Their were twenty-one excellent, five good, and one fair UCLA. scores. Pain sore improved from 4.5 to 0.2 point(p : 0.0001). Mean loss internal rotation was one vertebral level. None had operative complications. Conclusion: In conclusion, treatment outcomes of the traumatic unidirectional recurrent posterior subluxation are consistently reliable with respect to the stability, pain relief, and functional restoration by the arthroscopic posterior capsular shift procedure.

Measurement of Tensile Properties for Thin Aluminium Film by Using White Light Interferometer (백색광간섭계를 이용한 알루미늄 박막의 인장 물성 측정)

  • Kim, Sang-Kyo;Oh, Chung-Seog;Lee, Hak-Joo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.5
    • /
    • pp.471-478
    • /
    • 2010
  • Thin films play an important role in many technological applications including microelectronic devices, magnetic storage media, MEMS and surface coatings. It is well known that a thin film's material properties can be very different from the corresponding bulk properties and thus there has been a strong need for the development of a reliable test method to measure the mechanical properties of a thin film. We have developed an alternative and convenient test method to overcome the limitations of previous membrane deflection experiment and uniaxial tensile test by adopting a white light interferometer having sub-nanometer out-of-plane displacement resolution. The freestanding aluminium specimens are tested to verity the effectiveness of the test method developed and get the tensile properties. The specimens are 0.5 rum wide, $1{\mu}m$ thick and fabricated through MEMS processes including sputtering. 1 to 5 specimens are fabricated on Si dies. The membrane deflection experiments are carried out by using a homemade tester consisted of a motor-driven loading tip, a load cell, and 6 DOF alignment stages. The test system is compact enough to set it up beneath a commercial white light interferometric microscope. The white light fringes are utilized to align a specimen with the tester. The Young's modulus and yield point stress of the aluminium film are 62 GPa and 247 MPa, respectively.

THE MILLIMETER-RADIO EMISSION OF BL LACERTAE DURING TWO γ-RAY OUTBURSTS

  • Kim, Dae-Won;Trippe, Sascha;Lee, Sang-Sung;Park, Jong-Ho;Kim, Jae-Young;Algaba, Juan-Carlos;Hodgson, Jeffrey A.;Kino, Motoki;Zhao, Guang-Yao;Wajima, Kiyoaki;Kang, Sincheol;Oh, Junghwan;Lee, Taeseok;Byun, Do-Young;Kim, Soon-Wook;Kim, Jeong-Sook
    • Journal of The Korean Astronomical Society
    • /
    • v.50 no.6
    • /
    • pp.167-178
    • /
    • 2017
  • We present a study of the inexplicit connection between radio jet activity and ${\gamma}$-ray emission of BL Lacertae (BL Lac; 2200+420). We analyze the long-term millimeter activity of BL Lac via interferometric observations with the Korean VLBI Network (KVN) obtained at 22, 43, 86, and 129 GHz simultaneously over three years (from January 2013 to March 2016); during this time, two ${\gamma}$-ray outbursts (in November 2013 and March 2015) can be seen in ${\gamma}$-ray light curves obtained from Fermi observations. The KVN radio core is optically thick at least up to 86 GHz; there is indication that it might be optically thin at higher frequencies. To first order, the radio light curves decay exponentially over the time span covered by our observations, with decay timescales of $411{\pm}85$ days, $352{\pm}79$ days, $310{\pm}57$ days, and $283{\pm}55$ days at 22, 43, 86, and 129 GHz, respectively. Assuming synchrotron cooling, a cooling time of around one year is consistent with magnetic field strengths $B{\sim}2{\mu}T$ and electron Lorentz factors ${\gamma}$ ~ 10 000. Taking into account that our formal measurement errors include intrinsic variability and thus over-estimate the statistical uncertainties, we find that the decay timescale ${\tau}$ scales with frequency ${\nu}$ like ${\tau}{\propto}{\nu}^{-0.2}$. This relation is much shallower than the one expected from opacity effects (core shift), but in agreement with the (sub-)mm radio core being a standing recollimation shock. We do not find convincing radio flux counterparts to the ${\gamma}$-ray outbursts. The spectral evolution is consistent with the 'generalized shock model' of Valtaoja et al. (1992). A temporary increase in the core opacity and the emergence of a knot around the time of the second ${\gamma}$-ray event indicate that this ${\gamma}$-ray outburst might be an 'orphan' flare powered by the 'ring of fire' mechanism.

A Novel Method to Measure Superior Migration of the Humeral Head: Step-off of the C-line

  • Park, Kyoung Jin;Eun, Hyeon Jun;Kim, Yong Min;Yoo, Jun Il;Lim, Chae Ouk
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.3
    • /
    • pp.125-129
    • /
    • 2016
  • Background: Superior migration of humeral head has been conventionally determined by measuring the acromiohumeral distance (AHD), We sought to devise a novel measurement system more reliably and accurately than AHD. We described a structural landmark called 'C-line'. In this study, we investigated the clinical usefulness of 'step-off of the C-line (SOC)' compared to that of AHD. Methods: The C-line formed from the medial margin of the proximal humeral head continuing up to the inferior margin of the articular glenoid and then to the lateral border of the scapula. The superior migration of the humeral head triggered by a rotator cuff tear introduces a discontinuity in this C-line. We measured the distance of this discontinuity. We enrolled 144 patients who underwent a rotator cuff repair. We selected 58 controls who didn't have any cuff lesions apparent on magnetic resonance imaging. Using radiographs derived from standardized true anteroposterior views of the shoulder, we measured the SOC and the AHD. We used t-tests for statistical analyses. Results: A rotator cuff tear was associated with an increase in SOC and a decrease in AHD. In control group, the mean SOC was $1.29{\pm}1.71mm$ and AHD was $9.71{\pm}2.65mm$. In cuff tear group, the mean SOC was $3.15{\pm}3.41mm$ and AHD was $8.28{\pm}1.76mm$. The mean SOCs of the patient group in relation to the mean SOC of the control group according to tear size, the SOCs of medium tear and lager groups showed statistically significant increase (p<0.05). Conclusions: The SOC may be a similarly effective to diagnose cuff tears of medium size and larger compared with AHD.

Synthesis and Magnetic Properties of Nanosized Ce-substituted Yttrium Iron Garnet Powder Prepared by Sol-gel Method (졸-겔법에 의한 Cerium 치환 Nanosize YIG 분말의 합성 및 자기적 특성)

  • 장학진;김광석;윤석영;김태옥
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.11
    • /
    • pp.1008-1014
    • /
    • 2001
  • Nanosize YIG powders added by Cerium which is exellent element in magneto-optical effect were synthesized by Sol-Gel method using Ethylene Glycol solvent. In 120 to 150 minute reaction time, stable sol solution which showed no change in viscosity, pH, and aging time was obtained. Monolithic YIG was synthesized at 80$0^{\circ}C$ with DTA and XRD measurement and its lattice parameter had a tendency to increase from 12.3921 $\AA$. Increasing annealing temperature from 80$0^{\circ}C$ to 105$0^{\circ}C$, average particle size was in the range of 40 nm to 330 nm. Saturation magnetization (M$_{s}$) value was increased from 18.37 to 21.25 emu/g due to enhancement of YIG crystallity and decreasing of orthoferrite phase. On the other hand, coercivity (H$_{c}$) value increased up to 90$0^{\circ}C$ and then decreased above 90$0^{\circ}C$. With increasing Ce addition, coercivity was almost not changed but saturation magnetization value was maximum at Ce 0.1 mol% and then decreased because of increasing a orthoferrite amount. Also, curie temperature (T$_{c}$) of YIG were not changed with Ce addition.ion.

  • PDF

Hyperthermia Properties of Fe3O4 Nanoparticle Synthesized by Hot-injection Polyol Process (Hot-injection Polyol 공정에 의해 제조된 Fe3O4 나노입자의 Hyperthermia 특성)

  • Lee, Seong Noh;Kouh, Taejoon;Shim, In-Bo;Shim, Hyun Ju
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.2
    • /
    • pp.51-55
    • /
    • 2014
  • The $Fe_3O_4$ nanoparticle was synthesized by the hot-injection method while varying the injection time of the precursor solution. The crystal structure was determined to be cubic inverse spinel with space group of Fd-3m based on X-ray diffraction (XRD) measurements and the morphology of the prepared $Fe_3O_4$ nanoparticle was studied with a high-resolution transmission electron microscope (HR-TEM). When the precursor solution was injected for 0.5 min, the size of the $Fe_3O_4$ nanoparticle was 7.63 nm, while the size of the obtained particle was 21.27 nm with the injection time of 60 min. The magnetic properties of the prepared $Fe_3O_4$ nanoparticle were investigated by both vibrating sample magnetometer (VSM) and $^{57}Co$ M$\ddot{o}$ssbauer spectroscopy at various temperatures. From the hyperthermia measurement, we observed that the temperature of the $Fe_3O_4$ nanoparticle powder reached around $120^{\circ}C$ under 250 Oe at 50 kHz, when the injection time of the precursor solution was 60 min.