• 제목/요약/키워드: magnetic induction

검색결과 577건 처리시간 0.024초

발전기용 오스테나이트계 18Mn-18Cr 고질소강의 제조와 인장강도 예측 (Prediction of Tensile Strength of High-Nitrogen 18Mn-18Cr Austenitic Steels for Generator Retaining Ring)

  • 황병철;이태호
    • 한국재료학회지
    • /
    • 제23권9호
    • /
    • pp.483-488
    • /
    • 2013
  • Over the past few decades, high-nitrogen austenitic steels have steadily received greater attention since they provide a unique combination of high strength and ductility, good corrosion resistance, and non-magnetic properties. Recently, highnitrogen 18Mn-18Cr austenitic steels with enhanced strength have been developed and widely used for generator retaining rings in order to prevent the copper wiring from being displaced by the centrifugal forces occurring during high-speed rotation. The high-nitrogen austenitic steels for generator retaining ring should be expanded at room temperature and then stress relief annealed at around $400^{\circ}C$ to achieve the required mechanical properties. In this study, four kinds of high-nitrogen 18Mn-18Cr austenitic steels with different nitrogen content were fabricated by using a pressurized vacuum induction melting furnace, and then the effects of nitrogen content, cold working, and stress relieving on tensile properties were investigated. The yield and tensile strengths increased proportionally with increasing nitrogen content and cold working, and they further increased after stress relieving treatment. Based on these results, a semi-empirical equation was proposed to predict the tensile strength of highnitrogen 18Mn-18Cr austenitic steels for generator retaining rings. It will be a useful for the effective fabrication of high-nitrogen 18Mn-18Cr austenitic steels for generator retaining rings with the required tensile properties.

한 종합병원의 MRI 채산성 사례 연구 (A Case Study on the MRI Profitability of a General Hospital)

  • 강창렬;송성호;임경태
    • 보건의료산업학회지
    • /
    • 제4권1호
    • /
    • pp.145-156
    • /
    • 2010
  • The purpose of this study is one of high price medical equipment wished to grasp propriety factor about the MRI introduction, analyzing payability through cost accounting into compensation. It was investigated from January 1 to December 31, 2007 about the MRI of a General Hospital. Expectation availability was 23.2 cases, but actual availability did achievement more than 196.1% with 45.5 items. It is estimated that there are a lot of occurrence cases because great reasons that actual availability increases more than expectation availability is excellent resolving power than a CT, and is device that prefer to reason back that radiation damage is less in person body. The followings show the main results of this study. 1. The MRI was construed in order of cost accounting, wave and personnel expenses 45.4%, administrative expenses 53.0%, and material costs 1.6%. 2. According to CVP (Cost-volume-profit) analysis, BEP (Break Even Point) profit is 173,931,428 won for 11 months, and break even usage number of items are 37.5 cases, and separation usage number of items were confirmed by 1.4 cases. Therefore, was construed that can achieve BEP within 11 months though usage number of items keeps 1.4 items day to create the MRI's hospital operation profit. 3. Estimated limit profitability appears high by 96.7%, exceed fixed charges even if when is non-benefit and when it is benefit consider variable, is judged that the MRI's addition induction helps in hospital management enhancing earning rates.

레이저 무선충전 기술 연구 (Study on a Laser Wireless Power Charge Technology)

  • 이동훈;김성만
    • 한국전자통신학회논문지
    • /
    • 제11권12호
    • /
    • pp.1219-1224
    • /
    • 2016
  • 현재까지 개발된 무선 충전기술은 크게 전자기유도 방식, 자기공명 방식, 전자기파 방식 등이 있다. 하지만 기존의 방법들은 전송거리가 짧거나 전자파 장해를 일으키는 문제를 가지고 있다. 이러한 문제점을 해결하기 위하여 본 논문에서는 레이저를 이용한 무선충전 기술에 대해 연구하고 이에 대한 실험결과를 보인다. 이 기술은 송신단에 전/광 변환을 위한 레이저 광원을 사용하여 빛의 형태로 에너지를 무선으로 전송하며, 수신단에는 광/전 변환을 위해 태양전지나 PD(: Photo Diode)를 이용하는 방식이다. 10m 이상의 장거리에서는 레이저 무선충전 기술의 전송효율이 가장 높을 것으로 전망되며, 장거리 무선충전에서는 레이저 무선충전 기술이 가장 효율적인 무선충전 기술이 될 것으로 판단된다. 본 논문의 실험결과에서는 100 mW Red 레이저 송신부와 PD 수신부를 이용하여 70 m의 장거리 전송거리에서 DC-to-DC 로 2.15 %의 무선전력전송 효율을 보였다.

복합교반법에 의한 금속복합재료의 제조공정에 따른 강화재의 분산성 검토 (Investigation of Reinforced Distribution in Fabrication Process of Metal Matrix Composites by Combined Stirring Process)

  • 이동건;강충길
    • Composites Research
    • /
    • 제14권5호
    • /
    • pp.1-11
    • /
    • 2001
  • 본 논문은 금속복합재료를 반용융상태로 재가열하여 Thixoforming을 하는데 필요한 소재를 제공하기 위한 장비 설계와 제조방법 등에 관한 내용을 소개하고 있다. 장비 설계에서 기지재내에 강화재가 균일하게 분산되도록 하기 위하여 강화재의 연속주입 방법과 강화재의 온도를 제어하는 방법을 소개하고 있다. 일정한 양의 강화재를 기지재료 내에 분산시키는 것은 균일 혼합을 위하여 필요한 기술이다. 또한 분산시 강화재의 수분제거를 위하여 강화재의 온도를 제어하면서 연속적으로 강제분산시키는 것은 균일분산을 위하여 필요하다. 기지재의 초정 $\alpha$의 크기가 강화재의 분산성에 크게 영향을 미치기 때문에 기지재의 초기 온도가 초정$\alpha$의 크기에 미치는 영향 등을 검토하여 복합재료 빌렛트의 제조조건에 이용하였다.

  • PDF

저전도율 유체 측정에서 소형 전자기유량계의 신호 특성 (Flow Signal Characteristics of Small Scale Electromagnetic Flowmeter in Low Conductivity Fluid Measurement)

  • 임기원;정성수
    • 대한기계학회논문집B
    • /
    • 제40권9호
    • /
    • pp.613-620
    • /
    • 2016
  • 유체의 전도율(conductivity)이 전자기유량계의 특성에 미치는 영향을 평가하기 위해 소형 전자기 유량계를 설계 제작하였다. 유량계의 측정관(measuring tube)은 $4mm{\times}3mm$의 직사각형 단면을 가지며 길이는 9 mm이다. 전극은 직경이 1.5 mm인 점전극과 단면이 $2mm{\times}3mm$인 면전극으로 설계하였다. 코일의 열 발생에 영향을 미치는 자화주파수, 회전수 및 굵기를 변화시키면서 최적값을 찾았다. 최적화된 측정관은 자속밀도(magnetic flux density) 0.04 T (400 gauss)를 발생시키며 안정되고, 선형적인 유량신호를 얻을 수 있었다. 유량계를 특성을 평가하기 위해 중량식 유량계 교정 장치를 제작하였다. 유동율 범위는 최대 $1.17{\times}10^{-5}m^3/s$(700 cc/min)이며 ISO규격에 따라 유동량 결정의 불확도를 평가하였으며 크기는 0.06 % 이내이었다. 유체의 전도율은 $3-11{\mu}S/cm$ 사이에서 조절하였다.

Dobutamine 투여 후 발생한 개의 서맥 1례 (Bradycardia after Dobutamine Administration in a Dog)

  • 장민;손원균;황혜신;조상민;이강재;윤정희;이인형
    • 한국임상수의학회지
    • /
    • 제31권4호
    • /
    • pp.350-353
    • /
    • 2014
  • A 13-year-old, castrated male, Shih Tzu dog with a history of acute ataxia was referred to veterinary medical teaching hospital and anesthetized for diagnostic magnetic resonance imaging of cervical intervertebral disk disease. After preanesthetic evaluation including physical examination, blood chemistry, radiography and ultrasound, the patient was premedicated with intravenous butorphanol (0.2 mg/kg). Anesthesia was induced by intravenous propofol (6 mg/kg) and maintained with isoflurane at 1.2 minimal alveolar concentrations. Because the mean arterial pressure (MAP) decreased from 70 to 58 mmHg at 70 minutes after induction, dobutamine was administered by constant rate infusion ($5{\mu}g/kg/min$) to treat hypotension. However MAP did not increase, and heart rate rapidly decreased from 100 to 55 beats per minute (bpm). To treat bradycardia, intravenous glycopyrrolate ($5{\mu}g/kg$) was administered, and heart rate increased to 165 bpm. After extubation of endotracheal tube, the patient showed normal recovery without any problems related to cardiovascular system. Unexpected dobutamine-induced bradycardia was considered as Bezold-Jarisch reflex. It is recommended that clinicians know and prepare the possibility of bradycardia during dobutamine therapy under general anesthesia.

가토 두개부 골결손에서 맥동전자기장이 골형성에 미치는 영향에 관한 연구 (A STUDY OF EFFECT OF PULSED ELECTROMAGNETIC FIELDS ON OSTEOGENESIS IN RABBIT CRANIAL BONE DEFECT)

  • 황경균;이종환;김명진;심광섭;김종원
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제28권4호
    • /
    • pp.264-273
    • /
    • 2002
  • Pulsed electromagnetic field (PEMF) was used first to induce osteogenesis in 1974. The appliance which was consisted of the Helmholtz coil configuration have used to osteogensis. The objective of this study was to determine whether PEMF, a frequency of 100 Hz and magnetic field strength of 38 gauss applied to the calvarial defect in rabbit, could affect the induction of osteogenesis and the healing of the graft bone. This field should not produce excitation of nerve or muscle and heating the tissue. To evaluate the effect of PEMF on osteogenesis, 16 rabbit under the same condition was divided into 8 experimental groups and 8 control groups. 10 mm calvarial bone defects were formed around sagittal suture. The defect of left side was left without graft while the defect of right side was grafted by bone harvested from left side. A pulsed electromagnetic field was applied for 8 hours per day. Each group was sacrificed after 1 week, 2 weeks, 4 weeks, 8 weeks. Microscopic specimens were obtained from the calvarial bone defects and surrounding tissue using Hematoxylin-Eosin staining method. The results were as follows. 1. In the group which pulsed electromagnetic field was applied, new bone formation filled up the defect was observed after 4 and 8 weeks effectively. 2. There are no difference in the healing period for the fusion between the bone and graft bone. According to the result, the PEMF with 38 Gauss, 100 Hz was very effective in the healing of bone defect and new bone formation. So The PEMF will be useful in clinical aspect for oseteogenesis.

화학 결합 종류에 따른 생활 용품 기반 마찰 발전기 거동 연구 (Investigation on Behaviors of Triboelectric Nanogenerators Based on Life Supplies according to Kinds of Chemical Bonding)

  • 황희재;최동휘;최덕현
    • Composites Research
    • /
    • 제32권6호
    • /
    • pp.307-313
    • /
    • 2019
  • Triboelectric nanogenerators (TENGs)는 정전기 기반의 마찰 전기 발전기로써 간단한 구조로 저비용, 대면적으로 손쉽게 활용할 수 있는 기술이다. 본 연구에선 생활 용품을 활용하여 화학적 결합 및 SEM image로써 분석을 하고 C-C/C-H/C-O/C=O bonding에 따라 bonding 조성비에 따라 C-C bonding의 비율이 클수록 음전하, C-H bonding 비율이 클수록 양전하 대전체가 되는 것을 확인하였다. 그러한 특성을 가지고 최적 생활용품을 활용하여 정전 출력 실험을 했을 때 최대 210 V, 14.6 ㎂, 9.83 mW의 출력을 얻었다. 최종적으로, 랩과 마그네틱 노트를 이용해 97개의 Light Emitting Diodes (LEDs)를 점등할 수 있었다.

SnO2, CaO가 NiCuZn Ferrite의 전자기적 특성에 미치는 영향 연구 (A Study on the Electromagnetic Property of NiCuZn Ferrite by Additive SnO2, CaO.)

  • 김환철;고재귀
    • 한국자기학회지
    • /
    • 제13권3호
    • /
    • pp.121-126
    • /
    • 2003
  • (N $i_{0.2}$C $u_{0.2}$Z $n_{0.6}$)$_{1.085}$(F $e_2$ $O_3$)$_{0.915}$의 기본 조성에 첨가제 Sn $O_2$, CaO 첨가량과 ferrite의 공정을 변화시켜 시편의 전자기적 특성 및 미세구조를 조사하였다. 첨가제에 따른 입자크기의 변화는 거의 없었다. (N $i_{0.2}$C $u_{0.2}$Z $n_{0.6}$)$_{1.085}$(F $e_2$ $O_3$)$_{0.915}$을 소결시 1300 $^{\circ}C$에서 소결하는 것보다 1150 $^{\circ}C$에서 소결한 소결체의 손실이 더욱 적었다. CaO만 첨가할 때 0.2 wt%가 소결밀도를 크게하여 손실을 줄여주는 첨가제로 사용 가능함을 확인하였다 Sn $O_2$차 Ca $O_2$함께 첨가시 SnO2$_2$ 0.06 wt%, CaO 0.4 wt%가 손실을 크게 줄여 주는 것으로 조사되었다.

Long-Term Follow-Up Result of Hydroxyurea Chemotherapy for Recurrent Meningiomas

  • Kim, Min-Su;Yu, Dong-Woo;Jung, Young-Jin;Kim, Sang Woo;Chang, Chul-Hoon;Kim, Oh-Lyong
    • Journal of Korean Neurosurgical Society
    • /
    • 제52권6호
    • /
    • pp.517-522
    • /
    • 2012
  • Objective : Meningiomas represent 18-20% of all intracranial tumors and have a 20-50% 10-year recurrence rate, despite aggressive surgery and irradiation. Hydroxyurea, an inhibitor of ribonucleotide reductase, is known to inhibit meningioma cells by induction of apoptosis. We report the long-term follow-up result of hydroxyurea therapy in the patients with recurrent meningiomas. Methods : Thirteen patients with recurrent WHO grade I or II meningioma were treated with hydroxyurea (1000 $mg/m^2/day$ orally divided twice per day) from June 1998 to February 2012. Nine female and 4 male, ranging in age from 32 to 83 years (median age 61.7 years), were included. Follow-up assessment included physical examination, computed tomography, and magnetic resonance imaging (MRI). Standard neuro-oncological response criteria (Macdonald criteria) were used to evaluate the follow-up MRI scans. The treatment was continued until there was objective disease progression or onset of unmanageable toxicity. Results : Ten of the 13 patients (76.9%) showed stable disease after treatment, with time to progression ranging from 8 to 128 months (median 72.4 months; 6 patients still accruing time). However, there was no complete response or partial response in any patients. Three patients had progressive disease after 88, 89, 36 months, respectively. There was no severe (Grade III-IV) blood systemic disorders and no episodes of non-hematological side effects. Conclusion : This study showed that hydroxyurea is a modestly active agent against recurrent meningiomas and can induce long-term stabilization of disease in some patients. We think that hydroxyurea treatment is well tolerated and convenient, and could be considered as an alternative treatment option in patients with recurrent meningiomas prior to reoperation or radiotherapy.