• Title/Summary/Keyword: magnetic film

Search Result 1,018, Processing Time 0.032 seconds

Identification of Dynamic Characteristics of Squeeze Film Damper Using Active Magnetic Bearing System as an Exciter (자기 베어링 시스템을 가진기로 이용한 스퀴즈 필름 댐퍼의 동특성 계수 규명)

  • 김근주;이종원
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.7
    • /
    • pp.508-516
    • /
    • 2003
  • The dynamic characteristics of an ell-lubricated, short squeeze film damper (SFD) with a central feeding groove are derived based on a theoretical analysis considering the effect of a groove, and identified experimentally using an Active Magnetic Bearing (AMB) system as an exciter. In order to get the theoretical solution, the fluid film forces of the grooved SFD are analytically derived so that the dynamic coefficients of the SFD can be expressed in terms of its design parameters. For the experimental validation of the analysis, a test rig using an AMB as an exciter is proposed. As an exciter. the AMB represents a mechatronic device to levitate and position the test Journal without any mechanical contact, to generate relative motions of the Journal inside the tested SFD and to measure the generated displacements during experiments with fairly high accuracy. Using this test rig, experiments are extensively conducted with various values of clearance, which Is one of the most important design parameters. in order to investigate its effect on the dynamic characteristics and the performance of the SFD. Damping and Inertia coefficients of the SFD that are experimentally Identified are compared with the analytical results to demonstrate the effectiveness of the applied analysis. It Is also shown that the AMB is an ideal device for tests of SFDs.

Characterizing Pb-based superconducting thin films

  • Park, Sang-Il;Kim, Hong-Seok;Lee, Joon Sung;Doh, Yong-Joo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.4
    • /
    • pp.36-39
    • /
    • 2014
  • We report on the superconducting and structural characteristics of Pb-based alloy ($Pb_{0.9}In_{0.1}$, $Pb_{0.8}In_{0.2}$ and $Pb_{0.85}Bi_{0.15}$) thin films, depending on the film deposition rate. The maximum critical magnetic field strength of $Pb_{0.85}Bi_{0.15}$ is almost six times larger than that of $Pb_{0.9}In_{0.1}$, and more rapid growth of the film enhances the critical magnetic field strength even for the same alloy material. Scanning electron microscopy inspection indicates that lower deposition rate condition is vulnerable to the formation of void structure in the film. Topographic images using atomic force microscopy are useful to optimize the deposition condition for the growth of smooth superconducting film. Our work can be utilized for future studies on hybrid superconducting devices using low-dimensional nanostructures.

Size and Aspect Ratio Effects on the Magnetic Properties of a Spin-Valve Multilayer by Computer Simulation

  • Lim, S.H.;Han, S.H.;Shin, K.H.;Kim, H.J.
    • Journal of Magnetics
    • /
    • v.5 no.3
    • /
    • pp.90-98
    • /
    • 2000
  • The change in the magnetic properties of a spin-valve multilayer with the structure IrMn (9 m)/CoFe (4 nm)/Cu (2.6 nm)/CoFe (2 nm)/NiEe (6 nm) is investigated as a function of the size and the aspect ratio. At a fixed aspect ratio (the length/width ratio) of 2, the magnetostatic interactions begin to affect the magnetic properties substantially at a spin-valve length of 5 $\mum$, and, at a length of 1 $\mum$, they become even more dominant. In the case of a fixed multilayer size (2.4 $\mum$) which is indicated by the sum of the length and the width, magnetization change occurs by continuous spin-reversal and M-H loops are characterized by no or very small hysteresis at aspect ratios smaller than unity, At aspect ratios greater than unity, magnetization change occurs by spin-flip resulting in squared hysteresis loops. A very large changes in the coercivity and the bias field is observed, and these results are explained by two separate contributions to the total magnetostatic interactions: the coercivity by the self-demagnetizing field and the bias field by the interlayer magnetostatic interaction field.

  • PDF

Mn Thin Film on $BaTiO_3$ Substrate: Modified Electrical and Magnetic Properties

  • Tuan, Duong Anh;Cuong, Tran Viet;Shin, Yooleemi;Cho, Sunglae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.162-162
    • /
    • 2013
  • Magnetic properties of 3d transition metals were determined by exchange interaction between magnetic ions that was characterized by the exchange integral. Bulk Mn material is one of transition metals that have been well known as an anti-ferromagnetic material due to an anti-parallel spin with negative exchange integral. Here we report on the MBE growth of Mn on $BaTiO_3$ (001) substrate and induced ferromagnetism. The bcc ${\alpha}$-Mn single crystal film has been grown on $BaTiO_3$ (100) substrate. The XRD and Raman results indicated that the structural phase transitions of $BaTiO_3$ substrate induced a lattice distortion at the interface. Consequently, the grown Mn film exhibits ferromagnetism with strong saturation magnetization of 495 emu/$cm^3$ at 320 K. The electrical resistivity of the Mn film strongly depended on the crystal structure of $BaTiO_3$ substrate.

  • PDF

Velocity Change of Magneto Surface Acoustic Wave (MSAW) in $({Fe_{1-x}}{Co_x})_{89}{Zr_{11}}$ Amorphous Films (I) ($({Fe_{1-x}}{Co_x})_{89}{Zr_{11}}$비정질 자성 막에서의 자기표면탄성파 속도변화 (I))

  • Kim, Sang-Won
    • Korean Journal of Materials Research
    • /
    • v.11 no.6
    • /
    • pp.477-482
    • /
    • 2001
  • The velocity changes of magneto surface acoustic wave (MSAW) have been investigated in the MSAW devices composed of wedge type transducer and as-sputtered ($Fe_{1-x}$ $Co_{x}$ )$_{89}$ $Zr_{ 11}$ (x=0~1.0)amorphous films on glass substrates. The velocity changes of devices depended sensistively on exciting frequency of MSAW, applying the DC bias magnetic field. film thickness and film composition. Particularly. it was conformed that velocity changes increased with the increase of the exciting frequency of MSAW and the thickness of magnetic films. A device deposited x= 0.8 film along the MSAW propagation direction among the devices exhibited a large velocity change of 0.062% at 8.7 MHz for the applied field of 70 Oe.

  • PDF

Effect of Antibacterial Film Containing Silver Ions on MRI (은(Ag)이온이 함유된 항균필름이 MRI에 미치는 영향)

  • Shin, Byeong Geun;Kim, Seong Hu;Ahn, Seong Min
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.219-224
    • /
    • 2021
  • The purpose of these experiments is often to scan infected patients with MRI. Therefore, it is to investigate whether the antibacterial film containing silver ions, which is a non-magnetic substance, affects magnetic resonance imaging. In this experiment, the ACR phantom was used, not the patient. The ACR phantom was wrapped in an antibacterial film and the SNR, CNR, sagittal localization image, and geometrical accuracy were compared before and after. The experiment was performed 10 times and the averaged values were compared. There were no significant differences in the results of all experiments. The FDA recommends removing metal and antibacterial film masks during MRI scans. The reason is that there was one case of injury with facial burns. When I touched the antibacterial film to check the fever during the 2 hour experiment, I did not feel any particular fever. In light of the experimental results, it would be helpful to use an antibacterial film when testing an infected patient. The reason is that there isn't a difference before and after the experiment of SNR, CNR, and sagittal localization images.

Studies of Simultaneous Quench of Superconducting YBCO Flims for Fault Current Limiter Under the Influence of Magnetic Fields (자기장인가에 따른 YBCO 박막형 한류기의 동시?치 연구)

  • 박권배;이방욱;강종성;오일성;최효상;현옥배
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.84-88
    • /
    • 2002
  • The resistive fault current limiter (SFCL) is a very attractive device for power networks. But it has a serious Problem in using YBCO films for fault current limiter is inhomogeneities caused by imperpect manufacturing. So simultaneous quenches are a difficult problem which elements for current limiting are connected in series for increasing voltage ratings. We investigated extended electric field-current characteristics for current limiting element of YBCO film when O-130mT magnetic field is applied. And quench characteristics were investigated in over all element and between elements of YBCO films. From the experiments, it was shown that applied magnetic fields using solenoid coil induced uniform quench distribution for over all stripes and simultaneous quench in all elements for current limiting of YBCO film was realized. We have achieved resistive fault current limiter of 1.2kV/20A rating using magnetic field.

FeCoB Films with Large Saturation Magnetization and High Magnetic Anisotropy Field to Attain High Ferromagnetic Resonance Frequency

  • Nakagawa, Shigeki;Hirata, Ken-Ichiro
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.155-158
    • /
    • 2013
  • FeCoB films were being prepared on a Ru underlayer by using the oblique incidence of sputtered and back-scattered particles which have a high in-plane magnetic anisotropy field $H_k$ above 400 Oe. It is suitable to attain such deposition condition when facing targets sputtering system. The in-plane X-ray diffraction analysis clarified that there is anisotropic residual stress which is the origin of the high in-plane magnetic anisotropy. The directional crystalline alignment and inclination of crystallite growth were also observed. Such anisotropic crystalline structures may affect the anisotropic residual stress in the films. The B content of 5.6 at.% was appropriate to induce such anisotropic residual stress and $H_k$ of 410 Oe in this experiment. The film with B content of 6 at.% possessed large saturation magnetization of 22 kG and high $H_k$ of 500 Oe. The film exhibited high ferromagnetic resonance frequency of 9.2 GHz.

Structural and Magnetic Properties of perpendicular Recording Medium CoCrMo thin Film (수직자기기록매체 CoCrMo 박막의 구조와 자기적 성질)

  • 남인탁;홍양기
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1988.10a
    • /
    • pp.46-46
    • /
    • 1988
  • Structural and magnetic properties of Co-Cr-Mo films were investigated in connection with sputtering conditions. Films were prepared using a convention RF sputtering system. X-ray diffractometry, scanning electron microscopy and transmission electron microscopy were employed to investigate structure properties. Vibrating sample magnetometry was used for coercivity and saturation magnetization measurements. Co-Cr-Mo films displayed reasonable values of perpendicular coercivity and saturation magnetization for perpendicular recording media and showed good perpendicular orientation of the hcp c-axis to the film surface. Perpendicular coercivity was strongly dependent upon substrate technique showed better c-axis orientation than hose using the stationary substrate. Co-Cr-Mo films of 2.9 at. % Mo content showed maximum perpendicular coercivity and saturation magnetization. The films deposited at lower Ar pressure showed good magnetic properties. There was no explicit relationship between the columnar structure and c-axis orientation. Co-Cr-Mo films was found to have suitable structural and magnetic properties for perpendicular recording media.

  • PDF

Preparation of Thin Film for Perpendicular Magnetic Recording (수직자기기록용 박막의 제작)

  • 김경환;김명호;손인환;김재환
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.309-312
    • /
    • 1997
  • The Ce-Cr(-Ta) film are one of the most suitable candidates for perpendicular magnetic media. the control of the preparation conditions, such as Ar gas pressure P$\_$Ar/ substrates temperature T$\_$s/, films thickness $\delta$, deposition speed R$\_$d/, is considered to be important to attain ultra high density recording far perpendicular magnetic recording media. In this study, the Co-Cr thin films and Co-Cr-Ta thin films were deposited on the glass side substrates by using Facing Targets Sputtering apparatus(FTS). Crystallographic characteristics and magnetic characteristics were evaluated by X-ray diffractometry(XRD), Vibrating Sample Magnetometer(VSM) respectively.

  • PDF