비접촉식 전류 검출 장치에 관한 연구 (A Study on the Current Detector with Non Contact Type)

  • 김기준
    • 한국전기전자재료학회논문지
    • /
    • 제31권5호
    • /
    • pp.351-356
    • /
    • 2018
  • Commonly, a live-line alarm can be used to measure the electric field strength of a high-voltage system to calculate its current, but it is hard to detect the electric field of shielded cables or concealed structures, such as underground distribution cables. Current sensors can detect the magnetic field in a single core wire, but they cannot determine the magnetic field about a double-core wire because the currents flow in opposite directions. Therefore, it is very difficult to detect certain current problems, such as a fault current in an extension line comprised of a double line. In this paper, to ultimately develop a sensor that can detect the current regardless of line conditions, we used a simulation to determine the concentration of the magnetic field dependent on the distribution of the external magnetic field and the path of each line's core.

The effect of field-line twist on the dynamic nature and electric current structure of emerging magnetic field on the Sun

  • 안준모;;이환희;강지혜
    • 천문학회보
    • /
    • 제37권1호
    • /
    • pp.87.1-87.1
    • /
    • 2012
  • We use three-dimensional magnetohydrodynamic simulations to investigate how the dynamic state of emerging magnetic field is related to the twist of field lines. Emergence of magnetic field is considered as one of the key physical process producing solar activity such as flares, jets, and coronal mass ejections. To understand these activities we have to know dynamic nature and electric current structure provided by emerging magnetic field. To demonstrate dynamic nature of field lines, we focus on the factors such as curvature of magnetic field line and scale height of magnetic field strength. These factors show that strong twist case forms two-part structure in which the central part is close to a force-free state while the outer marginal part is in a fairly dynamic state. For weak twist case, it still shows two-part structure but the tendency becomes weaker than strong twist case. We discuss how the curvature distribution affects the dynamic nature of emerging magnetic field. We also investigate electric current distribution provided by emerging field lines to show a possible relation between electric current structure and sigmoid observed in a preflare phase.

  • PDF

Gas and Magenetic Field Effect to Low Pressure Plasma

  • 배인식;나병근;설유빈;유신재;김정형;장홍영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.557-557
    • /
    • 2013
  • Plasma hardly grows in lowpressure because of lack of collision. But low pressure plasma has useful properties because it has typically low electron density. In here, thermal electron is used to make breakdown in low pressure easily. We changed magnetic field strength and gas to control electron density or temperature. IV characteristic and electron density of the discharge are examined and the characteristic of the discharge in presence of magnetic field is also examined. Results showed that depending on the ionization cross section of the gas, electron density is changed and proper strength of magnetic field is required for high electron density.

  • PDF

Leakage Magnetic Field Suppression Using Dual-Transmitter Topology in EV Wireless Charging

  • Zhu, Guodong;Gao, Dawei;Lin, Shulin
    • Journal of Power Electronics
    • /
    • 제19권3호
    • /
    • pp.625-636
    • /
    • 2019
  • This paper proposes an active leakage magnetic field (LMF) suppression scheme, which uses the dual-transmitter (DT) topology, for EV wireless charging systems (EVWCS). The two transmitter coils are coplanar, concentric and driven by separate inverters. The LMF components generated by the three coils cancel each other out to reduce the total field strength. This paper gives a detailed theoretical analysis on the operating principles of the proposed scheme. Finite element analysis is used to simulate the LMF distribution patterns. Experimental results show that when there is no coil misalignment, 97% of the LMF strength can be suppressed in a 1kW prototype. These results also show that the impact on efficiency is small. The trade-off between LMF suppression and efficiency is revealed, and a control strategy to balance these two objectives is presented.

초급성 허혈성 뇌졸중 환자에서 관류자기공명영상의 정량적 평가: 1.5 T와 3.0 T 기기 비교 (Quantitative Evaluation of Perfusion Magnetic Resonance Imaging in Hyper-acute Ischemic Stroke Patients: Comparison with 1.5 T and 3.0 T Units)

  • 구은회;문일봉;동경래
    • 방사선산업학회지
    • /
    • 제10권4호
    • /
    • pp.193-198
    • /
    • 2016
  • Perfusion magnetic resonance image of biological mechanism are independent of magnetic field strength in hyper acute ischemic stroke. 3.0 T magnetic field, however, does affect the SNRs (signal to noise ratio) and artifacts of PMRI (perfusion magnetic resonance image), which basically will influence the quantitative of PMRI. In this study, the effects of field strength on PMRI are analyzed. The effects of the diseases also are discussed. PMRI in WM(white matter), GM (gray matter), hyper acute ischemic stroke were companied with 1.5 T and 3.0 T on SNR. PMRI also was compared to the SI difference after setting ROI(region of interest) in left and right side of the brain. In conclusion, the SNRs and SI of the 3.0 T PMRI showed higher than those at 1.5 T. In summary, PMRI studies at 3.0 T is provided significantly improved perfusion evaluation when comparing with 1.5 T.

뇌자도를 이용한 언어 편재화: 예비 연구 (Language Lateralization Using Magnetoencephalography (MEG): A Preliminary Study)

  • 이서영;강은주;김준식;이상건;강혜진;박효진;김성훈;이승환;정천기
    • Annals of Clinical Neurophysiology
    • /
    • 제8권2호
    • /
    • pp.163-170
    • /
    • 2006
  • Backgrounds: MEG can measure the task-specific neurophysiologic activity with good spatial and time resolution. Language lateralization using noninvasive method has been a subject of interest in resective brain surgery. We purposed to develop a paradigm for language lateralization using MEG and validate its feasibility. Methods: Magnetic fields were obtained in 12 neurosurgical candidates and one volunteer for language tasks, with a 306 channel whole head MEG. Language tasks were word listening, reading and picture naming. We tested two word listening paradigms: semantic decision of meaning of abstract nouns, and recognition of repeated words. The subjects were instructed to silently name or read, and respond with pushing button or not. We decided language dominance according to the number of acceptable equivalent current dipoles (ECD) modeled by sequential single dipole, and the mean magnetic field strength by root mean square value, in each hemisphere. We collected clinical data including Wada test. Results: Magnetic fields evoked by word listening were generally distributed in bilateral temporoparietal areas with variable hemispheric dominance. Language tasks using visual stimuli frequently evoked magnetic field in posterior midline area, which made laterality decision difficult. Response during task resulted in more artifacts and different results depending on responding hand. Laterality decision with mean magnetic field strength was more concordant with Wada than the method with ECD number of each hemisphere. Conclusions: Word listening task without hand response is the most feasible paradigm for language lateralization using MEG. Mean magnetic field strength in each hemisphere is a proper index for hemispheric dominance.

  • PDF

자기장과 CIP 성분비 변화에 따른 MRE의 전단탄성계수에 대한 실험적 조사 (Experimental Investigation for Shear Modulus of MRE due to Magnetic Field and Volume Percent of CIP)

  • 윤지현;파와지;윤규서;정경호;오재응
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.753-753
    • /
    • 2008
  • Magneto-rheological elastomers(MRE) are similar to magnetorheological fluids. Thus, rheological properties of MRE can be also controlled by an applied magnetic field. The MRE in this experiment is a mixture of natural rubber(NR), carbonyl iron powder(CIP), ZnO, and sulfur. Three specimens were prepared and tested by using the vibration testing instruments. The magnetic field was generated by the electromagnets. Natural frequencies of the oscillator were changed by the applied magnetic field. The properties of the MRE were increased due to magnetic field strength.

  • PDF

Parallel-fed Multiple Loop Antenna for 13.56MHz RFID Reader

  • Yang Woon Geun;Park Yong Ju;Kim Hyuck Jin;Cho Jung Min;Kim Jung Ho
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 ICEIC The International Conference on Electronics Informations and Communications
    • /
    • pp.334-338
    • /
    • 2004
  • In this paper, we suggest a new antenna structure for RFID(Radio Frequency IDentification) reader. Conventional RFID reader uses a loop antenna. The central area of a loop antenna shows a low magnetic field strength especially for the case of a large loop antenna diameter. We propose a parallel-fed multiple loop antenna. Simulation results and measured results show that we can adjust field distribution with the number of turns and diameter of an inner loop antenna to obtain a longer reading distance. Simulation results for the specific case of a proposed antenna structure show that at the center point of a proposed parallel-fed multiple loop antenna, the typical card area averaged magnetic field strength is 2.53A/m, which is higher than the case of a conventional type single loop antenna of 0.44A/m and the case of a series-fed multiple loop antenna of 0.96A/m when we drive with same source signal. We realized the antenna for the case of 13.56MHz RFID reader and the performance of reading distance was much more improved than the case of a conventional antenna.

  • PDF

Statistical study on nightside geosynchronous magnetic field responses to interplanetary shocks

  • 박종선;김관혁;;이동훈;이은상;진호
    • 천문학회보
    • /
    • 제37권2호
    • /
    • pp.116.1-116.1
    • /
    • 2012
  • When an interplanetary (IP) shock passes over the Earth's magnetosphere, the geosynchronous magnetic field strength near the noon is always enhanced, while the geosynchronous magnetic field near the midnight decreases or increases. In order to understand what determines the positive or negative magnetic field response at nightside geosynchronous orbit to sudden increases in the solar wind dynamic pressure, we have examined 120 IP shock-associated sudden commencements (SC) using magnetic field data from the GOES spacecraft near the midnight (MLT = 2200~0200) and found the following magnetic field perturbation characteristics. (1) There is a strong seasonal dependence of geosynchronous magnetic field perturbations during the passage of IP shocks. That is, the SC-associated geosynchronous magnetic field near the midnight increases (a positive response) in summer and decreases (a negative response) in winter. (2) These field perturbations are dominated by the radial magnetic field component rather than the north-south magnetic field component at nightside geosynchronous orbit. (3) The magnetic elevation angles corresponding to positive and negative responses decrease and increase, respectively. These field perturbation properties can be explained by the location of the cross-tail current enhancement during SC interval with respect to geosynchronous spacecraft position.

  • PDF

송전철탑 주변에서 전장과 자장의 측정과 분석 (Measurement and Analysis of Electric and Magnetic Fields near a Transmission Tower)

  • 이복희;길형준;안창환;이경옥;박동화;곽희로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1827-1829
    • /
    • 1997
  • In this paper, measurement and analysis of ELF electric and magnetic fields due to a transmission line have been carried out and the power frequency field strength measuring system is designed. In order to evaluate electric and magnetic fields associated with 60 Hz electric power transmission and distribution lines, the actual survey near a transmission tower has been made and analyzed. It may be inferred from these results that the maximum electric and magnetic fields strength in the vicinity of a line tower do not exceed 3.5[kV/m] and 20[${\mu}T$]. The results of the field measurements agree with limits and guidelines recommended by various authorized international institutes.

  • PDF