• 제목/요약/키워드: magnetic field coil

검색결과 571건 처리시간 0.025초

자기공명영상을 위한 개방형 새장 고주파코일 (An Open Bridcage RF coil for Magnetic Rresonance Imaging)

  • 이수열;이정한;이완;문치웅;조민형
    • 전자공학회논문지S
    • /
    • 제35S권5호
    • /
    • pp.42-47
    • /
    • 1998
  • Bridcage RF coil is one of the most widely used RF coils in MRI. In order to use birdcage RF coils in open MRI systems, an open tructured birdcage RF coil has been investigated. By opening the ring structure of an original birdcage RF coil and driving the coil at two opening ends, the original birdcage RF coil can be modified to an open structured coil. In order to improve magnetic field uniformity of the open birdcage RF coil, driving voltage phases at the two opening ends can be controlled to be in-phase or out-of-phase each other. Operating frequency of the open birdcage RF coil has been theoretically derived, and the theoretical derivation has been verified by experiments.

  • PDF

Correction of resonance frequency for RF amplifiers based on superconducting quantum interference device

  • Lee, Y.H.;Yu, K.K.;Kim, J.M.;Lee, S.K.;Chong, Y.;Oh, S.J.;Semertzidis, Y.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제20권4호
    • /
    • pp.6-10
    • /
    • 2018
  • Low-noise amplifiers in the radio-frequency (RF) band based on the direct current (DC) superconducting quantum interference device (SQUID) can be used for quantum-limited measurements in precision physics experiments. For the prediction of peak-gain frequency of these amplifiers, we need a reliable design formula for the resonance frequency of the microstrip circuit. We improved the formula for the resonance frequency, determined by parameters of the DC SQUID and the input coil, and compared the design values with experimental values. The proposed formula showed much accurate results than the conventional formula. Minor deviation of the experimental results from the theory can be corrected by using the measured geometrical parameters of the input coil line.

심자도 측정을 위한 SQUID 센서 기술의 개발 현황 (Review of SQUID Sensors for Measuring Magnetocardiography)

  • 이용호;김진목;유권규;김기웅;권혁찬
    • Progress in Superconductivity
    • /
    • 제13권1호
    • /
    • pp.1-6
    • /
    • 2011
  • Measurement of magnetic signals generated from electric activity of myocardium provides useful information for the functional diagnosis of heart diseases. Key technical component of the magnetocardiography (MCG) technology is SQUID. To measure MCG signals with high signal-to-noise ratio, sensitive SQUID magnetic field sensors are needed. Present magnetic field sensors based on Nb SQUIDs have field sensitivity good enough to measure most of MCG signals. However, for accurate measurement of fine signal pattern or detection of local atrial fibrillation signals, we may need higher field sensitivity. In addition to field sensitivity, economic aspect of the SQUID system is also important. To simplify the SQUID readout electronics, the output voltage or flux-to-voltage transfer of SQUID should be large enough so that direct measurement of SQUID output can be done using room-temperature preamplifiers. Double relaxation oscillation SQUID (DROS), having about 10 times larger flux-to-voltage transfers than those of DC-SQUIDs, was shown to be a good choice to make the electronics compact. For effective cancellation of external noise inside a thin economic shielded room, first-order axial gradiometer with high balance, simple structure and long-baseline is needed. We developed a technology to make the axial gradiometer compact using direct bonding of superconductive wires between pickup coil and input coil. Conventional insert has mechanical support to hold the gradiometer array, and the dewar neck has equal diameter with the dewar bottom. Boiling of the liquid He can generate mechanical vibrations in the gradiometer array due to mechanical connection structure. Elimination of the mechanical support, and direct mounting of the gradiometer array into the dewar bottom can reduce the dewar neck diameter, resulting in the reduction of liquid He consumption.

자장감쇠법을 이용한 $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag 초전도선재의 접합저항 측정 (Measurement of Joint Resistance of $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag Superconducting Tape by Field decay Technique)

  • 김정호;이승묵;주진호
    • Progress in Superconductivity
    • /
    • 제14권1호
    • /
    • pp.1-10
    • /
    • 2012
  • We fabricated a closed coils by using resistive-joint method and the joint resistance of the coils were estimated by field decay technique in liquid nitrogen. We used the Runge-kutta method for the numerical analysis to calculate the decay properties. The closed coil was wound by $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag tape. Both ends the tape were overlapped and soldered to each other. The current was induced in a closed coils by external magnetic flux density. Its decay characteristic was observed by means of measuring the magnetic flux density generated by induced current at the center of the closed coil with hall sensor. The joint resistance was calculated as the ratio of the inductance of the loop to the time constants. The joint resistances were evaluated as a function of critical current of loop, contact length, sweep time, and external magnetic flux density in a contact length of 7 cm. It was observed that joint resistance was dependent on contact length of a closed coil, but independent of critical current, sweep time, and external magnetic flux density. The joint resistance was measured to be higher for a standard four-probe method, compared with that for the field decay technique. This implies that noise of measurement in a standard four-probe method is larger than that of field decay technique. It was estimated that joint resistance was $8.0{\times}10^{-9}{\Omega}$ to $11.4{\times}10^{-9}{\Omega}$ for coils of contact length for 7 cm. It was found that 40Pb/60Sn solder are unsuitable for persistent mode.

자기왜형 물질을 이용한 액츄에이터의 설계 및 특성해석 (Analysis and Design Actuator of Using Magnetostrictive Material)

  • 장석명;차상도;임채욱;정태영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.751-753
    • /
    • 2001
  • The characteristic of magnetostrictive is to change shape in a magnetic field, TERFENOL-D is said to produce magnetostriction. A magneto strictive actuator need to the magnetic circuit. The most important design consideration is the magnetic circuit. The magnetic circuit consists of the solenoid coil, permanets for bias and shaping of the other parts through which the magnetic field passes. A good magnetic circuit ensures the proper magnetic field in th TERFENOL-D and very uniform magnetic field in all phases of the actuator operating cycle. This paper presents magnetic circuit design and analysis uesing FEM.

  • PDF

알루미늄 가공 현장에서 금속 불순물 검출 (Detection of Metal Impurities at Aluminum processing factory)

  • 황종명;안부환;이장명
    • 로봇학회논문지
    • /
    • 제4권4호
    • /
    • pp.320-326
    • /
    • 2009
  • This paper proposed a new magnetic field detection algorithm to detect metal pieces in food producing processes. This algorithm can detect mixed metal pieces by sensing magnetic field. Some metal pieces are passed through an over-current circuit to magnetize them. The magnetic field sensor can detect the change in the magnetic field on theconveyor belt caused by the flow of the metal pieces in the food product. However, such a method detects the output of signals that change their amplitude and phase according to the movement of the conveyor belt with the food product, in which the equilibrium of the positive signal that is created in the receiver coil loses its balance due to the magnetized material. This includes not only the signal elements resulting from the effect of the alternating magnetic fields of the mixed metals, but also the signal elements resulting from the effect of the alternating magnetic fields of the examined object itself.

  • PDF

GMI Magnetic Field Sensor based on Time-coded Principle

  • Cao, Xuan-Huu;Son, De-Rac
    • 한국자기학회:학술대회 개요집
    • /
    • 한국자기학회 2009년도 정기총회 및 동계학술연구발표회
    • /
    • pp.217-219
    • /
    • 2009
  • A GMI magnetic field sensor working based on time-coded principle has been investigated and designed. The laboratory model has been constructed and tested carefully, demonstrating the sensitivity of $3\;{\mu}s/{\mu}T$ in the field range of ${\pm}100\;{\mu}T$. An amorphous thin wire, $100\;{\mu}m$ in diameter ${\times}50\;mm$ in length, was chosen to be sensing element which was fit into a small field modulation coil of 60 mm in length. The sensor is working based on a time-coded principle that, with the magnetic field modulation was chosen in range of hundreds of Hz, the change in time interval of two adjacent GMI peaks relating to external DC magnetic field is proportional to the intensity of the external field to be measured. This mechanism has made a great improvement to the linearity of the sensor.

  • PDF

A simulation-based design study of superconducting zonal shim coil for a 9.4 T whole-body MRI magnet

  • Kim, Geonyoung;Choi, Kibum;Park, Jeonghwan;Bong, Uijong;Bang, Jeseok;Hahn, Seungyong
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권1호
    • /
    • pp.12-16
    • /
    • 2020
  • As high homogeneity in magnetic field is required to increase the resolution of MRI magnets, various shimming methods have been researched. Using one of them, the design of the superconducting active zonal shim coil for MRI magnets is discussed in this paper. The magnetic field of the MRI magnet is expressed as the sum of spherical harmonic terms, and the optimized current density of shim coils capable of removing higher-order terms is calculated by the Tikhonov regularization method. To investigate all potential designs derived from calculated current density, 4 sweeping parameters are selected: (1) axial length of shim coil zone; (2) radius of shim coils; (3) exact axial position of shim coils; and (4) operating current. After adequate designs are determined with constraints of critical current margin and homogeneity criterion, the total wire length required for each is calculated and the design with a minimum of them is chosen. Using the superconducting wire length of 9.77 km, the field homogeneity over 50 cm DSV is improved from 24 ppm to 1.87 ppm in the case study for 9.4 T whole-body MRI shimming. Finally, the results are compared with the finite element method (FEM) simulation results to validate the feasibility and accuracy of the design.

A Review on the RF Coil Designs and Trends for Ultra High Field Magnetic Resonance Imaging

  • Hernandez, Daniel;Kim, Kyoung-Nam
    • Investigative Magnetic Resonance Imaging
    • /
    • 제24권3호
    • /
    • pp.95-122
    • /
    • 2020
  • In this article, we evaluated the performance of radiofrequency (RF) coils in terms of the signal-to-noise ratio (S/N) and homogeneity of magnetic resonance images when used for ultrahigh-frequency (UHF) 7T magnetic resonance imaging (MRI). High-quality MRI can be obtained when these two basic requirements are met. However, because of the dielectric effect, 7T magnetic resonance imaging still produces essentially a non-uniform magnetic flux (|B1|) density distribution. In general, heterogeneous and homogeneous RF coils may be designed using electromagnetic (EM) modeling. Heterogeneous coils, which are surface coils, are used in consideration of scalability in the |B1| region with a high S/N as multichannel loop coils rather than selecting a single loop. Loop coils are considered state of the art for their simplicity yet effective |B1|-field distribution and intensity. In addition, combining multiple loop coils allows phase arrays (PA). PA coils have gained great interest for use in receiving signals because of parallel imaging (PI) techniques, such as sensitivity encoding (SENSE) and generalized autocalibrating partial parallel acquisition (GRAPPA), which drastically reduce the acquisition time. With the introduction of a parallel transmit coil (pTx) system, a form of transceiver loop arrays has also been proposed. In this article, we discussed the applications and proposed designs of loop coils. RF homogeneous coils for volume imaging include Alderman-Grant resonators, birdcage coils, saddle coils, traveling wave coils, transmission line arrays, composite right-/left-handed arrays, and fusion coils. In this article, we also discussed the basic operation, design, and applications of these coils.

Under Water Sonar Transducer Using Terfenol-D Magnetostrictive Material

  • Son, Derac;Cho, Yuk
    • Journal of Magnetics
    • /
    • 제4권3호
    • /
    • pp.98-101
    • /
    • 1999
  • In this work we htave constructed an under water sonar transducer using Terfenol-D rod employing open magnetic circuit. Normally Sonar transducer using Terfenol-D was designed under closed magnetic flux return path, and permanent magnet for dc bias marnetic field, but high magnetic field should be applied to the transducer coil for high sound power and it brings temperature increase inside of the transducer. To improve this heat dissipation problem, we have designed an open magnetic circuit type transducer and we can get 200 dB (re. 1 Pa @ 1m) sound power for the input power of 650 VA.

  • PDF