• Title/Summary/Keyword: magnetic control

Search Result 2,272, Processing Time 0.041 seconds

Acromial Morphology in Different MR Oblique Sagittal Slices: Correlation with Rotator Cuff Disorder (자기 공명 영상의 사 시상면에서의 견봉 형태의 변화: 회전근 개 질환과의 임상적 연관성 분석)

  • Jo, Chris H.;Kim, Ji-Beom;Choi, Hye-Yeon;Ko, Young-Whan;Yoon, Kang-Sup;Lee, Ji-Ho;Kang, Seung-Baik;Lee, Jae-Hyup;Han, Hyuk-Soo;Rhee, Seung-Whan
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.173-179
    • /
    • 2009
  • Purpose: On the hypothesis that the acromion morphology is changed according to the its site, we identified the morphology of the acromion on the oblique slices of MRI and we investigated the association of the acromial shape with the clinical stages of rotator cuff disorder on the magnetic resonance (MR) images. In addition, we compared the acromion morphology on MRI and simple X-rays. Material and Methods: The MR images of seventy one patients with rotator cuff disorder and who underwent arthroscopic surgery were compared with that of a control group of sixteen patients who didn't have rotator cuff disorder on MRI. On three subsequent oblique sagittal slices from the lateral edge of the acromion (S1, S2 and S3), each acromion morphology on the MRI slices was classified according to Epstein et al: flat, curved or hooked. We investigated the changing parttern of the acromion shape and we compared the acromion shape on MRI and that on simple X-rays. We classified the rotator cuff tear by the severity: bursitis, partial thickness tear or full thickness tear. We investigated which acromial type on the MRI oblique slice was associated with the severity of rotator cuff disease. Results: Changes of the acromial shape occurred in 54 patients (76.1%). The most frequent pattern was that the types are same on S1 and S2 and different on S3 (22 cases, 31.0%). The acromial type on S1 and S2 was significantly associated with the severity of rotator cuff disorder (p=0.001 and 0.022), respectively. There was no reliability of the acromial shape on MRI and roentgenography (p>0.05) Conclusion: The type of acromion changed from lateral to medial. Among the three positions, the shape of the acromion on S1 and S2 had meaningful correlation with the clinical stage of rotator cuff disorder. There was no statistical correlation of the acromial shape between MRI and simple X-ray.

Ventilation Effect of the Greenhouse with Folding Panel Type Windows (패널굴절방식 환기창 온실의 환기효과)

  • Kim, Jin-Young;Lee, Si-Young;Kim, Hyun-Hwan;Chun, Hee;Yun, In-Hak
    • Journal of Bio-Environment Control
    • /
    • v.11 no.1
    • /
    • pp.5-11
    • /
    • 2002
  • In this study, new development of natural ventilation window was accomplished to control environment of greenhouse with no use of farced ventilation during hot season. The ventilation effect of developed ventilation window was investigated in experimental greenhouse which was designed using side wall panel and folding type panel fur natural ventilation. Folding panel type ventilation window was designed to open upper part of the side wall and top of the roof using two hinges which are located bottom of the side wall and the roof panel to grab one side of each panels and guide the other side along with the guidance rail. Developed ventilation window has top ventilation part with maximum moving distance X=ι (1-cos$\theta$)=848.5 mm and side ventilation part with maximum moving distance Y=ι/2 $\times$sin$\theta$=1,184.4 mm at 45$^{\circ}$ of theoretical opening angle. It took 4.5 minutes to open roof vent fully and temperature at 1.2 and 0.8 m height decreased after 1 minute from starting opening and became equilibrium state maintaining 3-4$^{\circ}C$ difference after 2 minutes from complete opening. Air exchange rate was 15.2~39.3 h$^{-1}$ which was more than 10~15 h$^{-1}$ of continuous type and Venlo type greenhouse. The descent effect of temperature by ventilation windows was two times higher than Venlo type greenhouse.

A Study on Enacting the Radiologic Technologist Act for the Civil Right to Health in Korea (건강권과 방사선사법 제정에 관한 고찰)

  • Lim, Chang-Seon
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.313-320
    • /
    • 2007
  • There are the Medical Radiation Health and Safety Act(the Patient Radiation Health and Safety Act, the Radiologic Technologist Act), the Medical Laboratory Technologist Act, the Physical Therapy Practice Act, and the Dental Hygienist Act, etc in America. However, Korea has only one Act for a medical radiologic technologist(including radiation therapy technologist, nuclear medicine technologist), medical laboratory technologist, physical therapist, occupational therapy examiner, dental hygienist, and so on. It is the Medical Technologist Act. Therefore, the Medical Radiation Health and Safety Act for a radiologic technologist(including radiation therapy technologist, nuclear medicine technologist) has to be enacted independently in Korea. It is the purpose of this Act to provide for the appropriate certification of persons using radioactive materials, equipment emitting ionizing radiation on humans or performing medical imaging for diagnostic and therapeutic purposes. In Korea, the radiologic technologist is a "fusion technologist" who is a person other than a licensed practitioner as a radiographer, radiation therapist, nuclear medicine technologist, computed tomography technologist, magnetic resonance technologist, mammographer, sonographer, medical dosimetrist, quality management technologist, etc. This Act will have some provisions related to the definitions, reserved title, scope of practice, specialized technologist, application for licensure, radiologic technology council, renewal, continuing education, the radiation control advisory commission, etc. This Act will ensure that quality radiation therapy treatments are delivered and that quality diagnostic information is presented for interpretation, which will lead to accurate diagnosis, treatment and cure. Accurate diagnosis can be provided only when a personnel is properly educated in technique, equipment operation and radiation safety. In the end, this Act will protect the civil right to health. By regulating the personnel responsible for performing those procedures, this Act will mean improved care for patients-higher quality images, improved accuracy, and less exposure to radiation.

  • PDF

The Giant Magnetoresistance Properties of CoFe/Cu/NiFe Pseudo Spin Valve (CoFe/Cu/NiFe Pseudo스핀밸브의 자기저항 특성)

  • Choi, W.J.;Hong, J.P.;Kim, T.S.;Kim, K.Y.
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.6
    • /
    • pp.212-217
    • /
    • 2002
  • The pseudo spin valve with a structure of Tl/CoFe(t $\AA$)/Cu(30 $\AA$)/NiFe(50 $\AA$)/Ta, showing giant magnetoresistance properties by utilizing coercivity difference between only two soft ferromagnetic layers were produced by d.c UHV magnetron sputtering system. In pseudo spin valve Ta/CoFe/Cu/NiFe/Ta, the magnetic and magnetoresistance properties with change of CoFe thickness were investigated. When the thickness of CoFe was 60 $\AA$, a typical MR curve of pseudo spin valve structure was obtained, showing MR ratio of 3.8 cio and the coercivity difference of 27.4 Oe with a sharp change of hard layer switching. When the CoFe thickness was varied from 20 to 100 $\AA$, coercivity difference between two layers was increased to 40 $\AA$. and decreased to 100 $\AA$ gradually. It is thought the change in coercivity of hard layer was due to the crystallinity and magnetostriction of thin CoFe layer. In order to improve the MR property in CoFe/Cu/NiFe trier layer structure, CoFe layer with change of 2-20 $\AA$ thick was inserted between Cu and NiFe. When the thickness of CoFe was 10 $\AA$, MR ratio was 6.7%, showing excellent MR property. This indicates 50 % higher than that of CoFe/Cu/NiFe pseudo spin valve.

An Experimental Study on the Effect of Half Sine-Wave Pulsed Electromagnetic Field in Orthodontic Tooth Movement (Half-sine Wave Pulsed Electromagnetic Fields가 교정적 치아 이동에 미치는 영향에 관한 실험적 연구)

  • Kim, Young-Joon
    • The korean journal of orthodontics
    • /
    • v.29 no.2 s.73
    • /
    • pp.157-163
    • /
    • 1999
  • The purpose of this study was to investigate the effect of electromagnetic field in orthodontic tooth movement, and the optimal application period of electromagnetic field to initiate tooth movement. Eighty male Hartley guinea pigs were utilized in this study. Laterally directed orthodontic force was applied to the maxillary central incisors. Half sine-wave pulsed electromagnetic field(HSPEMP) was applied to experimental group during 10 days. According to the period of application of HSPEMP(4 hours, 8 hours, 12 hours a day), they were divided into the three sub-groups The obtained results were as follows; 1. In case of application of HSPEMF during 4 hours a day, there was no significant difference in the final amount of orthodontic tooth movement between the experimental and the control group. 2. In case of application of HSPEMF during 8 and 12 hours a day, there was a significant increase in the final amount of orthodontic tooth movement since the eighth day, the sixth day respectively. 3. In comparison with the case of application of HSPEMF during 8 hours a day, there was a significant increase in the final amount of orthodontic tooth movement at the seventh day and the eighth day in case of application of HSPEMF during 12 hours a day.

  • PDF

The Design and Construction of the Nuclear Microprobe (핵 마이크로프로브 설계 및 제작)

  • Woo, Hyung-Ju;Kim, Jun-Gon;Choi, Han-Woo;Hong, Wan;Kim, Young-Seok;Lee, Jin-Ho;Kim, Ki-Dong;Yang, Tae-Gun
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.3
    • /
    • pp.380-386
    • /
    • 2001
  • A nuclear microprobe system with adjustable precision object slits and a magnetic quadrupole doublet was designed by the beam optics simulation using a first order matrix formalism, and installed in a $30^{\circ}$ beam line connected with KIGAM 1.7 MV Tandem VDG Accelerator. Demagnification factors for x and y axis are calculated to be 25 and 4.9, respectively, and a minimum beam spot side is expected to be about 5 $\mu\textrm{m}$ for 3 MeV proton beams with a current of about 1 nA. A multi-purpose octagonal target chamber has been built to facilitate MeV ion-beam analytical techniques of PIXE, RBS, ERDA, and ion beam micro-machining. It contains X-ray and particle detectors, a zoom microscope, a Faraday cup, a 4-axis sample manipulator and a high vacuum pumping system. The system performance of the nuclear microprobe is now being tested, and automatic manipulator control and data acquisition system will be installed for routine applications of micro ion-beam analytical techniques.

  • PDF

Working Memory Deficits in Patients with Schizophrenia:fMRI Investigation (정신분열병 환자의 작동기억 이상에 대한 기능적 자기공명영상 연구)

  • Park, Yuh-Jin;Kim, Tae-Suk;Roh, Sa-Bong;Pae, Chi-Un;Kim, Jung-Jin;Lee, Soo-Jung;Lee, Chul;Paik, In-Ho;Lee, Chang-Uk
    • Korean Journal of Biological Psychiatry
    • /
    • v.12 no.1
    • /
    • pp.32-41
    • /
    • 2005
  • Objective:Impaired processing of working memory is one of the cognitive deficits seen in patients with schizophrenia. This aimed at corroborating the differences in the brain activities involved in the process of working memory between patients with schizophrenia and the control subjects. Method:Fourteen patients with schizophrenia and 12 healthy volunteers were recruited in this study. Functional magnetic resonance imaging(fMRI) was used to assess cortical activities during the performance of a 2-back visual working memory paradigm using the Korean alphabet as mnemonic content. Results:Group analysis revealed that left lateral prefrontal cortex and right parietal lobule showed decreased cortical activities in the patient group. On the other hand, an increased activation in left superior and middle frontal gyrus, left middle temporal gyrus, right cuneus, both occipital lobes, right fusiform gyrus and right cingulate gyrus. The activation in left anterior lobe and both declive of cerebellum was also increased. Conclusions:This study showed a decreased activation in left lateral prefrontal and right parietal neural networks from the patient group and confirmed the earlier findings on the impaired working memory of patients with schizophrenia using fMRI investigation. The regions implicated in our study suggest an abnormal functioning of the fronto-parietal cortical areas that are critical to the information processing stream, which might be correspondent to common pathophysiology rather than a common etiology in schizophrenia.

  • PDF

Nanomaterials Research Using Quantum Beam Technology

  • Kishimoto, Naoki;Kitazawa, Hideaki;Takeda, Yoshihiko
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.10a
    • /
    • pp.7-7
    • /
    • 2011
  • Quantum beam technology has been expected to develop breakthroughs for nanotechnology during the third basic plan of science and technology (2006~2010). Recently, Green- or Life Innovations has taken over the national interests in the fourth basic science and technology plan (2011~2015). The NIMS (National Institute for Materials Science) has been conducting the corresponding mid-term research plans, as well as other national projects, such as nano-Green project (Global Research for Environment and Energy based on Nanomaterials science). In this lecture, the research trends in Japan and NIMS are firstly reviewed, and the typical achievements are highlighted over key nanotechnology fields. As one of the key nanotechnologies, the quantum beam research in NIMS focused on synchrotron radiation, neutron beams and ion/atom beams, having complementary attributes. The facilities used are SPring-8, nuclear reactor JRR-3, pulsed neutron source J-PARC and ion-laser-combined beams as well as excited atomic beams. Materials studied are typically fuel cell materials, superconducting/magnetic/multi-ferroic materials, quasicrystals, thermoelectric materials, precipitation-hardened steels, nanoparticle-dispersed materials. Here, we introduce a few topics of neutron scattering and ion beam nanofabrication. For neutron powder diffraction, the NIMS has developed multi-purpose pattern fitting software, post RIETAN2000. An ionic conductor, doped Pr2NiO4, which is a candidate for fuel-cell material, was analyzed by neutron powder diffraction with the software developed. The nuclear-density distribution derived revealed the two-dimensional network of the diffusion paths of oxygen ions at high temperatures. Using the high sensitivity of neutron beams for light elements, hydrogen states in a precipitation-strengthened steel were successfully evaluated. The small-angle neutron scattering (SANS) demonstrated the sensitive detection of hydrogen atoms trapped at the interfaces of nano-sized NbC. This result provides evidence for hydrogen embrittlement due to trapped hydrogen at precipitates. The ion beam technology can give novel functionality on a nano-scale and is targeting applications in plasmonics, ultra-fast optical communications, high-density recording and bio-patterning. The technologies developed are an ion-and-laser combined irradiation method for spatial control of nanoparticles, and a nano-masked ion irradiation method for patterning. Furthermore, we succeeded in implanting a wide-area nanopattern using nano-masks of anodic porous alumina. The patterning of ion implantation will be further applied for controlling protein adhesivity of biopolymers. It has thus been demonstrated that the quantum beam-based nanotechnology will lead the innovations both for nano-characterization and nano-fabrication.

  • PDF

THE APPEARENCE OF PROINFLAMMATORY CYTOKINES IN TEMPOROMANDIBULAR JOINT DISORDERS AFTER ARTHROCENTESIS AND LAVAGE (측두하악장애환자에서 악관절 세척술후 관절활액의 전구염증성 Cytokines의 발현)

  • Kim, Cheol-Hun;Hwang, Hie-Sung;Shin, Sang-Hoon;Chung, In-Kyo;Hwang, Tae-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.5
    • /
    • pp.370-378
    • /
    • 2005
  • The purpose of this study is that evaluate the distribution and biological roles of TNF-a, interleukin-1${\beta}$(IL-1${\beta}$), interleukin-6(IL-6) and tissue inhibitors of metalloproteinase-1(TIMP-1) in the synovial fliud of patients with non-inflammatory chronic temporomandibular joint(TMJ) disorders in relation to pain during joint movements and magnetic resonance imaging(MRI) findings. TMJ synovial fluids aspirates were obtained from 36 patients (36 joints) with chronic TMJ disorders and from 8 controls(8 joints). Patients were divided to four groups. The control group was from healthy volunteers(8 joints), group I(18 joints) was patients with anterior disc displacement with reduction, group II(5 joints) was patients with disc displacement without reduction and group III (5 joints) was osteoarthritis. The TNF-${\alpha}$, IL-1${\beta}$ and IL-6 levels in the aspirates were determined by using an enzyme-linked immunosorbent assay and the TIMP-1 level was measured by an enzyme immunoassay. Following examinations for pain during joint movements and MRI observations, these cytokines' level and frequencies of detection were compared. The level of IL-1${\beta}$was not significant different in all groups. but the level of TNF-${\alpha}$, IL-6 and TIMP-1 were significant different among groups. The level of IL-6 and TIMP-1 were correlated to pain during movement(p<0.01) and the level of TNF-a(p<0.05). Also, the level of IL-6 was correlated to the level of TIMP-1(p<0.01). Especially, The level of the TIMP-1 level was significantly correlated to the pain during movement and showed very high levle of Pearson's correlation coefficient (r=0.833)(p<0.001). The results indicated that the TNF-${\alpha}$, IL-6 and TIMP-1 levels in the TMJ aspirates of patients with chronic TMJ disorders have been raised. Especially, IL-6 and TIMP-1 were very high levels in the patients who were degraded in the TMJ. Also, TNF-${\alpha}$, IL-6 and TIMP-1 showed the significant correlation in the chronic temporomandibular joint disorders. Therefore I suggest that these cytokines were also correlated to the pain during movement in the chronic temporomandibular joint disorders.

Arthroscopic Management of the Triangular Fibrocartilage Complex Injuries (삼각 섬유 연골 복합체 손상의 관절경적 처치)

  • Moon Young Lae;You Jae Won;Oh Jong Ho;Jin Dae Sik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.1
    • /
    • pp.32-35
    • /
    • 2001
  • Purpose : To evaluate the efficacy of arthroscopic management of the triangular fibrocartilage complex(TFCC). Materials and Methods : Thirteen patients(14 wrists) with acute or chronic traumatic triangular fibrocartilage complex lesions were included in the study. The mean patients' age was 28.3 years, with a range of 21 to 45 years. All patients were diagnosed by physical examination, arthrographic or magnetic resonance imaging studies. Eight of the 14 wrists had central TFCC tear while 6 wrists had peripheral tear. Under arthroscopic control, injuries to the central portions were treated by debridement and excision of unstable tissue fragment while peripheral tears were repaired. The follow-up period averaged 28 months. The results were analyzed clinically using the Mayo modification of the Green and O' Brien wrist scoring system. Results : Nine of the 14 wrists were rated excellent,3 good and 2 fair Overall, 12 of the 14 patients rated as satisfactory and returned to sports or work activities. Conclusion : Arthroscopic treatment of TFCC resulted in a high degree of patient satisfaction and an increase in the ability to perform at workshop.

  • PDF