• Title/Summary/Keyword: m-factor

Search Result 8,669, Processing Time 0.044 seconds

Antigenicity Studies of M3S Tumor Necrosis Factor-$\alpha$(M3S TNF), a TNF Mutein (M3S Tumor Necrosis Factor-$\alpha$(M3S TNF)의 항원성)

  • 한형미;손경희;오현정;최경백;정승태;선우연;신남규;신항철
    • Toxicological Research
    • /
    • v.13 no.3
    • /
    • pp.203-208
    • /
    • 1997
  • The antigenic potential of M3S tumor necrosis factor-$\alpha$(M3S TNF), which is a mutated form of TNF(TNF mutein) designed to reduce adverse effects of wild type human TNF, was investigated in the present study. The antigenicity of M3S TNF was examined by conducting active systemic anaphylaxis (ASA) test in guinea pigs, heterologous(mouse-rat) passive cutaneous anaphylaxis(PCA) test and passive hemagglutination(PHA) test. The experimental animals were divided into low, medium, high and the highest dose groups and the groups with or without immunoadjuvant, sensitized according to the appropriate schedule and challenged. In ASA test, when challenged with 120 $\mu\textrm{g}$ /animal, moderate to severe positive anaphylactic responses were observed in groups sensitized with 12 $\mu\textrm{g}$ /animal, 120 $\mu\textrm{g}$ /animal and 120 $\mu\textrm{g}$ /animal+Freund's complete adjuvant. In PCA test, positive responses were observed in the group sensitized with the highest dose emulsified with an alum(12 $\mu\textrm{g}$ /animal+alum). In PHA test, positive responses were observed in the group sensitized with 3 $\mu\textrm{g}$ /animal emulsified with an alum. All the other groups in each experiment showed negative responses. Based on these results, M3S TNF is considered to have some antigenic potential.

  • PDF

Estimation of water unit factor and water demand of educational institutions (학교 용수 원단위 산정 및 용수 사용량 추정 방법에 관한 연구)

  • Kim, Tae-young;Huh, Dong;Park, Heekyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.4
    • /
    • pp.481-489
    • /
    • 2009
  • The objective of this research is to provide more reliable and accurate unit factor of water amount by investigating of informations related to various educational institutions such as elementary, middle, high schools and university. In order to estimate the water demand of educational institutions, first of all, the informations such as building area, site area, total school population, and water amount of various educational institutions are investigated to estimate the water unit factor. In this research, we used the total population of students and teachers to estimate the water demand of educational institutions. The results of unit factors of this research are as follows: 1) The elementary school is $0.027983m^3/person{\cdot}day$, 2) middle school: $0.024106m^3/person{\cdot}day$, 3) high school: $0.041415m^3/person{\cdot}day$, 4) specialized high school (science high school and foreign language high school): $0.156938m^3/person{\cdot}day$ and 5) university: $0.033766m^3/person{\cdot}day$. Finally, these water amounts calculated by unit factors were compared with real water amount of educational institutions.

A Mouse Thymic Stromal Cell Line Producing Macrophage-Colony Stimulating Factor and Interleukin-6

  • Lee, Chong-Kil;Kim, Jeong-Ki;Kim, Kyungjae;Han, Seong-Sun
    • Archives of Pharmacal Research
    • /
    • v.23 no.3
    • /
    • pp.252-256
    • /
    • 2000
  • A thymic stromal cell line, TFGD, was established from a thymic tumor mass developed spontaneously in p53 knock out mouse, and was found to produce cytokines that could induce bone marrow hematopoietic stem cells (HSCs) to differentiate into macrophages. The cytokines produced by the TFGD line were assessed by immunoassays. High level of macrophage-colony stimulating factor (M-CSF) and interleukin (IL)-6 was detected in the TFGD-culture supernatant, whereas granulocyte/macrophage-colony stimulating factor (GM-CSF), IL-3, IL-4, IL-5, IL-13, or interferon (IFN)-$\gamma$ was undetectable. Blocking experiments showed that anti-M-CSF monoclonal antibody could neutralize the differentiation-inducing activity shown by the TFGD-culture supernatant. Dot blot analysis of the total RNA isolated from the cultured fetal thymic stromal cells showed that M-CSF transcripts were expressed in the normal thymus. These observations, together with the earlier finding that M-CSF plus IL-6 is the optimal combination of cytokines for the induction of macrophage differentiation from HSCs in vitro, may indicate that thymic macrophages could be generated within the thymus by cytokines involving M-CSF.

  • PDF

Piezoelectric and Dielectric Properties of Low Temperature Sintered Pb(Mn1/3Nb2/3)0.02(Ni1/3Nb2/30.12(ZrxTi1-x)0.86O3 System Ceramics

  • Yoo, Ju-Hyun;Lee, Sang-Ho
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.4
    • /
    • pp.121-124
    • /
    • 2009
  • In this study, in order to develop compositions of ceramics suitable for piezoelectric actuator and ultrasonic vibrator applications using low temperature sintering, multilayer, PMN-PNN-PZT ceramics were fabricated using $Li_2CO_3$ and $Na_2CO_3$ as sintering aids. Their structural, piezoelectric and dielectric characteristics were investigated according to the Zr/Ti ratio. As the Zr/Ti ratio increased, the electromechanical coupling factor $k_p$, and piezoelectric constant $d_{33}$ and the mechanical quality factor $Q_m$ all increased with Zr/Ti ratio and then decreased after the ratio exceeded 50/50. At the ratio of Zr/Ti =49/51 and sintering temperature of $900^{\circ}C$; the density, electromechanical coupling factor $k_p$, dielectric constant ${\varepsilon}_r$ piezoelectric $d_{33}$ constant and mechanical quality factor $Q_m$ all showed the optimum values of 7.900 $g/cm^3$, 0.576, 856, 312 pC/N, 1,326, respectively. These property values are very suitable for multilayer ceramics actuator applications.

A Study on the Properties of the Low Temperature Sintered Piezoelectrics for Actuator Application (압전 액츄에이터에 활용할 저온소결 압전 세라믹스에 관한 연구)

  • Ryu, Sung-Lim;Lee, Sang-Ho;Yoo, Ju-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.3
    • /
    • pp.232-235
    • /
    • 2008
  • In this study, in order to develop the composition ceramics for multilayer piezoelectric actuator, PMN-PNN-PZT ceramics were fabricated using $Li_2CO_3$, $Na_2CO_3$, ZnO as sintering aids and their piezoelectric and dielectric properties were investigated according to the Bi substitution, Bi substitution induced grain growth and increase of sinterablity, And also, Bi substitution suppress secondary phase due to the liquid phase sintering effect. Bi substitution enhanced electromechanical coupling factor ($k_p$) and dielectric constant ($\varepsilon_r$), However, mechanical quality factor($Q_m$) was deteriorated, At the sintering temperature of 870 $^{\circ}C$ and Bi substitution of 1 mol%, density, electromechanical coupling factor ($k_p$), mechanical quality factor ($Q_m$), Dielectric constant ($\varepsilon_r$) and piezoelectric constant ($d_{33}$) of specimen showed the optimum values of 7,878 $g/cm^3$, 0,608, 835, 1603 and 397 pC/N, respectively for multilayer piezoelectric actuator application.

Eutrophication of Nakdong River and Statistical Analtsis of Envitonmental Factors (낙동강 부영양화와 수질환경요인의 통계적 분석)

  • Kim, Mi-Suk;Chung, Young-Ryun;Suh, Euy-Hoon;Song, Won-Sup
    • ALGAE
    • /
    • v.17 no.2
    • /
    • pp.105-115
    • /
    • 2002
  • Influences of vrious environmental factors on the eutrophication of Nakdong River were analyzed statistically using water samples collected from 1 January, 1999, to 30 September, 2001 at Namji area. The relationships between the concentration of chlorophyll α (eutrophication index) and environmental factors and were analyzed to develop a statistical model which can predict the status of eutrophication. The concentation of chlorophyll α ranged from 66.2 mg · $m^{-3}$ to 70.8 mg · $m^{-3}$ during dry winter season and the average concentration during this study period was 35.5 mg · $m^{-3}$ Namji area of Nakdong River was in the hypereutrohic stage in terms of water quality. Stephanodiscus sp. and Aulacoseria granulata var. angustissima were dominant species during the witnter to spring time and summer to autumn period, respectively. Based on the correlation analysis and the analysis of variance between chlorophyll α concentration and environmental factors, significantly high positive relationships were found in the order of BOD> pH> COD > KMnO₄ consumption > DO > conductivity > alkalinity. In contrast to these factors, significantly negrative relationships were found as in the order of $PO₄^{3-}-P$ >water level>the rate of Namgang-dam discharge > NH₃-N> the rate of Andong-dam discharge> the rate of Hapchoen-dam discharge. Based on the factors analysis of environmental factors on the concentration of chlorophyll α, we obtained five factors as follows. The first factor included water level, pH, turbiditiy, conductivity, alkalinity and the rate of Namgang-dam discharge. The second factor included water temperature DO, NH₄+-N, NO₃- -N. The third factor included KMnO₄ consumption COD and BOD. The fourth factor included the rate of Andong-dam discharge, the rate of Hapcheon-dam discharge, and the rate of Imha-dam discharge. The final factor included T-N T-P and $PO₄^{3-}-P$ > concentration. We derived two statistica models that can predict the occurrence of eutrophication based on the factors by factor analysis, using regression analysis. The first model is the stepwise regression model whose independent variables are the factors produced by factor analysis : chl α (mg · $m^{-3}$ = 42.923+(18.637 factor 3) + (-17.147 factor 1) + (-12.095 factor 5) + (-4.828 factor 4). The second model is the alternative stepwise regression model whose independent variables are the sums of the standardized main component variables:chl α (mg · $m^{-3}$ = 37.295+(7.326 Zfactor 3) + (-2.704 Zfactor 1)+(-2.341 Zfactor 5).

A Study on the Application of a Wind Power Generation System Using Outdoor Air on the Rooftop and Indoor Ventilation (건물 옥상외기와 실내배기를 활용한 풍력발전시스템 적용 연구)

  • Lee, Yong-Ho;Park, Jin-Chul;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.1
    • /
    • pp.72-80
    • /
    • 2014
  • This study proposed a wind power generation system utilizing outdoor air on the rooftop and indoor ventilation, which would increase according to the building height, as a way to help to save energy consumption in a building by using wind power energy of the new renewable energy sources. The study measured the distribution of air currents and power generation according to the usage factor of exhaust pipes in the kitchen and bathroom and identified the elements to consider when applying a wind power generation system to buildings in order to use outdoor air on the rooftop increasing according to the height and the indoor ventilation produced in the facility vertical shafts inside the buildings by installing a wind power generation system on the rooftop. (1) The study measured the ventilation velocity of the kitchen hood and bathroom ventilation fan by changing the zone areas by the households according to the usage factor of [${\alpha}$]=33~100%. As a result, the kitchen ventilation pipe generated the ventilation wind of 3.0m/s or more at the usage factor of [${\alpha}$] 66% or higher, and the bathroom ventilation pipe generated ventilation velocity lower than 3.0m/s, the blade velocity of the wind power generator, even after the usage factor rose to [${\alpha}$]=100%. (2) As the old bathroom ventilation pipe generated the ventilation velocity of 3.0m/s, the blade velocity of the wind power generator, even with the rising usage factor [${\alpha}$], the application of an outdoor air induction module increased the ventilation velocity by 2.9m/s at the usage factor of [${\alpha}$]=33%, 3.8m/s at the usage factor of [${\alpha}$]=66%, and 3.6m/s at the usage factor of [${\alpha}$]=100%. Thus the ventilation velocity of 3.0m/s, the blade velocity of the wind power generator, or higher was secured. (3) The findings prove that the applicability of a wind power generation system using outdoor air on the rooftop and indoor ventilation is excellent, which raises a need for various efforts to increase the possibility of its commercialization such as securing its structural stability according to momentary gusts on the rooftop and typhoons in summer and making the structure light to react to the wind directions of outdoor air on the rooftop according to the seasons.

[2,3]-FACTORS IN A 3-CONNECTED INFINITE PLANAR GRAPH

  • Jung, Hwan-Ok
    • Journal of applied mathematics & informatics
    • /
    • v.10 no.1_2
    • /
    • pp.27-40
    • /
    • 2002
  • For two integers m, n with m $\leq$ n, an [m,n]-factor F in a graph G is a spanning subgraph of G with m $\leq$ d$\_$F/(v) $\leq$ n for all v ∈ V(F). In 1996, H. Enomoto et al. proved that every 3-connected Planar graph G with d$\_$G/(v) $\geq$ 4 for all v ∈ V(G) contains a [2,3]-factor. In this paper. we extend their result to all 3-connected locally finite infinite planar graphs containing no unbounded faces.

항산화제와 Growth Factor 첨가가 돼지 체외수정란의 체외발육에 미치는 효과

  • 최영진;박진기;장원경;박춘근;정희태;김정익;장현용;양부근
    • Proceedings of the KSAR Conference
    • /
    • 2002.06a
    • /
    • pp.44-44
    • /
    • 2002
  • 본 연구는 돼지의 미성숙 난포란을 체외에서 성숙, 수정시킨 후, 생산된 체외 수정란을 NCSU 23 체외배양액에 항산화제(NAC, ebselen 및 glutathione) 와 성장 인자 (EGF, PDGF)의 첨가가 돼지 체외 수정란의 체외 발육에 미치는 영향을 검토하였다. NAC을 0, 0.5, 1.0 및 2.0 mL 첨가하여 체외배양한 결과, 상실배기 이상 발육된 체외발육성적이 1.0mL과 2.0 mM 첨가구가 여타구보다 유의하게 높은 체외발육성적을 나타냈다.(p〈0.05). (중략)

  • PDF

A Study on the Q-Factor Characteristics of Integrated Inductors Array (박막 인덕터 어레이의 Q-Factor 특성에 관한 연구)

  • Kim, In-Sung;Min, Bok-Ki;Song, Jae-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.2105-2107
    • /
    • 2004
  • In this study, Spiral inductors on the $SiO_2$/Si(100) substrate were fabricated by the magnetron sputtering method. Cu thin film with the thickness of 2 ${\mu}m$ was deposited on the substrate. Also we fabricated square inductors through the wet chemical etching technique. The inductors are completely specified by the turn width and the spacing between spirals. Both the width and spacing between spirals were varied from 10 to 60 ${\mu}m$ and from 20 to 70 ${\mu}m$, respectively. Inductance and Q factor dependent on the RF frequency were investigated to analyze performance of inductor arrays. Also, We recommend that the reasonable Q-factors, spec's turns and thickness of the coil for inductors cab be set to be ideal condition.

  • PDF