• Title/Summary/Keyword: lung function parameters

Search Result 66, Processing Time 0.021 seconds

Study on the Improvement of Lung CT Image Quality using 2D Deep Learning Network according to Various Noise Types (폐 CT 영상에서 다양한 노이즈 타입에 따른 딥러닝 네트워크를 이용한 영상의 질 향상에 관한 연구)

  • Min-Gwan Lee;Chanrok Park
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.93-99
    • /
    • 2024
  • The digital medical imaging, especially, computed tomography (CT), should necessarily be considered in terms of noise distribution caused by converting to X-ray photon to digital imaging signal. Recently, the denoising technique based on deep learning architecture is increasingly used in the medical imaging field. Here, we evaluated noise reduction effect according to various noise types based on the U-net deep learning model in the lung CT images. The input data for deep learning was generated by applying Gaussian noise, Poisson noise, salt and pepper noise and speckle noise from the ground truth (GT) image. In particular, two types of Gaussian noise input data were applied with standard deviation values of 30 and 50. There are applied hyper-parameters, which were Adam as optimizer function, 100 as epochs, and 0.0001 as learning rate, respectively. To analyze the quantitative values, the mean square error (MSE), the peak signal to noise ratio (PSNR) and coefficient of variation (COV) were calculated. According to the results, it was confirmed that the U-net model was effective for noise reduction all of the set conditions in this study. Especially, it showed the best performance in Gaussian noise.

Clinical Utility of Chest Sonography in Chronic Obstructive Pulmonary Disease Patients Focusing on Diaphragmatic Measurements

  • Hend M. Esmaeel;Kamal A. Atta;Safiya Khalaf;Doaa Gadallah
    • Tuberculosis and Respiratory Diseases
    • /
    • v.87 no.1
    • /
    • pp.80-90
    • /
    • 2024
  • Background: There are many methods of evaluating diaphragmatic function, including trans-diaphragmatic pressure measurements, which are considered the key rule of diagnosis. We studied the clinical usefulness of chest ultrasonography in evaluating stable chronic obstructive pulmonary disease (COPD) patients and those in exacerbation, focusing on diaphragmatic measurements and their correlation with spirometry and other clinical parameters. Methods: In a prospective case-control study, we enrolled 100 COPD patients divided into 40 stable COPD patients and 60 patients with exacerbation. The analysis included 20 age-matched controls. In addition to the clinical assessment of the study population, radiological evaluation included chest radiographs and chest computed tomography. Transthoracic ultrasonography (TUS) was performed for all included subjects. Results: Multiple A lines (more than 3) were more frequent in COPD exacerbation than in stable patients, as was the case for B-lines. TUS significantly showed high specificity, negative predictive value, positive predictive value, and accuracy in detecting pleural effusion, consolidation, pneumothorax, and lung mass. Diaphragmatic measurements were significantly lower among stable COPD subjects than healthy controls. Diaphragmatic thickness and excursion displayed a significant negative correlation with body mass index and the dyspnea scale, and a positive correlation with spirometry measures. Patients in Global Initiative for Chronic Obstructive Lung Disease (GOLD) group D showed lower diaphragmatic measurements (thickness and excursion). Conclusion: The TUS of COPD patients both in stable and exacerbated conditions and the assessment of diaphragm excursion and thickness by TUS in COPD patients and their correlations to disease-related factors proved informative and paved the way for the better management of COPD patients.

The Correlation between HRCT Emphysema Score and Exercise Pulmonary Testing Parameters (HRCT Emphysema Scoring과 운동부하 폐기능검사 지표들 간의 상관관계)

  • Choi, Eun-Kyoung;Choi, Young-Hee;Kim, Doh-Hyung;Kim, Yong-Ho;Yoon, Se-Young;Park, Jae-Seuk;Kim, Keun-Youl;Lee, Kye-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.4
    • /
    • pp.415-425
    • /
    • 2001
  • Background : The correlation between the high resolution computed tomography(HRCT) emphysema score and the physiologic parameters including resting and exercise pulmonary function test was investigated in 14 patients($60.6{\pm}10.3$ years) with pulmonary emphysema. Methods : The patients underwent a HRCT, a resting pulmonary function test, and incremental exercise testing(cycle ergometer, 10 W/min). Computed tomography scans were obtained on a GE highlight at 10 mm intervals using 10 mm collimation, from the apex to the base after a full inspiration. The emphysema scores were determined by a CT program 'Density mask' outlining the areas with attenuation values less than -900 HU, indicating the emphysema areas, and providing an overall percentage of lung involvement by emphysema. Results : Among the resting PFT parameters, only the diffusing capacity(r=-0.75) and $PaO_2$ (r=-0.66) correlated with the emphysema score(p<0.05). Among the exercise test parameters, the emphysema score correlated significantly with the maximum power(r=-0.74), maximum oxygen consumption(r=-0.68), anaerobic threshold(V-slope method: r=-0.69), maximal $O_2$-pulse(r=-0.73), and the physiologic dead space ratio at the maximum workload(r=-0.80)(p<0.01). Conclusion: We could find that exercise testing parameters showed a much better correlation with the HRCT emphysema score, which is known to have a good correlation with the pathologic severity than the resting PIT parameters. Therefore it is suggested that exercise testing is superior to resting PIT for estimating in the estimation of the physiologic disturbance in emphysema patients.

  • PDF

Obstructive Ventilatory Impairment as a Risk Factor of Lung Cancer (폐암의 위험인자로서의 폐쇄성 환기장애)

  • Kim, Yeon-Jae;Park, Jae-Yong;Chae, Sang-Cheol;Won, Jun-Hee;Kim, Jeong-Seok;Kim, Chang-Ho;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.4
    • /
    • pp.746-753
    • /
    • 1998
  • Background : Cigarette smoking is closely related to both lung cancer and chronic obstructive pulmonary disease. The incidence of lung cancer is higher in patients with obstructive ventilatory impairment than in patients without obstructive ventilatory impairment regardless of smoking. So, obstructive ventilatory impairment is suspected as an independent risk factor of lung cancer. Methods: For the evaluation of the role of obstructive ventilatory impairment as a risk factor of lung cancer, a total of 73 cases comprising 47 cases of malignant and 26 benign solitary pulmonary nodule were analyzed retrospectively. A comparative study of analysis of forced expiratory volume curves and frequencies of obstructive ventilatory impairment were made between cases with malignant and benign nodules. Results: In comparison of vital capacity and parameters derived from forced expiratory volume curve between two groups. VC, FVC and $FEV_1$ were not significantly different. whereas $FEV_1/FVC%$ and FEF 25-75% showed a significant decrease in the cases with malignant nodule. The frequency of obstructive ventilatory impairment determined by pulmonary function test was significantly higher in the cases with malignant nodule(23.4%) than in benign nodule(3.8%). When the risk for lung cancer was examined by the presence or absence of obstructive ventilatory impairment using the logistic regression analysis, the unadjusted relative risk for the lung cancer of obstructive ventilatory impairment was 17.17. When the effect of smoking and age were considered, the relative risk was to 8.13. Conclusion: These findings suggest that an obstructive ventilatory impairment is a risk factor of lung cancer.

  • PDF

Assessment of Treatment Response in Patients With Severe Asthma Using Visual and Quantitative Analysis of Chest CT

  • Han Na Lee;Jin An;Miji Lee;Hye Jeon Hwang;Jooae Choe;Jihye Yoon;Ji-Hyang Lee;Min-Hye Kim;Young-Joo Cho;Sang Min Lee;Tae-Bum Kim;Joon Beom Seo
    • Korean Journal of Radiology
    • /
    • v.25 no.7
    • /
    • pp.673-683
    • /
    • 2024
  • Objective: To evaluate the role of visual and quantitative chest CT parameters in assessing treatment response in patients with severe asthma. Materials and Methods: Korean participants enrolled in a prospective multicenter study, named the Precision Medicine Intervention in Severe Asthma study, from May 2020 to August 2021, underwent baseline and follow-up chest CT scans (inspiration/expiration) 10-12 months apart, before and after biologic treatment. Two radiologists scored bronchiectasis severity and mucus plugging extent. Quantitative parameters were obtained from each CT scan as follows: normal lung area (normal), air trapping without emphysema (AT without emph), air trapping with emphysema (AT with emph), and airway (total branch count, Pi10). Clinical parameters, including pulmonary function tests (forced expiratory volume in 1 s [FEV1] and FEV1/forced vital capacity [FVC]), sputum and blood eosinophil count, were assessed at initial and follow-up stages. Changes in CT parameters were correlated with changes in clinical parameters using Pearson or Spearman correlation. Results: Thirty-four participants (female:male, 20:14; median age, 50.5 years) diagnosed with severe asthma from three centers were included. Changes in the bronchiectasis and mucus plugging extent scores were negatively correlated with changes in FEV1 and FEV1/FVC (ρ = from -0.544 to -0.368, all P < 0.05). Changes in quantitative CT parameters were correlated with changes in FEV1 (normal, r = 0.373 [P = 0.030], AT without emph, r = -0.351 [P = 0.042]), FEV1/FVC (normal, r = 0.390 [P = 0.022], AT without emph, r = -0.370 [P = 0.031]). Changes in total branch count were positively correlated with changes in FEV1 (r = 0.349 [P = 0.043]). There was no correlation between changes in Pi10 and the clinical parameters (P > 0.05). Conclusion: Visual and quantitative CT parameters of normal, AT without emph, and total branch count may be effective for evaluating treatment response in patients with severe asthma.

Effect of Thyroid Hormone on the Ischemia-Reperfusion Injury in the Canine Lung (갑상선 호르몬이 잡견 폐장의 허혈-재관류 손상에 미치는 영향)

  • 김영태;성숙환
    • Journal of Chest Surgery
    • /
    • v.32 no.7
    • /
    • pp.637-647
    • /
    • 1999
  • Background: Ischemia-reperfusion injury is one of the major contributing causes of early graft failure in lung transplantation. It has been suggested that triiodothyronine (T3) may ameliorate ischemia-reperfusion injury to various organs in vivo and in vitro. Predicting its beneficial effect for ischemic lung injury, we set out to demonstrate it by administering T3 into the in situ canine ischemia-reperfusion model. Material and Method: Sixteen adult mongrel dogs were randomly allocated into group A and B. T3 $(3.6\mug/kg)$ was administered before the initiation of single lung ischemia in group B, whereas the same amount of saline was administered in group A. Ischemia was induced in the left lung by clamping the left hilum for 100 minutes. After reperfusion, various hemodynamic parameters and blood gases were analyzed for 4 hours while intermittently clamping the right hilum in order to allow observation of the injured left lung function. Result: Arterial oxygen partial pressure $(PaO_2)$ decreased 30 minutes after reperfusion and recovered gradually thereafter in both groups. In group B the decrease of $PaO_2$ was less marked than in group A. The recovery of $PaO_2$ was faster in group B than in group A. The differences between the two groups were statistically significant from 30 minutes after reperfusion $(125\pm34$ mmHg and $252\pm44$ mmHg, p<0.05) until the end of the experiment $(178\pm42$mmHg and $330\pm37$ mmHg, p<0.05). The differences in the arterial carbon dioxide pressure, airway pressure and lung compliance showed no statistical significance. The malondialdehyde (MDA) level, measured from the tissue obtained 240 minutes after reperfusion, was lower in group B $(0.40\pm0.04\mu$M) than in group A $(0.53\pm0.05\mu$M, p<0.05). The ATP level of group B $(0.69\pm0.07\mu$M/g) was significantly higher than that of group A $(0.48\pm0.07\mu$M/g, p<0.05). The microscopic exami nation revealed varying degrees of injury such as perivascular neutrophil infiltration, capillary hemorrhage and interstitial congestion. There were no differences in the microscopic findings between the two groups. CONCLUSION T3 has beneficial effects on the ischemic canine lung injury including preservation of oxygenation capacity, less production of lipid peroxidation products and a higher level of tissue ATP. These results suggest that T3 is effective in pulmonary allograft preservation.

  • PDF

10% Pentastarch Versus 5% Albumin Solution for Volume Expansion Following Cariopulmonary Bypass in Patients Undergoing Open Heart Surgery (개심수술후 혈량 증가를 위한 10% Pentastarch와 5% Albumin 용액의 비교연구)

  • 장병철
    • Journal of Chest Surgery
    • /
    • v.27 no.3
    • /
    • pp.177-186
    • /
    • 1994
  • Pentastarch is a hydroxyethyl starch similar to hetastarch, but lower average molecular weight and fewer hydroxyethyl groups which result in enhanced enzymatic hydrolysis and faster renal elimination.This report was performed to compare the clinical efficacy and safety of 10 % pentastarch[Pentaspan , group I] for plasma volume expansion after open heart surgery with that of 5% albumin[Plasmanate, group II]. There were no statistically significant differences between the group I [n=18] and group II [n:19] in the preoperative parameters [age, sex, body weight] and operative parameters[bypass time, aorta cross clamping time]. During the first 24 hours after arrival of the patient in the surgical intensive care unit, colloid solution [500--1000 ml] was infused to maintain left atrial pressure of more than 8 mmHg, or cardiac index of 2.0 L/min/M2 of more. In results, there were 3 complications of hypotension immediately after infusion of 5 % albumin solution and 2 among the 3 patients were excluded for the study. However there was no complication after infusion of 10 % pentastarch solution. Hemodynamic responses to infusion was similar for both groups, although in group I a greater increase in both left atrial pressure[mean 1.8 versus 0.7 mmHg, p< 0.05] and right atrial pressure [mean 2.2 versus 1.7 mmHg, p < 0.05] was observed during infusion of the first 500 ml. There were no significant differences in any of the measured respiratory parameters[PaO2, intrapulmonary shunt, and effective lung compliance]. Homodilution with colloid significantly reduced hemoglobin [mean 1.2 versus 0.8 gm/dl], and serum protein and albumin level[total protein;4.8$\pm$ 0.5 versus 5.2 $\pm$0.5 gm/dl, p < 0.05: albumin: 3.2 $\pm$0.4 versus 3.6 $\pm$0.6 gm/dl, p < 0.05] by 6:00 AM on 1 day postoperatively, however there were no significant differences on 7 day postoperatively. The mean serum colloid osmotic pressure and osmolarity was similar in both group.There were no abnormal findings of liver function and kidney function in all the patients. There were no significant between-group differences in bleeding time, platelets, prothrombin time, activated partial thromboplastin time and amount of chest tube output measured on 1st and 7th postoperative day. These findings demonstrated that 10% pentastarch is more effective and safe for plasma volume expension than 5 % albumin solution with no adverse effects on coagulation. Also 10 % pentastarch is less expensive than 5 % albumin and it would appeare to be a reasonable first choice for plasma volume expansion.

  • PDF

Effects of Adamantyl Derivatives on Pharmacokinetic Behavior of Paclitaxel in Rats

  • Kim, Kyung Mi;Lee, Kyeong;Jang, Kyusic;Moon, Yae Seul;Lee, Hwa Jeong;Rhie, Sandy Jeong
    • Biomolecules & Therapeutics
    • /
    • v.25 no.5
    • /
    • pp.553-558
    • /
    • 2017
  • Paclitaxel (PTX) is one of the most frequently used anticancer agent for treating refractory ovarian cancer, metastatic breast cancer and non-small cell lung cancer. However, its oral administration is impeded by very low bioavailability (<5%) due to the P-glycopprotein (P-gp) efflux pump effect. This study investigated in vitro and in vivo P-gp inhibitory effects of adamantyl derivatives AC-603 and AC-786 in rats. Two adamantyl derivatives tested in this study increased the cytotoxicity of daunomycin (DNM) in P-gp overexpressed cell line by inhibiting P-gp efflux function. Pharmacokinetics of PTX with orally co-administered P-gp inhibitors were assessed in rats to improve PTX absorption. The pharmacokinetic parameters of PTX were determined in rats after intravenous (2 mg/kg) or oral (25 mg/kg) administration in the presence or absence of verapamil (a positive control), AC-603 or AC-786 (0.5 mg/kg or 5 mg/kg). Compared to control group (PTX alone), experimental groups (PTX with AC-603 or AC-786) significantly increased the area under the plasma concentration-time curve of PTX following oral administration by 1.7-2.2 fold. The volume of distribution and total clearance of PTX were decreased, while other parameters were not significantly changed. In conclusion, co-administration of AC-603 or AC-786 enhanced the relative bioavailability of orally administered PTX as compared to control.

Modeling the Controllable Parameters of Radon Environment System with Dose Sensitivity Analysis (실내 라돈환경계의 선량감도분석에 의한 제어매개변수 모델링)

  • Zoo, Oon-Pyo;Chang, Yi-Young;Kim, Kern-Joong
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.2
    • /
    • pp.41-54
    • /
    • 1991
  • This paper aimed to analyse dose sensitivity to the controllable parameters of indoor radon $(^{222}Rn)$ and its decay products (Rn-D) by applying the input~output linear system theory. Physical behaviors of $^{222}Rn\;&\;Rn-D$ were analyzed in terms of $(^{222}Rn)$ gas -generation, -migation and -infiltration to indoor environments, and the performance output-function, i. e. mean dose equivalent to Tracho-Bronchial (TB) lung region, was assessed to the following extented ranges of the controllable paramenters; a) the ventilation rate $constant({\lambda}_v)\;:\;0{\sim}50[h^{-l}].\;b)$ the attachment rate $constant({\lambda}_a)\;:\;0{\sim}500[h^{-l}].\;c)$ the unattached-deposition rate constant (${\lambda}^u_d)\;:\;0-50[h-l]$. A linear input-output model was reconstructed from the original models in literatures, as follows, which was modified into the matrices consisting of 111 nodal equations; a) indoor $^{222}Rn\;&\;Rn-D$ Behaviour; Jacobi-Porstendoerfer-Bruno model.

  • PDF

Reference values for respiratory system impedance using impulse oscillometry in healthy preschool children

  • Park, Jye-Hae;Yoon, Jung-Won;Shin, Youn-Ho;Jee, Hye-Mi;Wee, Young-Sun;Chang, Sun-Jung;Sim, Jung-Hwa;Yum, Hye-Yung;Han, Man-Yong
    • Clinical and Experimental Pediatrics
    • /
    • v.54 no.2
    • /
    • pp.64-68
    • /
    • 2011
  • Purpose: The normal values for lung resistance and lung capacity of children, as determined by impulse oscillometry (IOS), are different for children of different ethnicities. However, reference values there is no available reference value for Korean preschool children have yet to be determined. The aim of the present study was to determine the normal ranges of IOS parameters in Korean preschool children. Methods: A total of 133 healthy Korean preschool children were selected from 639 children (aged 3 to 6 years) who attended kindergarten in Seongnam, Gyeonggi province, Korea. Healthy children were defined according to the European Respiratory Society (ERS) criteria. All subjects underwent lung function tests using IOS. The relationships between IOS value (respiratory resistance (Rrs) and reactance (Xrs) at 5 and 10 Hz and resonance frequency (RF)) and age, height, and weight were analyzed by simple linear and multiple linear regression analyses. Results: The IOS success rate was 89.5%, yielding data on 119 children. Linear regression identified height as the best predictor of Rrs and Xrs. Using stepwise multiple linear regressions based on age, height, and weight, we determined regression equations and coefficients of determination ($R^2$) for boys ($Rrs_5=1.934-0.009{\times}Height$, $R^2$=12.1%; $Xrs_5=0.774+0.006{\times}Height-0.002{\times}Age$, $R^2$=20.2% and for girls $(Rrs_5=2.201-0.012{\times}Height$, $R^2$=18.2%; $Xrs_5=-0.674+0.004{\times}Height$, $R^2$=10.5%). Conclusion: This study provides reference values for IOS measurements of normal Korean preschool children. These provide a basis for the diagnosis and monitoring of preschool children with a variety of respiratory diseases.