• 제목/요약/키워드: lumogallion

검색결과 2건 처리시간 0.015초

루모갈리온, 슈퍼크롬 가넷 와이 및 그 알킬 유도체에 의한 염기성 의약품의 형광정량 (Fluorophotometric Determination of Basic Drugs with Lumogallion, Superchrome Garnet Y and Their Alkyl Derivatives)

  • 송만영;김동오;이은엽;안문규
    • 약학회지
    • /
    • 제37권3호
    • /
    • pp.209-215
    • /
    • 1993
  • Basic drugs could be extracted as ion-paired complexes with Lumogallion, Superchrome Garnet Y and their alkyl derivatives from aqueous acid solution, and then determined fluoro-metrically after addition of aluminum ion. The analysis was carried out as follows; To a 1 ml portion of basic drugs (10$^{-9}$~2$\times$0$^{-8}$mole/ml), 1ml of 0.01w/v% fluorescent reagent solution, and 10ml of dichloroethane are added. The mixture is stirred for 1 minute. After standing for a few minutes, the dichloroethane layer is transfered to 1 ml of 0.1w/v% Al(NO$_{3}$)$_{3}$ ethanol solution. After mixing, and standing for 30 minutes at room temperature, the fluorescence intensity is measured with each maximum excitation and emission wavelength. The reagent blank is run through the whole procedure. From the degree of enhancement of fluorescence intensity, hexyl and dodecyl lumogallion and Superchrome Garnet Y were judged to be the useful one of fluorescent reagent for basic drugs analysis.

  • PDF

이온교환체 전극을 이용한 베라파밀 정량 (Determination of Verapamil with ISE based on Ion Exchanger)

  • 이은엽;김동오;장승현;허문회;안문규
    • 약학회지
    • /
    • 제40권2호
    • /
    • pp.135-140
    • /
    • 1996
  • Ion-selective poly(vinyl chloride)(PVC) membrane electrodes for the determination of the calcium antagonist verapamil and its pharmaceutical preparations were described. Verapam il-superchrome garnet Y(SGY), lumogallion(LG), acid red 97(AR97), Dragendorff(DD) and Meyer reagent ion pairs were inverstigated as an electroactive compound for membrane electrode. Stable potentiometric response was obtained with azo dye at pH 6.5-4.0 and with DD, and Meyer reagent at pH 6.5-3.0. The best plasticizer was 49w/w% 2-nitrophenyl octyl ether for azo dye, and 65.3w/w% tri(n-butyl) citrate for DD and Meyer reagent. Potentiometric response slopes of optimized membrane electrodes based on SGY, LG, AR97, DD, and Meyer complex for verapamil were 52.49, 54.88, 50.81, 54.13 and 49.31 mV/dec., respectively. Lower limits of linear range were $1.0{\times}10^6M$ for SGY, LG, and AR97, while those for DD and Meyer reagent were $4{\times}10^{-6}M$. Detection limits for all these electrodes were $1{\times}10^{-5}M,\;4{\times}10^{-6}M,\;1.8{\times}10^{-6}M,\;8{\times}10^{-7}M,\;and\;1{\times}10^{-6}M$ with relative standard deviation of 2.56, 3.6, 3.96, 2.56, 3.20%, respectively.

  • PDF