• 제목/요약/키워드: luminol

검색결과 109건 처리시간 0.023초

A Metal Enhanced Flow-Injection Chemiluminescence Method for the Rapid Determination of Norfloxacin in Pharmaceutical Formulations and Serum Sample

  • Kamruzzaman, Mohammad;Ferdous, Taslima;Alam, Al-Mahmnur;Lee, Sang-Hak;Kim, So-Yeun;Kim, Young-Ho;Kim, Sung-Hong
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권2호
    • /
    • pp.639-644
    • /
    • 2011
  • A simple and highly sensitive chemiluminescence method to determine norfloxacin (NFLX) has been proposed by measuring the chemiluminescence (CL) intensities using a flow injection (FI) system. The CL intensity of the luminol-$H_2O_2$ system is strongly enhanced by the addition of Cu (II) in alkaline condition. The CL intensity is substantially increased after the injection of NFLX into the luminol-$H_2O_2$-Cu (II) system. The enhancement effect is attributed to a catalytic effect of Cu (II) due to the interaction with NFLX which forms a complex with the catalyst. Under the optimal conditions, the sensitizing effect of the CL intensity is proportional to the concentration of NFLX in the range of $1.5{\times}10^{-9}-5.9{\times}10^{-7}molL^{-1}$ (r = 0.9994) with a detection limit ($3{\sigma}$) of $2.98{\times}10^{-10}molL^{-1}$. The proposed method had good reproducibility with the relative standard deviation (RSD, n = 5) of 1.6% for $1{\times}10^{-7}molL^{-1}$ of NFLX. The possible reaction mechanism of the CL reaction is also discussed. This method has been successfully applied for the determination of trace amount of NFLX in pharmaceutical preparations and serum samples.

Simultaneous Measurements of Gaseous Nitrous Acid and Particulate Nitrite Using Diffusion Scrubber/Steam Chamber/Luminol Chemiluminescence

  • Chang, Won-Il;Choi, Jung-Ho;Hong, Sang-Bum;Lee, Jai H.
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권8호
    • /
    • pp.1525-1532
    • /
    • 2008
  • An instrument was developed for the simultaneous determination of gas- and aerosol-phase nitrous acid (HONO). Gaseous HONO (HONO(g)) was sampled by a diffusion scrubber and particulate nitrite ($NO_2\;^-$(p)) was collected by a particle growth chamber. The collected samples were analyzed in time-sharing manner, based on the peroxynitrite-induced luminol chemiluminescence. The automated system was found to be sensitive with 13 pptv of detection limit, fast with 4 min. of sampling frequency, and simple and affordable to construct and operate. The system was optimized by adjusting the experimental parameters. The system was applied to the field measurement of gas- and particle-phase HONO during the springtime of 2004 in Gwangju, South Korea. HONO(g) concentrations varied diurnally from 200 pptv around 3 P.M. to 800 pptv at 5 A.M. The variation of $NO_2\;^-$(p) was not significant with the maximum of 240 pptv at 11 P.M. and the minimum of 170 pptv at 4 P.M., not displaying distinct characteristics.

소노루미네센스를 이용한 액체정합층의 고출력 초음파에너지 전달특성 평가 (Evaluation of high power ultrasonic energy transmission characteristics of a liquid matching layer by using sonoluminescence)

  • 김정순;김해운;손진영;김무준
    • 한국음향학회지
    • /
    • 제40권5호
    • /
    • pp.408-416
    • /
    • 2021
  • 초음파 분산에 있어서 초음파의 방사면이 시료에 직접 닿는 것을 피하기 위해 액체시료는 유리용기에 의해 분리되어 음향매질에 의해 초음파 에너지를 받는다. 이와 같이 다층구조로 이루어진 음향시스템에서 초음파에너지의 전달효율은 중요한 요소이다. 본 연구에서는 다층구조로 이루어진 음향시스템에 있어서 프로필렌글리콜 용액을 액체정합층으로 사용하여 초음파에너지 전달효율을 개선하는 방법을 제안하였다. 제안된 방법에서는 란주반형 초음파 트랜스듀서와 루미놀용액과의 사이에 프로필렌글리콜 용액을 액체정합층 매질로 채우고, 초음파트랜스듀서로부터 방사되는 강력초음파의 비선형현상에 의해 발광되는 루미놀용액의 발광정도를 광전증폭관을 이용하여 관측하여 루미놀용액으로의 초음파에너지 전달 효율을 조사하였다. 프로필렌글리콜 농도변화에 따른 초음파에너지 전달정도를 측정하였고, 그 결과 프로필렌글리콜 용액의 농도가 증가함에 따라 정합효과는 증가하는 반면 음향감쇠가 증가함을 알 수 있었다. 이들 두 상충되는 조건이 절충되는 최적의 농도가 존재함을 확인할 수 있었으며, 프로필렌글리콜 용액의 최적 농도를 실험적으로 결정할 수 있었다.

Chemiluminescence immunochromatographic analysis for the quantitative determination of algal toxins

  • Pyo, Dongjin;Kim, Taehoon
    • ALGAE
    • /
    • 제28권3호
    • /
    • pp.289-296
    • /
    • 2013
  • For the quantitative detection of algal toxin, microcystin, a chemiluminescence immunochromatographic assay method was developed. The developed system consists of four parts, chemiluminescence assay strip (nitrocellulose membrane), horse radish peroxidase labeled microcystin monoclonal antibodies, chemiluminescence substrate (luminol and hydrogen peroxide), and luminometer. The performance of the chemiluminescence immunochromatographic assay system was compared with high performance liquid chromatography (HPLC) detection. The detection limit of chemiluminescence immunochromatographic assay system is several orders of magnitude lower than with HPLC. The chemiluminescence immunochromatography and HPLC results correlated very well with the correlation coefficient ($r^2$) of 0.979.

실시 측정시스템을 활용한 실내 환경에서 HONO 농도 조사 (Application of an In-situ Measurement System to Determine HONO Levels in an Indoor Environment)

  • 홍진의;이재훈;박승식
    • 한국대기환경학회지
    • /
    • 제23권2호
    • /
    • pp.191-202
    • /
    • 2007
  • We developed an in-situ analyzer to understand the HONO levels in indoor environments. The in-situ measurement system utilizes a diffusion scrubber and luminol chemiluminescence to measure the HONO concentration with time resolution of 4-minute. Concentrations of NO, $NO_{2}$, and HONO were determined at an indoor air of an apartment for 9 days using the developed in-situ analyzer. Indoor HONO concentrations were highly elevated when a gas range was operated. Enhancements of the indoor NO, $NO_{2}$, and HONO concentrations during combustion indicate that the observed indoor HONO was formed by direct emission. In addition to the direct emission, the indoor HONO was partially generated from heterogeneous reactions of $NO_{2}$ on indoor surfaces, which was supported by strong relationships between peak NO, $NO_{2}$, and HONO concentrations, high HONO/$NO_{2}$ ratio and a weak correlation between NO and HONO concentrations. Additionally, three combustion experiments during the whole measurement period were performed to investigate the effects of unvented and vented gas burning on the HONO, NO, and $NO_{2}$ concentrations and their decay. The decay rate of the HONO concentration was significantly less than the NO and $NO_{2}$ decay rates for all the experiments, indicating that the lifetimes of trace nitrogen species in indoor environment varied in the order approximately HONO>$NO_{2}$>NO.

Study on the Inclusion Behavior of Sulfobutylether-β-Cyclodextrin with Perphenazine by Flow Injection Chemiluminescence

  • Shen, Minxia;Lv, Hairu;Song, Zhenghua
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권11호
    • /
    • pp.3199-3205
    • /
    • 2013
  • The inclusion behavior of sulfobutylether-${\beta}$-cyclodextrin (SBE-${\beta}$-CD) with perphenazine (PPH) was first studied by flow injection (FI)-chemiluminescence (CL) analysis with proposed $lg[(I_0-I_s)/I_s]=lgK_{P-CD}+nlg[C_{PPH}]$ model and molecular docking. Results showed that a 1:1 complex of SBE-${\beta}$-CD/PPH could online form, with the formation constant $K_{P-CD}$ of $2.57{\times}10^7Lmol^{-1}$ at 298 K. The thermodynamic parameters showed that the inclusion behavior of SBE-${\beta}$-CD/PPH was a spontaneous process by hydrophobic interaction. The molecular docking results revealed PPH entered into the larger cavity of SBE-${\beta}$-CD with two hydrogen bonds. Based on the linear relationship of the decrement of luminol/SBE-${\beta}$-CD/PPH CL intensity against the logarithm of PPH concentration ranging from 0.03 to 30.0 ng $mL^{-1}$, the present FI-CL analysis using luminol/SBE-${\beta}$-CD/PPH system was successfully applied to PPH determination in biological fluids and tablets with recoveries from 94.5 to 105.6% and RSDs less than 2.6% (n = 5).

화학발광법에 의한 전혈 중의 당 정량 (Determination of Glucose in Whole Blood by Chemiluminescence Method)

  • 이상학;최상섭
    • 대한화학회지
    • /
    • 제45권3호
    • /
    • pp.223-229
    • /
    • 2001
  • 흐름주입 장치를 이용하여 화학발광법에 의한 전혈 중의 당을 정량하는 방법에 대하여 연구하였다. 당의 효소반응에서 생성되는 과산화수소에 의하여 424nm에서 발생하는 luminol의 화학발광 세기의 차이를 정량에 이용하였다. 효소반응기는 glucose oxidase를 aminopropyl glass bead에 혼입하여 만들었으며, 흐름셀에서 발생하는 화학발광의 세기는 광섬유 다발을 이용하여 측정하였다. 최적 실험조건을 구하기 위하여 화학발광 시약 및 효소반응기의 pH, 흐름속도 및 온도가 화학발광세기에 미치는 영향을 조사하였다. 최적실험조건에서 구한 검정 곡선은 $1.0{\times}10^{-1}$~ 7.0mM에서 직선성이 성립하였으며, 검출한계는 $6.0{\times}10^{-2}$mM이었다. 본 방법을 전혈 중의 당 정량에 적용하였으며, 그 결과를 기존의 분석법에서 구한 결과와 비교하였다. 또한, 회수율 측정을 통하여 본 방법의 신뢰성을 검증하였다.

  • PDF

창이초(蒼耳草)의 약용부위별(藥用部位別) 추출물이 항감염(抗感炎) 및 항종양(抗腫瘍) 면역반응(免疫反應)에 미치는 영향 (Effects of Herba, Radix, Fructus-xanthii Extract on the Immunities against infections Diseases and Tumors)

  • 조남준;송호준;신민교
    • 대한한의학회지
    • /
    • 제19권2호
    • /
    • pp.420-438
    • /
    • 1998
  • Herba Xanthii(HX), Radix Xantluii(RX) and Fructus Xanthii(FX) is one of the oriental medicine that has been used for the treatment of such infectious diseases and tumors. However, the mechanism of the drug is not investigated much. This study was done to know the effects of HX, RX and FX extract on the such innate immunities as phagocytic function and reactive radical formtions from phagocytes and the such acquired immunities as humoral and cell-mediated immunities. The followings are the results obtained from this study: 1. HX2 and FX1 groups increases the in vivo phagocytic activity of mononuclear phagocytes. 2. HXB, RXB, RXC, FXB and FXC groups increase the in vitro phagocytic activities. 3. RXB group stimulated the macrophages to produce nitric oxide in the presence of $interferon-{\gamma}$ $(IFN-{\gamma})$. 4. HX and RX whole groups increased the luminol-amplified reactive oxygen intermediate production in vivo. 5. HX whole and RX1, FX2 groups increased the lucigenin-amplified reactive oxygen intennediate production in vivo. 6. HXC group only increased the luminol-amplified reactive oxygen intermediate production in vitro. 7. HXB, FXB and FXC groups increased the lucigenin-amplified reactive oxygen intermediate production in vitro. 8. HX2, RX1 and FX whole groups increased the hemolysin formations from B cells. 9. HX, RX and FX whole groups significantly increased the rosette forming cells from the spleen. 10. HX, RX and FX whole groups significantly decreased the delayed-type hypersensitivity measured by footpad swelling. The above results demonstrate that HX, RX and FX has enhancing effects on innate immunity selectively and decreasing effects on delayed-type hypersensitivity of cell-mediated immunity according to medicinal part and diluted condition. This immunomodulating effects of HX, RX and FX might be responsible for the treatment of immune-mediated disorders.

  • PDF

Chemiluminescence System with Air Pump as a Sensor for Determination of Metal Levels in Rain

  • Hong, Hyuck-Gi;Lim, H.B.
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권12호
    • /
    • pp.1937-1940
    • /
    • 2005
  • A lab-made chemiluminescence system with air pump was developed for monitoring of some metal levels in rain. The air pump enabled injection of 17.7 $\mu$g samples into a glass cell filled with luminol-$H_2O_2$ reagent of typically 300 $\mu$L for chemiluminescence measurement. The monitored trend of total metal ions in the rain collected in our campus was compared with analytical results of each metal ion from GFAAS. The system was also demonstrated to determine $Cr^{6+}$ by reduction to $Cr^{3+}$ using $SnCl_2$. The limit of detection for $Cr^{6+}$ obtained by 4 measurements was 85.0 pg $mL^{-1}$ with a relative standard deviation of 3.4%. Although this system doesn’t have selectivity due to the characteristics of chemiluminescence, application of it to environmental monitoring as a sensor for some transition metal ions was demonstrated.

과산화수소 농도와 전극에 따른 전기화학발광 특성 (ECL properties for concentration of $H_2O_2$ and feature of electrodes)

  • 표성열;강문식;강철구;김형일;홍석인;민남기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1566-1568
    • /
    • 2002
  • 본 논문은 혈당, 콜레스테롤센서에 적용이 가능한 과산화수소($H_2O_2$) 검출방식인 전기화학발광(Electrochemiluminescence:ECL)법 사용에 필요한 전극특성에 관한 연구이다. 전기화학전극으로 Pt박막전극을 사용하였으며, luminol(5-amino-2, 3-dihydro-1, 4-phthala edione)과 과산화수소($H_2O_2$)의 반응으로 발생한 빛을 포토다이오드(photodiode)를 사용하여 전류를 측정하였다. 사용된 전극은 직사각형(rectangular-type), 교차형(interdigitated-type)의 두 가지 형태를 사용하여, 전극간의 거리와 면적에 따른 ECL특성을 측정하였다. ECL 발광 특성은 전극 면적이 증가함에 따라, 전극거리가 감소함에 따라 증가함을 관찰할 수 있었다.

  • PDF