• 제목/요약/키워드: luminance-response function

검색결과 7건 처리시간 0.03초

The Role of the Pattern Edge in Goldfish Visual Motion Detection

  • Kim, Sun-Hee;Jung, Chang-Sub
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제14권6호
    • /
    • pp.413-417
    • /
    • 2010
  • To understand the function of edges in perception of moving objects, we defined four questions to answer. Is the focus point in visual motion detection of a moving object: (1) the body or the edge of the object, (2) the leading edge or trailing edge of the object, (3) different in scotopic, mesopic and photopic luminance levels, or (4) different for colored objects? We measured the Optomotor Response (OMR) and Edge Triggering Response (ETR) of goldfish. We used a square and sine wave patterns with black and red stripes and a square wave pattern with black and grey stripes to generate OMR's and ETR's in the goldfish. When we used black and red stripes, the black leading edges stimulated an ETR under scotopic conditions, red leading edges stimulated an ETR under photopic conditions, and both black and red leading edges stimulated an ETR under mesopic luminance levels. For black and gray stripes, only black leading edges stimulated an ETR in all three light illumination levels. We observed less OMR and ETR results using the sine wave pattern compared to using the square wave pattern. From these results, we deduced that the goldfish tend to prefer tracking the leading edge of the pattern. The goldfish can also detect the color of the moving pattern under photopic luminance conditions. We decided that ETR is an intriguing factor in OMR, and is suitable as a method of behavioral measurement in visual system research.

Characterization of one Time-Sequential Stereoscopic 3D Display - Part I: Temporal Analysis -

  • Pierre, Boher;Thierry, Leroux;Collomb-Patton, Veronique
    • Journal of Information Display
    • /
    • 제11권2호
    • /
    • pp.57-62
    • /
    • 2010
  • A method of characterizing time-sequential stereoscopic 3D displays based on the measurement of the temporal behavior of the systems vs. the grey levels is proposed. An Nvidia 3D vision kit with a 3D-ready SAMSUNG 2233RZ LCD display is characterized in the paper. OPTISCOPE SA especially designed for the precise measurements of the luminance and temporal behavior of LCD displays was used. The transmittance and response time of the shutter glasses was first evaluated. Then the grey-to-grey response times of the display were measured. The 2D and 3D behaviors of the display were then compared. Finally, the temporal behavior of the complete system was modeled, and the grey-level variations on one view were deduced as a function of the synchronization and level of the other eye. The main sources of imperfection were identified and quantified, and a full computation of the system performances was done.

MTFA에 의한 칼라 CRT의 화질 평가 (Evaluation of color CRT monitor by MTFA)

  • 김태희
    • 한국광학회지
    • /
    • 제9권3호
    • /
    • pp.205-211
    • /
    • 1998
  • 칼라 CRT(cathode ray tube)의 화질을 평가하기 위하여 일차원 CCD(charge coupled-device)를 사용한 MTF(modulation transfer function)측정장치를 구성하였다. CCD의 분광감도와 화소의 크기와 간격을 고려하여 MTF 측정값을 보정하였다. Spot 크기, 비디오 대역폭, 새도우 마스크, 디스플레이 휘도, 그리고 주변 조명이 디스플레이의 미치는 영향에 대하여 연구하였다. 칼라 CRT 모니터에서 화면의 균일성과 주변 조명에 따른 화질 평가하였으며, 그 결과를 MTFA(modulation transfer function area)를 사용하여 나타내었다.

  • PDF

영상의학 검사 판독용 모니터 정도관리 Guiding Instrument 제작과 유용성 고찰 (A Study on Production and Its Usefulness of AAPM TG18 Guiding Instrument for Diagnostic Monitor QC)

  • 손기경;성동욱;정재호;강희두;류경남
    • 대한디지털의료영상학회논문지
    • /
    • 제10권1호
    • /
    • pp.21-28
    • /
    • 2008
  • Diagnostic display monitor QA according to AAPM TG18 is usually performed by PACS administrator, product manager and reading doctor, and for acceptance testing and periodic quality control evaluation, a combination of visual and quantitative tests can be used, as outlined in sections 5 and 6 of 'assessment of display performance for medical imaging systems'. Although many display tests can be performed visually, a more objective and quantitative evaluation of display performance requires special test tools. The required instruments vary in their complexity and cost, depending on the context of the evaluation(research, acceptance testing, or quality control) and how thorough the evaluation needs to be. Objective and reliable assessment of many display characteristics can be performed with relatively inexpensive equipment, So, we made 'AAPM TG18 guiding instrument' to ues variable purpose of the evaluation of 'geometrical distortions(quantitative"', 'veiling glare(visual)' and 'sensor calibration'. The spatial measurements for the quantitative evaluation of geometric distortions, and the measurement of the veling-glare ring response function which provides information regarding the spatial extent of the luminance spread, can be performed using the TG18 guiding instrument can be used to sensor calibration to standardize the basic rate of 0% luminance when periodic calibration.

  • PDF

실제 클러터 배경에서 SAR 영상 임펄스 응답 특성 분석 (SAR Image Impulse Response Analysis in Real Clutter Background)

  • 정철호;정재훈;오태봉;곽영길
    • 대한원격탐사학회지
    • /
    • 제24권2호
    • /
    • pp.99-106
    • /
    • 2008
  • 영상 레이다(SAR)는 주야간, 일조량에 관계없이 전천후로 영상획득이 가능하여 군사용으로는 물론 과학 민수용으로 광범위하게 활용된다. SAR 시스템에서는 고도, 운용 주파수, PRF 등의 다양한 시스템설계 파라미터로부터 생성된 임펄스 응답 함수(impulse response function)를 분석하여 공간해상도, PSLR, ISLR 등 영상품질 성능 파라미터의 추정이 가능하다. 그러나 모델링된 임펄스 응답 특성은 주변 클러터 환경이 고러되지 않은 이상적인 경우이므로 실제 주변 클러터 환경을 고려한 SAR 영상품질 분석 기법이 필요하다. 본 논문에서는 먼저 주요 SAR시스템 파라미터를 기반으로 SAR 점표적 원시 데이터를 생성하고, 거리-도플러 알고리듬(range-Doppler algorithm)을 이용하여 임펄스 응답 데이터를 형성한다. 그리고 실제 SAR영상의 일부분을 추출하여 주변 배경 클러터 환경 데이터를 형성한 후, 임펄스 응답 데이터를 삽입한다. 형성된 응답 데이터는 영상품질의 정확도를 향상시키고자 확장보간법을 도입하여 분석하고, 이에 대한 효과를 주요 도플러 파라미터인 방위 FM율 오차에 따른 성능분석을 수행함으로써 확인한다.

Co-60 감마선을 이용한 광자극발광선량계의 재현성, 선형성, 선량의존성에 대한 특성평가 (Evaluation of Dosimetric Characteristics of Reproducibility, Linearity and Dose Dependence of Optically Stimulated Luminescence Dosimeters in Co-60 Gamma-rays)

  • 한수철;최상현;박승우;김철항;정해조;김미숙;유형준;김찬형;지영훈;이철영;김금배
    • 한국의학물리학회지:의학물리
    • /
    • 제25권1호
    • /
    • pp.31-36
    • /
    • 2014
  • 본 연구는 Co-60 감마선에서 광자극발광선량계(OSLD)의 재현성, 선형성 그리고 선량 의존성에 대한 특성평가를 수행하였으며, 기존의 방사선 치료 및 진단에서의 특성연구결과와 비교분석 하였다. 재현성에 대한 평가는 0.76%이며, 배치의 균질성은 1.5% 이내였다. 광자극발광선량계의 선형성 평가에서 3 Gy 이상의 선량에서는 상선형성이 나타나므로 조사된 선량과 카운트 값의 관계를 2차 함수에 적합하여 관계 모델을 만들었다. 반복적인 판독 횟수에 따른 카운트 값의 감소비율은 선량에 관계없이 1회당 0.04% 감소하였다. 방사선 조사 후 광자극발광선량계의 판독시간에 따른 카운트 값의 감쇠 곡선에서 반감기는 선량에 따라 0.68분(1 Gy), 1.04분(5 Gy), 1.10분(10 Gy)이였다. 소자를 30분간 광학적 어닐링 하였을 때 선량에 따라 지워진 정도는 88% (1 Gy), 90% (5 Gy), 92% (10 Gy)가 지워졌으며, 4시간 동안 어닐링 하였을 경우 선량에 관계없이 99%가 지워지는 것을 확인하였다. 광자극발광선량계를 사용하는 과정 사이에서 나타나는 불확도를 조사된 선량에 따라 고려한다면 Co-60 감마선에서 광자극발광선량계를 이용한 정확한 선량 평가가 가능할 것이다.