몬테칼로 시뮬레이션과 볼츠만 방정식을 이용한 저전압 기중차단기의 전자수송계수 특성파악 (Analysis of Electron Transport Coefficients in Low Voltage Air Circuit Breaker Using MCS and BE)

  • 하성철;서상현
    • 한국전기전자재료학회논문지
    • /
    • 제16권2호
    • /
    • pp.168-172
    • /
    • 2003
  • The electron transport coefficients in Air is analysed in range of E/Nvalues from 100~1000(Td) by a MCS and BE method. This paper have calculated W, ND$\sub$L/, ND$\sub$T/, Mean energy mixtures by N$_2$+O$_2$. The results gained that the values of the electron swarm parameters such as the electron drift velocity, longitudinal and transverse diffusion coefficients.

고정밀 전류센서를 이용한 저압배전계통 이중 보호용 전기화재 방재장치 (Electrical Fire Disaster Prevention Device of Double Protection using a High Precision Current Sensor in Low Voltage Distribution System)

  • 곽동걸;정도영
    • 한국화재소방학회논문지
    • /
    • 제23권3호
    • /
    • pp.40-47
    • /
    • 2009
  • 오늘날 전기제품의 다양화, 대용량화와 더불어 전기화재의 발생이 점차 증가하고 있다. 반면 저압 배전계통에서 사용되고 있는 기존의 과부하겸용 누전차단기 즉, RCD의 저조한 응답특성으로 인한 전기화재 원인의 대부분을 차지하는 단락사고 및 과부하사고에 대한 대응이 매우 미흡한 실정이다. 이에 본 논문에서는 기존 RCD에 대한 모의 사고실험을 통하여 그 비신뢰성을 확인하고, 이러한 RCD의 단점을 개선하고자 고정밀 전류센서를 이용한 전기화재 방재장치를 제안하여 저압 배전계통에서의 단락 및 과부하사고로 인한 전기재해를 방지하고자 한다. 제안한 장치의 고정밀 전류센서로 사용된 리드스위치는 각종 전기사고에서 수반되는 단락전류 및 과전류에 의한 배전선로의 상승된 자속을 정밀 감지한 후, 자체 차단장치를 동작시키거나 또는 기 설치된 RCD를 신속히 차단시키는 이중 보호용 제어 동작원리를 가진다. 다양한 동작특성 분석을 통해 기존의 차단기와 비교하여 차단동작 응답속도와 신뢰성이 입증된다. 이로써 제안한 전기화재 방재장치는 기존 RCD들의 빈번한 오동작과 비신뢰성, 저조한 응답특성으로 인한 각종 전기사고 및 전기화재의 발생을 방지하고자 한다.

345kV 고장전류 저감을 위한 한류리액터 설치시 차단기 TRV(모선 고장시) 검토 (A Study on the TRV(BTF) of Circuit Breakers According to Install Current Limit Reactors)

  • 곽주식;박흥석;심응보;유희영;이봉희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.368-370
    • /
    • 2005
  • Due to the tendency towards large capacity and complexity of power system, an enhancement of power system equipment make a system impedance to be low in power system. Generally if an equivalent impedance of system becomes lower, a system stability will be better. But the fault current becomes very larger. The 345kV ultra-high voltage system will use current limit reactors(CLR) in a transmission line or a bus in substation to limit the magnitude of fault current. The CLR makes a significant contribution to the severity of the transient recovery voltage(TRV) experienced by feeder and bus circuit breakers on clearing feeder faults. Based on the conclusions of an investigation of actual circuit breaker failures while performing this duty, the mitigation of the transient recovery voltage associated with the reactors is described. Therefore in this article we simulated the TRV by EMTP at Bus Terminal Fault.

  • PDF

Experimental Investigations Into Low Current Steady State Arcs In A Dual-Airflow Model Interrupter

  • Shin, Young-June;Cho, Yun-Ok;Kim, Jin-Gi;Lee, Jeong-Rim
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.961-965
    • /
    • 1992
  • It is well-known that shock waves frequently occur inside the nozzle of the interrupter, and that they play important roles in the arc interruption. A model interrupter with two-dimensional dual-airflow nozzles was used for this experiment. The arc was ignited with 1.4 mil copper wire stretched between the electrodes which were spaced out 56 mm. The arc current of 60 to 230 A was achieved by adjusting the external resistance from 5.5 to 1.6 ohms. The arc tests have been conducted for investigating the air arc characteristics, and the effects of shock waves and nozzle pressure ratios on the arc voltage, the arc resistance, the arc power, and average electric field. The results of these tests have been analyzed to provide insights into the arc characteristics for gas circuit breakers. The average electric field is represented by the function of the arc current to show the negative E-I characteristic explicitly. The effects of shock waves and nozzle pressure ratios are shown to be significant for a circuit breaker performance.

  • PDF

서지보호소자와 누전차단기 설치에 따른 기기의 뇌보호 효과 (The Protection Effect of Lightning Surge for electronic Equipments According to Installation of Surge Protective Device and Earth Leakage Breaker)

  • 이석우;고연성;여동구;서호준;이동희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.90-92
    • /
    • 2005
  • Lightning surge damages of low voltage equipments in building are increasing due to increase in electrical and communication networks in the information-oriented society. And electronic equipments contained electrical circuits with semiconductor are very weak against lightning surge. The surge protective devices for electronic circuit in electronic equipments and AC power lines are becoming more widely. To achieve effective method of surge protection, there are needs for correlation between lightning surge protective effect of electronic equipment and installation method of surge protective device. This paper describes as a result of experiments for correlation between lightning surge protective effect and installation of surge protective device and Earth Leakage Breaker.

  • PDF

인청동 스위칭 모듈을 이용한 전력계통 및 전자기기 내부회로의 MOV 열폭주 방지와 안전성 개선 (Thermal Runaway Prevention of MOV and Safety Improvement of Power Line System and Internal Electronic Device Circuit Using a Phosphorous Switching Module)

  • 김주철;최경래;이상중
    • 조명전기설비학회논문지
    • /
    • 제25권9호
    • /
    • pp.75-79
    • /
    • 2011
  • The MOV(Metal Oxide Varistor), a voltage limiting element, has been installed in the SPD(Surge Protective Device) or inside the internal circuit of an electronic appliance for protection of the electric power system and electronic device against electrical surge. Such an MOV is exposed, however, to the risk of the thermal runaway resulting from excessive voltage and deterioration. In this paper, a reciprocal action has been tested and analyzed using a phosphorus bronze switching module and the low-temperature solder. And a short current break characteristic test linked with the circuit breaker has been performed to limit the inrush current when the MOV breaks down. It has been proven that the phosphorus bronze switching module installed inside the internal circuit can improve the safety of the power line system and the electronic device.

디지털보호계전기를 이용한 기중차단기 제어 및 모니터링 (Control And Monitoring Of Air Circuit Breaker Using Digital Protective Relay)

  • 이성환;박상배;안인석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.240-242
    • /
    • 2001
  • On this research, to catch up with international trend on the power system utilities move to be digitalized and move to network is certainly technological on the global business world, to compete with advanced foreign countries in the range of transmit and distribute power system and to take possession of first market share within country, we talked over a monitoring system to diagnose, monitor ACB(Air Circuit Breaker) only which is operated on the low level voltage Power plant. AMS(ACB Monitoring System) have be configured with several modules such as engine module which acquire engineering data from HICM360/860(Communication Control Units) and analyze and save it, database module which restore data and can be inquired, system monitoring view module which reflects fields information within a second, realtime trend window, historical trend window, reports as daily and yearly. In a near future, AMS must upgrade GUI to have easy to handle and have to have a field test to fit on real plants, so it will have faith in system reliability as it can apply power plant monitoring system in wide.

  • PDF

실시간 Igr 검출을 위한 센서 모듈의 제작 및 신뢰성 평가에 관한 연구 (A Study on the Fabrication of the Sensor Module for the Detection of Resistive Leakage Current (Igr) in Real Time and Its Reliability Evaluation)

  • 이병설;최충석
    • 한국안전학회지
    • /
    • 제33권1호
    • /
    • pp.28-34
    • /
    • 2018
  • The purpose of this study is to fabricate a sensor module to detect the resistive leakage current (Igr) in real time that occurs to low voltage electric lines and to verify its reliability. In the case of the developed sensor module, wires are inserted into the zero current transformer (ZCT) and current transformer (CT) in advance and then the branch line is connected to the circuit breaker. The measurement result of the resistance of the distribution panel equipped with the developed sensor module shows that the resistance is $0.151m{\Omega}$ between the R and R phases, $0.169m{\Omega}$ between the S and S phases, and $0.178m{\Omega}$ between the T and T phases, respectively. The insulation resistance measured at AC 500 V and 1,000 V is $0.08m{\Omega}$ between the R, S, T and N phases, respectively. Then, the insulation resistance measured at DC 500 V is $83.3G{\Omega}$ between the R, S, T and G terminal, respectively. In addition, the applied withstanding voltage is AC 220 V/380 V/440 V and it was found that characteristics between all phases are good. This study measured the standby power by installing the developed sensor module at the rear of the MCCB and switching the circuit breaker on sequentially. The standby power is 1.350 W when one circuit breaker is turned on, 1.690 W when 2 circuit breakers are turned on, and 4.371 W when 10 circuit breakers are turned on. This study also verified the reliability of the standby power of the distribution panel equipped with the developed sensor module using the Minitab Program (Minitab PGM). Since the analysis shows the statistical average of 1.34627 in the reliable range of normal distribution, standard deviation of 0.001874, AD of 0.554, and P value of 0.140, it is found that the distribution panel equipped with the developed sensor module has high reliability.

특고압 가스 절연 부하 개폐기의 통합형 대전력 시험 방법 및 회로 구성에 관한 연구 (A Study on the Construction of Test circuit and Unification of Experiment Method for High Voltage Gas-insulated Load Switch using High Power Testing System)

  • 정흥수;김민영;김준석
    • 조명전기설비학회논문지
    • /
    • 제22권12호
    • /
    • pp.36-46
    • /
    • 2008
  • 본 논문은 대전력시험설비를 이용한 특고압 가스 절연 부하 개폐기의 대전력 시험회로의 구성과 통합형 시험 방법에 관하여 연구하였다. 대전력시험설비는 전기기기의 전기적 및 기계적인 성능을 검증하는 설비로서 단락발전기, 보호차단기, 투입스위치, 임피던스, 고압변압기, 저압변압기, 측정 및 보호시스템 등으로 구성되며, 이 시스템을 이용하여 단시간전류시험, 전류개폐용량시험, 단락투입 및 차단시험 등을 실시한다. 특고압 가스 절연 부하 개폐기의 규격으로는 국내 배전계통에 적용되는 ES(한국전력공사 표준규격) 5925-0002가 있으며, 국제 규격으로는 IEC 60265-1, 62271-1 및 IEEE C 37.74 등이 있다. 본 논문에서는 여러 규격에 각각 규정되어 있는 시험 절차, 시험회로 구성 및 시험 방법 등을 통합하여 600[MVA]급 대전력 시험설비에 적용하였다.

탠덤형 자석 소호기를 사용한 760V급 직류 개폐기의 차단 특성 (760 V-Class DC Switch Breaking Characteristics Using Tandem Type Magnet Extinguisher)

  • 김효성
    • 전력전자학회논문지
    • /
    • 제27권3호
    • /
    • pp.175-179
    • /
    • 2022
  • Magnetic arc extinguishing technology is effective as an extinguishing device for low-voltage direct current (DC) circuit breakers with a resistive load of ≤4 kW. The separation distance between the magnet and the electrical contact must be shortened to increase the magnetic arc extinguishing force. However, if the magnet is installed too close to the electrical contact points, the magnet is exposed to high temperatures due to the arc current generated when the load current is cut off and the magnetism is lost. To solve this problem, the effective magnetic flux density at the electrical contact can be maintained high by placing the arc extinguishing magnet in a tandem structure with the electrical contact point between them, and the proper separation distance between the contact points and the magnet can be maintained. In addition, an electric arc extinguishing technology that emits arc energy using a series circuit of diode and resistor is used to suppress the continuous arc voltage generated by the inductive load. For the proposed circuit breaker, the breaking characteristics are analyzed through the breaking test for the DC load of the 760 V level, the load power of 4 kW, and the time constant of 5 ms, and an appropriate arc extinguishing design guideline is proposed.