• Title/Summary/Keyword: low-rise buildings

Search Result 385, Processing Time 0.026 seconds

Pseudo-DC Resistivity Survey for Site Investigation at Urban Areas with Ambient Electrical Noises (전기잡음 간섭이 있는 도심지 지역 탐사를 위한 유사직류 전기비저항 기법)

  • Joh, Sung-Ho;Kim, Bong-Chan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1C
    • /
    • pp.37-44
    • /
    • 2010
  • Recently, urban retrofit and extension, development of new buildings and facilities, and construction of underground structures like subway tunnels in urban areas give rise to significance of site investigation at urban areas. However, ambient electric noises, traffic vibrations, embedded objects work as obstacles to high-quality and accuracy in site investigation at urban areas. In this paper, a new technique called the pseudo-DC resistivity survey (in brief, PDC-R) was proposed to minimize the adverse effect of ambient electrical noises in resistivity survey. PDC-R technique utilizes an AC current with frequency range of 0.1 to 1.0 Hz rather than DC current, which is used for conventional resistivity survey. The motivation of using low-frequency AC current is to avoid 60-Hz components or its multiples in the resistivity survey which ambient noises are mostly composed of. The implementation of PDC-R technique also included the parametric study on skin effect, frequency effect and current-level effect, which led to the determination of optimal values of frequency and current level for PDC-R survey. The reliability and feasibility of PDC-R technique was verified through field tests, accompanied by the comparison with DC resistivity survey and CapSASW tests.

Analysis on the Shear Behavior of Existing Reinforced Concrete Beam-Column Structures Infilled with U-Type Precast Wall Panel (U형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 보-기둥 구조물의 전단 거동 분석)

  • Ha, Soo-Kyoung;Son, Guk-Won;Yu, Sung-Yong;Ju, Ho-Seong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.6
    • /
    • pp.18-28
    • /
    • 2015
  • The purpose of this study is to develop a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were performed on one unreinforced beam-column specimen and two reinforced specimens with U-type precast wall panels. The results were analyzed to find that the specimen with anchored connection experienced shear failure, while the other specimen with steel plate connection principally manifested flexural failure. The ultimate strength of the specimens was determined to be the weaker of the shear strength of top connection and flexural strength at the critical section of precast panel. In this setup of U-type panel specimens, if a push loading is applied to the reinforced concrete column on one side and push the precast concrete panel, a pull loading from upper shear connection is to be applied to the other side of the top shear connection of precast panel. Since the composite flexural behavior of the two members govern the total behavior during the push loading process, the ultimate horizontal resistance of this specimen was not directly influenced by shear strength at the top connection of precast panel. However, the RC column and PC wall panel member mainly exhibited non-composite behavior during the pull loading process. The ultimate horizontal resistance was directly influenced by the shear strength of top connection because the pull loading from the beam applied directly to the upper shear connection. The analytical result for the internal shear resistance at the connection pursuant to the anchor shear design of ACI 318M-11 Appendix-D, agreed with the experimental result based on the elastic analysis of Midas-Zen by using the largest loading from experiment.

Research Trends in Hybrid Cross-Laminated Timber (CLT) to Enhance the Rolling Shear Strength of CLT (CLT의 rolling shear 향상을 위한 hybrid cross laminated timber 연구 동향)

  • YANG, Seung Min;LEE, Hwa Hyung;KANG, Seog Goo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.49 no.4
    • /
    • pp.336-359
    • /
    • 2021
  • In this study, hybrid CLT research and development trends were analyzed to improve the low rolling shear strength of CLT, a large wooden panel used in high-rise wooden buildings. Through this, basic data that can be used in research and development directions for localization of CLT were prepared. As a way to improve the low rolling shear strength, the use of hardwood lamina, the change of the lamina arrangement angle, and the use of structural composite materials are mainly used. Rolling shear strength and shear modulus of hardwood lamina are more than twice as high as softwood lamina. It confirmed that hardwoods can be used and unused species can be used. Rolling shear strength 1.5 times, shear modulus 8.3 times, bending stiffness 4.1 times improved according to the change of the layer arrangement angle, and the CLT strength was confirmed by reducing the layer arrangement angle. Structural wood-based materials have been improved by up to 1.35 times MOR, 1.5 times MOE, and 1.59 times rolling shear strength when used as laminas. Block shear strength between the layer materials was also secured by 7.0 N/mm2, which is the standard for block shear strength. Through the results of previous studies, it was confirmed that the strength performance was improved when a structural wood based materials having a flexural performance of MOE 7.0 GPa and MOR 40.0 MPa or more was used. This was determined based on the strength of layered materials in structural wood-based materials. The optimal method for improving rolling shear strength is judged to be the most advantageous application of structural wood based materials with strength values according to existing specifications. However, additional research is needed on the orientation of CLT lamina arrangement according to the fiber arrangement of structural wood-based materials, and the block shear strength between lamina materials.

A Study on the Status of Low-rise Buildings (국내 저층 건축물의 현황에 관한 고찰)

  • Park, Hong-Shin
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.28-28
    • /
    • 2011
  • 국내의 건축물에 관한 통계정보는 국토해양부에 의해서 공표된 통계연보로서 2002년부터 매년마다 제공되고 있다.(국토해양통계누리, https : //stat.mltm.go.kr/potal/stat/yearReport.do) 건축물의 통계연보는 과거부터 2002년까지 매 3년마다 공표된 것으로 알려지고 있다. 이 통계연보에는 건축물 현황과 건축허가착공 통계가 수록되어 있다. 건축물 현황에는 2009년 말을 기준으로 기존 건축물이 전체 6,618,131동으로서 용도별, 층수와 연면적별 그리고 소유구분별 등의 구분에 따라 건축물의 동수에 관한 통계자료가 포함돼 있다. 건축허가 및 착공통계에는 용도별과 구조재료별의 분류에 따라 건축물의 동수에 관한 자료가 신축, 증축 개축 이전 대수선, 용도변경 등으로 분류되어 수록돼 있다. 한편 국내에서 건축물에 대한 내진설계기준이 1988년에 제정됨에 따라 법제화되었다. 이때 내진설계의 의무 대상건축물은 6층 이상 또는 연면적 1만$m^2$이상인 건축물로 규정되었다. 그 이후 내진설계 대상 건축물이 1996년부터 아파트는 5층 이상으로, 판매시설은 연면적 5천$m^2$이상으로 확대되었고, 2000년부터 숙박시설 오피스텔 및 기숙사는 5층 이상으로 확대되었으며, 2005년부터 내진설계 의무화 대상이 3층 이상 또는 1천$m^2$이상으로 확대되었고, 2009년부터 3층 이상 건축물의 구조안전의 확인을 위한 세부절차를 규정하여 내진설계의 실효성을 확보하고 있다. 이와 같이 내진설계의 대상 건축물이 내진설계기준을 제정한 이후 현재까지 시대의 흐름에 따라 6층 이상에서 5층 이상으로 다시 3층 이상으로 계속 확대되어왔다. 이런 환경에서 현재 시점에서 사용 중인 기존 건축물 중에 내진설계가 적용되지 아니한 건축물은 1988년 3월 1일 이전에 건축허가 된 건축물과 그 이후에 건축허가 된 3층 내지 5층 이하인 저층 건축물의 두 가지로 구분할 수 있다. 이들의 내진설계가 미적용 된 건축물에 대해서는 원칙적으로 내진보강 대책 수립 및 추진이 필요한 실정이다. 국내에서는 현재 지진재해대책법에 따라 지진재해로부터 국민의 생명과 재산을 보호하기 위하여 기존 시설물에 대한 내진대책을 추진하는 정책이 시행되고 있다. 앞으로는 이 정책의 일환으로 기존 건축물의 내진성능 확보를 위한 내진보강 대책이 구체적으로 추진될 전망이다. 이와 같이 기존 건축물에 대한 내진보강 대책을 수립하는 데는 무엇보다 그 대상 건축물의 수와 구조형식에 관한 정보가 필요하다. 이는 내진보강의 방법과 소요비용이 건축물의 층수 및 구조형식별 동수에 따라 크게 달라지기 때문이다. 이런 관점에서 살펴볼 때 내진대책의 수립에 필수인 기존 저층 건축물의 층수 및 구조형식별 동수에 관한 통계자료를 현재 건축물의 현황통계에서 손쉽게 찾아 볼 수 있으면 좋겠는데 현실은 그렇지 못한 실정이다. 현재 건축물의 현황통계에는 저층 건축물에 해당하는 층수에 관한 구분이 연대에 따라 다르고 구체적인 층수를 구분하기 어렵게 불분명한 항목으로 구성된 것과 구조형식별 분류항목이 없는 형편이다. 반면에 건축허가 및 착공통계자료에는 구조재료별 건축물 동수와 연면적에 관한 자료가 수록되어있고, 건축물 층수에 따라 분류된 통계자료는 없다. 이 연구에서는, 기존 건축물에 대한 내진보강 대책을 수립하는데 필요한 저층 건축물의 층수 및 구조재료별 동수 등에 관한 구체적인 정보를 파악하기 위하여, 건축물 통계연보에 수록된 건축물 현황통계자료에서 불명확하거나 결여된 정보를 건축허가 및 착공 통계자료로부터 얻은 정보로 보완과 보충하여 제시하고 있다. 따라서 이 연구는 기존 건축물의 내진보강 대책 수립에 필요한 5층 이하의 저층 건축물에 관한 층수별 및 구조형식별 동수에 관한 연도별 통계자료를 추정하여 제안하는데 그 목적이 있다.

  • PDF

Applicability of UAV in Urban Thermal Environment Analysis (도시 내 열환경 분석에서 무인항공기의 활용가능성)

  • Kang, Da-In;Moon, Ho-Gyeong;Sung, Sun-Yong;Cha, Jae-Gyu
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.46 no.2
    • /
    • pp.52-61
    • /
    • 2018
  • Urban heat islands occur due to increases in the extent of artificial surfaces such as concrete, asphalt and high-rise buildings. In this regard, research into the use of satellite thermal infrared images for thermal environment analysis of urban areas is being carried out. However, such analysis of the characteristics of individual land cover with low-resolution satellite images suffers from limitations because land cover patterns in urban areas are complicated. Recently, UAV has been widely used, which can compensate for this limitation as it is able to acquire high-resolution images. In this paper, the accuracy of UAV infrared images is verified and the applicability of UAV in urban thermal environment analysis is examined by comparing the results with land surface temperatures from Landsat 8 thermal images. The results show a high positive correlation of temperature values at 0.95, and no statistically significant difference between the two groups. Comparisons of land surface temperature according to land cover showed that the largest difference observed was $4.63^{\circ}C$ in the Used area, and UAV images with small cell units reflected various surface temperatures. Furthermore, it was possible to analyze the surface temperatures of various green spaces such as wetlands and street tree areas, which can lower surface temperatures in urban areas, with street tree shadows reducing surface temperatures by about $4-6^{\circ}C$. UAV can easily and rapidly measure the surface temperature of urban areas and is able to analyze various types of green spaces. Thus, this is an effective tool for thermal environment analysis in urban areas to aid in the design or management of urban green spaces, as it can allow for land cover and the effects of the various green spaces.