• Title/Summary/Keyword: low-field measurement

Search Result 562, Processing Time 0.027 seconds

Effective Volume of the Korea Research Institute of Standards and Science Free Air Chamber L1 for Low-Energy X-Ray Measurement

  • Chul-Young Yi;Yun Ho Kim;Don Yeong Jeong
    • Progress in Medical Physics
    • /
    • v.33 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • Purpose: To evaluate the effective volume of the Korea Research Institute of Standards and Science free air chamber (KRISS FAC) L1 used for the primary standard device of the low-energy X-ray air kerma. Methods: The mechanical dimensions were measured using a 3-dimensional coordinate measuring machine (3-d CMM, Model UMM 500, Carl Zeiss). The diameter of the diaphragm was measured by a ring gauge calibrator (Model KRISS-DM1, KRISS). The elongation of the collector length due to electric field distortion was determined from the capacitance measurement of the KRISS FAC considering the result of the finite element method (FEM) analysis using the code QuickField v6.4. Results: The measured length of the collector was 15.8003±0.0014 mm with a 68% confidence level (k=1). The aperture diameter of the diaphragm was 10.0021±0.0002 mm (k=1). The mechanical measurement volume of the KRISS FAC L1 was 1.2415±0.0006 cm3 (k=1). The elongated length of the collector due to the electric field distortion was 0.170±0.021 mm. Considering the elongated length, the effective measurement volume of the KRISS FAC L1 was 1.2548±0.0019 cm3(k=1). Conclusions: The effective volume of the KRISS FAC L1 was determined from the mechanically measured value by adding the elongated volume due to the electric field distortion in the FAC. The effective volume will replace the existing mechanically determined volume in establishing and maintaining the primary standard of the low-energy X-ray.

Development for Measurement Range Extension Technique of AC High Voltage Source using Parallel Plates Electrode and Electric Field Sensor (평행판 전극과 전기장 센서를 이용한 교류 고전압 발생원의 측정범위 확장기술 개발)

  • Kang, Jeon-Hong;Ryu, Jae-Cheon;Lee, Sang-Hwa;Kim, Kyu-Tae;Kim, Myung-Soo;Han, Sang-Ok;Jung, Jae-Kap
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.9
    • /
    • pp.446-451
    • /
    • 2006
  • The output voltage value of AC high voltage source has been usually measured by employing the high voltage divider of inductive or capacitive type. In the study, we have developed a new method for measuring the output voltage up to 60kV using parallel plates electrode and electric field sensor, which are constructed by home-made. Unlikely the conventional method using a high voltage divider, this developed method makes it possible to extend the range of output voltage from known low voltage measurement to high voltage measurement. From the linearity measured between electric field and applied voltage in the output voltage range of 1kV-30kV, the output voltage value up to 60kV can be obtained by the electric field measurement using the electric field sensor. The output voltage value obtained using the method is consistent with that obtained using high voltage divider within corresponding uncertainties.

Research on Importance-Performance Analysis of Smart Construction Safety Management System (스마트 건설안전관리시스템의 중요도-성과도 분석 연구)

  • Jong-Yil Park;Chang-Hee Yun
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.2
    • /
    • pp.43-53
    • /
    • 2024
  • This study analyzes the importance-performance analysis (IPA) of the 10 dimensions of the smart construction safety management system, and analyzes which dimensions are important and which dimensions are performing to determine key improvement tasks, incremental improvement tasks, Maintenance and reinforcement tasks and continuous maintenance tasks were derived. Among the 10 dimensions of the smart construction safety management system, the dimensions that are recognized as important by all field managers and field workers and have high performance are the automatic risk displacement measurement system, smart environmental sensor system, and heavy equipment seizure prevention system. However, areas that were perceived as having high importance but low performance were worker location tracking systems, smart safety helmet chin muscles, and smart safety ring fastening. Among the smart construction safety management systems perceived by field managers, areas for key improvement with high importance and low performance included worker location tracking system and smart safety ring fastening. Among the smart construction safety management systems perceived by field workers, the area for key improvement with high importance and low performance was the automatic risk displacement measurement system.

Statistical characteristics of sustained wind environment for a long-span bridge based on long-term field measurement data

  • Ding, Youliang;Zhou, Guangdong;Li, Aiqun;Deng, Yang
    • Wind and Structures
    • /
    • v.17 no.1
    • /
    • pp.43-68
    • /
    • 2013
  • The fluctuating wind induced vibration is one of the most important factors which has been taken into account in the design of long-span bridge due to the low stiffness and low natural frequency. Field measurement characteristics of sustained wind on structure site can provide accurate wind load parameters for wind field simulation and structural wind resistance design. As a suspension bridge with 1490 m main span, the Runyang Suspension Bridge (RSB) has high sensitivity to fluctuating wind. The simultaneous and continuously wind environment field measurement both in mid-span and on tower top is executed from 2005 up to now by the structural health monitoring system installed on this bridge. Based on the recorded data, the wind characteristic parameters, including mean wind speed, wind direction, the turbulence intensity, the gust factors, the turbulence integral length, power spectrum and spatial correlation, are analyzed in detail and the coherence functions of those parameters are evaluated using statistical method in this paper. The results indicate that, the turbulence component of sustain wind is larger than extremely strong winds although its mean wind speed is smaller; the correlation between turbulence parameters is obvious; the power spectrum is special and not accord with the Simiu spectrum and von Karman spectrum. Results obtained in this study can be used to evaluate the long term reliability of the Runyang Suspension Bridge and provide reference values for wind resistant design of other structures in this region.

A Methodology of Radiation Measurement of MOSFET Dosimeter (MOSFET 검출기의 방사선 측정 기법)

  • Lho, Young-Hwan;Lee, Sang-Yong;Kang, Phil-Hyun
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.159-162
    • /
    • 2009
  • The necessity of radiation dosimeter with precise measurement of radiation dose is increased and required in the field of spacecraft, radiotheraphy hospital, atomic plant facility, etc. where radiation exists. Until now, a low power commercial metal-oxide semiconductor(MOS) transistor has been tested as a gamma radiation dosimeter. The measurement error between the actual value and the measurement one can occur since the MOSFET(MOS field-effect transistor) dosimeter, which is now being used, has two gates with same width. The measurement value of dosimeter depends on the variation of threshold voltage, which can be affected by the environment such as temperature. In this paper, a radiation dosimeter having a pair of MOSFET is designed in the same silicon substrate, in which each of the MOSFETs is operable in a bias mode and a test mode. It can measure the radiation dose by the difference between the threshold voltages regardless of the variation of temperature.

  • PDF

Development of a HTS SQUID gradiometer system for the measurement of very weak magnetic field in an unshielded environment (비자기차폐환경에서 미세 자기장 측정을 위한 고온초전도 gradiometer 시스템의 개발)

  • Kim, In-Seon;Kim, Jin-Mok;Park, Yong-Ki
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.151-154
    • /
    • 2000
  • We have developed a YBCO SQUID gradiometer system for the measurement of a very weak magnetic field in an unshielded environment. The system consists of a SQUID gradiometer sensor, low noise pre-amp, and FLL(fluxlocked loop) control electronics. The gradiometer sensors have been fabricated on STO bicrystal substrates, and exhibit a magnetic noise of 300 fT/${\surd}$ Hz/cm at 100 Hz. The overall magnetic field noise of the SQUID gradiometer system was about 10 pT/${\surd}$ Hz/cm at 10 Hz without any magnetic shield. The system demonstrated a high stability for a long time, and real-time measurement resolution ${\le}$ 100 pT/cm in the unshielded environments.

  • PDF

Measurement of Flow Field in the Pebble Bed Type High Temperature Gas-cooled Reactor (페블 베드 타입 고온 가스 냉각 원자로 내부 유동장 측정)

  • Lee, Sa-Ya;Lee, Jae-Young
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2088-2093
    • /
    • 2008
  • In this study, flow field measurement of the Pebble Bed Reactor(PBR) for the High Temperature Gas-cooled Reactor(HTGR) was performed. Large number of pebbles in the core of PBR provides complicated flow channel. Due to the complicated geometries, numerical analysis has been intensively made rather than experimental observation. However, the justification of computational simulation by the experimental study is crucial to develop solid analysis of design method. In the present study, a wind tunnel installed with pebbles stacked was constructed and equipped with the Particle Image Velocimetry(PIV). We designed the system scaled up to realize the room temperature condition according to the similarity. The PIV observation gave us stagnation points, low speed region so that the suspected high temperature region can be identified. With the further supplementary experimental works, the present system may produce valuable data to justify the Computational Fluid Dynamics(CFD) simulation method.

  • PDF

So, You Need Reliable Magnetic Measurements You Can Use With Confidence? How the Magnetic Measurement Capabilities at NPL Can Help

  • Hall, Michael;Harmon, Stuart;Thomas, Owen
    • Journal of Magnetics
    • /
    • v.18 no.3
    • /
    • pp.339-341
    • /
    • 2013
  • The magnetic field standards, facilities and capabilities available at NPL for the calibration of magnetometers and gradiometers and the measurement of the magnetic properties of materials will be introduced. The details of the low magnetic field facility will be explained and the capabilities this facility enables for the characterisation and calibration of ultra-sensitive room temperature magnetic sensors will be presented. Building on core material capabilities that are compliant with the IEC 60404 series of written standards, the example of a standard permeameter that has been modified for the measurement of strips for real world conditions is discussed. This was incorporated into a stress machine to measure the DC properties of the soft magnetic materials used by the partners of a collaborative industry led R&D project at stress levels of up to 700 MPa. The results for three materials are presented and the changes in the properties with applied stress compared to establish which material exhibits favourable properties.

Improvements of Reverberation Chamber's Performance by using Active Noise Control (능동 소음제어를 이용한 잔향실의 저주파 특성 개선 가능성)

  • K. Kim, Young-Key;Oh, Shi-Whan;Moon, Sang-Mu;Im, Jong-Min;Kim, Hong-Bae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.857-861
    • /
    • 2004
  • An active method that improves low frequency characteristics of a reverberation chamber has been proposed. Spatial uniformity of sound pressure at low frequency has been increased by applying active noise control system. The system acts as frequency selective damping materials, which decreases resonance at low frequency and leave high frequency sound field as it is. Linearity of the chamber, which is essential for sound power measurement in the chamber, is guaranteed since fixed control logic has been adopted. Simple application and tests have been done in a small sized rectangular reverberation chamber which has 400Hz cutoff, Loud speakers were used to simulate a noise source and to construct an active noise control system. The spatial distribution of a sound field at 250Hz, 315Hz and 400Hz bands has been measured before and after control. The standard deviation of sound field has been decreased from 3.4dB to 2.5dB. The results show the possibility of active control system as a sound diffuser.

  • PDF