• 제목/요약/키워드: low-cycle fatigue

검색결과 345건 처리시간 0.023초

Research of Diffusion Bonding of Tungsten/Copper and Their Properties under High Heat Flux

  • Li, Jun;Yang, Jianfeng
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.14-14
    • /
    • 2011
  • W (tungsten)-alloys will be the most promising plasma facing armor materials in highly loaded plasma interactive components of the next step fusion reactors due to its high melting point, high sputtering resistance and low deuterium/tritium retention. The bonding technology of tungsten to Cu alloy was one of the key issues. In this paper, W/CuCrZr diffusion bonding has been performed successfully by inserting pure metal interlay. The joint microstructure, interfacial elements migration and phase composition were analyzed by SEM, EDS, XRD, and the joint shear strength and micro-hardness were investigated. The mock-ups were fabricated successfully with diffusion bonding and the cladding technology respectively, and the high heat flux test and thermal fatigue test were carried out under actively cooling condition. When Ni foil was used for the bonding of tungsten to CuCrZr, two reaction layers, Ni4W and Ni(W) layer, appeared between the tungsten and Ni interlayer with the optimized condition. Even though Ni4W is hard and brittle, and the strength of the joint was oppositely increased (217 MPa) due primarily to extremely small thicknesses (2~3 ${\mu}m$). When Ti foil was selected as the interlayer, the Ti foil diffused quickly with Cu and was transformed into liquid phase at $1,000^{\circ}C$. Almost all of the liquid was extruded out of the interface zone under bonding pressure, and an extremely thin residual layer (1~2 ${\mu}m$) of the liquid phase was retained between the tungsten and CuCrZr, which shear strength exceeded 160 MPa. When Ni/Ti/Ni multiple interlayers were used for bonding of tungsten to CuCrZr, a large number of intermetallic compound ($Ni_4W/NiTi_2/NiTi/Ni_3T$) were formed for the interdiffusion among W, Ni and Ti. Therefore, the shear strength of the joint was low and just about 85 MPa. The residual stresses in the clad samples with flat, arc, rectangle and trapezoid interface were estimated by Finite Element Analysis. The simulation results show that the flat clad sample was subjected maximum residual stress at the edge of the interface, which could be cracked at the edge and propagated along the interface. As for the rectangle and trapezoid interface, the residual stresses of the interface were lower than that of the flat interface, and the interface of the arc clad sample have lowest residual stress and all of the residual stress with arc interface were divided into different grooved zones, so the probabilities of cracking and propagation were lower than other interfaces. The residual stresses of the mock-ups under high heat flux of 10 $MW/m^2$ were estimated by Finite Element Analysis. The tungsten of the flat interfaces was subjected to tensile stresses (positive $S_x$), and the CuCrZr was subjected to compressive stresses (negative $S_x$). If the interface have a little microcrack, the tungsten of joint was more liable to propagate than the CuCrZr due to the brittle of the tungsten. However, when the flat interface was substituted by arc interfaces, the periodical residual stresses in the joining region were either released or formed a stress field prohibiting the growth or nucleation of the interfacial cracks. Thermal fatigue tests were performed on the mock-ups of flat and arc interface under the heat flux of 10 $MW/m^2$ with the cooling water velocity of 10 m/s. After thermal cycle experiments, a large number of microcracks appeared at the tungsten substrate due to large radial tensile stress on the flat mock-up. The defects would largely affect the heat transfer capability and the structure reliability of the mock-up. As for the arc mock-up, even though some microcracks were found at the interface of the regions, all microcracks with arc interface were divided into different arc-grooved zones, so the propagation of microcracks is difficult.

  • PDF

박막증착시 티타늄 표면의 마손저항도와 세포독성에 관한 연구 (A STUDY ON THE RESISTANCE OF WEAR AND CYTOTOXICITY OF THE TITANIUM SURFACE AFTER FILM DEPOSITIONS)

  • 김형우;김창회;김영수
    • 대한치과보철학회지
    • /
    • 제39권1호
    • /
    • pp.84-95
    • /
    • 2001
  • Titanium is widely used in dentistry for its low density, high strength, fatigue resistance, corrosion resistance, and biocompatibility. But it has a tendency of surface damage under circumstance of friction and impact for its low hardness of the surface. Coating is one of methods fir increasing surface hardness. Its effect is to improve surface physical characteristics without change of titanium. Diamond-like carbon and titanium nitride are known for its high hardness of the surface. So that this study was aimed at the wear test and the cytotoxicity test of the commercially pure titanium and Ti-6Al-4V alloy which were deposited by diamond-like carbon film or titanium nitride film to acertain improvement of the surface hardness and the biocompatibility. A disk (25mm diameter, 2mm thickness) was made of commercially pure titanium and Ti-6Al-4V alloy and these substrates were deposited by diamond-like carbon film or titanium nitride film. Diamond-like carbon film was deposited by the method of radiofrequency plasma assisted chemical vapor deposition and titanium nitride film was deposited by the method of reactive arc ion plating. Then these substrates were tested about wear characteristics by the pin-on-disk type wear tester in which ruby ball was used as a wear causer under the load of 32N, The fracture cycles were measured by rotating the substrates until their films were fractured. The wear volume was measured after 150 cycles and 3,000 cycles using surface profiler. The cytotoxicity test was peformed by the method of the MTT assay. The results were as follows : 1. In the results of the wear volume test, commercially pure titanium and titanium alloy which were coated by diamond-like carbon film or titanium nitride aim had higher resistance against wear than the substrates which were not coated by any films (P<0.05). 2. In the results of the fracture cycle test and the wear volume test, diamond-like carbon film had higher resistance against wear than titanium nitride film (P<0.05). 3. In both coatings of diamond-like carbon aim and titanium nitride film, Ti-6Al-4V alloy had higher resistance against wear than commercially pure titanium (P<0.05) 4. In the results of the cytotoxicity test, diamond-like carbon film and titanium nitride film had little cytotoxicity as like commercially pure titanium or Ti-6Al-4V alloy (P>0.05).

  • PDF

Clinical Observation on Recombinant Human Endostatin Combined with Chemotherapy for Advanced Gastrointestinal Cancer

  • Gao, Shao-Rong;Li, Lu-Ming;Xia, Hai-Ping;Wang, Guang-Ming;Xu, Hong-Yan;Wang, Ai-Rong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권9호
    • /
    • pp.4037-4040
    • /
    • 2015
  • Objective: To explore the clinical efficacy and toxic and side effects of recombinant human endostatin (rhendostatin/endostar) combined with chemotherapy in the treatment of advanced gastric cancer. Materials and Methods: A total of 70 patients with advanced gastrointestinal adenocarcioma confirmed by histopathology and/or cytological examination were divided into group A (37 patients) and group B (33 patients). Patients in group A were given intravenous drip of 15 mg endostar added into 500 mL normal saline, once every other day until the cessation of chemotherapy or patients' maximal tolerance to chemotherapy. Patients in group B received chemotherapy alone. Two groups selected the same chemotherapy regimens. FOLFIRI scheme: 90-min intravenous drip of $180mg/m^2$ irinotecan, intravenous drip of $200mg/m^2$ calcium folinate (CF) and $400mg/m^2$ 5-fluorouracil (5-Fu) on d1, and continuous intravenous pumping of 2 $400mg/m^2$ 5-Fu for 46 h. FOLFOX4 scheme: intravenous injection of $85mg/m^2$ oxaliplatin (L-OHP), $200mg/m^2$ calcium folinate (CF) and $400mg/m^2$ 5-FU on d1 for 2 h, and then continuous intravenous pumping of 2 $400mg/m^2$ 5-Fu for 46 h. XELOX scheme: oral administration of 1 $500mg/m^2$ xeloda (or tegafur 50~60 mg) in twice during d1~14 and intravenous drip of $135mg/m^2$ L-OHP on d1 for 2 h. The modified FOLFOX scheme: intravenous injection of $135mg/m^2$ L-OHP on d1 for 2 h, $200mg/m^2$ CF and 1.0 g tegafur during d1~5. Whereas, control Group B received chemotherapy regimens which were same as Group A, but no addition of endostar. Before chemotherapy, patients were given intravenous injection of 8 mg ondansetron, intramuscular injection of 10 mg metoclopramide and 20 mg diphenhydramine for prevention of vomiting, protection of liver and stomach as well as symptomatic supportive treatment. One cycle was 21 d, 4~6 cycles in total. The efficacy was evaluated every 2 cycles. Results: 32 patients in Group A could be evaluated, and the response rate (RR) and disease control rate (DCR) were 59.38% and 78.13%, respectively. 31 patients in Groups could be evaluated, and the RR and DCR were 32.26% and 54.84%, respectively. The differences between 2 groups were significant. The toxic effects include myelosuppression, gastrointestinal reaction, fatigue, cardiotoxicity and peripheral neurotoxicity. Conclusions: Preliminary observations show that endostar (once every other day) combined with chemotherapy is effective in the treatment of advanced gastrointestinal cancer, with low toxic effects, good tolerance, deserving further study.

RBS 약축 용접모멘트접합부의 내진성능 평가 (Cyclic Seismic Performance of RBS Weak-Axis Welded Moment Connections)

  • 이철호;정종현;김성용
    • 한국강구조학회 논문집
    • /
    • 제27권6호
    • /
    • pp.513-523
    • /
    • 2015
  • H형강 철골 모멘트 골조에서는 기둥의 강축 방향 용접 모멘트접합부를 활용하는 것이 구조적으로 가장 이상적이다. 하지만, 모멘트 골조가 직교하는 경우, 기둥의 약축 방향으로도 용접 모멘트접합부를 사용해야 한다. 국내에서는 특히 강축 및 약축 방향 모두를 용접 모멘트접합부를 자주 사용하는 관행이 있다. 대표적인 연성내진상세인 RBS(reduced beam section, 보단면감소)접합부의 경우 국내외적으로 강축접합 위주로 실험연구가 진행되어 약축 RBS 용접모멘트접합부에 대한 실험자료가 매우 희소하다. 본 연구에서는 RBS를 도입한 약축 용접 모멘트접합부의 내진성능을 실험적으로 고찰하였다. Gilton-Uang (2002)의 선행연구를 참고하여 보 플랜지는 연속판과 맞댐용접하고 웨브는 전단이음판과 C-형 필릿용접부로 설계하여 실험을 수행하였다. 보에 사용된 강재가 내진용 강재가 아닌 일반 SS400 강재임에도 불구하고 3% 이상의 소성회전각을 발휘하였다. 제한된 결과이긴 하지만, 전단이음판과 보 웨브 사이의 C-형 필릿용접부 설계에서 보 웨브에 작용하는 휨모멘트와 전단력의 편심의 영향을 구체적으로 고찰할 필요가 있는 것으로 판단된다. 본 실험결과를 토대로 전단이음판 부근의 보 웨브 파단을 방지할 수 있는 C-형 필릿용접 형상 및 설계방안을 제안하였다. 보 플랜지와 연속판의 완전용입 용접부는 맞댄이음(butt joint) 형식이 되어 국부좌굴에 취약하고 이로 인해 피로파괴가 발생하는 경향이 있으므로 용접작업에 지장이 없는 범위에서 용접접근공(스켈럽)의 크기를 최소화할 필요가 있다. RBS형상, 스틱아웃, 트림, 연속판 두께 증가 등과 같이 이미 검증된 약축 모멘트 용접접합부의 내진상세들은 따르는 것이 바람직하다.

콘크리트채움 U형합성보-H형강기둥 십자형 합성접합부의 내진성능 (Cyclic Seismic Testing of Cruciform Concrete-Filled U-Shape Steel Beam-to-H Column Composite Connections)

  • 박창희;이철호;박홍근;황현종;이창남;김형섭;김성배
    • 한국강구조학회 논문집
    • /
    • 제23권4호
    • /
    • pp.503-514
    • /
    • 2011
  • 본 연구에서는 콘크리트채움 U형 합성보와 H형강 기둥 십자형 합성접합부의 내진상세를 제시하고, 2개의 실물대 실험체를 설계/제작하여 강구조내진기준의 표준실험절차에 따라 내진성능을 평가하였다. 주요 실험체 구성요소는 춤 450mm(실험체 A) 및 550mm(실험체 B) U형 강재보, 두께 165mm의 골데크플레이트 위에 타설된 콘크리트 바닥슬래브, U형보의 완전합성작용을 하기 위한 전단스터드, 부모멘트 전달을 위한 4개의 주철근 및 H형강 기둥에 정착을 위한 용접커플러 그리고 접합부 보강을 위한 보강판으로 구성된다. 순수 강재 보-기둥 접합부와 상이한 U형 합성접합부의 독특한 특성을 고려하여, 지진하중 하에서 내진성능에 결정적 영향을 미치는 보-기둥 접합부의 용접부 취성파단, 강판의 국부좌굴, 주철근의 휨좌굴, 콘크리트 압괴 등의 한계상태가 적절히 제어되도록 실험체를 설계하였다. 강구조내진기준의 지진하중 가력프로그램에 따른 실험결과, 설계에서 의도한 바와 같이 여러 한계상태가 적절히 제어되어 실험체 A 및 B는 각각 6% 및 6.8% 라디안에 이르는 매우 뛰어난 층간변형능력을 발휘하였다. 이는 특수모멘트골조에 요구되는 4% 라디안 수준을 충분히 상회하는 만족스런 층간변형능력이다. 특히 접합부 강화전략에 의해 제안된 합성접합부 상세는 설계에서 의도한 것과 같이 소성힌지를 보강단부로서 밀어냄으로서 취약할 수 있는 보-기둥 용접접합부를 효과적으로 보호하였다. 실험체 A의 최종 파괴모드는 6.0% 층간변위에서 발생한 보강단부에 인접한 냉간성형 코너부의 점진적 저사이클피로에 의한 하부플랜지의 파단에 의해 발생하였다. 한편, 실험체 B는 8.0%의 높은 수준의 층간변위에서 발생한 볼트이음부 파단에 의해 내력을 상실하였다.