• Title/Summary/Keyword: low vacuum condition

Search Result 193, Processing Time 0.027 seconds

Characteristic Study of Micro-Nozzles according to the Ratios of Nozzle Expansion and Specific heats in low vacuum condition (저진공상태에서 노즐 팽창비와 비열비에 따른 마이크로 노즐의 특성 연구)

  • Kim, Youn-Ho;Jung, Sung-Chul;Huh, Hwan-Il
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.249-252
    • /
    • 2006
  • We conducted the experiment to analyze characteristics of micro-nozzle using different cold gas under two different nozzle expansion ratios in low vacuum condition. We measured thrust and chamber pressure and mass flow rate under low vacuum condition, and then compared them with those in ambient pressure.

  • PDF

Friction and Wear at Dry Sliding Low Carbon Steel Surfaces Under Vacuum Conditions (진공분위기 내에서 건조마찰 미끄럼운동을 하는 저탄소강 표면의 마찰마모 특성)

  • 공호성;윤의성;권오관
    • Tribology and Lubricants
    • /
    • v.10 no.3
    • /
    • pp.29-38
    • /
    • 1994
  • The friction and wear of mild steel at dry sliding surfaces under different vacuum conditions have been investigated to understand the wear mechanisms. For the test, a ball-ondisk typed wear-rig has been built and implemented, allowing control of sliding speed, load and vacuum. Results show that, at a high sliding velocity, friction of low carbon steel (SS41) under a high vacuum is much higher than that of ambient condition and wear is much severer. It is due to lack of effective oxidation film formation on which steel surfaces could protect themselves against the severe wear. It has been shown, however, that there is a critical regime with contact conditions (at a low sliding velocity, a low load, and under a medium vacuum) at which effective, protective films of low carbon steel have been built on the surfaces in a friction process with a self-regulating way, resulting in both very low coefficients of friction (about 0.3) and mild wear. In order to investigate the protective films on steel surfaces, the worn surfaces and the wear debris have been experimentally analyzed with SEM, AES/SAM and XRD. A theoretical analysis of frictional heating at sliding surfaces, and an experimental analysis of the influence of oxidation wear under various vacuum conditions are described. The important variables on which self-formations of protective films at dry sliding surfaces depend, and the wear mechanisms are also investigated.

Inter-lamina Shear Strength of MWNT-reinforced Thin-Ply CFRP under LEO Space Environment

  • Moon, Jin Bum;Kim, Chun-Gon
    • Composites Research
    • /
    • v.30 no.1
    • /
    • pp.7-14
    • /
    • 2017
  • In this paper, the inter-lamina shear strength (ILSS) of multi-wall carbon nanotube (MWNT) reinforced carbon fiber reinforced plastics (CFRP) and thin-ply composites were verified under low earth orbit (LEO) space environment. CFRP, MWNT reinforced CFRP, thin-ply CFRP and MWNT reinforced thin-ply CFRP were tested after aging by using accelerated ground simulation equipment. The used ground simulation equipment can simulate high vacuum ($2.5{\times}10^{-6}torr$), atomic oxygen (AO, $9.15{\times}10^{14}atoms/cm^2{\cdot}s$), ultraviolet light (UV, 200 nm wave length) and thermal cycling ($-70{\sim}100^{\circ}C$) simultaneously. The duration of aging experiment was twenty hours, which is an equivalent duration to that of STS-4 space shuttle condition. After the aging experiment, ILSS were measured at room temperature ($27^{\circ}C$), high temperature ($100^{\circ}C$) and low temperature ($-100^{\circ}C$) to verify the effect of operation temperature. The MWNT and thin-ply shows good improvement of ILSS at ground condition especially with the thin-ply. And after LEO exposure large degradation of ILSS was observed at MWNT added composite due to the thermal cycle. And the degradation rate was much higher under the high temperature condition. But, at the low temperature condition, the ILSS was largely recovered due to the matrix toughening effect.

Design and Performance Test of Vacuum Control Valve for Electron Beam Lithography (전자빔 가공기의 진공제어 밸브설계 및 특성평가)

  • Lee Chan-Hong;Lee Hu-Sang
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.777-780
    • /
    • 2005
  • The high vacuum in a electron beam lithography is basic condition, because electron beam vanish by collision with air molecules in generally atmosphere. To make high vacuum state, the vacuum control valve is essential. Most vacuum control valve are manual units. So, user of manual vacuum valve must have understanding vacuum process to change from low vacuum to high vacuum state. The user of electron beam lithography are troubled with operation of manual vacuum valve, in case the vacuum chamber is frequently open. In this paper, the design and performance test of auto vacuum control valve for electron beam lithography are described. With the auto vacuum control valve, the high vacuum level can reach 2.8E-5 Torr.

  • PDF

A Development of the Precision Machine with Vacuum Chuck and a Study on the Characteristics of Oxygen Free Couper (진공척 미세 가공기 개발 및 무산소동 절삭 특성 연구)

  • Kim, Geon-Hee;Kim, Youn-Joong;Kook, Myung-Ho;Lee, Sun-Kyu;Hong, Kweon-Hee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.6 no.2
    • /
    • pp.28-33
    • /
    • 2007
  • This paper describes development of low cost precision machine that has a vacuum chuck. This study mainly aims to find out a cutting condition for maintaining optimum surface condition and to examine cutting characteristics of the precision machine that is equipped by diamond bites. The cutting materials is oxygen free copper. Several experiments were carried out to find out the main factors that affect the surface roughness such as principal axis RPM(rotation per minute), feeding speed, and cutting depth. As a result, we obtain The optimum cutting condition of the developed precision machine.

  • PDF

Uncooled Microbolometer FPA Sensor with Wafer-Level Vacuum Packaging (웨이퍼 레벨 진공 패키징 비냉각형 마이크로볼로미터 열화상 센서 개발)

  • Ahn, Misook;Han, Yong-Hee
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.300-305
    • /
    • 2018
  • The uncooled microbolometer thermal sensor for low cost and mass volume was designed to target the new infrared market that includes smart device, automotive, energy management, and so on. The microbolometer sensor features 80x60 pixels low-resolution format and enables the use of wafer-level vacuum packaging (WLVP) technology. Read-out IC (ROIC) implements infrared signal detection and offset correction for fixed pattern noise (FPN) using an internal digital to analog convertor (DAC) value control function. A reliable WLVP thermal sensor was obtained with the design of lid wafer, the formation of Au80%wtSn20% eutectic solder, outgassing control and wafer to wafer bonding condition. The measurement of thermal conductance enables us to inspect the internal atmosphere condition of WLVP microbolometer sensor. The difference between the measurement value and design one is $3.6{\times}10-9$ [W/K] which indicates that thermal loss is mainly on account of floating legs. The mean time to failure (MTTF) of a WLVP thermal sensor is estimated to be about 10.2 years with a confidence level of 95 %. Reliability tests such as high temperature/low temperature, bump, vibration, etc. were also conducted. Devices were found to work properly after accelerated stress tests. A thermal camera with visible camera was developed. The thermal camera is available for non-contact temperature measurement providing an image that merged the thermal image and the visible image.

대형 열진공챔버용 극저온 모사장치 개발

  • Lee, Sang-Hoon;Cho, Hyok-Jin;Seo, Hee-Jun;Moon, Guee-Won;Choi, Seok-Weon
    • Aerospace Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.103-108
    • /
    • 2004
  • The space environment is characterized such a severe condition as high vacuum and very low temperature. Since a satellite will be exposed such a space environment as soon as it goes into the its orbit, thermal vacuum test should be carried out to verify the performance of the satellite on the ground under the space environmental conditions. KARI has a thermal vacuum chamber with useful dimensions of ∮3.6m×L3m, in which KOMPSAT-1 and KOMPSAT-2 satellites were tested. But very large thermal vacuum chamber with useful dimensions of ∮8m×L10m has been needed to meet the future demand of large satellites. Generally, the thermal vacuum chamber can be divided into a vacuum system and a thermal system. Especially, a cryogenic system in the thermal system simulates very low temperature of -196℃ under the high vacuum condition. In this paper, we propose the new cryogenic system can be applied to the future large thermal vacuum chamber.

  • PDF

A Study on the Thermal Characteristics of the Large Low Temperature Vacuum Dryer for Biological Drying (생체 건조용 대형 저온진공건조기의 열적 특성에 관한 연구)

  • 김경근;성부용;정한식;최순열;문수범
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.4
    • /
    • pp.427-434
    • /
    • 2000
  • In tradition, there have been two kinds of drying methods, which are sun drying and artificial drying. The sun drying method which has been adopted traditionally has been replaced by the hot-air drying method which is one of the most general methods of artificial drying, with its simple drying system, low initial cost of drying plant, and easy operating method. But the hot-air drying method has some defects; (1) much energy loss happens due to the discharge of hot air during the drying process, (2) control of drying rate is not easy on account of changing relative humidity of inlet air for uniform hot air temperature, (3) high temperature of foods in drying process brings about the production of low-grade drying products. Vacuum drying takes advantage of energy saving and mass production because it reduces the drying time by increasing the drying rate under low temperature condition. The aim of this paper is to develop the low temperature vacum dryer, with low initial investments and operating costs, easy operating method and trouble-free operation.

  • PDF

Establishment of Shelf-life of Vacuum Packaged Pork Loins for exporting to Japan (대일 수출용 진공포장 냉장등심의 유통기한 설정)

  • 이무하
    • Food Science of Animal Resources
    • /
    • v.18 no.2
    • /
    • pp.115-124
    • /
    • 1998
  • This study was carried out investigate hygienic conditions of domestic packing plant for export and the shelf-life by Japanese standards. vacuum packaged chilled port loins provided by five packers(A, B, C, D and E) were transported to Japan in the same condition, Four packers(A, B, C adn d) produced the samples as hygienic as possible and one packer produced loins in the traditional hygienic condition, In TTC(2,3,5-triphenyl tetrazolium chloride) test all samples showed the negative reaction from the date of the quarantine(14 days after slaughtering) to 50 days The numbers of total plate count(TPC) of A, B, C and D packers that were below 108CFU/g until 50 days were accepted by Japanese Standards but TPC of E packer was over 107CFU/g at 30 days. VBN values increased sig-nificantly(P<0.01) in samples of A,B and D packers in the samples of C packer and E packer at 5% and 0.1% level respectively. The pH values of the vacuum packaged chilled pork for export at 14 days after slaughtering were 5.43∼6.00 In sensory evaluation, A, B, C and D packers which improved hygi-enic condition produced the products with good color and appearance. low drip until 40 days storage at $0^{\circ}C$ But as the storage time increase off-flavor occured at 40days in A and D packer and at 50days in B and C packer. In conclusion according to the above results of microbiological physicochemical and sensory evalution the edible periods of Korean vacuum package chilled porks may be estimated to 40∼50 days for the packers who improved hygienic condition and the shelf lives were calculated as 32∼40 days from edible period by a factor of 0.8(safety coefficient) while that of the pork from E packer which was produced in the traditional hygienic condition was estimated to 30 days after slaughtering at $0^{\circ}C$ Therefore the shelf-life of the pork of E packer would be only 24 days.

  • PDF

Servo Track Writing for Ultra-High TPI Disk Drive in Low Density Medium Condition (초고밀도 디스크 드라이브를 위한 저밀도 작동 환경에서 서보 트랙 기록 방법에 대한 연구)

  • 한윤식;김철순;강성우
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.736-741
    • /
    • 2004
  • In high-capacity disk drives with ever-growing track density, the allowable level of position error signal (PES) is becoming smaller and smaller. In order to achieve the high TPI disk drive, it is necessary to improve the writing accuracy during the STW(servo track writing) process through the reduction of TMR sources. Among the main contributors of the NRRO(Non-Repeatable Run-out) PES, the disk vibration and the HSA(head-stack assembly) vibration is considered to be one of the most significant factors. Also the most contributors of RRO(Repeatable Run- out) come from the contributors of NRRO which is written-in at the time of STW(servo track writing) process. In this paper, the experimental test result shows that the effect of NRRO on servo written-in RRO effectively can be reduced through a STW process under low dense medium condition such as semi-vacuum.

  • PDF