• Title/Summary/Keyword: low profile

Search Result 1,612, Processing Time 0.026 seconds

The Clinical Results of the Proximal Opening Wedge Osteotomy Using a Low Profile Plate in Hallux Valgus: Comparison with Proximal Chevron Osteotomy Fixed with K-wires (무지외반증에서 저상형 금속판 고정을 이용한 근위 개방형 절골술의 임상적 결과: 근위 갈매기형 절골술 후 K-강선 고정술과의 비교)

  • Seo, Eun-Seok;Bang, Tae-Jung;Jeon, Suk-Ha
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.4
    • /
    • pp.302-308
    • /
    • 2013
  • Purpose: To present clinical results of proximal first metatarsal opening wedge osteotomy and low profile plate fixation in hallux valgus deformity. Materials and Methods: Thirty-two patients (39 feet) underwent surgery for hallux valgus deformity. Fourteen patients (18 feet; Group A) underwent proximal first metatarsal opening wedge osteotomy fixed with low profile titanium plate ($Arthrex^{(R)}$), and 18 patients (21 feet; Group B) underwent proximal chevron osteotomy with two K-wires. Improvement in hallux valgus angle (HVA), 1, 2 intermetatarsal angle (IMA), range of motion of 1st metatarsophalangeal joint, VAS score, and the length of first metatarsal on weight-bearing radiograph were evaluated preoperatively and at final follow-up. Results: HVA improved from $36.2{\pm}6.6$ degrees to $11.7{\pm}5.1$ degrees, and 1, 2 IMA improved from $15.7{\pm}2.6$ degrees to $7.2{\pm}1.9$ degrees. VAS score improved from $7.2{\pm}1.2$ to $1.4{\pm}0.9$. There were no significant differences clinically and radiologically. Conclusion: Proximal first metatarsal opening wedge osteotomy with stable fixation using low profile plate may be an effective surgical option for correction of hallux valgus deformity.

A Study on AESA Antenna Performance Advancement for Seeker (탐색기용 AESA 안테나 성능 고도화 연구)

  • Youngwan Kim;Jong-Kyun Back;Hee-Duck Chae;Ji-Han Joo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.5
    • /
    • pp.103-108
    • /
    • 2023
  • In this paper, a performance enhancement study of an AESA antenna that can be applied to a seeker that serves as the eye of a missile was conducted, and the performance of the antenna was verified through actual measurement. When designing an AESA antenna, the optimization of the active reflection coefficient must be considered during transmission due to the mutual coupling between radiators that inevitably occurs, and the selection of a radiator that can overcome the space limitation of the seeker with a small size/light weight is an important design consideration. Accordingly, optimization in terms of electrical performance and low-profile structure is required through research on array antennas for application to the AESA structure. The radiator designed and measured in this paper was designed as an SFN that can satisfy the low-profile structure while enhancing the performance of a general vivaldi antenna. Through this paper, it was confirmed that SFN has the same broadband characteristics as general vivaldi antennas and has optimized characteristics required for AESA antennas. The structure optimized through simulation confirmed the pattern characteristics and active reflection coefficient characteristics through the fabrication of actual proto-type antennas.

Emotional Intelligence Profile and Employee Attitude

  • Seoyeon LEE;Jaeseung MOON
    • East Asian Journal of Business Economics (EAJBE)
    • /
    • v.11 no.2
    • /
    • pp.1-13
    • /
    • 2023
  • Purpose - The purpose of this study is to identify emotional intelligence (EI) profiles according to the sub-factors of the ability EI model, namely, self-emotional appraisal, others' emotional appraisal, regulation of emotion, and use of emotion. In addition, this study aims to reveal whether there is a difference in job satisfaction, affective commitment, and turnover intention depending on the profile. Research design, data, and methodology - For the study, 536 survey responses were analyzed using SPSS 22 and MPlus 8.4. Result - The analysis identified four EI profiles. These were 1) middle-low generalized EI (all sub-factors of EI were slightly lower than the average level), 2) middle-high generalized EI (all sub-factors of EI were slightly higher than the average), 3) low generalized EI (all EI sub-factors were much lower than the average), and 4) high generalized EI (all EI sub-factors were much higher than average). Furthermore, significant differences were found in job satisfaction, affective commitment, and turnover intention according to each profile. Conclusion - This study expands the EI theory by revealing the profile of EI. In addition, this study investigated the impact of EI profile on job satisfaction, affective commitment, and turnover intention.

Preparation and Characteristic of Sheet Molding Compound using Unsaturated Polyester Resin with Low Profile Agent of Polystyrene (저수축제 폴리스틸렌과 불포화 폴리에스터 수지를 사용한 Sheet Molding Compound 제조 및 특성)

  • Bae, Gi Boong;Lee, Sang Goo;Yoon, Hong Jin;Lee, Jong Dae
    • Korean Chemical Engineering Research
    • /
    • v.50 no.3
    • /
    • pp.588-593
    • /
    • 2012
  • Compatibility of unsaturated polyester (UP) and low profile agent (LPA) of polystyrene (PS) have been investigated under various mixing conditions such as the ratio of UP and LPA, mixing time, mixing temperature, and input amount of 2nd UP. It was possible to obtain mixture with small particle size and low phase separation in condition of 35 g of LPA, 25 g of 1st UP input, 5 min of mixing time, 1700 rpm of mixing speed, and 45 g of 2nd UP input. It was found that compatibility of UP and LPA was very sensitive to mixing conditions. In addition, molded sample using sheet molding compound prepared by stable mixing condition appeared good properties such as low water adsorption, low shrinkage, and high gloss.

Design and analysis of low velocity impact on thermoplastic hat section with curvilinear profile

  • Gaur, Kumresh K;Dwivedi, Mayank;Bhatnagar, Naresh
    • Advances in materials Research
    • /
    • v.6 no.1
    • /
    • pp.65-78
    • /
    • 2017
  • A hat section was designed and developed for maximum impact energy absorption and/or transmission under low velocity impact. Towards this, different hat sections, having material properties of thermoplastic, were modeled and investigated numerically using finite element analysis (FEA) in the range of 20-50 J impact energy. In the study it was experienced that the design configuration of hat section with curvilinear profile (HSCP) was excellent in energy attenuation capacity and for even distribution of maximum impact force around and along the hat section under low velocity impact loading. To validate the numerical findings, polypropylene copolymer (Co-PP) HSCP and low density polyethylene (LDPE) HSCP were developed and evaluated experimentally in the said impact energy range. A correlation was established between FEA and experimental test results, thereby, validating a numerical model to predict results for other thermoplastic materials under given range of impact energy. The LDPE HSCP exhibited better performance as compared to Co-PP HSCP in the said range of impact energy. The findings of this study will enable the engineers and technologists to design and develop low velocity impact resistance devices for various applications including devices to protect bone joints.

Contact Stress of Slewing Ring Bearing with External Pinwheel Gear Set (핀 휠을 구비한 외륜형 선회베어링의 면압강도)

  • Kwon, Soon-man
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.2
    • /
    • pp.231-237
    • /
    • 2015
  • The pin-gear drive is a special form of fixed-axle gear mechanism. A large wheel with cylindrical pin teeth is called a pinwheel. As pinwheels are rounded, they have a simple structure, easy processing, low cost, and easy overhaul compared with general gears. They are also suitable for low-speed, heavy-duty mechanical transmission and for occasions with more dust, poor lubrication, etc. This paper introduces a novel slewing ring bearing with an external pinwheel gear set (e-PGS). First, we consider the exact cam pinion profile of the e-PGS with the introduction of a profile shift. Then, the contact stresses are investigated to determine the characteristics of the surface fatigue by varying the shape design parameters. The results show that the contact stresses of the e-PGS can be lowered significantly by increasing the profile shift coefficient.

Development of rotor profile design technology for improving the screw compressor performance (공기압축기 성능향상을 위한 로터 프로파일 설계기술 개발 연구)

  • Kim, Tae-Yoon;Lee, Jae-Young;Lee, Dong-Kyun;Kim, Youn-Jea
    • Proceedings of the KSR Conference
    • /
    • 2009.05b
    • /
    • pp.585-592
    • /
    • 2009
  • The performance of screw compressor depends on lots of design parameters of rotor profile, such as length of seal line, wrap angle, blow hole, suction and discharge port size, number of rotor lobe, etc. The optimum rotor profile makes it possible to increase the compression efficiency with low energy consumption, and to minimize the loss of power. In this research, a new rotor profile design and performance analysis are done by computer simulation. It is expected that the volumetric efficiency is improved because the internal leakage is reduced due to the minimization of blow hole and clearance, and the stiffness of rotors is increased due to the reduction of length to diameter ratio. Also, the specific power consumption will be secured for use ranging from low to high operation speed.

  • PDF

A Low-Profile DC-To-DC Converter for Sustain Driving Circuits of AC PDP Application Systems (저소비전력 PDP 구동을 위한 고효율 박형 전원회로 개발)

  • Lee S.W.;Choi B.C;Lee K.J.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.247-250
    • /
    • 2003
  • The current paper presents the design and implementation of a low-profile dc-to-dc converter developed as a power supply for the sustain driving: circuit inside large-area wall-mount ac PDP application systems. Details on the design and implementation of a 500 W prototype dc-to-dc converter, miniaturized within a 230 mm$\times$ 130 mm area with a thickness of 25 mm while still achieving a 95 $\%$ conversion efficiency, are presented to demonstrate the feasibility and application potentials of the proposed low-profile dc -to-dc converters.

  • PDF

Low-Profile Planar Inverted-F Antenna for Ultrawideband Applications

  • Yun, Junsik;Choi, Jaehoon
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.4
    • /
    • pp.235-240
    • /
    • 2016
  • In this paper, a low-profile planar inverted-F antenna (PIFA) for ultrawideband (UWB) applications is proposed. The antenna consists of a PIFA and a ground plane with a slot. The addition of the slot not only improves the impedance matching of the PIFA but also forms an additional resonance. Therefore, the proposed antenna has a wideband characteristic covering the full UWB frequency range (3.1 GHz to 10.6 GHz) and a stable and nearly omnidirectional radiation pattern. The antenna also has a smaller volume and thickness compared to previous UWB PIFAs.

Durability of the Low Profile Ionescu-Shiley Valve in Aortic Position (이오네스큐 단고형 대동맥판의 내구성)

  • 김종환
    • Journal of Chest Surgery
    • /
    • v.25 no.10
    • /
    • pp.1041-1047
    • /
    • 1992
  • The consecutive 35 patients underwent isolated aortic valve replacement with the low-profile model of the Ionescu-Shiley pericardial xenograft valve from 1984 to 1991. Operative mortality was 2.9%, and early survivors were followed up for a total 136.1 patient-years[Mean$\pm$SD, 4.00$\pm$2.14 years]. The linearized late mortality was 2.204% /pt-yr. Three patients required rereplacement of the valve with overall valve failure rate of 2.204% /pt-yr: two for endocarditis and one for paravalvular leak. There was no case of primary tissue failure. The linearized annual rates of complication were: thromboembolism 0.735% /pt-yr, bleeding 0.735%pt-yr, and endocarditis 2.204% /pt-yr. The actuarial survival at 8 years of follow-up was 90.4$\pm$5.3%, and the probabilities of freedom from thromboembolism and from rereplacement were 95.6$\pm$4.4% and 88.2$\pm$6.7% at 8 years respectively. Although the low profile Ionescu-Shiley pericardial valve provided favorable clinical performance comparable with the standard model up to 8 years, it needs prolonged follow-up to assess the pattern of its durability.

  • PDF