• 제목/요약/키워드: low power mode

검색결과 1,109건 처리시간 0.031초

저감된 DC Link Capacitor 부피를 가지는 역률 개선 Valley-Fill Flyback 컨버터의 설계 및 구현 (Practical Design and Implementation of a Power Factor Correction Valley-Fill Flyback Converter with Reduced DC Link Capacitor Volume)

  • 김세민;강경수;공성재;유혜미;노정욱
    • 전력전자학회논문지
    • /
    • 제22권4호
    • /
    • pp.277-284
    • /
    • 2017
  • For passive power factor correction, the valley fill circuit approach is attractive for low power applications because of low cost, high efficiency, and simple circuit design. However, to vouch for the product quality, two dc-link capacitors in the valley fill circuit should be selected to withstand the peak rectified ac input voltage. The common mode (CM) and differential mode (DM) choke should be used to suppress the electromagnetic interference (EMI) noise, thereby resulting in large size volume product. This paper presents the practical design and implementation of a valley fill flyback converter with reduced dc link capacitors and EMI magnetic volumes. By using the proposed over voltage protection circuit, dc-link capacitors in the valley fill circuit can be selected to withstand half the peak rectified ac input voltage, and the proposed CM/DM choke can be successfully adopted. The proposed circuit effectiveness is shown by simulation and experimentally verified by a 78W prototype.

저전력을 위한 버퍼 캐쉬 관리 기법 (Buffer Cache Management for Low Power Consumption)

  • 이민;서의성;이준원
    • 한국정보과학회논문지:시스템및이론
    • /
    • 제35권6호
    • /
    • pp.293-303
    • /
    • 2008
  • 컴퓨팅 환경이 무선과 휴대용 시스템으로 변화하면서, 전력효율이 점점 중요해지고 있다. 특히 내장형 시스템일 경우에 더욱 그러한데 이중 메모리에서 소모되는 전력이 전체 전력소모의 두 번째 큰 요소가 되고 있다. 메모리 시스템에서의 전력소모를 줄이기 위해서 SDRAM의 저전력 모드를 활용할 수 있다. RDRAM의 경우 냅모드(nap mode)는 액티브 모드(active mode)의 5%이하의 전력만을 소모한다. 하지만 하드웨어 컨트롤러는 운영체제가 협조하지 않으면 이 기능을 효율적으로 활용하지 못한다. 이 논문에서는 SDRAM의 액티브 유닛(active unit)의 수를 최소화하는 방법에 초점을 맞춘다. 운영체제는 참조되지 않는 메모리를 저전력 모드에 놓음으로써 최소한의 유닛들만을 액티브 모드에 놓은 상태로 프로그램이 수행될 수 있도록 피지컬(physical) 페이지들을 할당한다. 이것은 PAVM(Power Aware Virtual Memory) 연구의 일반화된 시스템 전반에 대한 연구라고 할 수 있다. 우리는 모든 피지컬 메모리를 고려하고 있으며, 특히 평균적으로 전체 메모리의 절반을 사용하는 버퍼 캐시를 고려하고 있다. 버퍼 캐시의 용량과 그 중요성 때문에 PAVM 방식은 버퍼 캐시를 고려하지 않고는 완전한 해법이 되지 못한다. 이 논문에서 우리는 메모리의 사용처를 분석하고 저전력 페이지 할당 정책을 제안한다. 특히 프로세스의 주소공간에 매핑(mapping)된 페이지들과 버퍼 캐시가 고려된다. 이 두 종류의 페이지들간의 상호작용과 그 관계를 분석하고 저전력을 위해 이러한 관계를 이용한다.

Single Sensor Charging System with MPPT Capability for Standalone Streetlight Applications

  • Osman, Siti Rahimah;Rahim, Nasrudin Abd.;Selvaraj, Jeyraj;Al-Turki, Yusuf A.
    • Journal of Power Electronics
    • /
    • 제15권4호
    • /
    • pp.929-938
    • /
    • 2015
  • Maximum power point tracking (MPPT) and battery charging control are two important functions for a solar battery charger. The former improves utilization of the available solar energy, while the latter ensures a prolonged battery life. Nevertheless, complete implementation of both functions can be complex and costly, especially for low voltage application such as standalone street lamps. In this paper, the operation of a solar battery charger for standalone street light systems is investigated. Using only one voltage sensor, the solar charger is able to operate in both MPPT and constant voltage (CV) charging mode, hence providing high performance at a low cost. Using a lab prototype and a solar simulator, the operation of the charger system is demonstrated and its performance under varying irradiance is validated.

발전용 희박예혼합 가스터빈에서 연소모드변환 시기의 연소특성 해석 (Numerical Analysis of Combustion Characteristics during Mode Transfer Period in a Lean Premixed Gas Turbine for Power Generation)

  • 정재화;서석빈;김종진;차동진;안달홍
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.279-282
    • /
    • 2002
  • Recently, gas turbines for power generation adopt multistage DLN(Dry Low NOx) type combustion, where diffusion combustion is applied at low load and, with increase in load, the combustion mode is changed to lean premixed combustion to reduce NOx emissive concentration. However, during the mode changeover from diffusion to premixed flame, unfavorable phenomena, such as flashback, high amplitude combustion oscillations, or thermal damage of combustor parts could frequently occur. In the present study, to apply for the analysis of such unfavorable phenomena, three-dimensional CFD investigations are carried out to compare the detailed flow characteristics and temperature distribution inside the gas turbine combustor before and after combustion mode changeover. The fuel considered here is pure methane gas. A standard $k-{\varepsilon}$ turbulence model with wall function and a P-N type radiation heat transfer model, have been utilized. To analyze the complex geometric effects of combustor parts on combustion characteristics, fuel nozzles, a swirl vane f3r fuel-air mixing, and cooling air holes on the combustor liner wall, are included in this simulation.

  • PDF

Transformer-Reuse Reconfigurable Synchronous Boost Converter with 20 mV MPPT-Input, 88% Efficiency, and 37 mW Maximum Output Power

  • Im, Jong-Pil;Moon, Seung-Eon;Lyuh, Chun-Gi
    • ETRI Journal
    • /
    • 제38권4호
    • /
    • pp.654-664
    • /
    • 2016
  • This paper presents a transformer-based reconfigurable synchronous boost converter. The lowest maximum power point tracking (MPPT)-input voltage and peak efficiency of the proposed boost converter, 20 mV and 88%, respectively, were achieved using a reconfigurable synchronous structure, static power loss minimization design, and efficiency boost mode change (EBMC) method. The proposed reconfigurable synchronous structure for high efficiency enables both a transformer-based self-startup mode (TSM) and an inductor-based MPPT mode (IMM) with a power PMOS switch instead of a diode. In addition, a static power loss minimization design, which was developed to reduce the leakage current of the native switch and quiescent current of the control blocks, enables a low input operation voltage. Furthermore, the proposed EBMC method is able to change the TSM into IMM with no additional time or energy loss. A prototype chip was implemented using a $0.18-{\mu}m$ CMOS process, and operates within an input voltage range of 9 mV to 1 V, and an output voltage range of 1 V to 3.3 V, and provides a maximum output power of 37 mW.

스위치모드 컨버터에 의한 새로운 슬립전력 회수시스템 (A New Slip Power Recovery System by Switch Mode Converter)

  • 박한웅;박성준;김철우;황영문
    • 전력전자학회논문지
    • /
    • 제4권1호
    • /
    • pp.73-81
    • /
    • 1999
  • 본 연구에서는 권선형 유도전동기의 회전자회로에 스위치모드 컨버터를 적용시킨 새로운 슬립전력 회수시스템을 제안하고 이를 분석한다. 제안된 시스템의 해석을 통해 적용된 컨버터의 듀티비에 의해 속도가 제어될 수 있으며, 동시에 기존 시스템의 몇가지 특성을 개선할 수 있음을 보인다. 특히 종래 시스템에서 주된 단점으로 되어 있는 저역률 및 전원전류의 고조파성분을 크게 개선할 수 있을 뿐만 아니라 선형적인 속도조절도 가능하다. 제안된 시스템의 타당성을 보이기 위해 이론 및 실험 결과를 제시하고 이를 설명한다.

Robust Sensorless Sliding Mode Flux Observer for DTC-SVM-based Drive with Inverter Nonlinearity Compensation

  • Aimad, Ahriche;Madjid, Kidouche;Mekhilef, Saad
    • Journal of Power Electronics
    • /
    • 제14권1호
    • /
    • pp.125-134
    • /
    • 2014
  • This paper presents a robust and speed-sensorless stator flux estimation for induction motor direct torque control. The proposed observer is based on sliding mode approach. Stator electrical equations are used in the rotor orientation reference frame to eliminate the observer dependence on rotor speed. Lyapunov's concept for systems stability is adopted to confine the observer gain. Furthermore, the sensitivity of the observer to parameter mismatch is recovered with an adaptation technique. The nonlinearities of the pulse width modulation voltage source inverter are estimated and compensated to enhance stability at low speeds. Therefore, a new method based on the model reference adaptive system is proposed. Simulation and experimental results are shown to verify the feasibility and effectiveness of the proposed algorithms.

슬라이딩모드 제어기를 이용한 공기압 실린더 구동장치의 강인제어 (Robust Control of Pneumatic Cylinder Driving System using Sliding Mode Controller)

  • 장지성;한승훈
    • 동력기계공학회지
    • /
    • 제21권6호
    • /
    • pp.101-109
    • /
    • 2017
  • The pneumatic driving system has advantages such as high output power per weight and low heat generation rate. However, it is difficult to control the position because of its strong non-linearity such as large friction forces compared to driving force, and heat transfer characteristics that change during operation. Therefore, in order to achieve the control objectives, a robust controller should be designed considering modeling error and model uncertainty. In this paper, a sliding mode controller is designed to improve the position control performance of pneumatic cylinder driving system. Experimental results show that the designed controller achieves the designed control objectives even if the model of the cylinder driving system, such as the initial pressure inside the cylinder and the initial position of the piston is changed.

영구자석 동기발전기 시스템을 위한 회전자 관성에너지를 이용한 Sliding Mode제어 기반 LVRT 제어 (Use of Stored Energy in Rotor Inertia for LVRT of PMSG Wind turbine based on Sliding Mode Control)

  • 정대헌;계용호;김청훈;정정주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1058-1059
    • /
    • 2015
  • This paper describes a low-voltage ride-through method for the permanent magnet synchronous generator (PMSG) wind turbine system at a grid fault. The generator side converter regulates the DC link voltage instead of the grid side converter by storing the surplus active power in the rotor inertia during grid fault by the sliding mode controller. The grid side converter controls the grid active power keeping a maximum power point tracking. Simulation results for small scale PMSG wind turbine verify the efficiency of the control method.

  • PDF

Thickness-Vibration-Mode Piezoelectric Transformer for Power Converter

  • Su-Ho lee;Yoo, Ju-Hyun;Yoon, H.S.
    • Transactions on Electrical and Electronic Materials
    • /
    • 제1권3호
    • /
    • pp.1-5
    • /
    • 2000
  • This paper presents a new sort of multilayer piezoelectric ceramic transformer for switching regulation power supplies. This piezoelectric transformer operate in the second thickness resonant vibration mode. Accordingly its resonant frequency is higher than 1 NHz, Because output power is low if input and output part of transformer are consisted of single layer, this research suggests a new method, which is consisted of both input and output part of transformer have 2-layered piezoelectric ceramics, The size of transformer is 20 mm in width and length, and 1.4 mm in thickness, respectively, To design a high efficient switching circuit of the transformer, internal circuit parameters were measured and then weve calculated a parameter of inductor nd capacitor to design a driving circuit, Weve used a MISFET and its driver circuit modified a calp oscillator circuit as the primary switching circuit.

  • PDF