• 제목/요약/키워드: low leakage

검색결과 1,336건 처리시간 0.032초

Diffusion Range and Pool Formation in the Leakage of Liquid Hydrogen Storage Tank Using CFD Tools

  • Kim, Soohyeon;Lee, Minkyung;Kim, Junghwan;Lee, Jaehun
    • 공업화학
    • /
    • 제33권6호
    • /
    • pp.653-660
    • /
    • 2022
  • In liquid hydrogen storage tanks, tank damage or leakage in the surrounding pipes possess a major risk. Since these tanks store huge amounts of the fluid among all the liquid hydrogen process facilities, there is a high risk of leakage-related accidents. Therefore, in this study, we conducted a risk assessment of liquid hydrogen leakage for a grid-type liquid hydrogen storage tank (lattice-type pressure vessel (LPV): 18 m3) that overcame the low space efficiency of the existing pressure vessel shape. Through a commercially developed three-dimensional computational fluid dynamics program, the geometry of the site, where the liquid hydrogen storage tank will be installed, was obtained and simulations of the leakage scenarios for each situation were performed. From the computational flow analysis results, the pool formation behavior in the event of liquid hydrogen leakage was identified, and the resulting damage range was predicted.

공기조화기용 스크롤 압축기의 플랭크 및 팁실 누설특성 (Characteristics of Flank and Tip Seal Leakage in a Scroll Compressor for Air-Conditioners)

  • 윤영;김용찬;민만기
    • 설비공학논문집
    • /
    • 제13권2호
    • /
    • pp.134-143
    • /
    • 2001
  • This paper presents the characteristics of flank and tip seal leakage in a scroll compressor for air-conditioners with R-22 under actual operating conditions. It is well known that the leakage has significant effect on the performance of the scroll compressor. Experiments were performed by using indirect method for measuring mass flow rate passing through flank and tip seal under actual operating conditions, In addition, an analytical model for tip seal leakage was developed to investigate tangential and radial leakage observed at grooves and contact points of tip seals. For low oil concentration, theoretical results were compared with experimental data to verify the analytical model. As a result, leakages through flank and tip seal parts were evaluated as afunction of pressure ratio, orbiting angle, discharge pressure, tip clearance, and leakage point. It was also found that the tip seal leakage was considerable even though the tip seal provided adequate sealing effect.

  • PDF

수소혼입 천연가스 배관망의 누출 특성 분석 및 누출 시나리오 선정에 관한 연구 (A Study on the Analysis of the Leakage Characteristics and the Selection of Leakage Scenarios of the Blending Hydrogen into Natural Gas Pipeline)

  • 탁송수;임기섭
    • 한국안전학회지
    • /
    • 제39권1호
    • /
    • pp.27-32
    • /
    • 2024
  • This study analyzed cases of hydrogen (H2) and natural gas (CH4) leakage from a hydrogen-blended natural gas pipeline to determine a range of leakage characteristics, including leakage type, pipe material, pipe diameter, pressure, and damage size. Based on the results of this analysis, five hydrogen-blended natural gas leakage scenarios were selected. The national vision for a carbon-neutral society by 2050 is a very important strategic objective and promotes environmentally sustainable economic development in the age of the climate crisis. Accordingly, zero-carbon and low-carbon policies are being promoted in various fields, including energy production, consumption, and industrial processes. Hydrogen-blended natural gas is eco-friendly and is considered an important step towards carbon neutrality, with various countries including the United States and several European countries conducting empirical research to further investigate its potential. In Korea, a national research project commenced in April 2023 to verify and demonstrate the life cycle safety of blending hydrogen into the natural gas network. The results of this study will provide important data for the analysis of the damage impacts caused by the leakage of hydrogen-blended natural gas, such as the diffusion of gas clouds, fires, and gas explosions.

V-Based Self-Forming Layers as Cu Diffusion Barrier on Low-k Samples

  • 박재형;문대용;한동석;강유진;신소라;박종완
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.409-409
    • /
    • 2013
  • 최근, 집적 소자의 미세화에 따라 늘어난 배선 신호 지연 및 상호 간섭, 그리고 소비 전력의 증가는 초고집적 소자 성능 개선에 한계를 가져온다. 이에 따라 기존의 알루미늄(Al)/실리콘 절연 산화막은 구리(Cu)/저유전율 박막(low-k)으로 대체되고 있고, 이는 소자 성능 개선에 큰 영향을 미친다. 그러나 Cu는 Si과 low-k 내부로 확산이 빠르게 일어나 소자의 비저항을 높이고, 누설 전류를 일으키는 등 소자의 성능을 저하시킬 수 있는 문제점을 가지고 있다. 이러한 Cu의 확산을 막기 위하여 Ta, TaN 등과 같은 확산방지막에 대한 연구가 활발히 진행되어 왔으나, 배선 공정의 집적화와 low-k 대체에 따른 공정 및 신뢰성 문제로 인해 새로운 확산방지막의 개발이 필요하게 되었다. 이를 위해, 본 연구에서는 Cu-V 합금을 사용하여 low-k 기판 위에 확산방지막을 자가 형성 시키는 공정에 대한 연구를 진행하였다. 다양한 low-k 기판에서 열처리조건에 따른 Cu-V 합금의 특성을 확인하기 위해 4-point probe를 통한 비저항 평가와 XRD (X-ray diffraction) 분석이 이뤄졌다. 또한, TEM (transmission electron microscope)을 이용하여 $300^{\circ}C$에서 1 시간 동안 열처리를 거쳐 자가형성된 V-based interlayer가 low-k와 Cu의 계면에서 균일하게 형성된 것을 확인하였다. 형성된 V-based interlayer의 barrier 특성을 평가하고자 Cu-V합금/low-k/Si 구조와 Cu/low-k/Si 구조의 leakage current를 비교 분석하였다. Cu/low-k/Si 구조는 비교적 낮은 온도에서 leakage current가 급격히 증가하는 양상을 보였으나, Cu-V 합금/low-k/Si 구조는 $550^{\circ}C$의 thermal stress 에서도 leakage current의 변화가 거의 없었다. 이러한 결과를 바탕으로 열처리를 통해 자가형성된 V-based interlayer의 Cu/low-k 간 확산방지막으로서 가능성을 검증하였다.

  • PDF

Single-incision laparoscopic ileostomy is a safe and feasible method of fecal diversion for anastomotic leakage following laparoscopic low anterior resection

  • Hwang, Duk Yeon;Lee, Gyeo Ra;Kim, Ji Hoon;Lee, Yoon Suk
    • Annals of Surgical Treatment and Research
    • /
    • 제95권6호
    • /
    • pp.319-323
    • /
    • 2018
  • Purpose: Currently, many operations are performed using the single-incision laparoscopic method. Although there have been recent reports on single-incision laparoscopic ileostomy, none have compared this method to conventional laparoscopic ileostomy. This study aimed to assess the safety and feasibility of single-incision laparoscopic ileostomy for anastomotic leakage following laparoscopic low anterior resections. Methods: From April 2012 to April 2017, 38 patients underwent laparoscopic ileostomy (single-incision; 19 patients referred to as group A, conventional laparoscopy; 19 patients referred to as group B) for anastomotic leakage following laparoscopic low anterior resection. We analyzed surgical and clinical outcomes between the 2 groups. Patients in whom a protective ileostomy was carried out during the initial laparoscopic low anterior resection were excluded from this study. Results: No significant differences were observed between the 2 groups in terms of patient demographics and initial operation details. Incisional surgical site infections occurred less in group A than in group B (2 of 19 vs. 9 of 19, P = 0.029). The median ileostomy operation time, amount of intraoperative bleeding, parastomal hernia ratio, hospital stay duration after ileostomy, postoperative pain score were not significantly different between the 2 groups. Conclusion: Single-incision laparoscopic ileostomy is safe and feasible method of fecal diversion for anastomotic leakage following laparoscopic low anterior resection.

스마트폰 기본 동작 모드에 따른 저주파 대역 누설 전자파 신호 특성 분석 (Low-Frequency Electromagnetic Leakage Signal Analysis According to Fundamental Operations of Smartphones)

  • 이영준;박희선;권영현;이재기;최지은;조상우
    • 한국통신학회논문지
    • /
    • 제41권9호
    • /
    • pp.1108-1119
    • /
    • 2016
  • 본 논문에서는 스마트폰의 저주파 대역 누설 전자파가 미치는 악영향을 분석하기 위해 스마트폰 모델별로 기본 동작에 따라 누설되는 30 MHz 이하의 누설 전자파 신호의 스펙트럼 특성 및 방사 패턴을 분석하였다. 사용자와의 직접적인 인터페이스를 담당하는 스마트폰의 입출력 센서 모듈(터치스크린, 카메라, 마이크 및 스피커 모듈)을 활성화시키는 4가지 기본 동작 모드에 의해 누설되는 전자파 신호를 상용 Near-Field 마그네틱 프로브를 통해 1cm의 격자 간격으로 정밀하게 측정하였다. 측정된 누설 전자파 신호를 분석한 결과, 스마트폰의 모델 및 동작 모드별로 누설되는 저주파 대역 전자파는 특이한 피크(Peak) 또는 하모닉(Harmonic) 피크 성분을 보이며, 동작 모드에 따라 각각의 입출력 센서 모듈이 활성화될 경우 해당 센서 모듈 및 메인보드 상의 AP(Application Processor), 메모리 주위로 상대적으로 강한 저주파 대역의 전자파가 누설되는 것을 확인할 수 있었다.

전력간선에서의 전자파 장애를 고려한 원칩형 누설전류 원격 검출단말기의 개발 (An Development of Leakage Current Sensing Module of the System on Chip Type Under Consideration of Electromagnetic Interface in Power Trunk Line)

  • 김동완;박지호;박성원
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.377-384
    • /
    • 2009
  • In this paper, leakage current sensing module of SoC(System on Chip)type and real time monitoring system under consideration of electromagnetic interface in power trunk line are developed. The first, leakage current sensing module of SoC type under consideration of electromagnetic interface is developed, and the developed sensing module of SoC type is composed of leakage sensing part, power supply part, interface part, communication part, AD(Alternating current to Direct current)convert part and amplification part. And also the electromagnetic compatibility is evaluated by conduction and radiation of EMI(Electromagnetic Interference) for developed sensing module. The developed system can have confidence, stability and do energy saving under mixed electric circumstance of the low voltage communication device and high voltage equipment. The second, the real time remote monitoring system is developed using designed wire and wireless communication module with leakage current sensing module of SoC type. The developed real time remote monitoring system can monitor sensing state, occurrence state of leakage current and alarm for each step etc.. And the device configuration, PCB layout for leakage current sensing module of system on chip type and the experiment configuration in consideration of EMI are presented. Also the measurement results of conduction and radiation for EMI are presented.

저압 배전선로의 누전 및 배선용 차단기의 오동작 방지를 위한 고속형 전기안전 보호장치 (Electric Safety Protection Device of High Speed for Incapable Operation of ELB and MCCB Using the Low Voltage Distribution Line)

  • 곽동걸;정도영
    • 전기학회논문지
    • /
    • 제56권11호
    • /
    • pp.1925-1929
    • /
    • 2007
  • This paper is studied on a novel Electric Safety Protection Device (ESPD) of high speed for incapable operation of Earth Leakage Circuit Breaker (ELB) and Molded_case Circuit Breaker (MCCB) using the low voltage distribution line. The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Device (RCD), that is ELB and MCCB, of high sensitivity type used at low voltage wiring cuts off earth leakage and overload, but the RCD can't cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied low voltage distribution panel are prescribed to rated breaking time about 30[ms] (KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To be improved on such problem, this research development is proposed to a novel ESPD of high speed to trip of distribution line on electric arc or spark due to electrical fire. Some experimental results of the proposed ESPD are confirmed to the validity of the analytical results.

다결정 실리콘 박막트랜지스터의 누설전류 해석 (Analysis of the Leakage Current in Poly Si TFTs)

  • 이인찬;마대영;김상헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.801-802
    • /
    • 1992
  • Poly Si TFTs have been fabricated from low temperature annealed a-Si films. I-V and C-V characteristics in the off-state region were measured. Analytical model for the leakage current in the off-state was suggested. In the measurement, capacitance increased abruptly with Increasing gate and drain voltage. This phenomena is attributed to the leakage current.

  • PDF

누전차단기가 설치된 옥내전로에서의 화재위험성 (Electrical fire hazards in the domestic circuit protected by Electric Leakage circuit Breaker(ELB))

  • 홍성호;김두현;김상철;김상렬
    • 한국산업안전학회:학술대회논문집
    • /
    • 한국안전학회 1998년도 추계 학술논문발표회 논문집
    • /
    • pp.335-340
    • /
    • 1998
  • This paper presents a study on the electrical fire hazards of leakage current in a distribution circuit simulating a domestic circuit for low voltage. In this simulated circuits, total charges and energy of leakage current are calculated by a theoretical approach and compared with the results obtained from experiments, The approach and results become a cornerstone for studying and analyzing causes of electrical fires.

  • PDF