• Title/Summary/Keyword: low frequency

Search Result 11,436, Processing Time 0.061 seconds

The analgesic effect of combined electroacupuncture at Hoku (LI4) and Zusanli (ST36) using TFL (합곡혈(合谷穴)과 족삼리혈(足三里穴) 병용자극(倂用刺戟)이 TEL에 미치는 영향)

  • Baek, Kyong-Won;Ko, Eun-Sang;Min, Byung-Il;Park, Dong-Suk
    • Journal of Acupuncture Research
    • /
    • v.18 no.1
    • /
    • pp.76-87
    • /
    • 2001
  • Objective : Zusanli(ST36) and Hoku(Li4) are analgesic acupuncture points frequently used for acupuncture in Oriental medicine. The present study was conducted to see the antinociceptive effects produced by electroacupuncture combined two frequencies(Low, High) and two different acupuncture points(LI4, ST36) in the rat tail flick test. Method : In this study the Rats (Sprague-Dawley, 250-300g) were partially anesthetized with thiopental sodium(40mg/kg, i.p.). The basal reaction time for the tail-flick was 3${\pm}$0.5 sec. Low frequency(3Hz, 5V, biphasic) and high frequency(100Hz, 5V, biphasic) were applied to the inserted needle for the period of insertion(twenty minutes). Experimental groups are divied as follow; a) electroacupuncture stimulation groups at Hoku with or high frequency(L-EA, H-EA), b) electroacupuncture stimulation groups at Zusanli with low or high frequency(1-EA, h-EA), c) low frequency at Hoku and Zusanli(LIEA), d) low frequency at Hoku and high frequency at Zusanli(LhEA), e) high frequency at Hoku and low frequency at Zusanli(HIEA), f) high frequency at Hoku and Zusanli(HhEA) Results : The individual stimulation at either Hoku or Zusanli with low frequency has stronger and longer analgesic effect than high frequency stimulation. In addition, the combined stimulation at Hoku and Zusanli with low frequency has superior effect to individual stimulation with low frequency. LhEA and LIEA have superior effect to other stimulation groups among the combined groups. In order to determine the involvement of opioid system on the different antinociceptive effects, Naloxone, an opioid antagonist, was used in the combined groups. LIEA is the most sensitive when naloxone was administrated among study groups. HhEA is the least sensitive in the administration of naloxone. Conclusion : From results, this study confirmed that the opioid system is involved in analgesic effect of low frequency stimulation of acupuncture point, and we also can suggest the stronger analgesic effect of combining stimulation points is due to the theory of spatial summation in the nervous system.

  • PDF

Effect of low frequency oscillations during milking on udder temperature and welfare of dairy cows

  • Antanas Sederevicius;Vaidas Oberauskas;Rasa Zelvyte;Judita Zymantiene;Kristina Musayeva;Juozas Zemaitis;Vytautas Jurenas;Algimantas Bubulis;Joris Vezys
    • Journal of Animal Science and Technology
    • /
    • v.65 no.1
    • /
    • pp.244-257
    • /
    • 2023
  • The study aimed to investigate the effect of low-frequency oscillations on the cow udder, milk parameters, and animal welfare during the automated milking process. The study's objective was to investigate the impact of low-frequency oscillations on the udder and teats' blood circulation by creating a mathematical model of mammary glands, using milkers and vibrators to analyze the theoretical dynamics of oscillations. The mechanical vibration device developed and tested in the study was mounted on a DeLaval automatic milking machine, which excited the udder with low-frequency oscillations, allowing the analysis of input parameters (temperature, oscillation amplitude) and using feedback data, changing the device parameters such as vibration frequency and duration. The experimental study was performed using an artificial cow's udder model with and without milk and a DeLaval milking machine, exciting the model with low-frequency harmonic oscillations (frequency range 15-60 Hz, vibration amplitude 2-5 mm). The investigation in vitro applying low-frequency of the vibration system's first-order frequencies in lateral (X) direction showed the low-frequency values of 23.5-26.5 Hz (effective frequency of the simulation analysis was 25.0 Hz). The tested values of the first-order frequency of the vibration system in the vertical (Y) direction were 37.5-41.5 Hz (effective frequency of the simulation analysis was 41.0 Hz), with higher amplitude and lower vibration damping. During in vivo experiments, while milking, the vibrator was inducing mechanical milking-similar vibrations in the udder. The vibrations were spreading to the entire udder and caused physiotherapeutic effects such as activated physiological processes and increased udder base temperature by 0.57℃ (p < 0.001), thus increasing blood flow in the udder. Used low-frequency vibrations did not significantly affect milk yield, milk composition, milk quality indicators, and animal welfare. The investigation results showed that applying low-frequency vibration on a cow udder during automatic milking is a non-invasive, efficient method to stimulate blood circulation in the udder and improve teat and udder health without changing milk quality and production. Further studies will be carried out in the following research phase on clinical and subclinical mastitis cows.

Interior Noise and Low Frequency Noise Characteristics of Busan Metro Line 3 Noise (부산도시철도 3호선 실내소음 및 저주파 소음 특성)

  • Hong, Do-Kwan;Jeong, Jae-Boo;Jung, Seung-Wook;Gang, Hyun-Wook;Ahn, Chan-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.11
    • /
    • pp.1113-1120
    • /
    • 2012
  • This paper deals with the analysis of interior noise and low frequency noise characteristic for the Busan citizens to use public transport, Busan Metro Line 3. The interior noise evaluation index, articulation index(AI) is evaluated the lower value about average 22 % in a whole range, this is difficult to have a conversation. Also, noise criteria(NC) curve is partially evaluated as NC-65 below 2000 Hz, space type is evaluated as factories. Another of interior noise evaluation index, preferred speech interference level(PSIL) is evaluated the upper value about average 66 dB(A) in a whole range, this is evaluated to be interrupted. In the case of low frequency noise(20~200 Hz), the measurement of low frequency noise is assessed largely beyond noise criteria of ISO 226. The low frequency noise should be reduced because low frequency noise affects on psychological stress and displeasure although low frequency noise is not recognized by auditory sense. The low frequency noise criteria and guideline will be enacted from now on in Korea.

Effect of Load Modeling on Low Frequency Current Ripple in Fuel Cell Generation Systems

  • Kim, Jong-Soo;Choe, Gyu-Yeong;Kang, Hyun-Soo;Lee, Byoung-Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.307-318
    • /
    • 2010
  • In this work, an accurate analysis of low frequency current ripple in residential fuel cell power generation systems is performed based on the proposed residential load model and its unique operation algorithm. Rather than using a constant dc voltage source, a proton exchange membrane fuel cell (PEMFC) model is implemented in this research so that a system-level analysis considering the fuel cell stack, power conditioning system (PCS), and the actual load is possible. Using the attained results, a comparative study regarding the discrepancies of low frequency current ripple between a simple resistor load and a realistic residential load is performed. The data indicate that the low frequency current ripple of the proposed residential load model is increased by more than a factor of two when compared to the low frequency current ripple of a simple resistor load under identical conditions. Theoretical analysis, simulation data, and experimental results are provided, along with a model of the load usage pattern of low frequency current ripples.

Experimental investigation into infrasound and low-frequency noise radiation characteristics from large wind turbines (중대형 풍력터빈의 저주파 및 초저주파 소음 방사 특성에 대한 실험적 고찰)

  • Lee, Seung-Yub;Cheong, Cheol-Ung;Shin, Su-Hyun;Jung, Sung-Soo;Cheung, Wan-Sup
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1482-1489
    • /
    • 2007
  • In this paper, characteristics of infrasound and low-frequency noise emission from large modern wind turbines are experimentally investigated. The sound measurement procedures of IEC 61400-11 and ISO 7196 are utilized to field test and evaluation of noise emission from each of 1.5 MW and 660 kW wind turbines using the stall regulation and the pitch control for the power regulation, respectively. It was found that the G-weighted SPLs of low-frequency noise including infrasound shows positive correlation with the wind speeds, irrespective of methods of power regulation. This highlights the potential complaint of local community against the infrasound and low-frequency noise of wind turbines. The comparison of measured data with the existing hearing thresholds and criteria curves shows that it is highly probable that the low-frequency noise from the 1.5 MW and 660 kW wind turbines in the frequency range over 30 Hz leads to the psychological complaint of ordinary adults, and that the infrasound in the frequency range from 5 Hz to 8 Hz causes the complaint by rattling the house fitting such as doors and windows.

  • PDF

High Frequency Noise Reduction Method Using a Newly Designed Low-pass Filter in DFT-Based Phasor Estimation (DFT 기반 페이저 연산 시 새로운 저역통과필터를 이용한 고주파 노이즈 경감 방법)

  • Baek, Min-Woo;Kang, Sang-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.6
    • /
    • pp.898-904
    • /
    • 2017
  • DFT(Discrete Fourier Transform) is one of the most widely used method to estimate the phasor of a relaying signal. The harmonics are eliminated by the DFT. However, high frequency components, except for harmonics, are not removed and cause an error in DFT-based phasor estimation process. This paper suggests high frequency noise reduction method by using a newly designed low-pass filter to estimate a signal phasor. When selecting a stop-band cut-off frequency of the low-pass filter, high frequency components generated by faults are considered. To reduce the phasor estimation delay caused by a low-pass filter, this paper proposes a low-pass filter whose settling time is reduced. An adverse effect of high frequency noise on DFT-based phasor estimation is reduced. To evaluate the performance of the proposed method, signals which are collected under a fault condition at a 345[kV] transmission system modeled by EMTP-RV are used.

The Effect of Acupuncture and Electro-acupuncture at ST41 on Experimentally-induced Intestinal Hypo-motility in Rats: Comparison between Pre-treatment and Post-treatment (해계(解谿)(ST41) 유침 및 전침의 전.후처치가 loperamide로 억제된 흰쥐의 장운동에 미치는 영향)

  • Kim, KyungMin;Lee, Hyun;Yim, YunKyoung
    • The Journal of Korean Medicine
    • /
    • v.33 no.3
    • /
    • pp.20-32
    • /
    • 2012
  • Objectives: The purpose of this study was to investigate the effect of acupuncture and electro-acupuncture (EA) of low and high frequencies at Haegye (ST41) in rats. Methods: The intestinal motility of rats was experimentally suppressed with loperamide. Acupuncture, low frequency EA and high frequency EA were carried out before the loperamide administration in the pre-treatment group, and after the loperamide administration in the post-treatment group. The rats were fed charcoal and the travel rate of charcoal in the gastrointestinal track was measured to analyze the effect of acupuncture, low frequency EA and high frequency EA on the intestinal hypo-motility. Results: 1. None of acupuncture, low frequency EA or high frequency EA at ST41 showed significant influences on intestinal motility of rats in normal status. 2. Pre-treatment with acupuncture at ST41 showed no significant effect on the intestinal hypo-motility induced by loperamide in rats. 3. Pre-treatment with low frequency EA and high frequency EA at ST41 significantly reduced the suppression of intestinal motility by loperamide in rats. 4. Post-treatment of acupuncture, low frequency EA and high frequency EA at ST41 had no significant influences on the intestinal hypo-motility induced by loperamide in rats. Conclusions: These results suggest that low and high frequency EA at ST41 may be effective to prevent gastric disorders such as intestinal hypo-motility.

A Study on the Squeal Noise Instability Analysis on Caliper Brake (캘리퍼 브레이크 스퀼 소음의 불안정성 해석에 관한 연구)

  • Lee, Junghwan;Kim, Seonghwan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.11
    • /
    • pp.957-965
    • /
    • 2013
  • This paper deals with analytical methods for low frequency and high frequency brake squeal noise on brake-rear caliper. In order to improve low frequency and high frequency squeal noise, we take survey caliper bracket shape parameters and housing shape parameters. Besides, using the combination of bracket and housing parameter were surveyed. Thus, using the combination of bracket Alt_05 and housing Alt_45 specifications, instability analysis and brake dynamo test were carried out. Based upon the two models, low and high frequency squeal noise of base model were improved. But, for 6.0 kHz frequency noise, which is not improved, it needs to additionally study on instability analysis and combination of the other brake components.

An Estimation method for Characteristic Parameters in a Low Frequency Signal Transformed by High Frequency Signals (고주파 신호에 의하여 변형된 저주파신호에서의 특성변수 추정 기법)

  • Yoo, Kyung-Yul
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.2
    • /
    • pp.86-88
    • /
    • 2002
  • An estimation method for the characteristic parameters in the low frequency signal is proposed in this paper. A low frequency signal is assumed to be modulated or distorted by high frequency terms. The algorithm proposed in this paper is designed to select set of local maximums in a successive manner, hence it is denoted as the iterative peak picking(IPP) algorithm. The IPP algorithm is operating in the time domain and is using only the comparison operation between two neighboring samples. Therefore, its computational complexity is very low and the delay caused by the computation is negligible, which make the real-time operation possible with economic hardware. The proposed algorithm is verified on the pitch estimation of speech signal and blood pulse estimation.

Study on Low Frequency Characteristics of Rotary Compressor (로타리 압축기 저주파 특성에 관한 연구)

  • Byoungha Kwon;Park, Sinkyu;Insu Hwang
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.384.2-384
    • /
    • 2002
  • Compressor is a major noise source of air-conditioner. Especially, its low frequency band noise below 1000㎐ is very important because it will not be attenuated by passing through the cover panel and heat exchanger in air-conditioner. The factors affecting the low frequency band noise are studied by geometric similarity along with several experiments, and the low frequency noise is closely related with the discharge holes of muffler as well as the cavity of lower shell. (omitted)

  • PDF