• 제목/요약/키워드: low frequency

Search Result 11,436, Processing Time 0.039 seconds

A 360Hz DC Ripple-Voltage Suppression Scheme in Three-Phase Soft-Switched Buck Converter (360Hz DC 리플-전압 감소기법을 사용한 3-Phase Soft-Switched Buck Converter)

  • Choi, Ju-Yeop;Ko, Jong-Jin;Song, Joong-Ho;Choy, Ick;Jeong, Seung-Gi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.12
    • /
    • pp.813-820
    • /
    • 2000
  • A technique to suppress the low frequency ripple voltage of the DC output in three phase buck diode converter is presented in this paper. The proposed pulse frequency modulation methods and duty ratio modulation methods are employed to regulate the output voltage of the buck diode converter and guarantee zero-current-switching(ZCS) of the switch over the wide load range. The proposed control methods used in this paper provide generally good performance such as low THD of the input line current and unity power factor. In addition, control methods can be effectively used to suppress the low frequency ripple voltage appeared in the dc output voltage. The harmonic injection technique illustrates its validity and effectiveness through the simulations and experiments.

  • PDF

Change in Autonomic Nerve Responses after Low-frequency Transcutaneous Electrical Nerve Stimulation

  • Lee, Jeong-Woo;Park, Ah-Rong;Hwang, Tae-Yeon
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.6
    • /
    • pp.71-76
    • /
    • 2010
  • Purpose: The purpose of this study was to examine changes in autonomic nerve responses after low-frequency transcutaneous electrical nerve stimulation (TENS). Methods: Research subjects were 24 students who attend University. Subjects were divided into two groups: 1 = a low intensity group; 2 = a high intensity group. Electrodes were attached to the forearm of the dominant arm and electrical stimuli were administered for 15 minutes. Outcome measures were skin conduction velocity, skin temperature, blood flow, and pulse frequency, each of which was measured a total of 4 times. The data were analyzed using a repeated measures ANOVA. Results: In changes in conduction velocity, the main effect of time variation (in black) was statistically significant. The interaction between time and group main effects was not statistically significant; nor was the difference between the groups. Results showed that skin conduction velocity changed without any relation to group. Conclusions: Low frequency TENS selectively increases skin conduction velocity, which may be helpful for activating sudomotor function regardless of intensity.

Modified TEM Horn for Enhanced Radiation Characteristics at Low Frequency

  • Kim, Jae Sik;Park, Hyeong Soon;Yoon, Young Joong;Ryu, Jiheon;Choi, Jin Soo
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.2
    • /
    • pp.74-78
    • /
    • 2014
  • This paper presents a modified TEM horn that improves radiation characteristics at a low frequency region. The proposed antenna consists of an asymmetric TEM (ATEM) horn and a loop structure with an elliptical shape. The bandwidth and gain at low frequency region can be enhanced by using the ATEM horn configuration and adding a loop structure with an elliptical shape to the ATEM horn. The bandwidth of the proposed antenna is from 2.14 to over 20 GHz, whereas that of the conventional TEM horn is from 2.7 to over 20 GHz, where the dimensions of both antennas are the same except for the thickness of the loop structure. The physical and electrical dimensions of the proposed antenna are $60mm{\times}62.5mm{\times}64mm$ ($width{\times}height{\times}length$) and $0.428{\lambda}_L{\times}0.445{\lambda}_L{\times}0.456{\lambda}_L$, where ${\lambda}_L$ corresponds to the lowest frequency of the bandwidth. The realized gain of the proposed antenna is improved by 0.802 dB on average at the low frequency region (2 to 8 GHz), where the maximum gain increase is 2.932 dB when compared to a conventional TEM horn.

Experimental study on characteristic of sloshing impact load in elastic tank with low and partial filling under rolling coupled pitching

  • Wu, Wenfeng;Zhen, Changwen;Lu, Jinshu;Tu, Jiaoyang;Zhang, Jianwei;Yang, Yubin;Zhu, Kebi;Duan, Junxian
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.12 no.1
    • /
    • pp.178-183
    • /
    • 2020
  • A series of experiments covering lowest three natural frequencies of rolling coupled pitching were conducted to investigate liquid sloshing with low liquid depth. The test results show that the most violent liquid sloshing in rolling and pitching is located in the vicinity of the first order natural frequency (f1). When the excitation frequency of rolling and pitching is located between 0.98f1 and 1.113f1, roof-bursting phenomenon of liquid appeared, and the maximum impact pressure is at 1.09f1. When the external excitation frequency is at 1.113f1, the number of sloshing shocks decreases sharply. Furthermore, the space distribution of the impact pressure on the left bulkhead and the top bulkhead was analyzed. It is concluded that with low liquid filling, the impact load is greater near the free surface and the top of tank, and the impact position of the side bulkhead increases with the increasing of the frequency near the resonant frequency.

Reinforcing Stethoscope Sound using Spectral Shift (스펙트럼 이동을 이용한 청진음 강화)

  • Jung, Dong Keun
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.1
    • /
    • pp.47-50
    • /
    • 2021
  • Human hearing sensitivity is frequency-dependent. The sensitivity is low at both ends of the audible frequency, and the sensitivity is the highest in the middle band at 3000 Hz. The heart sound of a healthy person is concentrated at a low frequency of 200 Hz or less, and despite using a stethoscope, the hearing sensitivity of the human body is low, and the stethoscope sound is low. Amplifying the sound of the stethoscope is not effective in distinguishing heart sounds in noisy environments because it maintains the same signal-to-noise ratio. In this study, a method of enhancing auditory stimulation was developed by applying a method of moving the spectrum of auscultation sounds into a high-frequency region where the human body is highly sensitive to hearing. The spectrum of the auscultation sound was moved up by 500 Hz in the frequency domain, and an inverse fast Fourier transform (FFT) was performed to reconstruct the auscultation sound. The heart sounds reconstructed by moving the spectra were divided into the first heart and second heart sound components, as in the original heart sound, and it was confirmed that the intensity was large in the cochleagram representing auditory stimulation. Therefore, this study suggested that spectral shift is a method to enhance auditory stimulation during auscultation without increasing the intensity of the auscultation sound.

The Influence of Position Change on Autonomic Nervous System Function (자세변화가 자율신경계에 미치는 영향)

  • Kim, In-Bae;Kim, Eun-Kyung;Kang, Jong-Ho
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.1
    • /
    • pp.63-68
    • /
    • 2014
  • PURPOSE: The purpose of this study was to examine the position changes with tilt table on autonomic nervous system using heart rate variability analysis. METHODS: Fourty healthy adult males volunteered in this study. The low frequency, high frequency and low frequency/high frequency ratio and mean heart rate, standard deviation of all normal R-R intervals, root mean square of successive differences, heart rate variability index were measured at the tilt table angle of $0^{\circ}$, $45^{\circ}$ and $90^{\circ}$ with pulsoximeter. Data were analyzed one-way ANOVA and LSD post hoc test. RESULTS: The mean heart rate, low frequency and low frequency/high frequency ratio increased significantly at higher angle of tilt table(p<.05). The root mean square of successive differences, heart rate variability index decreased significantly at lower angle of tilt table(p<.05). The standard deviation of all normal R-R intervals, high frequency decreased at higher angle of tilt table did not show significant difference. CONCLUSION: The symphathetic activity increased significantly at higher angle of tilt table. The parasymphathetic activity decreased at higher angle of tilt table, but the difference were not significant. The autonomic adaptation, balance and heart rate variability decreased significantly at higher angle of tilt table. Based on these results, in the treatment of patients with a change in posture precedence should be carefully treated. Further studies are necessary to determine the most safety and effective methods.

Heart Rate Variability and Metabolic Syndrome in Hospitalized Patients with Schizophrenia

  • Lee, Kyung-Hee;Park, Jeong-Eon;Choi, Jeong-Im;Park, Chang-Gi
    • Journal of Korean Academy of Nursing
    • /
    • v.41 no.6
    • /
    • pp.788-794
    • /
    • 2011
  • Purpose: Reduced heart rate variability significantly increases cardiovascular mortality. Metabolic syndrome increases the cardiac autonomic dysfunction. Recently, increasing cardiovascular mortality has been reported in patients with schizophrenia. This study was done to compare heart rate variability between adults with and without schizophrenia and to compare the relationship of heart rate variability to metabolic syndrome in hospitalized patients with schizophrenia. Methods: This was a descriptive and correlational study in which 719 adults without schizophrenia and 308 adults with schizophrenia took part between May and June 2008. We measured the following: five-minute heart rate variability; high-frequency, low-frequency, the ratio of low-frequency to high-frequency, and the Standard Deviation of all the normal RR intervals. Data was also collected on metabolic syndrome, abdominal obesity, triglycerides, HDL cholesterol, blood pressure and fasting glucose. Results: The Standard Deviation of all the normal RR intervals values of heart rate variability indices were $1.53{\pm}0.18$. The low-frequency and high-frequency values of heart rate variability indices were significantly higher in hospitalized patients with schizophrenia ($3.89{\pm}1.36$; $3.80{\pm}1.20$) than those in the healthy participants ($2.20{\pm}0.46$; $2.10{\pm}0.46$). There were no significant differences between the schizophrenic patients with and without metabolic syndrome. Conclusion: The results of this study indicate that schizophrenia patients have significantly lower cardiac autonomic control, but they have significantly higher low-frequency and high-frequency values than those of healthy adults. Use of antipsychotic drug may affect the autonomic nervous system in schizophrenic patients. Metabolic syndrome was not associated with cardiac autonomic control in schizophrenia patients.

The Effects of Electroacupuncture on Mechanical Allodynia and Its Involvement with the Sympathetic Nervous System (Tail model의 기계적 이질통에 대한 전침 자극의 효과 및 교감신경계의 관여기전)

  • Lee, Hyung-suk;Min, Byung-il;Hwang, Byung-gil;Park, Dong-suk;Lee, Soon-geul
    • Journal of Acupuncture Research
    • /
    • v.20 no.1
    • /
    • pp.177-190
    • /
    • 2003
  • Objective : This study was intended to investigate the analgesic effects of electroacupuncture(EA) on mechanical allodynia according to the frequency and intensity of EA. Also to know if mechanical allodynia and the analgesic effects of EA is related to the sympathetci nervous system and/or the purinergic system. Methods : mechanical allodynia-induced rats were produced by resecting S1-S2 nerve. The zusanli(ST36) was used for acupoint and the rats were divided into 4 groups. Each group was given different stimuli[low frequency low intensity-EA(LFLI-EA), low frequency high intensity-EA(LFHI-EA), high frequency low intensity-EA(LFHI-EA), high frequency high intensity-EA(HFHI-EA)]. Futhermore, to make sympathectomy6-OHDA and phentolamine were administered intraperitonially and the concentration of norepinephrine(NE) were measured. As a ATP blocker, suramin was applied for this study. Results : Comparing to control group, each of the 4 groups(LFLI-EA, LFHI-EA, HFLI-EA, HFHI-EA) showed a significant reduction of response frequency of mechanical allodynia. LFHI-EA was more effective than that of LFLI-EA. The LFHI-EA group also had longer lasting effects from the stimulation than the other groups. Sympathectomy didn't show any reduction of response frequency of mechanical allodynia.(Each n=6, n=4). Nor did both sympathectomy and ATP block. The response frequency wasn't reduced by sympathectomy or by sympathectomy and ATP block, but was significantly reduced with LFHI-EA Conclusions : These results suggest that EA has a significant analgesic effect on mechanical allodynia which has no connection with NE and/or ATP.

  • PDF

The Effect of the Physical Therapy Treatment Room Environment Using Microwave Diathermy on the Autonomic Nervous System of Human Body (극초단파치료기를 사용하는 물리치료실의 환경이 물리치료사의 인체자율신경계에 미치는 영향)

  • Shin, Han-Ki;Lee, Tae-Kyu;Jun, Je-Yoon;Kim, Ju-Seung;Kang, Jong-Ho
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.1
    • /
    • pp.37-43
    • /
    • 2015
  • PURPOSE: The purpose of this study is to investigate the effect of the physical therapy treatment room environment using microwave diathermy on the autonomic nervous system of human body. METHODS: Participants were 24 healthy adults. Standard deviation of all normal R-R intervals(SDNN), root mean square of successive differences(RMSSD), low frequency(LF), high frequency(HF), LF/HF ratio were compared in microwave irradiation and non-irradiation group. Data were analyzed in Wilcoxon's signed-ranks test and Mann-Whitney U test. RESULTS: Standard deviation of all normal R-R intervals (SDNN), root mean square of successive differences (RMSSD), low frequency(LF), high frequency(HF), LF/HF ratio were not significantly different in microwave irradiation group. Standard deviation of all normal R-R intervals(SDNN), root mean square of successive differences (RMSSD), low frequency(LF), high frequency(HF), LF/HF ratio were not significantly different in microwave non-irradiation group. Standard deviation of all normal R-R intervals(SDNN), root mean square of successive differences (RMSSD), low frequency(LF), high frequency(HF), LF/HF ratio were not significantly different between two groups. CONCLUSION: There was no significant change in the sympathetic nervous system and parasympathetic nervous system regardless of the presence of microwave irradiation. There was no significant change in the autonomic nervous system adaptability regardless of the presence of microwave irradiation.According to this study, microwave diathermy does not have significant effect on the autonomic nervous system.Future study is necessary to investigate the long term effect of the physical therapy treatment room environment using microwave diathermy on the autonomic nervous system of the human body.

The Effect of Electroacupuncture on the Heart Rate Variability of Stroke Patients under Mental Arithmetic Stress

  • Oh, Jae-Gun;Kwon, So-Yeon;Yun, Henja;Sung, Kang-Keyng
    • The Journal of Korean Medicine
    • /
    • v.33 no.4
    • /
    • pp.50-59
    • /
    • 2012
  • Objectives: This study aimed to compare the effects of high frequency electroacupuncture, low frequency electroacupuncture and manual acupuncture on the autonomic nervous system in stroke patients by using a heart rate variability measuring device. Methods: Thirty-nine participants were recruited and each participated in the high frequency electroacupuncture group, low frequency electroacupuncture group, manual acupuncture group and non-acupuncture group. Some participants received needle insertion with 100 Hz stimulation, with 2Hz stimulation and manual stimulation under mental arithmetic stress during 2 sections. Other participants maintained in the supine position without acupuncture under mental arithmetic stress during the 2 sections. Acupuncture needles were directly inserted perpendicularly to the right Liv 3 acupoint followed by delivery of electric pulses to these points for 8 minutes. Heart rate variability was measured 8 minutes before and 16 minutes after acupuncture stimulation by a heart rate variability measuring system. Results: We found a significant elevated HF total power between 1 section and 2 section and between 1 section and 4 section in the non-acupuncture group, between 3 section and 4 section in the 100Hz electroacupuncture group, and between 1 section and 2 section in the manual acupuncture group and with no change in the 2Hz electroacupuncture group. We also found a significant VLF total power between 2 section and 3 section in the 2Hz electroacupuncture group and between 1 section and 4 section and between 2 section and 4 section in the 100Hz electroacupuncture group. All four groups showed no significant differences in other parameters including heart rate mean, low-frequency power, and the ratio of low-frequency power to high-frequency power. Conclusions: This study may be a basis for research about effects of acupuncture and electroacupuncture because the parameters measured, heart rate variability, showed differences according to acupuncture.