• 제목/요약/키워드: low frequencies

검색결과 1,473건 처리시간 0.03초

Synthesis of Forsterite with High Q and Near Zero TCf for Microwave/Millimeterwave Dielectrics

  • Ohsato, Hitoshi;Ando, Minato;Tsunooka, Tsutomu
    • 한국세라믹학회지
    • /
    • 제44권11호
    • /
    • pp.597-606
    • /
    • 2007
  • With the advent of ubiquitous age, the high quality dielectric materials have been required for the wireless communications available to the millimeterwave as well as microwave frequencies. The utilizable region for the frequency has been expanding to the millimeter-wave region because of the shortage of radio frequency (RF) resources. These high frequencies would be expected for ultra high speed LAN, ETS and car anti-collision system on the intelligent transport system (ITS) and so on. Silicates are good candidates for microwave/millimeterwave dielectrics, because of their low dielectric constant ${\epsilon}_r$ and high quality factor (High Q). Forsterite ($Mg_2SiO_4$) is one of the silicates with low ${\epsilon}_r$ of 6.8 and Q f of 240000 GHz. In this paper, we reviewed following three categories for synthesis of forsterite: (1) Synthesis of high Q forsterite (2) Adjust the temperature coefficient of resonant frequency $TC_f$ (3) Diffusion of $SiO_{4^-}$ and Mg-ions on the formation of forsterite.

EMC 모노폴 안테나의 복소 안테나 인자 (Complex Antenna Factors of EMC Monopole Antenna)

  • 김기채
    • 한국전자파학회논문지
    • /
    • 제11권8호
    • /
    • pp.1322-1328
    • /
    • 2000
  • 본 논문에서는 전자계의 시간 변화 파형을 측정하기 위한 모노폴 안테나의 복소 안테나 인자 및 전달함수의 주파수 응답 특성 등을 논의하고 있다. 안테나에 흐르는 전류분포는 구분적 정현함수를 사용한 Galerkin의 모멘트법으로 계산하고 있으며 저주파수 대역에서는 반사를 줄이기 위해 칩저항을 접속한 경우의 복소 안테나 인자에 대하여 검토하고 있다. 이론 해석의 결과, 칩저항이 접속된 경우는 접속하지 않은 경우보다 복소 안테나 인자의 절대치는 5.6㏈정도 커진다는 것을 확인하였다. 또한, 주파수가 낮은 경우에 유용하게 사용할 수 있는 변형 복소 안테나 인자의 특성에 대해서도 논의하고 있다. 근역장 보정법으로 측정된 복소 안테나 인자와도 비교하여 이론 계산의 타당성을 확인하고 있다.

  • PDF

농촌지역 노인의 짠맛 기호도와 식습관 및 건강 위험인자와의 관계 (The Relationship between Dietary Behaviors/health Risk Factors and Preference for Salty Taste among Korean Elderly People Living in Rural Areas)

  • 이미숙
    • 대한지역사회영양학회지
    • /
    • 제19권5호
    • /
    • pp.448-458
    • /
    • 2014
  • Objectives: Increasing salt preferences with age are said to increase preferences of salty foods, thereby leading to greater sodium consumption, which has further implication for hypertension. This study examined the link between preference of salty taste and dietary factors and health-related risk factors in Korean elderly people. Methods: We studied 312 elderly individuals aged > 65 years (male, 100 and female, 212). With each subject, pleasant concentration of NaCl was estimated using the sip-and-spit method. Dietary habits, food preferences, consumption frequencies, anthropometric and biochemical assessment were assessed. Results: The pleasant salt concentration was significantly increased in individuals older than 75 years (p < 0.05). Subjects who liked high concentration of salt showed significantly higher preferences for salty foods (p < 0.001). Results showed significant effects (p < 0.01) of fruit & fruit juice consumption frequencies, MNA (mini-nutritional assessment), cognition score, BMI, body fat %, waist circumference, arm circumference, calf circumference, vitamin D level that subjects who likes low salty taste were higher than subjects who likes high salty taste. Conclusions: The preference for salty taste in the elderly was not correlated with hypertension. But, increased preference for salty taste with age and increased salty food preferences may result in higher sodium consumption. Therefore, nutritional education regarding lowering salt preference and favorable behaviors of low-salt diet is needed to improve the quality of life in the rural elderly.

Numerical investigation of film boiling heat transfer on the horizontal surface in an oscillating system with low frequencies

  • An, Young Seock;Kim, Byoung Jae
    • Nuclear Engineering and Technology
    • /
    • 제52권5호
    • /
    • pp.918-924
    • /
    • 2020
  • Film boiling is of great importance in nuclear safety as it directly influences the integrity of nuclear fuel in case of accidents involving loss of coolant. Recently, nuclear power plant safety under earthquake conditions has received much attention. However, to the best of our knowledge, there are no existing studies reporting film boiling in an oscillating system. Most previous studies for film boiling were performed on stationary systems. In this study, numerical simulations were performed for saturated film boiling of water on a horizontal surface under low frequencies to investigate the effect of system oscillation on film boiling heat transfer. A coupled level-set and volume-of-fluid method was used to track the interface between the vapor and liquid phases. With a fixed oscillation amplitude, overall, heat transfer decreases with oscillation frequency. However, there is a frequency region in which heat transfer remains nearly constant. This lock-on phenomenon occurs when the oscillation frequency is near the natural bubble release frequency. With a fixed oscillation frequency, heat transfer decreases with oscillation amplitude. With a fixed maximum amplitude of the additional gravity, heat transfer is affected little by the combination of oscillation amplitude and frequency.

Warped Common Acoustical Pole and Zero 방법을 이용한 효율적인 공간 등화 (Effective Room Equalization Using Warped Common Acoustical Pole and Zero)

  • 이준호;박영철;윤대희;이석필
    • 한국음향학회지
    • /
    • 제28권1호
    • /
    • pp.51-60
    • /
    • 2009
  • 본 논문에서는 warped common acoustical pole and zero (WCAPZ) 모델링 방법을 이용한 새로운 공간 등화 방법을 제안한다. 제안한 방법은 저주파 영역의 등화 성능을 감소시키지 않으면서 등화 필터의 차수를 줄일 수 있는 장점을 가진다. 따라서 제안된 공간 등화 시스템은 기존의 블록 변환 방법에 비해 연산량은 비슷하면서도 적은 입출력 지연을 가지게 된다. 컴퓨터 모의실험을 통해 제안된 방법이 기존의 기법에 비해 저주파 영역에서 좋은 공간 등화 성능을 보임을 검증하였다.

Low Frequency Perception of Rhythm and Intonation Speech Patterns by Normal Hearing Adults

  • Kim, Young-Sun;Asp, Carl-W.
    • 음성과학
    • /
    • 제9권1호
    • /
    • pp.7-16
    • /
    • 2002
  • This study tested normal hearing adults' auditory perception of rhythm and intonation patterns, with low-frequency speech energy. The results showed that the narrow-band low-frequency zones of 125, 250, or 500 Hz provided the same important rhythm and intonation cues as did the wide-band condition. This suggested that an auditory training strategy that uses low-frequency filters would be effective for structuring or re-structuring the perception of rhythm and intonation patterns. These filters force the client to focus on these patterns, because the speech intelligibility is drastically reduced. This strategy can be used with both normal-hearing and hearing impaired children and adults with poor listening skills, and possibly poor speech intelligibility.

  • PDF

SUS304강의 사이클의존형에서 시간의존형균열성장으로의 천이에 관한 연구 (A Study on Transition From Cycle-dependent to Time-dependent Crack Growth in SUS304 Stainless Steel)

  • 주원식;조석수
    • Journal of Welding and Joining
    • /
    • 제14권1호
    • /
    • pp.38-46
    • /
    • 1996
  • High temperature low cycle fatigue crack growth behavior is investigated over a range of two temperatures and various frequencies in SUS 304 stainless steel. It is found that low frequency and temperature can enhance time-dependent crack growth. With high temperature, low frequency and long crack length, ${\Delta}J_c/{\Delta}J_ f$, the ratio of creep J integral range to fatigue J integral range is increased and time-dependent crack growth is accelerated. Interaction between ${\Delta}J_f$ and ${\Delta}J_c$ is occured at high frequency and low temparature and ${\Delta}J_c$, creep J integral range is fracture mechanical parameter on transition from cycle-dependent to time dependent crack growth in creep temperature region.

  • PDF

16Kbps와 40Kbps의 Dual Rate G.723 ADPCM 음성 codec 구현 (Implementation of Dual Rate G.723 ADPCM Speech codec)

  • 김재오;한경호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 G
    • /
    • pp.2480-2482
    • /
    • 1998
  • In this paper, the implementation of dual rate ADPCM using G.723 16Kbps and 40Kbps speech codec algorithm is handled. For small signals, the low rate 16Kbps coding algorithm shows the same SNR as the high rate 40Kbps coding algorithm, while the low rate 16Kbps coding algorithm shows the lower SNR than the high rate 40Kbps coding algorithm for large signal. To obtain the good trade-off between the data rate and synthesized speech quality, we applied low rate 16Kbps for the small signal and high rate 40Kbps for the large signal. Various threshold values determining the rate are tested for good trade off data rate and speech quality. Also the low pass filter effect of speech input and output devices is simulated at several cut-off frequencies. To simulation result shows the good speech quality at a low rate comparing with 16Kbps & 40Kbps.

  • PDF

앉은 자세에서 힘 수준에 따른 상지관절 동작별 최대 수용 반복 빈도수 분석 (Analysis of Maximum Acceptable Frequencies for Upper Extremity Motions with Forces in a Seated Position)

  • 권오채;유희천;정기효
    • 대한인간공학회지
    • /
    • 제24권2호
    • /
    • pp.65-70
    • /
    • 2005
  • Evaluation of repetitiveness for upper extremity intensive tasks is essential to determine the level of risk for upper extremity musculoskeletal disorders at the workplace. However, experimental data available to establish the acceptable levels of repetitiveness for various postures and forces is lacking. The present study examined the maximum acceptable frequencies(MAFs; motions/min.) of shoulder, elbow, wrist, and index finger motions at different forces(1kgf and 4kgf for shoulder, elbow, and wrist; 0.25kgf and 1 kgf for index finger) in sitting. Seventeen right-handed males in 20s without having any history musculoskeletal disorders participated in the MAF experiment. The participants determined their MAFs for the upper extremity motions by using the self-adjustment method and their work pulse(increase in heart rate; beats/min.) and rating of perceived exertion(RPE) were measured when working at MAF. The MAFs of elbow, wrist, and index finger motions for each force level were about 2, 3, and 6 times the corresponding MAF(9 at the high force and 24 at the low force) of shoulder motion and the MAFs at the low force increased about 2 times those at the high force. The work pulses of elbow, wrist, and index finger motions for each force level were 70%, 50%, and 30% of the corresponding work pulse(17 at the high force and 12 at the low force) of shoulder motion and the work pulses at the low force were about 70 % of those at the high force. Lastly, the RPEs of the upper extremity regions were about level 3(moderate) or below.

저강도 초음파치료의 골절치유 효과 (Effect of Low-Intensity Ultrasound on Bone Growth)

  • 이충휘;김종만;황태선
    • 한국전문물리치료학회지
    • /
    • 제5권3호
    • /
    • pp.34-41
    • /
    • 1998
  • Noninvasive low intensity ultrasound has been shown to be an effective means of accelerating bone fracture repair in both animal and clinical studies. The effects of ultrasound stimulation on bone repair after fibular osteotomy were assessed in a rabbit fibular fracture model. Bilateral closed fibular fractures were made in skeletally mature male White Japanese rabbits. In this study, 24 subjects were randomly divided into 2 groups: experimental group 1 (n=12), and experimental group 2 (n=12). Experimental group 1 received 0.875 MHz continuous ultrasound and Experimental group 2 was treated with 3 MHz continuous u1trasound. The ultrasound intensity was 50 $mW/cm^2$ and treatment time was 10 minutes for every session in both groups. In each rabbit, one fibula served as a control and the other was subjected to ultrasound treatment 5 times per week for 3 weeks. After 3 weeks, rabbits were sacrificed and the ratios of the area between the trabeculae and bone marrow of the fibulae were calculated. At the end of the experimental period, 14 of the 24 rabbits were excluded due to complications from surgery or inadequate fracture status for this study. There was no statistically significant difference in the trabeculae area between experimental leg and control leg in experimental group 1 and experimental group 2 (p>0.05). And there was also no statistic-statistically significant difference between experimental group 1 and experimental group 2 according to ultrasound treatment frequencies, 0.875 MHz and 3 MHz (p>0.05). These data suggest that in Japanese white rabbits, low intensity ultrasound stimulation does not facilitate fracture repair nor is there any difference in fracture repair results between ultrasound frequencies, 0.875 MHz and 3 MHz.

  • PDF