• Title/Summary/Keyword: low depth of field

Search Result 312, Processing Time 0.03 seconds

Study on 6 MV Photon beam Dosimetry by Asymmetric Collimator Variation of Linear Accelerator (6MV 선형가속기의 비대칭 조사야의 변화에 따른 선량분포)

  • Yoon, Joo-Ho;Lee, Chul-Soo;Yum, Ha-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.12 no.1
    • /
    • pp.91-104
    • /
    • 2000
  • Recently linear accelerator in radiation therapy in asymmetric field has been easily used since the improvement and capability of asymmetrical field adjustment attached to the machine. It has been thought there have been some significant errors in dose calculation when asymmetrical radiation fields have been utilized in practice of radiation treatments if the fundamental data for dose calculation have been measured in symmetrical standard fields. This study investigated how much the measured data of dose distributions and their isodose curves are different between in asymmetrical and symmetrical standard fields, and how much there difference affect the error in dose calculation in conventional method measured in symmetrical standard field. The distributions of radiation dose were measured by photon diode detector in the water phantom (RFA-300P, Scanditronix, Sweden) as tissue equivalent material on utilization of 6 MV linear accelerator with source surface distance (SSD) 1000 mm. The photon diode detector has the velocity of 1 mm per second from water surface to 250 mm depth in the field size of $40mm{\times}40mm\;to\;250mm{\times}250mm\;symmetric\;field\;and\;40mm{\times}20mm\;to\;250mm{\times}125mm$ asymmetrical fields. The measurements of percent depth dose (PDD) and subsequent plotting of their isodose curves were performed from water surface to 250mm dmm from Y-center axis in $100mm{\times}50mm$ field in order to absence the variability of depth dose according to increasing field sizes and their affects to plotted isodose curves. The difference of PDD between symmetric and asymmetric field was maximum $4.1\%\;decrease\;in\;40mm{\times}20mm\;field,\;maximum\;6.6\%\;decrease\;in\;100mm{\times}50mm\;and\;maximum\;10.2\%\;decrease\;200mm{\times}100mm$, the larger decrease difference of PDD as the greater field size and as greater the depth, The difference of PDD between asymmetrical field and equivalent square field showed maximum $2.4\%\;decrease\;in\;60mm{\times}30mm\;field,\;maximum\;4.8\%\;decrease\;in\;150mm{\times}75mm\;and\;maximum\;6.1\%\;decrease\;in\;250mm{\times}125mm$, and the larger decreased differenced PDD as the greater field size and as greater the depth, these differences of PDD were out of $5\%$ of dose calculation as defined by international Commission on radiation unit and Measurements(ICRU). In the dose distribution of asymmetrical field (half beam) the plotted isodose curves were observed to have deviations by decreased PDD as greater as the blocking of the beam moved closer to the central axis, and as the asymmetrical field increased by moving the block 10 mm keeping away from the central axis, the PDD increased and plotted isodose curves were gradually more flattened, due to reduced amount of the primary beam and the fraction of low energy soft radiations by passing thougepth in asymmetrical field by moving independent jaw each 10 h beam flattening filter. As asymmetrical radiation field as half beam radiation technique is used, the radiation dosimetry calculated in utilizing the fundamental data which measured in standard symmetrical field should be converted on bases of nearly measured data in asymmetrical field, measured beam data flies of various asymmetrical field in various energy and be necessary in each institution.

  • PDF

A Case Study on the Plan for Settlement Restraint by CGS (CGS 공법에 의한 지반침하억제 사례연구)

  • 천병식;여유현;김우종;황성식;김우철
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.611-618
    • /
    • 2002
  • In this study the CGS as an injection method by low slump mortar was performed the pilot test to confirm the applicability of this method and the effectiveness of settlement restraint. From the results, there has been concluded the construction control standard such as an institutional diameter, space, depth, injection materials, Infection pressure etc. Also, there has been estimated the ground improvement effectiveness which has resulted from the field investigation and consolidation test etc. From the results, in the adjacent ground the CGS, generally, has been confirmed to in-crease ground strength to improve the consolidation characteristic obtained from the field investigation and consolidation test. Especially, the CGS which performed the larger stiffness to the ground has been concluded that the settlement restraint to the ground complicates the ground effect which Increases the bearing capacity and stress assignment. So, the CGS can be considered as an effective method to increase the bearing capacity as well as the settlement restraint of soft ground.

  • PDF

Multiple Vision Based Micromanipulation System for 3D-Shaped Micro Parts Assembly

  • Lee, Seok-Joo;Park, Gwi-Tae;Kim, Kyunghwan;Kim, Deok-Ho;Park, Jong-Oh
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.103.5-103
    • /
    • 2001
  • This paper presents a visual feedback system that controls a micromanipulator using multiple microscopic vision information. The micromanipulation stations basically have optical microscope. However the single field-of-view of optical microscope essentially limits the workspace of the micromanipulator and low dept-of-field makes it difficult to handle 3D-shaped micro objects. The system consists of a stereoscopic microscope, three CCD cameras, the micromanipulator and personal computer. The use of stereoscopic microscope which has long working distance and high depth-of-field with selective field-of-view improves the recognizability of 3D-shaped micro objects and provides a method for overcoming several essential limitations in micromanipulation. Thus, visual feedback information is very important in handling micro objects for overcoming those limitations and provides a mean for the ...

  • PDF

Study on the Management of Minimum Low Flow and Water Quality of Hongjechun (홍제천 정비를 위한 하천유지유량 확보 및 수질개선 방안 연구)

  • Hwang, Byung-Gi;Ho, Jong-Kwang;Oh, Kyung-Seok
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.1
    • /
    • pp.37-46
    • /
    • 2005
  • In this study, field surveys were performed for 12 stations in main stream of Hongjechun and 3 stations in 2 tributaries, respectively, in order to find out dried reaches of the stream, and to examine the water quality of the stream, and to suggest methods to improve the stream concerned into eco-stream. In the results of water quality in stream, however distinct difference for seasonal variation of the water quality was not found, the water quality of winter was relatively better than that of other seasons. Annual mean concentration of BOD was 6.5mg/L in the upper reach, 11.8mg/L in the middle reach, 15.3mg/L in the lower reach of main stream, and total mean was 12.5mg/L, while the BOD concentration was 3.6mg/L in the upper reach, and was 9.6mg/L in the low reach of Gukichun, the tributary. Based on flow examination, the level of water depth was so low and the flow can not be traveled downstream in the reach between ST-9 and ST-10 for low water season, whereas it was observed that the flow was traveling except the dry season even the water level was lower than that of adjacent stations.

Optical Properties Correction of a Heterogeneous Stereoscopic Camera (이종 입체 영상 카메라의 광학 특성 일치화)

  • Jung, Eun Kyung;Baek, Seung-Hae;Park, Soon-Yong;Jang, Ho-Wook
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.11
    • /
    • pp.74-85
    • /
    • 2012
  • In this paper, we propose a optical property correction technique for a low-cost heterogeneous stereoscopic camera. Three main optical properties of a stereoscopic camera are zoom, focus, and DOF(depth of field). The difference or mis-match of these properties between two stereoscopic videos are the main causes of the visual fatigue to human eyes. The proposed correction technique reduces the difference of the optical properties between the stereoscopic videos and produces high-quality stereoscopic videos. To correct the zoom difference, a LUT(look-up table) is established to match the zoom ratio between the stereoscopic videos. To correct the DOF difference, the magnitude of image edge is measured and the lens iris is changed to control the DOF of the camera. A vertical-type stereoscopic rig is developed for the experiments of the optical property correction. Based on the experimental results, we find that a low-cost heterogeneous stereoscopic camera can be implemented, which can yield low visual fatigue to human eyes.

A Revised Dynamic ROI Coding Method Based On The Automatic ROI Extraction For Low Depth-of-Field JPEG2000 Images (낮은 피사계 심도 JPEG2000 이미지를 위한 자동 관심영역 추출기반의 개선된 동적 관심영역 코딩 방법)

  • Park, Jae-Heung;Kim, Hyun-Joo;Shim, Jong-Chae;Yoo, Chang-Yeul;Seo, Yeong-Geon;Kang, Ki-Jun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.10
    • /
    • pp.63-71
    • /
    • 2009
  • In this study, we propose a revised dynamic ROI (Region-of-Interest) coding method in which the focused ROI is automatically extracted without help from users during the recovery process of low DOF (Depth-of-Field) JPEG2000 image. The proposed method creates edge mask information using high frequency sub-band data on a specific level in DWT (Discrete Wavelet Transform), and then identifies the edge code block for a high-speed ROI extraction. The algorithm scans the edge mask data in four directions by the unit of code block and identifies the edge code block simply and fastly using a edge threshold. As the results of experimentation applying for Implicit method, the proposed method showed the superiority in the side of speed and quality comparing to the existing methods.

Risk Assessment of Cut Slope by Gravity Field Interpretation and Modelling (비탈면 위험도 평가를 위한 중력장 해석 및 모델링)

  • Choi, Sungchan;Kim, Sung-Wook;Choi, Eun-Kyoung;Lee, Yeong-Jae;Jang, Hyun-Ick
    • The Journal of Engineering Geology
    • /
    • v.31 no.4
    • /
    • pp.533-540
    • /
    • 2021
  • Gravity field analysis and density modeling were performed to evaluate the internal state of the rock mass, which is the cause of cut slope collapse. The shape of the weathered zone and the depth of basement could be confirmed from the complete Bouguer anomaly and density model. The basement depth at the center of the cut slope calculated using the Euler deconvolution inverse method is 30 m, which is about 10 m deeper than the surrounding area. In addition, the depth of basement and the thickness of the weathered zone are similar to the boundary between low resistivity and high resistivity in dipole-dipole survey. From the study results, gravity field analysis and density modeling recognizes the internal state of the rock slope and can be used for slope safety analysis, and is particularly suitable as a method to determine the shape of weathered zones in interpreting the safety of cut slopes

Preference and perception of low-sodium burger

  • Choi, Seung-Gyun;Yim, Sun-Goo;Nam, Sang-Myung;Hong, Wan-Soo
    • Nutrition Research and Practice
    • /
    • v.16 no.1
    • /
    • pp.132-146
    • /
    • 2022
  • BACKGROUND/OBJECTIVES: Various sodium reduction policies have been implemented. However, there are limitations in the aspect of actual field applicability and efficiency. For effective sodium reduction, cooperation with the field is required and consumer preference must be considered. Thus, this study aimed to develop a low-sodium burger considering field applicability and consumer preference. MATERIALS/METHODS: Focus group interviews and in-depth interviews on the sodium reduction measures were conducted with nine professionals in related fields to discuss practical methods for sodium reduction from September 7 to 21, 2018. By reflecting the interview results, a burger using a low-sodium sauce was developed, and preference analysis for sodium in the burger sauces and finished products was performed. The consumer preference for low-sodium burgers was evaluated on 51 college students on November 12, 2018. RESULTS: The results of the professional interview showed that it is desirable to practice sodium reduction gradually, and by reflecting this, the burger sauce was prepared by adjusting the ratio of refined salt to 15%, 30%, and 50%. The sodium content of the burger using low-sodium sauce was 399 mg/100 g in the control group, 362 mg/100 g in the H1 group, and 351.5 mg/100 g in the H2 group, showing a 9.3-11.9% decrease in sodium in the H1 and H2 groups. The preference evaluation on the low-sodium burgers showed a higher preference for burgers with 9.3-11.9% sodium reduction, which did not affect the overall taste. CONCLUSIONS: This study examined the potential for sodium reduction in the franchise foodservice industry. An approximate 10% sodium reduction resulted in an increase in consumer preference without affecting the strength of the taste. Thus, if applied gradually, sodium reduction at practical levels could increase the consumer preference without changing the taste or quality and could be applied in the franchise foodservice industry.

A study on the noise reduction of practical duct system with the air cavity (공기층을 갖는 실제덕트 구조물에서의 소음저감에 관한 연구)

  • Kim, Chan-Mook;Lee, Doo-Ho;Bahng, Keuk-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1687-1692
    • /
    • 2000
  • In this paper, experimental methods to find acoustic characteristics of acoustically treated air-conditioning duct system are proposed. Existing methods to analyze acoustic properties of duct with absorbent material have a dilemma which has to assume the wave in duct to be a plane wave. Under this assumption, applicable frequency limitation makes accurate analysis of practical air-conditioning system impossible. In order to analyze the properties of in-lined treated absorbent with high degree of accuracy, in this experiments the range of exciting frequency of sound source is broadband, which means that source speaker excites higher mode of in-duct sound field. Also, to define the relations of air cavity to the acoustic characteristics, acoustic experiments on ducts with air cavity of different depth are operated. In conclusion, air-cavity makes the absorbing ability of duct improved in low frequency range. Due to the interactions between the air cavity depth and the depth of absorbents, according to depth of cavity, the magnitude of absorption coefficients vs frequencies in specific range is changed. In lower frequency range, the absorption of sound energy by air cavity is more dominant than by absorbent itself, in higher range, the inversion is true.

  • PDF

A Study on the Absorption Characteristics of Absorbents in Duct System with the Air Cavity (공기층을 갖는 공조덕트 구조물에서 흡음재의 흡음특성에 관한 연구)

  • 김찬묵;김도연;방극호
    • Journal of KSNVE
    • /
    • v.10 no.5
    • /
    • pp.892-897
    • /
    • 2000
  • In this paper, experimental methods to find acoustic characteristics of acoustically treated air-conditioning duct system are proposed. Existing methods to analyze acoustic properties of duct with absorbent material have dilemma which has to assume the wave in duct to be a plane wave. Under this assumption. applicable frequency limitation makes accurate analysis of practical air-conditioning system impossible. In order to analyze the properties of in-lined treated absorbent with high degree of accuracy, in this experiments the range of exciting frequency of sound source is broadband, which means that source speaker excited higher mode of in-duct sound field. Also, to define the relations of air cavity to the acoustic characteristics, acoustic experiments on ducts with air cavity of different depth are operated. In conclusion, air-cavity makes the absorbing ability of duct improved in low frequency range. Due to the interactions between the air cavity depth and the depth of absorbents, according to depth of cavity, the magnitude of absorption coefficients vs frequencies in specific range is changed. In lower frequency range, the absorption of sound energy by air cavity is more dominant than by absorbent itself, in higher range, the inversion is true.

  • PDF