• Title/Summary/Keyword: low conductivity

Search Result 1,713, Processing Time 0.026 seconds

Susceptibility of Two Potato Cultivars to Various Environmental Stresses (다양한 환경스트레스에 대한 감자 2품종의 감수성 분석)

  • Tang, Li;Kwon, Suk-Yoon;Sung, Chang-K;Kwak, Sang-Soo;Lee, Haeng-Soon
    • Journal of Plant Biotechnology
    • /
    • v.30 no.4
    • /
    • pp.405-410
    • /
    • 2003
  • Environmental stress is the major limiting factor in plant productivity. In order to evaluate the stress tolerance of potato plants, leaf discs of two potato cultivars, Atlantic and Superior, were subjected to various stress conditions of high temperature, methyl viologen, H2O2, or $H_2O$$_2$. When potato leaf discs were exposed to high temperature at 37$^{\circ}C$ for 84 hr, Atlantic plants, a cultivar with high sensitivity to heat stress, showed about 20% higher membrane damage than Superior plants. When exposed to 2$\mu$M methyl violgen (MV), a superoxide generating non-selective herbicide, for 36 hr, Atlantic plants also showed about 38% higher membrane damage than Superior plants, and were more susceptible up to 10$\mu$M MV concentration tested. On treatment with 0.75M NaCl, Atlantic plants also had about 45% less chlorophyll contents in leaf discs than Superior plants. There was, however, no difference in chlorophyll content of two cultivars at higher NaCl concentrations. The effect of $H_2O$$_2$ on the two cultivars was mixed. At low $H_2O$$_2$ concentration (25 mM) , Superior plants were more susceptible to $H_2O$$_2$stress after 36 hr. However, at high $H_2O$$_2$ concentration (100 mM), Atlantic plants exhibited higher susceptibility after 36 hr. The results indicate that in vitro leaf discs reflecting the whole plants in this study will be useful for selection and characterization of elite transgenic potato plants with enhanced tolerance to environmental stress.

Water Quality and Hydrochemistry of Natural Springs and Community Wells in Daejeon Area (대전지역 자연샘물 및 공동우물의 수질 및 수리화학적 특성)

  • 정찬호;박충화;이광식
    • Economic and Environmental Geology
    • /
    • v.35 no.5
    • /
    • pp.395-406
    • /
    • 2002
  • The sixty natural springs and community wells used as a drinking water in the Daejeon area are mainly located at the parks and the natural green districts. The purpose of this study is to investigate the characteristics of water quality and the contamination of the springs and the wells, and to suggest the management strategy for the springs and wells. For this study, we undertook water quality data from Daejeon City. According to the statistic analysis of water quality data, unacceptable rate as a drinking water was about 28 percent in 1999 and 24.5 percent in 2000, respectively. Major unacceptable factor is coliform, and others are bacteria, yersinia, color, turbidity, Fe and F. The unacceptable rate shows a roughly positive relationship with precipitation, that is, it shows highest rate during a rainy season between June and September. The major contamination source is likely to be the excrement of wild animals around natural springs and wells. Most of springs are vulnerable to the contamination of coliform and bacteria because of short residence time and shallow circulation in subsurface environment. The water samples collected from 31 springs or wells show weak acidic pHs, the electrical conductivity ranging from 63 to 357 $\mu\textrm{S}$/cm, and the hydrochemical types of Na(Ca)-HC0$_3$ and Ca-HC0$_3$. The groundwater samples of low total dissolved solid(TDS) belong to Na(Ca)-HC0$_3$. type, and the groundwater of high total dissolved solid is shifted towards Ca-HC0$_3$ type in the chemical composition. These hydrochemical characteristics indicate that most natural springs is in the early stage of geochemical evolution. The natural springs should be closed during a rainy season, which shows a high contamination rate. We suggest that a protection barrier around the springs should be built to keep wild animals away from the springs.

Groundwater and Soil Environment of Plastic Film House Fields around Central Part of Korea (우리나라 중부지방의 시설원예 토양 및 지하수 환경)

  • Kim, Jin-Ho;Lee, Jong-Sik;Kim, Won-Il;Jung, Goo-Bok;Yun, Sun-Gang;Jung, Yeun-Tae;Kwun, Soon-Kuk
    • Korean Journal of Environmental Agriculture
    • /
    • v.21 no.2
    • /
    • pp.109-116
    • /
    • 2002
  • The objective of this study was to know the qualities of soil and shallow groundwater in plastic film house fields around Central Part of Korea. The study was conducted at 11 sites in Suweon, Hwasung, Pyungtaek, Yongin and Chuncheon through May to August in 1999. Soil textures of plastic films house were mainly sandy loam or loam. Electric conductivity and organic matter content of surface soils mostly exceeded the critical levels for crop production. Average concentration of $NO_3-N$ in the sha]low groundwater was 19.1 mg/L, and it reached almost the limiting level of agricultural groundwater quality (20 mg/L). Moreover about 36% of survey sites exceeded the limiting level of agricultural groundwater quality. Sulfate concentrations also at some sites exceeded agricultural groundwater quality limit level (50 mg/L). Nitrate-N, one of the most important factors in the groundwater quality, had positive correlations with other ions in foundwater.

Soil Salinity and Vegetation Distribution at Four Tidal Reclamation Project Areas (4개 간척 지구에 분포하는 식생과 토양 염류농도)

  • Lee, Seung-Heon;Ji, Kwang-Jae;An, Yeoul;Ro, Hee-Myong
    • Korean Journal of Environmental Agriculture
    • /
    • v.22 no.2
    • /
    • pp.79-86
    • /
    • 2003
  • This research was conducted to present reference data to be used as newly reclaimed tidal land management. We investigated vegetation succession at 4 reclaimed/reclaiming project areas and discussed relationship with soil and vegetation trhrough investigation and analysis soil chemical characteristics at 2 areas. 14 families 58 kinds were investigated. Vegetation were variou at Dea-Ho conservation polt and Seok-Mun National Industrial Area which are maintaining naturally. Vegetation were simple at Hong-Bo and Dongjin and MinKyong river areas which effected sea water. Common species that were investigated at 9 sites were Suaeda asparagoides, Aster tripolium, Phragmites australis, Suaeda maritima, Suaeda japonica, Carex scabrifolis. As soil desalinization progressing, soil classified at first saline-soidc soil, the nest saline soil and then normal soil. Chenopodiaceae revealed at about 30 dS/m of soil ECe and existed to 10 dS/m of soil ECe. At about 20 dS/m of soil ECe. Aster tripolium, Calamagrostis epigeios, and Sonchus brachyotus revealed and then non-halophytes and common plants at inland revealed at low soil ECe of about 10 dS/m. However it was not to progress vegetation sucdession and soil desalinization at the same time, owing to input of seeds or plants ect from out-ecosystem. So for promotion of vegetation at newly reclaimed tidal land, we proposed that it was very effective to plant artificially halophytes or suitable species through soil test.

Physico-chemical Characteristics and In situ Fish Enclosure Bioassays on Wastewater Outflow in Abandoned Mine Watershed (폐광산 지역의 유출수에 대한 이.화학적 수질특성 및 Enclosure 어류 노출시험 평가)

  • An, Kwang-Guk;Bae, Dae-Yeul;Han, Jeong-Ho
    • Korean Journal of Ecology and Environment
    • /
    • v.45 no.2
    • /
    • pp.218-231
    • /
    • 2012
  • The objectives of this study were to evaluate the physico-chemical water quality, trophic and tolerance guilds in the control ($C_o$) and impacted streams of the abandoned mine, along with the ecological health, using a multimetric health model and physical habitat conditions of Qualitative Habitat Evaluation Index (QHEI), during the period of three years, 2005~2007. Also, eco-toxicity ($EE_t$) enclosure tests were conducted to examine the toxic effects on the outflows from the mine wastewater, using the sentinel species of Rhynchocypris oxycephalus, and we compared the biological responses of the control ($C_o$) and treatment (T) to the effluents through a Necropybased Health Assessment Index ($N_b$-HAI). Tissue impact analysis of the spleen, kidney, gill, liver, eyes, and fins were conducted in the controlled enclosure experiments (10 individuals). According to the comparisons of the control ($C_o$) vs. the treatment (T) in physicochemical water quality, outflows from the abandoned mine resulted in low pH of 3.2, strong acid wastewater, high ionic concentrations, based on an electrical conductivity, and high total dissolved solid (TDS). Physical habitat assessments, based on Qualitative Habitat Evaluation Index (QHEI) did not show any statistical differences (p>0.05) in the sampling sites, whereas, the $M_m$-EH model values in a multimetric ecological health ($M_m$-EH) model of the Index of Biological Integrity (IBI), using fish assemblages, were 16~20 (fair condition) in the control and all zero (0, poor condition) in the impacted sites of mine wastewater. In addition, in enclosure eco-toxicity ($EE_t$) tests, the model values of $N_b$-HAI ranged between 0 and 3 in the controls during the three years, indicating an excellent~good condition (Ex~G), and were >100 (range: 100~137) in the impacted sites, which indicates a poor condition (P). Under the circumstances, organ tissues, such as the liver, kidney, and gills were largely impaired, so that efficient water quality managements are required in the outflow area of the abandoned mine watershed.

Interannual and Seasonal Variations of Water Quality in Terms of Size Dimension on Multi-Purpose Korean Dam Reservoirs Along with the Characteristics of Longitudinal Gradients (우리나라 다목적댐 인공호들의 규모에 따른 연별.계절별 수질변이 및 상.하류간 종적구배 특성)

  • Han, Jeong-Ho;Lee, Ji-Yeoun;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.43 no.2
    • /
    • pp.319-337
    • /
    • 2010
  • Major objective of this study was to determine interannual and seasonal water quality along with characteristics of longitudinal gradients along the reservoir axis of the riverine zone (Rz)-to-lacustrine zone (Lz). Water quality dataset of five years during 2003~2007 used here were obtained from Ministry of Environment, Korea and ten physical, chemical and biological parameters were analyzed in the study. Similarity analysis, based on moropho-hydrological variables of reservoir surface area, watershed area, total inflow, and outflow, showed that the reservoirs were categorized as three groups of large-dam reservoirs (Chungju Reservoir, Daecheong Reservoir and Soyang Reservoir), mid-size reservoirs (Andong Reservoir, Yongdam Reservoir, Juam Reservoir and Hapcheon Reservoir), and small-size reservoirs (Hoengseong Reservoir and Buan Reservoir). According to the data comparison of high-flow year (2003) vs. lowflow year (2005), dissolved oxygen (DO), pH, biological oxygen demand (BOD), suspended solids (SS), total nitrogen (TN), total phosphorus (TP), chlorophyll-a (CHL) and electrical conductivity (EC) declined along the longitudinal axis of Rz to Lz and water transparency, based on Secchi depth (SD), increased along the axis. These results indicate that transparency was a function of Values of pH, DO, SS, SD, and EC at each site were greater in the low-flow year (2005) than the high-flow year (2003), whereas values of BOD, COD, TN, TP and CHL were greater in the high-flow year (2003). When values of TN, TP, CHL and SD in nine reservoirs were compared in the three zones of Rz, Tz, and Lz, values of TN, TP and CHL declined along longitudinal gradients and SD showed the opposite due to the sedimentation processes from the water column. Values of TN were not statistically correlated with TP values. The empirical linear models of TP-CHL and CHL-SD showed significant (p<0.05, $R^2$>0.04). In the mid-size reservoirs, the variation of CHL was explained ($R^2$=0.2401, p<0.0001, n=239) by the variation of TP. The affinities in the correlation analysis of mid-size reservoirs were greater in the CHL-SD model than any other empirical models, and the CHL-SD model had an inverse relations. In the meantime, water quality variations was evidently greater in Daecheong Reservoir than two reservoirs of Andong Reservoir and Hoengseong Reservoir as a result of large differences of water quality by long distance among Rz, Tz and Lz.

Relationship between Rainfall and Zooplankton Community Dynamics in a Riverine Wetland Ecosystem (Upo) (강 배후 습지생태계(우포)에서 강우량과 동물플랑크톤 군집 동태)

  • Kim, Hyun-Woo;Choi, Jong-Yun;La, Geung-Hwan;Jeong, Kwang-Seuk;Jo, Gea-Jae
    • Korean Journal of Ecology and Environment
    • /
    • v.43 no.1
    • /
    • pp.129-135
    • /
    • 2010
  • The relationship between rainfall variable and zooplankton dynamics was studied in the Upo wetland, an ecosystem of international importance. Water sampling was conducted on biweekly basis from January 2002 to December 2007 in the study site. The annual average of total rainfall was 1,324 mm during the study period. Total rainfall amount in 2003 (1,766 mm) was unusually high, while total rainfall amount in 2005 (975 mm) was exceptionally lower than the average. Most of basic limnological parameters (water temperature, dissolved oxygen, pH, conductivity and turbidity) in the study site were greatly influenced by the flooding events and rainfall amounts in summer. There were statistically significance between seasonal and inter-annual differences in zooplankton abundance and the total rainfall amount (ANOVA, P<0.05). Zooplankton abundance was high in summer (mean${\pm}$s.d.: $1,594{\pm}1,598\;Ind.\;L^{-1}$) and low in winter ($246{\pm}234\;Ind.\;L^{-1}$. The 47% of annual total zooplankton abundance in the study site were observed in summer. The seasonal pattern of rotifers was similar to that of total zooplankton. This reflected the fact that rotifers strongly dominated and occupied ca. 65% the total zooplankton abundance (annual mean: $398{\pm}1,139\;Ind.\;L^{-1}$, n=149), followed by cladocerans ($65{\pm}140\;Ind.\;L^{-1}$) and copepods ($58{\pm}84\;L^{-1}$). Planktonic rotifers such as Keratella cochlearis, Polyarthra spp. and Brachionus calyciflorus were dominant from winter to spring and attached rotifers such as Lecane spp., Monostyla spp. and Trichocerca spp., observed commonly from spring to fall. Among the environmental variables considered, rainfall in summer seemed to play the most important role in determining characteristics of zooplankton community dynamics in the Upo wetland.

The development of conductive 10B thin film for neutron monitoring (중성자 모니터링을 위한 전도성 10B 박막 개발)

  • Lim, Chang Hwy;Kim, Jongyul;Lee, Suhyun;Jung, Yongju;Choi, Young-Hyun;Baek, Cheol-Ha;Moon, Myung-Kook
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.199-205
    • /
    • 2014
  • In the field of neutron detections, $^3He$ gas, the so-called "the gold standard," is the most widely used material for neutron detections because of its high efficiency in neutron capturing. However, from variable causes since early 2009, $^3He$ is being depleted, which has maintained an upward pressure on its cost. For this reason, the demands for $^3He$ replacements are rising sharply. Research into neutron converting materials, which has not been used well due to a neutron detection efficiency lower than the efficiency of $^3He$, although it can be chosen for use in a neutron detector, has been highlighted again. $^{10}B$, which is one of the $^3He$ replacements, such as $BF_3$, $^6Li$, $^{10}B$, $Gd_2O_2S$, is being researched by various detector development groups owing to a number of advantages such as easy gamma-ray discrimination, non-toxicity, low cost, etc. One of the possible techniques for the detection is an indirect neutron detection method measuring secondary radiation generated by interactions between neutrons and $^{10}B$. Because of the mean free path of alpha particle from interactions that are very short in a solid material, the thickness of $^{10}B$ should be thin. Therefore, to increase the neutron detection efficiency, it is important to make a $^{10}B$ thin film. In this study, we fabricated a $^{10}B$ thin film that is about 60 um in thickness for neutron detection using well-known technology for the manufacturing of a thin electrode for use in lithium ion batteries. In addition, by performing simple physical tests on the conductivity, dispersion, adhesion, and flexibility, we confirmed that the physical characteristics of the fabricated $^{10}B$ thin film are good. Using the fabricated $^{10}B$ thin film, we made a proportional counter for neutron monitoring and measured the neutron pulse height spectrum at a neutron facility at KAERI. Furthermore, we calculated using the Monte Carlo simulation the change of neutron detection efficiency according to the number of thin film layers. In conclusion, we suggest a fabrication method of a $^{10}B$ thin film using the technology used in making a thin electrode of lithium ion batteries and made the $^{10}B$ thin film for neutron detection using suggested method.

Effect of Coolant on PEMFC Performance in Low Humidification Condition (저가습 조건에서 냉각 유체의 고분자전해질 연료전지에 대한 영향)

  • Lee, Hung-Joo;Song, Hyun-Do;Kwon, Jun-Taek;Kim, Jun-Bom
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.1
    • /
    • pp.25-30
    • /
    • 2007
  • Proton exchange membrane fuel cell(PEMFC) performance could be affected by various factors such as cell temperature, total pressure, partial pressure of reactants and relative humidity. Hydrogen ion is combined with water to form hydronium ion [$H_3O^+$] and pass through membrane resulting electricity generation. Cooling system is needed to remove heat and other uses on large scale fuel cell. In case that collant conductivity is increased, fuel cell performance could be decreased because produced electricity could be leaked through coolant. In this study, triple distilled water(TDW) and antifreeze solution containing ethylene glycol was used to observe resistance change. Resistance of TDW was taken 28 days to reach preset value, and effect on fuel cell operation was not observed. Resistance of antifreeze solution was not reached to preset value up to 48 days, but performance failure occurred presumably caused by bipolar plate junction resulting stoppage resistance experiment. Generally PEMFC humidification is performed near-saturated operating conditions at various temperatures and pressures, but non-humidifying condition could be applied in small scale fuel cell to improve efficiency and reduce system cost. However, it was difficult to operate large scale fuel cell without humidifying, especially higher than $50{\sim}60^{\circ}C$. In case of small flux such as 0.78 L/min, temperature difference between inlet and outlet was occurred larger than other cases resulting performance decrease. Non-humidifying performance experiments were done at various cell temperature. When both of anode and cathode humidification were removed, cell performance was strongly depended on cell operating temperature.

Effects of Sodium and Gallium on Characteristics of CIGS Thin Films and CdS/CIGS Solar Cells by Co-evaporation Method (Na확산과 Ga첨가에 따른 동시진공증발법으로 제조된 CIGS 박막과 CdS/CIGS 태양전지의 특성)

  • Kwon, S.H.;Lee, J.C.;Kang, K.H.;Kim, S.K.;Yoon, K.H.;Song, J.S.;Lee, D.Y.;Ahn, B.T.
    • Solar Energy
    • /
    • v.20 no.2
    • /
    • pp.43-54
    • /
    • 2000
  • We prepared and characterized $Cu(In_{1-x}Ga_x)Se_2$(CIGS) films using a elemental co-evaporation method for absorbing layer of high efficiency thin film solar cells. The CIGS films deposited on a soda-lime glass exhibited low resistivity because of higher carrier concentration. Na was accumulated at the CIGS surface and the 0 and Se were also accumulated at the surface, suggesting that oxidation is a driving force of Na accumulation. The structure of CIGS film was modified or a secondary phase was formed in the Cu-poor CIGS bulk films probably due to the incorporation of Na into Cu vacancy sites. As the Ga/(In+Ga) ratio increased, the diffraction peaks of $Cu(In_{1-x}Ga_x)Se_2$ films were shifted to larger angle and splitted, and the grain size of $Cu_{0.91}(In_{1-x}Ga_x)Se_2$ films became smaller. All $Cu_{0.91}(In_{1-x}Ga_x)Se_2$ films showed the p-type conductivity regardless of the Ga/(In+Ga) ratio. Ag/n-ZnO/i-ZnO/CdS/$Cu_{0.91}(In_{0.7}Ga_{0.3})Se_2$/Mo solar cells were fabricated. The currently best efficiency in this study was 14.48% for $0.18cm^2$ area ($V_{oc}=581.5mV,\;J_{sc}=34.88mA$, F.F=0.714).

  • PDF