• 제목/요약/키워드: low cement concrete

검색결과 623건 처리시간 0.026초

고강도 콘크리트의 염화물 침투특성 (Chloride Permeability of High Strength Concrete)

  • 정해문;유환구;안태송
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.985-990
    • /
    • 2001
  • Chloride permeability of high strength concrete(HSC) was investigated using saltwater pending test and rapid chloride permeability test by electrical potential(ASTM C 1202). The lower water-cement ratio concrete showed the lower diffusion coefficient of chloride. The relationship between the diffusion coefficient of chloride and charge passed by the rapid chloride permeability test could be obtained. This relationship appears to be an effective method for evaluating chloride permeability of low water-cement HSC.

  • PDF

시멘트와 메타카올린 혼합물의 미세구조 관찰 (Microstructural Observation of Cement and Metakaolin Mixture)

  • 공경록;정현석;강헌찬
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.449-452
    • /
    • 2006
  • This study inhence the strength of concrete by using domestic low grade kaolin. In conclusion, we confirmed to inhence the strength of concrete when added the low grade kaolin(heated in $800^{\circ}C$) about 10%.

  • PDF

양생온도가 플라이애시를 사용한 콘크리트의 초기강도발현에 미치는 영향 (Effect of Curing Temperature on Early Age Strength Development of the Concrete Using Fly Ash)

  • 한민철;신병철
    • 한국환경과학회지
    • /
    • 제19권1호
    • /
    • pp.105-114
    • /
    • 2010
  • The objective of the paper is to experimentally investigate the compressive strength of the concrete incorporating fly ash. Ordinary Portland cement(OPC). Water to binder ratio(W/B) ranging from 30% to 60% and curing temperature ranging from $-10^{\circ}{\sim}65^{\circ}C$ were also adopted for experimental parameters. Fly ash was replaced by 30% of cement contents. According to the results, strength development of concrete contained with fly ash is lower than that of plain concrete in low temperature at early age and maturity. In high curing temperature, the concrete with fly ash has higher strength development than that of low temperature regardless of the elapse of age and maturity. Fly ash can have much effect on the strength development of concrete at the condition of mass concrete, hot weather concreting and the concrete products for the steam curing.

콘크리트 용도별 최적배합을 위한 연구(II) (Optimum Mix Design of Concrete(II))

  • 심재원;이병덕;양우석;안태송
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.175-178
    • /
    • 1999
  • In most domestic construction fields, excessive cement content has been used because of stubborn official inspection. The purpose of this study is to reduce the cement content of mix proportioning for the decrease of hydration heat, brittleness and drying shrinkage which governs durability of concrete significantly. Parameters includes the compressive strengths, type and dosage rate of chemical and mineral admixtures and types of concrete. It is found that the chemical admixture is efficient to the reduction of cement content for high strength concrete (400kg/$\textrm{cm}^2$) and the effectiveness of mineral admixtures in the low strength concrete is somewhat higher than the high strength concrete.

  • PDF

조강시멘트를 이용한 한중콘크리트의 특성평가 연구 (A Study on the Cold Weather Concrete using High Early Strength Concrete)

  • 임채용;엄태선;유재상;이종열;이순기;이동호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.261-264
    • /
    • 2003
  • Cold weather can lead to many problems in mixing, placing, setting time, and curing of concrete that can have harmful effects on its properties and service life. Korean Concrete Institute (KCI) defines cold weather as a period when the average daily air temperature is less $4^{\circ}C$ and recommends to cast concrete with special care such as shielding, heating and so on. The use of high early strength cements may improve the rate of hardening characteristics of concrete in cold weather by making it possible to achieve faster setting time and evolving more hydration heat than ordinary Portland cement. Higher early strength can be achieved using Type III cement especially during the first 7 days. The strength increase property of Type III cement at low temperature was studied. As a conclusion the heat or heat insulation curing period can be reduced to 50~75%. So, it can be used for cold weather concreting to reduce construction cost and extend the construction season.

  • PDF

순환골재의 부착 모르타르량이 콘크리트의 특성에 미치는 영향 (Effect of the Amount of Attached Mortar of Recycled Aggregates on the Properties of Concrete)

  • 이원기;최종오;정용욱
    • 한국건설순환자원학회논문집
    • /
    • 제3권2호
    • /
    • pp.132-139
    • /
    • 2015
  • 본 연구는 파쇄처리 순환골재를 사용한 콘크리트의 특성을 검토하기 위하여 순환골재의 흡수율별 단위시멘트량 및 물시멘트비를 변화시켜 콘크리트의 특성에 미치는 영향을 검토하였다. 실험결과 물시멘트비가 높은 저강도 배합에서는 파쇄처리 순환골재를 사용한 콘크리트와 쇄석 콘크리트의 압축강도가 동등한 수준으로 나타나 순환골재의 부착모르타르 영향이 작은 것으로 나타났다. 그러나, 물시멘트비가 낮은 고강도 배합에서는 파쇄처리 순환골재를 사용한 콘크리트가 부착모르타르의 영향으로 쇄석을 사용한 콘크리트보다 약 40%의 압축강도저하를 나타내었다. 한편, 흡수율 7%인 순환골재의 건조수축량은 재령 10주에서 흡수율 1%인 쇄석의 $-310{\times}10^{-6}$보다 2배 증가된 $-700{\times}10^{-6}$을 나타내어 콘크리트용 골재로의 재활용시 건조수축에 대한 검토가 선행되어야 할 것으로 사료된다. 또한 단위시멘트량 $450kg/m^3$인 부배합 콘크리트의 압축강도는 흡수율 3%인 순환골재 사용시 쇄석 사용 콘크리트와 동등하게 나타난 반면, 흡수율 7%인 순환골재를 사용한 경우에는 쇄석 사용 콘크리트에 비해 약 7%정도 낮게 나타났다. 그러나, 단위시멘트량 $350kg/m^3$인 일반배합 콘크리트의 압축강도는 쇄석 사용 콘크리트에 비해 압축강도 저하가 현저하게 나타났다.

Image Analysis and DC Conductivity Measurement for the Evaluation of Carbon Nanotube Distribution in Cement Matrix

  • Nam, I.W.;Lee, H.K.
    • International Journal of Concrete Structures and Materials
    • /
    • 제9권4호
    • /
    • pp.427-438
    • /
    • 2015
  • The present work proposes a new image analysis method for the evaluation of the multi-walled carbon nanotube (MWNT) distribution in a cement matrix. In this method, white cement was used instead of ordinary Portland cement with MWNT in an effort to differentiate MWNT from the cement matrix. In addition, MWNT-embedded cement composites were fabricated under different flows of fresh composite mixtures, incorporating a constant MWNT content (0.6 wt%) to verify correlation between the MWNT distribution and flow. The image analysis demonstrated that the MWNT distribution was significantly enhanced in the composites fabricated under a low flow condition, and DC conductivity results revealed the dramatic increase in the conductivity of the composites fabricated under the same condition, which supported the image analysis results. The composites were also prepared under the low flow condition (114 mm < flow < 126 mm), incorporating various MWNT contents. The image analysis of the composites revealed an increase in the planar occupation ratio of MWNT, and DC conductivity results exhibited dramatic increase in the conductivity (percolation phenomena) as the MWNT content increased. The image analysis and DC conductivity results indicated that fabrication of the composites under the low flow condition was an effective way to enhance the MWNT distribution.

저발열 결합재 및 W/B 변화에 따른 저열콘크리트의 공학적 특성 (Engineering properties of low heat concrete depending On low heat binder and the change in W/B)

  • 곽용진;손호정;김경민;박상준;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.69-70
    • /
    • 2012
  • This paper is to investigate the engineering properties of the concrete incorporating different types of low heat generating binders subjected to various W/B. As expected, it is found that increase of W/B resulted in a decrease of hydration heat and compressive strength. It also showed that the application of high early strength and low carbon type mixture had favorable strength development at early and later age, while hydration heat showed rather higher than existing low heat mixture.

  • PDF

스폴링이 발생한 콘크리트 포장의 내구성 영향인자 조사를 위한 실험적 연구 (Experimental Study to Investigate the Factors Affecting Durability of Spalled Cement Concrete Pavements)

  • 유태석;류성우;김진철
    • 한국도로학회논문집
    • /
    • 제20권2호
    • /
    • pp.27-34
    • /
    • 2018
  • PURPOSES : It is necessary to prevent premature failure of concrete pavements caused by durability problems. The purpose of this study was to find factors affecting the durability of concrete pavements, and suggest improvement methods for existing concrete mix design. METHODS : Factors influencing durability were derived from laboratory test data for common field failure conditions and main properties of concrete cores taken from the field. The improvement of concrete properties was investigated by evaluating the performance of existing and proposed mix proportion designs and curing methods. RESULTS : The compressive strength and the absorbing performance of the low Blaine cement and the high-strength mixture were better than those of the Type I cement. Wet curing showed better compressive strength, elastic modulus, coefficient of thermal expansion, and absorption performance than air curing or compound curing. As a result of comparing concrete cores collected in the field, the sections with good durability showed good performance in terms of resistance to chloride ion penetration, absorption, and initial absorption rate. CONCLUSIONS : The absorption performance was considered as a possible foactor affecting durability of cement concrete pavements as a result of field core tests. In order to improve the durability of the pavement concrete, it is necessary to improve the existing mixtures and curing methods.

고로슬래그를 혼화재로 혼입한 투수콘크리트의 물리적 특성에 과한 실험적 연구 (An Experimental Study on the Physical Properties of Porous Cement Concrete Using Blast-furnace Slag as an Admixture)

  • 심종우;채창우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.144-149
    • /
    • 2000
  • Porous cement concrete was developed to prevent hydroplaning of airway pavement or to reduce noise emission in highway. In has been introduced in domestic since early 1980' and applied to a pedestrian road or bike way. The concrete, however, has problems such as lack of optimized mix design, low strength and deterioration, etc. The purpose of this study is to manufacture porous cement concrete using blast-furnace slag to enhance mechanical properties. The results of this study are as follows; the compressive strength range is 102∼247kgf/㎠, the tensile strength range is 16∼70kgf/㎠, the bending strength range is 43∼70kgf/㎠, and the coefficient permeability range is 6.79 ×10-2∼1.17∼10-1cm/sec. To develope high-performance porous concrete, further studies are needed on optimum mixture of fineness modulus and admixture.

  • PDF