• 제목/요약/키워드: low buildings

검색결과 1,067건 처리시간 0.028초

Dense Downtown vs. Suburban Dispersed: A Pilot Study on Urban Sustainability

  • Wood, Antony;Du, Peng
    • 국제초고층학회논문집
    • /
    • 제6권2호
    • /
    • pp.113-129
    • /
    • 2017
  • This paper presents the initial findings of a ground-breaking two-year CTBUH-funded research project investigating the real environmental and social sustainability of people's lifestyles in a number of high-rise residential towers in downtown Chicago, and a comparable number of low rise homes in suburban Oak Park, Chicago - based on actual energy bills and other real data. The study is ground-breaking because, to date, similar studies have been mostly based on very large data sets of generalized data regarding whole-city energy consumption, or large-scale transport patterns, which often misses important nuances. This study has thus prioritized quality of real data (based on around 250 households in both high rise and low rise case studies), over quantity. In both urban and suburban cases, the following factors have been assessed: (i) home operational energy use, (ii) embodied energy of the dwelling, (iii) home water consumption, (iv) mobility and transport movements, (v) urban/suburban Infrastructure, and (vi) quality of life. The full results of this seminal study will be published in the form of a CTBUH Research Report publication in 2017. Presented below is an overview of the initial (and, currently, unverified) findings of the research, together with the limitations of the study that should be taken into account, as well as future plans for developing this important pilot study.

The Impact of Supertall Density on City Systems

  • Price, Bill;Bickerdyke, Andrew;Borchers, Meike;Gabbitas, Tim;Hailey, Lee
    • 국제초고층학회논문집
    • /
    • 제6권4호
    • /
    • pp.327-332
    • /
    • 2017
  • This paper discusses several topics associated with the densification caused by supertall buildings and their impact on city systems. The paper covers five key areas where a supertall tower creates a concentration of needs and effects. First, the paper comments on population shifts towards the city and how they affect carbon footprint, utilities infrastructure and transport. The effect of single- and mixed-use towers is discussed in the context of population density. The second section brings the issues of transit, accessibility and master planning into focus. The use and criticality of public transport, cycling and walking is described. Servicing and deliveries using freight consolidation and shared systems is also discussed along with their contribution to the culture of sustainable travel. In the third section the paper reflects on supertall buildings' below-ground utilities and drainage provision, particularly the challenges faced in established city infrastructures. The utilities issues associated with supertall concentration (in land-use terms) compared to equivalent low-rise distribution is also commented on in the context of surface water runoff. In the fourth section, the topic of supertall sustainability is discussed and how city systems need to respond to create desirable and affordable space for occupiers. The changing need for vertical communities, 'stacked neighbourhoods' and the notion of a micro-city is described. Finally, the paper considers the energy consumption and resilience of supertall buildings in the context of basic geometry, façade design, climate and mixed-use benefits as they impact city systems.

경관계획 및 설계 기준에 관한 연구 - 건축물 높이와 산림스카이라인의 조화를 중심으로 - (A Study on the Criteria of Landscape Planning and Design - Focusing on the Harmony of Building-Heights and Mountain-Skyline -)

  • 최형석
    • 한국환경복원기술학회지
    • /
    • 제11권1호
    • /
    • pp.39-51
    • /
    • 2008
  • These days, one of the issues well discussed is the obstruction or screen of sight to mountain-skyline by buildings. So question is to which heights buildings should be constructed over mountain-skyline and then harmony can be realized between mountain-skyline and building-outline. Based on the mentioned above, this study intends to find out the proper projection- level of buildings over background mountain-skyline when considering the types of mountain-skyline, building-outline and building-layout. The results of this study are first, the proper projection-ratio of buildings over background mountain-skyline can be 0.1 because assessment values on harmony-level are more than 3.0 in almost cases, second, the building-outline influences on the assessment values of harmony-level when the types of mountain-skyline are formed left-high & right-low and right-high & left-low, third, building-layout doesn't influence on the assessment va lues of harmony-level, finally, statistically difference doesn't exist between expert group and non-expert group in the assessment values of harmony-level.

상세재해지도를 고려한 경기지역 학교건축물의 내진성능평가 (Seismic Performance Evaluation of School Buildings in Gyunggi Region Considering Seismic Hazard Map)

  • 유한국;박태원;이상현;정란;조승호
    • 한국안전학회지
    • /
    • 제24권4호
    • /
    • pp.66-73
    • /
    • 2009
  • Since the school buildings are generally used as public shelters when the natural disasters such as flood and earthquake occur, it must be designed to show enough structural performance when subject to earthquake. Major failure mode of the school buildings observed in past earthquakes were shear failure of column of which length is shortened by infilled masonry blocks. In this study, the seismic risk of the reinforced concrete school building structure was evaluated by using the seismic performance evaluation methods of low-story RC structures developed in Japan and the required seismic performance index which is obtained according to the KBC2008 seismic hazard map and soil types. In this paper, the seismic performance of the school building is evaluated by considering this short-column effects, building shape and deterioration.

소규모 철근콘크리트 건축물을 위한 비선형해석 프로그램 비교 II (Comparison of Nonlinear Analysis Programs for Small-size Reinforced Concrete Buildings II)

  • 유창환;김태완;박홍근
    • 한국지진공학회논문집
    • /
    • 제19권5호
    • /
    • pp.229-238
    • /
    • 2015
  • For small-size reinforce-concrete buildings, Midas Gen, OpenSees, and Perform-3D, which are structural analysis programs that are most popularly used at present, were applied for nonlinear static pushover analysis, and then difference between those programs was analyzed. Example buildings were limited to 2-story frames with irregular shaped walls. Analysis result showed that there were more differences than for frames only and frames with rectangular walls, but it was not so significant. Nevertheless, the capacity curve were different in some buildings, which is attributed to shape and location of walls, and feature of the analysis program. Especially, selection of automatic or manual input in Midas Gen, or nonlinear wall elements in Perform3D can affect the capacity curve and performance of the buildings. Therefore, the program users should understand the feature of the program well, and then conduct performance assessment. The result of this study is limited to low-story buildings so that it should be noted that it is possible to get different results for mid- to high-rise buildings.

노후 초등학교 건물에너지 절감을 위한 요소기술의 성능 비교 (Comparing Performances of Factors for Reducing Energy at Deteriorated Elementary School Buildings)

  • 이상춘;최영준;김현기;최율
    • KIEAE Journal
    • /
    • 제12권2호
    • /
    • pp.111-116
    • /
    • 2012
  • Faced with the international issue of environmental problems from global warming and energy consumption, the Korean Government has made many efforts on reducing energy and $CO_2$ emission under the motto of "Low-Carbon Green Growth". In order to reduce energy in the building sector, severe design standards and regulations on saving energy in new buildings have been established. Now, it is necessary to focus on deteriorated buildings where applications of energy saving designs and techniques have been insufficient, for maximizing energy saving in the building sector. Specially, it is very important to reduce energy through the remodeling process at deteriorated school buildings which were built over 20 years ago and sharply changed into the excessive energy consumption structure from new educational curricula. Thus, this paper examined the effects of potential factors to reduce energy at deteriorated elementary school buildings using the energy simulation on the Visual DOE 4.0 program. Among applied factors of insulations, southern louver, window's SHGC, indoor setup temperature, and system efficiency, all factors except window's SHGC turned out contribute to reduce energy at the deteriorated elementary school buildings, compared with the baseline energy performance.

Earthquake performance assessment of low and mid-rise buildings: Emphasis on URM buildings in Albania

  • Bilgin, Huseyin;Huta, Ergys
    • Earthquakes and Structures
    • /
    • 제14권6호
    • /
    • pp.599-614
    • /
    • 2018
  • This study focuses on the earthquake performance of two URM buildings having typical architectural configurations common for residential use constructed per pre-modern code in Albania. Both buildings are unreinforced clay brick masonry structures constructed in 1960 and 1984, respectively. The first building is a three-storey unreinforced one with masonry walls. The second one is confined masonry rising on five floors. Mechanical characteristics of masonry walls were determined based on experimental tests conducted according to ASTM C67-09 regulations. A global numerical model of the buildings was built, and masonry material was simulated as nonlinear. Pushover analyses are carried out to obtain capacity curves. Displacement demands were calculated according to Eurocode 8 and FEMA440 guidelines. Causes of building failures in recent earthquakes were examined using the results of this study. The results of the study showed that the URM building displays higher displacement and shear force demands that can be directly related to damage or collapse. On the other hand, the confined one exhibits relatively higher seismic resistance by indicating moderate damage. Moreover, effects of demand estimation approaches on performance assessment of URM buildings were compared. Deficiencies and possible solutions to improve the capacity of such buildings were discussed.

Seismic evaluation and upgrading of RC buildings with weak open ground stories

  • Antonopoulos, T.A.;Anagnostopoulos, S.A.
    • Earthquakes and Structures
    • /
    • 제3권3_4호
    • /
    • pp.611-628
    • /
    • 2012
  • The inelastic earthquake response of existing, reinforced concrete buildings with an open ground story, designed according to the old Greek codes, is investigated before and after their seismic strengthening with steel braces restricted to the open ground stories. The seismic performance evaluation is based on Part 3 of Eurocode 8 for assessment and retrofitting of buildings. Three and five-story, symmetric and non-symmetric buildings are subjected to a set of seven pairs of synthetic accelerograms, compatible with the design spectrum, and conclusions are drawn regarding the effectiveness of the strengthening solutions. Seismic behavior of the selected models confirms results of previous work regarding the insufficient capacity of the open ground stories for design level earthquakes. It is also shown that strengthening only the weak ground story, a choice having the substantial advantage of low cost and continued usage of the building during its seismic retrofitting, can remove the inherent weakness without shifting the problem to the stories above and thus making such buildings at least as strong as those without a weak first story. This partial strengthening is possible for symmetric as well as eccentric buildings, in which torsion plays a further detrimental role.

석면함유 건축물의 관찰조사를 통한 실내공기 중 섬유 농도 변화 요인 추정 (Estimation of Factors Influencing Airborne Fiber Concentrations through an Observation Survey of Asbestos-containing Materials in Buildings)

  • 이승철;김부욱;이광용;신용철
    • 한국산업보건학회지
    • /
    • 제25권2호
    • /
    • pp.174-183
    • /
    • 2015
  • Objectives: The objective of this study is the estimation of factors influencing airborne fiber concentrations by means of an observation survey of asbestos-containing materials in buildings. Methods: Forty-five samples were collected from four commercial buildings by NIOSH Method 7400 and classified according to current condition, potential activity, construction year, and operations and maintenance(O&M). Results: Airborne fiber concentrations by current condition(classified as good, fair and poor) were significantly different(p<0.05). Concentrations by potential activity were significantly different among groups(p<0.05), and those from the low activity group were higher than those from the middle activity group. Based on construction year, airborne fiber concentrations from the decade of the 1990's were higher than those from the 1960's. When O&M status was considered, airborne fiber concentrations from 1960's buildings were lower than those buildings not operated and maintained(p<0.01), because dust generation was influenced by O&M status. It was found that airborne fiber concentrations were related to current condition and potential activity via regression analysis, but the coefficient of determination was low. Also, correlation analysis showed that the higher the potential activity, the more current condition is worsened, but the relationship was not significant(r=-0.455, p>0.05). Conclusions: Airborne fiber concentrations in asbestos-containing buildings had weak relationships with current condition and potential activity.

교육 시설기준 변화에 따른 학교건축물의 에너지원 변화에 관한 연구 (A study on the Energy resource in School Buildings with the Changes of Educational Facilities Standard)

  • 김태우;이강국;홍원화
    • KIEAE Journal
    • /
    • 제10권6호
    • /
    • pp.73-80
    • /
    • 2010
  • Since the Korean War, Korea has experienced modernization. The population increase by baby booming has asked for more space for educational facilities. In such a situation, the purpose of educational facilities was to accommodate continuously increasing students, rather than seeking for quantitative demands. In addition, in accordance with social changes, educational shifts were required. After the revision of the seventh national curriculum in education in 1997, the school buildings became varied. The design of buildings in accordance with educational curriculum has been improved, but still lack of forming comfortable environment and considering energy efficiency in school buildings. For the improvement of educational environments, educational media such as TV and computers have been provided, and energy systems, including heating and cooling systems, has been continuously increased. As a result, it appeared that energy use in school buildings and facilities has been steadily increased and that the structure of energy consumption has been also changed, especially with regard to electricity use. Living in the 21st century, human beings face global environmental issues, such as global warming, geographical climate changes, and ozone destruction that are the consequences of fossil energy use. Therefore, even in industrial areas, considering a counterplan for low energy use is being paid attention. Starting with Kyoto Protocol in 1992, people try to decrease carbon dioxide and to develop alternative energies (i.e. natural energy); for example, solar energy, wind force, terrestrial heat, and water power. Advanced countries already set up a criterion for $CO_2$ decrease ranging from office buildings to residential houses and also propose alternatives for the $CO_2$ decrease. However, there is no such a plan for low energy use and $CO_2$ decrease in school facilities, and any research on the actual conditions was not accomplished. Thus, this study examines energy demand in classrooms that take up a large portion of energy demand in school building structure.