• Title/Summary/Keyword: low Rayleigh number

Search Result 54, Processing Time 0.03 seconds

Capacity Bounds on the Ergodic Capacity of Distributed MIMO Systems over K Fading Channels

  • Li, XingWang;Wang, Junfeng;Li, Lihua;Cavalcante, Charles C.
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.7
    • /
    • pp.2992-3009
    • /
    • 2016
  • The performance of D-MIMO systems is not only affected by multipath fading but also from shadowing fading, as well as path loss. In this paper, we investigate the ergodic capacity of D-MIMO systems operating in non-correlated K fading (Rayleigh/Gamma) channels. With the aid of majorization and Minkowski theory, we derive analytical closed-form expressions of the upper and lower bounds on the ergodic capacity for D-MIMO systems over non-correlated K fading channels, which are quite general and applicable for arbitrary signal-to-noise ratio (SNR) and the number of transceiver antennas. To intuitively reveal the impacts of system and fading parameters on the ergodic capacity, we deduce asymptotic approximations in the high and low SNR regimes. Finally, we pursue the massive MIMO systems analysis for the lower bound and derive closed-form expressions when the number of antennas at BS grows large, and when the number of antennas at transceivers becomes large with a fixed and finite ratio. It is demonstrated that the proposed expressions on the ergodic capacity accurately match with the theoretical analysis.

An empirical model of air bubble size for the application to air masker (에어마스커의 기포크기 추정 경험적 모델)

  • Park, Cheolsoo;Jeong, So Won;Kim, Gun Do;Park, Youngha;Moon, Ilsung;Yim, Geuntae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.4
    • /
    • pp.320-329
    • /
    • 2021
  • In this paper, an empirical model of air bubble size to be applied to an air masker for reduction of underwater radiation noise is presented. The proposed model improves the divergence problem under the low-speed flow condition of the existing model derived using Rayleigh's jet instability model and simple continuity condition by introducing a jet flow velocity of air. The jet flow velocity of air is estimated using the bubble size where the liquid is quiescent. In a medium without flow, the size of the bubble is estimated by an empirical method where bubble formation regime is divided into a laminar-flow range, a transition range, and a turbulent-flow range based on the Reynolds number of the injected air. The proposed bubble size model is confirmed to be in good agreement with the Computational Fluid Dynamics (CFD) analysis result and the experimental results of the existing literature. Using the acoustic inversion method, the air bubble population is estimated from the insertion loss measured during the air injection experiment of the air- masker model in a large cavitation tunnel. The results of the experiments and the bubble size model are compared in the paper.

Comparison of Performance of stepwise serial processing and stepwise parallel processing for Cell Search in WCDMA System (WCDMA 시스템에서 셀 탐색의 단계별 직렬 처리 및 병렬 처리의 성능 비교)

  • 오호근;송문규
    • Proceedings of the IEEK Conference
    • /
    • 2000.11a
    • /
    • pp.73-76
    • /
    • 2000
  • We investigate the stepwise parallel processing of the serial search which can success the co]1 search at low Ec/Io. The single path Rayleigh fading channel which is worst-case channel model is considered. The typical 3-step cell search is used. The probabilities of detection, miss and false alarm for each step are used in closed forms based on the statistics of CDMA noncoherent demodulator output. The optimal power allocation to each channel and The optimal number of post-detection integrations for each step is obtained. Also, the cumulative probability distribution of the average eel] search time for serial search methods are compared.

  • PDF

Error Performance of Serially Concatenated Space-Time Coding

  • Altunbas, Ibrahim;Yongacoglu, Abbas
    • Journal of Communications and Networks
    • /
    • v.5 no.2
    • /
    • pp.135-140
    • /
    • 2003
  • In this paper, we investigate the error performance of a serially concatenated system using a nonrecursive convolutional code as the outer code and a recursive QPSK space-time trellis code as the inner code on quasi-static and rapid Rayleigh fading channels. At the receiver, we consider iterative decoding based on the maximum a posteriori (MAP) algorithm. The performance is evaluated by means of computer simulations and it is shown that better error performance can be obtained by using low complexity outer and/or inner codes and the Euclidean distance criterion based recursive space-time inner codes. We also obtain new systems with large number of trasmit and/or receive antennas providing good error performance.

Effect of Natural Convection on the Heat Transfer in a Latent Heat Storage System (잠열축열시스템의 축열과정에서 자연대류의 영향에 관한 연구)

  • Ryu, S.N.;Han, G.Y.
    • Solar Energy
    • /
    • v.19 no.2
    • /
    • pp.29-36
    • /
    • 1999
  • Heat transfer characteristics of a low temperature latent heat storage system during the heat storage stage was examined for the circular finned tubes using fatty acid which shows the big density difference during melting as phase change materials. The heat storage vessel has the dimension of 530 mm height, 74 mm inside diameter and inner heat transfer tube is 480 mm in height and 13.5 mm outside diameter. Hot water was employed as the heat transfer fluid. During the heat storage stage, it was found that both conduction and natural convection were the major heat transfer mechanism. It was also found that the effect of natural convection on the heat transfer was more significant for the unfinned tube system than that for the finned tube system. The experimentally determined overall heat transfer coefficients were in the range of $50{\sim}250W/m^2K$ and the correlation for natural convection heat transfer as a function of Nusselt and Rayleigh number was proposed.

  • PDF

Mixed Convection in a Horizontal Annulus with a Rotating Cylinder (하나의 실린더가 회전하는 수평 환형 공간에서의 혼합 대류)

  • Yoo Joo-Sik;Ha Dae-Hong
    • Journal of computational fluids engineering
    • /
    • v.6 no.3
    • /
    • pp.1-9
    • /
    • 2001
  • Mixed convection in a horizontal annulus is considered, and the effect of a forced flow on the natural convective flow is investigated. The inner cylinder is hotter than the outer cylinder, and the outer cylinder is rotating with constant angular velocity with its axis at the center of the annulus. The unsteady streamfunction-vorticity equation is solved with a finite difference method. For the fluid with Pr=0.7, there appear flows with two eddies, one eddy, or no eddy according the Rayleigh and Reynolds numbers. The rotation of the outer cylinder reduces the heat transfer rate at the wall of the annulus. The oscillatory multicellular flow of a low Prandtl number fluid with Pr=0.01 can be effectively suppressed by the forced flow.

  • PDF

High prandtl number natural convection in a low-aspect ratio rectangular enclosure (종횡비 가 낮은 직각밀폐용기내 의 Prandtl 수 가 큰 유체 의 자연대류 에 관한 실험적 연구)

  • 이진호;황규석;현명택
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.6
    • /
    • pp.750-756
    • /
    • 1985
  • Experimental investigation was carried out to study the natural convection of water and silicon oil due to end temperature differences in a horizontally insulated rectangular enclosure of aspect ratio 0.1 with a special attention on the core configuration in the laminar boundary-layer flow regime. Rayleigh number ranges covered herein are Ra=4.40 * 10$^{6}$ -9.64 * 10$^{7}$ for water and Ra=1.69*10$^{5}$ -3.80*10$^{6}$ for silicon oil, respectively. In the case of water, for Ra.geq.2.21 * 10$^{7}$ there appeared distinct horizontal thermal layers adjacent to the horizontal boundaries in the core and the temperature distribution outside the horizontal thermal layers, i.e., in the mid-core region, is vertically stratified. The core flow pattern was shown to be nonparallel with a weak back flow in the mid-core for Ra.geq.3.63 *10$^{7}$ . In the case of silicon oil, distinct horizontal thermal layers appeared along the core horizontal boundaries for Ra.geq.1.27 * 10$^{6}$ with a stratified temperature distribution in the mid-core, but the core flow pattern in this case was shown to be parallel. In addition, secondary flow appeared near the hot wall for Ra.geq.3.80 * 10$^{6}$ . Nusselt number, Nu, was found to be proportional to R $a^{0.3}$ for water and R $a^{0.28}$ for silicon oil in the boundary-layer flow regime. There also in an indication from the comparison with other results that Nu is independent of aspect ratio for water in the boundary-layer flow regime in low aspect ratio enclosures.res.

Analysis of M-ary Antipodal Communication System for Multiple Access in Additive White Gaussian Noise (AWGN에서 다중접속을 위한 M진 Antipodal 초광대역 통신 시스템의 성능 분석)

  • Lee, Jung-Suk;Kim, Jong-Han;Kim, Yoo-Chang;Kim, Jung-Sun;Kim, Won-Hoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.1A
    • /
    • pp.1-12
    • /
    • 2002
  • Ultra Wideband (UWB) system uses wide band signal, which power spectral density likes as a noise floor, so UWB system can be used high speed communication without interfering with other communication system. As this system doesn't use radio frequency carrier. Its structure would be very simple and consume very low power. For the first time, we adopted Rayleigh monopulse multiple access system. And under the AWGN, we analysis and compare error probability, the number of user and data rate of the two methods that pulse position modulation and antipodal. In the result, We concluded that the antipodal method had much better probability of error, the number of user and data rate than PPM.

Near-BER lossless Asymmetric 2PAM non-SIC NOMA with Low-Complexity and Low-Latency under User-Fairness

  • Chung, Kyuhyuk
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.13 no.2
    • /
    • pp.43-51
    • /
    • 2021
  • As the number of mobile devices has been increasing tremendously, system capacity should be enlarged in future next generation communication, such as the fifth-generation (5G) and beyond 5G (B5G) mobile networks. For such future networks, non-orthogonal multiple access (NOMA) has been considered as promising multiple access technology. In this paper, to reduce both latency and complexity in existing NOMA, we propose non-successive interference cancellation (SIC) NOMA with asymmetric binary pulse amplitude modulation (2PAM), nearly without bit-error rate (BER) loss. First, we derive the closed form of BER expressions for non-SIC NOMA with asymmetric 2PAM, especially under Rayleigh fading channels. Then, it is shown that the BER performance of the stronger channel user who is supposed to perform SIC in conventional NOMA can be nearly achieved by the proposed non-SIC NOMA with asymmetric 2PAM, especially without SIC. Furthermore, we also show that the BER performance of the weaker channel user in conventional NOMA can be more closely achieved by the proposed non-SIC NOMA with asymmetric 2PAM. These BERs are shown to be achieved over the part of the power allocation range, which is consistent with the NOMA principle of user fairness. As a result, the non-SIC NOMA scheme with asymmetric 2PAM could be considered as a promising NOMA scheme toward next generation communication.

Experimental Study on Effect of Inclination Angle on Natural Convection from Cylindrical Heatsinks with Plate Fins (평판-휜을 갖는 기울어진 원통형 히트 싱크의 자연 대류에 경사각이 미치는 영향에 대한 실험적 연구)

  • Park, Kuen Tae;Kim, Hyun Jung;Yoo, Jaisuk;Lee, Moon Gu;Kim, Dong-Kwon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.4
    • /
    • pp.343-350
    • /
    • 2015
  • The natural convection heatsink is the most commonly used cooling device, especially for high-power LED lights, because of its reliability and low long-term cost. High power LED lights are generally used in an inclined configuration for street lamps and security lamps. However, it was difficult to estimate the thermal performance of an inclined heatsink, because the results from previous studies are not applicable to the inclined configuration. In this study, we measured the thermal performance of an inclined cylindrical heatsink with plate fins. Various fin numbers, fin heights, base temperatures, and inclination angles ($30^{\circ}$ and $60^{\circ}$) were examined. Based on the experimental results, the Nusselt number correlation is presented. This correlation is applicable when the Rayleigh number, ratio of the fin height to cylinder diameter, and fin number are in the ranges 100,000-600,000, 1/6-1/2, and 9-72, respectively.