• Title/Summary/Keyword: loss factor

Search Result 2,791, Processing Time 0.035 seconds

A Study on the Dynamic Properties by Loading Time of Floor Impact Noise Insulation Materials (바닥충격음 완충재의 재하시간에 따른 동적 특성 연구)

  • Kim, Heung-Sik;Jin, Pil-Hwa;Joo, Si-Woong;Jung, Sung-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.942-945
    • /
    • 2005
  • The purpose of this study is to suggest a fundamental data for change of dynamic properties according to the loading time of resilient materials. 18 kinds of resilient materials included 4 representative types were measured at the load time of 24hours and 2hours by the method of Korea standard (KS F 2868) measuring the dynamic stiffness and the loss factor of materials under floating floors. As a result, the dynamic stiffness was increased rapidly in case of expandable polystyrene and rubber materials according to the load time, especially before 2 hours. The loss factor was represented that rubber materials with high elasticity are high, and expandable polystyrene, polyester, poly ethylene materials with low elasticity are low.

  • PDF

Analysis of Influence Factors on Dynamic Properties of Floor Impact Noise Insulation Materials (바닥충격음 완충재의 동적특성에 영향을 미치는 요인 분석)

  • Kim, Heung-Sik;Joo, Si-Woong;Kim, Dae-Jun;Kim, Byeung-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.946-949
    • /
    • 2005
  • In this paper, influence factors on dynamic properties of floor impact noise insulation materials are suggested. For this purpose measurements on the dynamic stiffness and the loss factor of resilient materials are carried out by Korea standard (KS F 2868) according to the change of density, thickness, design pattern, and composition of materials. As a result the values of dynamic stiffness was decreased at high density and thick thickness, and that of loss factor was increased at low density. For dynamic properties, the pattern of lattice and waffle type material is better than that of plat type, and the mixed composition of materials is better than the composition of double layer materials at same thickness.

  • PDF

Dielectric Changes During the Curing of Epoxy Resin Based on the Diglcidyl Ether of Bisphenol A (DGEBA) with Diamine

  • 김홍경;차국헌
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.11
    • /
    • pp.1329-1334
    • /
    • 1999
  • The curing characteristics of diglycidyl ether of bisphenol A (DGEBA) with diaminodiphenylmethane (DDM) as a curing agent were studied using differential scanning calorimetry (DSC), rheometrics mechanical spectrometry (RMS), and dielectric analysis (DEA). The isothermal curing kinetics measured by DSC were well represented with the generalized auto-catalytic reaction model. With the temperature sweep, the inverse relationship between complex viscosity measured by RMS and ionic conductivity obtained from DEA was established indicating that the mobility of free ions represented by the ionic conductivity in DEA measurement and the chain segment motion as revealed by the complex viscosity measured from RMS are equivalent. From isothermal curing measurements at several different temperatures, the ionic conductivity contribution was shown to be dominant in the dielectric loss factor at the early stage of cure. The contribution of the dipole relaxation in dielectric loss factor became larger as the curing further proceeded. The critical degrees of cure, at which the dipolar contribution in the dielectric loss factor starts to appear, increases as isothermal curing temperature is increased. The dielectric relaxation time at the same degree of cure was shorter for a sample cured at higher curing temperature.

Improved Momentum Exchange Theory for Incompressible Regenerative Turbomachines (II) - Loss Model and Performance Prediction - (비압축성 재생형 기계에 대한 개선된 운동량 교환 이론 (II) - 손실 모델 및 성능 예측 -)

  • Park Mu Ryong;Chung Myung Kyoon;Yoo Il Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.10
    • /
    • pp.1247-1254
    • /
    • 2004
  • In momentum exchange theory the loss models for the circulatory flow is critically important. But because of lack of loss model on the circulatory flow, analysis model on regenerative turbomachines is not available in the open literature. In the present study circulatory loss is evaluated by combining bend's losses. Through the comparison with the previous experimental data on linear pressure gradient, a combination factor is suggested in terms of the aspect ratio of a channel. Applying this factor to two kinds of regenerative blowers the predicted results are found to be in good agreement with the experimental data of the overall performance and the head distribution along the rotational direction. Especially, the comparison with the head distribution demonstrates the accuracy of hydraulic model and loss model suggested in the present study. And the comparison with the overall performance confirms the validness of physical models as well as loss models suggested in the present study.

Loss Analysis of Three Phase Induction Motor Connected to Single Phase Source (단상전원에 접속된 3상 유도전동기의 손실분석)

  • Kim, Do-Jin;Jwa, Chong-Keun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.121-126
    • /
    • 2008
  • This paper analyzes the losses of a Steinmetz connection three-phase induction motor which is supplied by a single-phase source. The T-type equivalent circuit which is taken no-load losses into account is used to determine phase converter capacitive reactances at starting and rated speed by using the condition of the minimum voltage unbalance. The starting and the operating capacitor are replaced at the slip of the same voltage unbalance factor points which are depicted using two capacitive reactances. The operation characteristics are investigated by comparing with those of three-phase balanced operation to find the feasibility of single-phase operation. To analyze the losses of this motor, the output power decrease factor(OPDF), the loss ratio(LR), the no load loss ratio(NLLR), the copper loss ratio(CLR), the stator copper loss ratio(SCLR), and the rotor copper loss ratio(RCLR) are defined and simulated in the whole slip range. The simulated results show that OPDF is maintained almost uniformly, LR is low at low speed and high at high speed, CLR is higher !ban NLLR, but CLR varies concavely and NLLR varies convexly at high speed, SCLR is low at low speed and high at high speed, but SCLR varies convexly at high speed, and RCLR is nearly opposite to SCLR.

Analysis on the Effects of the Heat Loss Coefficient on the Operation Time of Sprinkler in Compartment Fire (구획 화재에서 스프링클러 열 손실계수 변화에 따른 작동 시간 분석)

  • You, Woo Jun
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.34-39
    • /
    • 2018
  • In this study, the experiment conditions for the variation of heat release rate in compartment space were constructed to analyze the effects of fire spread and the operation time of sprinkler in accordance with the heat loss of the sprinkler's heat element. The compartment composed of fire board (width = 0.3 m, height = 0.5 m, length = 3.0 m), are manufactured to measure the temperature distributions in the inner space, the mass loss rate and heat release rate during the experiment of N-heptane pool fire test. Also, the operation time of sprinkler is analyzed with the installation of sprinkler and C-factor using Fire Dynamics Simulator Ver.6 under the experiment conditions. The results show that the operation time of sprinkler, which has RTI $100(m{\cdot}s)^{0.5}$ operating temperature $70^{\circ}C$, is 30 s~60 s for C-factor = 0 and 1, 62 s~92 s for C-factor = 3, and 120 s over for C-factor = 5, respectively.

Development of a GIS Method for the Automatic Calculation of LS Factor of USLE (GIS를 이용한 USLE 지형인자(LS) 자동계산 방법에 관한 연구)

  • 우창호;황국웅
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.26 no.3
    • /
    • pp.162-177
    • /
    • 1998
  • Conentionally, LS factor for the USLE suggested by Wischmeier has been computed manually on topographic maps based on one dimensional approach. But outcomes of the equation could be severely affected by the convergence and divergence of surface runoff at complex terrains. Thus the objective of this research are to develop a method to automatically compute LS factor based on the multiple flow algorithm, and to test the accuracy of this method by comparing outcomes of this method to previous measurements or estimations of soil erosion. The program for the automatic calculation of LS factor was developed by utilizing Fox Pro 4.5, and outcomes of the program is designed to input to IDRISI. The accuracy test of LS factor was carried out by comparing the actual measurements of soil loss at two test sites in and around of Suwon. The calculated volume of soil erosion at Buju mountain, Mokpo, was also compared to the outcome of a previous research based on the LS factor calculated by the conventional onedimensional approach. The outcomes of this research are as follows. First, the computed L based on the multiple flow algorithm for concae slopes are greater than those of convex slopes,. Second, the estimated soil loss based on this method at the test site in Mokpo is much greater than the outcomes based on the conventional one-dimensional approach. It can e concluded that the application of this automatic calculation method of LS factor can improve the accuracy of USLE and facilitate soil erosion prevention methods.

  • PDF

Monthly Sediment Yield Estimation Based on Watershed-scale Application of ArcSATEEC with Correction Factor (보정계수 적용을 통한 유역에 대한 ArcSATEEC의 월별 토양유실량 추정 방안 연구)

  • Kim, Eun Seok;Lee, Hanyong;Yang, Jae E;Lim, Kyoung Jae;Park, Youn Shik
    • Journal of Soil and Groundwater Environment
    • /
    • v.25 no.3
    • /
    • pp.52-64
    • /
    • 2020
  • The universal soil loss equation (USLE), a model for estimating the potential soil loss, has been used not only in research areas but also in establishing national policies in South Korea. Despite its wide applicability, USLE cannot adequately address the effect of seasonal variances. To overcome this limit, the ArcGIS-based Sediment Assessment Tool for Effective Erosion (ArcSATEEC) has been developed as an alternative model. Although the field-scale (< 100 ㎡) application of this model produced reliable estimation results, it is still challenging to validate accuracy of the model estimation because it only estimates potential soil losses, not the actual sediment yield. Therefore, in this study, a method for estimating actual soil loss based on the ArcSATEEC model was suggested. The model was applied to eight watersheds in South Korea to estimate sediment yields. Correction factor was introduced for each watershed, and the estimated sediment yield was compared with that of the estimated yield by LOAD ESTimator (LOADEST). Sediment yield estimation for all watersheds exhibited reliable results, and the validity of the proposed correction factor was confirmed, suggesting the correction factor needs to be considered in estimating actual soil loss.

A Study to Determine the Rainfall Erosivity Factor of Universal Soil Loss Equation using Recent Rainfall Data (최근 강수 자료를 이용한 범용토양유실공식의 강우침식능인자 정의에 관한 연구)

  • Kim, Jonggun;Jang, Jin Uk;Seong, Gak Gyu;Cha, Sang Sun;Park, Youn Shik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.6
    • /
    • pp.13-20
    • /
    • 2018
  • Universal Soil Loss Equation (USLE) has been widely used to estimate potential soil loss because USLE is a simple and reliable method. The rainfall erosivity factor (R factor) explains rainfall characteristics. R factors, cited in the Bulletin on the Survey of the Erosion of Topsoil of the Ministry of Environment in the Republic of Korea, are too outdated to represent current rainfall patterns in the Republic of Korea. Rainfall datasets at one minute intervals from 2013 to 2017 were collected from fifty rainfall gauge stations to update R factors considering current rainfall condition. The updated R factors in this study were compared to the previous R factors which were calculated using the data from 1973 to 1996. The coefficient of determination between the updated and the previous R factors shows 0.374, which means the correlation is not significant. Therefore, it was concluded that the previous R factors might not explain current rainfall conditions. The other remarkable result was that regression equations using annual rainfall data might be inappropriate to estimate reasonable R factors because the correlation between annual rainfall and the R factors was generally unsatisfy.

Study on The Electrical Characteristic Extraction of PI(Poly Imide) Substrate using Capacitor Method (캐패시터를 이용한 PI (Poly Imide) 기판의 전기적 특성 추출에 관한 연구)

  • Lee, Gwang-Hoon;Yoo, Chan-Sei;Lee, Woo-Sung;Yang, Ho-Min;Jung, Han-Ju;Kim, Hong-Sam;Lee, Bong-Joon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.210-210
    • /
    • 2007
  • RF circuit을 구현하는데 있어서 기판의 전기적 특성을 정확하게 아는 것은 매우 중요하다. 왜냐하면 초고주파로 갈수록 기판의 전기적인 특성이 circuit에 많은 영향을 미치고 이러한 영향을 고려한 circuit를 설계해야 원하는 결과를 얻을 수 있기 때문이다. 본 연구에서는 현재 사용되고 있는 PI 기판의 전기적인 특성인 유효 유전율과 loss tangent 값을 캐패시터를 이용해 정확하게 측정하고자 했다. 캐패시터의 conductor material은 Cu를 사용하였고 PI 기판의 투께는 25um 를 이용하였다. PI 기판의 유효 유전율은 캐패시터 측정에 의한 data률 EM simulation tool 을 통해 분석한 후 간단한 수식에 의해 구했다. 또한 PI 기판의 loss tangent 값을 구하기 위해 캐패시터의 dissipation factor를 분석하였다. 캐패시터의 dissipation factor는 dielectric loss, AC 저항에 의한 loss, DC 저항에 의한 loss를 포함한다, DC 저항에 의한 loss는 dissipation factor에 차지하는 비율이 낮기 때문에 생략이 가능하다. 하지만 AC 저항에 의한 loss는 주파수에 비례하여 값이 커지게 된다. 따라서 주파수가 올라 갈수록 dissipation factor도 상승하게 되는데 주파수의 전 대역에서 AC 저항에 의한 loss를 보정해주면 dielectric loss를 얻을 수 있다. 추출된 dielectric loss를 통해 PI 기판의 loss tangent 값을 구하였다. 캐패시터를 이용한 PI 기판의 전기적 특성 추출은 간단한 구조를 통해 얻을 수 있기 때문에 다른 재료의 기판의 전기적 특성을 추출하는데도 이용이 용이하다.

  • PDF