• Title/Summary/Keyword: loss angle

Search Result 848, Processing Time 0.029 seconds

The Effect of Directivity of Antenna for the Evaluation of Abnormal Area Using Ground Penetrating Radar (지하투과레이더를 이용한 이상구간 평가 시 안테나 지향성의 영향)

  • Kang, Seonghun;Lee, Jong-Sub;Lee, Sung Jin;Park, Young-Kon;Hong, Won-Taek
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.11
    • /
    • pp.21-34
    • /
    • 2017
  • The ground penetrating radar (GPR) signal can be measured with different amplitudes according to the directivity, so the directivity of the antenna should be considered. The objective of this study is to investigate the directivity of antenna by analyzing the reflection characteristics of electromagnetic waves radiated from the antenna, and to evaluate effective range of angle that can inspect an abnormal area according to the directivity of antenna. For the measurement of the directivity, a circular metal bar is used as reflector and the signals are measured by changing the angle and the distance between reflector and antenna in the E- and H-plane. The boundary distance between the near field and the far field is determined by analyzing the amplitudes of reflected signals, and two points with different distances from each of near and far fields are designated to analyze radiation patterns in near and far fields. As a result of radiation pattern measurement, in the near field, minor lobes are observed at angle section at more than $50^{\circ}$ in both E- and H-plane. Therefore, antenna has the directivity for the direction of main lobe and minor lobes in near field. In the far field, antenna has the directivity for a single direction of main lobe because minor lobes are not observed. The amplitude of the signal reflected from the near field is unstable, but it can be distinguished from noise. Therefore, in the near field, the ground anomaly can be detected with high reliability. On the other hand, the amplitude of the signal reflected from the far field is stable, but it is hard to distinguish between reflected signal and noise because of the excessive loss of electromagnetic wave. The analyses of directivity in the near and the far fields performed in this study may be effectively used to improve the reliability of the analyses of abnormal area.

Comparison of Anterior Segment Features between Groups with or without Glaucoma in Pseudoexfoliation Syndrome (거짓비늘증후군에서 개방각녹내장 병합 유무에 따른 전안부 소견과 생체 계측치에 대한 비교)

  • Gu, Bon Hyeok;Choi, Sangkyung
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.11
    • /
    • pp.1049-1055
    • /
    • 2018
  • Purpose: To investigate the factors associated with glaucoma in patients with pseudoexfoliation syndrome by comparing features of the anterior segments and ocular biometry according to the presence or absence of open-angle glaucoma in pseudoexfoliation syndrome. Methods: We analyzed 96 patients (115 eyes) diagnosed as having pseudoexfoliation syndrome in this study. The patients were divided into two groups of simple pseudoexfoliation syndrome (64 patients, 76 eyes) and pseudoexfoliation glaucoma (32 patients, 39 eyes). We compared the age, sex, underlying disease, location of pseudoexfoliative material, iris change, degree of nuclear cataract, pupil dilatation, corneal endothelial cell counts, central corneal thickness, anterior chamber depth, axial length, corneal curvature, and intraocular pressure (IOP). Results: There were no significant differences between the two groups in terms of age (p = 0.694), sex (p = 0.161), diabetes (p = 0.440), hypertension (p = 0.238), pseudoexfoliative material observed in anterior capsule (p = 0.700), pupillary margin (p = 0.210), iris depigmentation (p = 0.526), pupillary ruff loss (p = 0.708), degree of nuclear cataract (p = 0.617), pupil dilatation (p = 0.526), central corneal thickness (p = 0.097), anterior chamber depth (p = 0.283), axial length (p = 0.095), or horizontal and vertical corneal curvature (p = 0.066 and 0.306, respectively). In pseudoexfoliation glaucoma, significantly higher IOP (p = 0.026), a high frequency of membrane formation (p = 0.047), and decreased corneal endothelial cell counts (p = 0.048) were observed. Conclusions: Pseudoexfoliation syndrome with open-angle glaucoma was shown to be associated with high IOP, decreased corneal endothelial cell counts, and a high frequency of membrane formation. Therefore, when such changes are observed in pseudoexfoliation syndrome patients, a higher risk of open-angle glaucoma should be recognized, and careful attentionis required accordingly.

Ventilation Effect of the Greenhouse with Folding Panel Type Windows (패널굴절방식 환기창 온실의 환기효과)

  • Kim, Jin-Young;Lee, Si-Young;Kim, Hyun-Hwan;Chun, Hee;Yun, In-Hak
    • Journal of Bio-Environment Control
    • /
    • v.11 no.1
    • /
    • pp.5-11
    • /
    • 2002
  • In this study, new development of natural ventilation window was accomplished to control environment of greenhouse with no use of farced ventilation during hot season. The ventilation effect of developed ventilation window was investigated in experimental greenhouse which was designed using side wall panel and folding type panel fur natural ventilation. Folding panel type ventilation window was designed to open upper part of the side wall and top of the roof using two hinges which are located bottom of the side wall and the roof panel to grab one side of each panels and guide the other side along with the guidance rail. Developed ventilation window has top ventilation part with maximum moving distance X=ι (1-cos$\theta$)=848.5 mm and side ventilation part with maximum moving distance Y=ι/2 $\times$sin$\theta$=1,184.4 mm at 45$^{\circ}$ of theoretical opening angle. It took 4.5 minutes to open roof vent fully and temperature at 1.2 and 0.8 m height decreased after 1 minute from starting opening and became equilibrium state maintaining 3-4$^{\circ}C$ difference after 2 minutes from complete opening. Air exchange rate was 15.2~39.3 h$^{-1}$ which was more than 10~15 h$^{-1}$ of continuous type and Venlo type greenhouse. The descent effect of temperature by ventilation windows was two times higher than Venlo type greenhouse.

Is It Appropriate to Insert Pedicle Screws at an Infected Vertebral Body in the Treatment of Lumbar Pyogenic Spondylodiscitis? (요추부 화농성 척추염의 수술적 치료: 이환된 추체에 척추경 나사 고정이 타당한가?)

  • Na, Hwa-Yeop;Jung, Yu-Hun;Lee, Joo-Young;Kim, Hyung-Do
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.5
    • /
    • pp.419-426
    • /
    • 2021
  • Purpose: In the surgical treatment of pyogenic lumbar spondylodiscitis, screw insertion at the affected vertebra has been avoided because of biofilm formation, and the risk of infection recurrence. The authors analyzed the success rate of infection treatment while minimizing the number of instrumented segments by inserting pedicle screws into the affected vertebrae. Therefore, this study examined the usefulness of this technique. Materials and Methods: From January 2000 to June 2018, among patients with pyogenic lumbar spondylodiscitis treated surgically, group A consisted of patients with pedicle screws inserted directly at the affected vertebrae (28 cases), and group B underwent fusion by inserting screws at the adjacent normal vertebrae due to bone destruction of the affected vertebral pedicle (20 cases). The classified clinical results were analyzed retrospectively. All patients were treated via the posterior-only approach, so the affected disc and sequestrum were removed. Posterior interbody fusion was performed with an autogenous strut bone graft, and the segments were then stabilized with pedicle screw systems. The hospitalization period, operation time, amount of blood loss, EQ-5D index, duration of intravenous antibiotics, and the clinical and radiological results were analyzed. Results: In group A, the number of instrumented segments, operation time, blood loss, and EQ-5D index at one month postoperatively showed significant improvement compared to group B. There were no significant differences in the duration of antibiotic use, hospitalization, radiological bone union time, sagittal angle correction rate, and recurrence rate. Conclusion: Minimal segmental fixation, in which pedicle screws were inserted directly into the affected vertebrae through the posterior approach, reduced the surgery time and blood loss, preserved the lumbar motion by minimizing fixed segments and showed rapid recovery without spreading or recurrence of infection. Therefore, this procedure recommended for the surgical treatment of lumbar pyogenic spondyodiscitis.

A Study on Setting SPS for Generator Tripping Action considering Operating Conditions of Power Systems (전력계통 운영조건을 고려한 발전기차단용 SPS 동작설정에 관한 연구)

  • Gwon, Han Na;Son, Hyeok Jin;Kook, Kyung Soo;Yang, Sung-Chae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.411-417
    • /
    • 2014
  • Special Protection Scheme(SPS) for generator tripping action is an emergency control tool that secures the power system stability by instantly tripping the pre-determined number of generators to avoid the acceleration of the remaining generators in a large-scaled power plants when a fault occurs on the drawing transmission lines. However, since the existing operating conditions of SPS are set based on a peak demand, SPS could trip more generators than required if it is activated during the off-peak demand period. For this, this paper proposes the algorithm for setting the operating conditions of SPS through the online stability evaluation with the periodically updated operating conditions of power systems. The proposed algorithm adopts COA for the accuracy and speed of the stability evaluation, and can reduce the number of tripping generators by SPS during the off-peak demand period. This results in reducing the loss of profit caused by a fault on power systems.

Experimental Results of New Ion Source for Performance Test

  • Kim, Tae-Seong;Jeong, Seung-Ho;Jang, Du-Hui;Lee, Gwang-Won;In, Sang-Yeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.269-269
    • /
    • 2012
  • A new ion source has been designed, fabricated, and installed at the NBTS (Neutral Beam Test Stand) at the KAERI (Korea Atomic Energy Research Institute) site. The goalis to provide a 100 keV, 2MW deuterium neutral beam injection as an auxiliary heating of KSTAR (Korea Super Tokamak Advanced Research). To cope with power demand, an ion current of 50 A is required considering the beam power loss and neutralization efficiency. The new ion source consists of a magnetic cusp bucket plasma generator and a set of tetrode accelerators with circular copper apertures. The plasma generator for the new ion source has the same design concept as the modified JAEA multi-cusp plasma generator for the KSTAR prototype ion source. The dimensions of the plasma generator are a cross section of $59{\times}25cm^2$ with a 32.5 cm depth. The anode has azimuthal arrays of Nd-Fe permanent magnets (3.4 kG at surface) in the bucket and an electron dump, which makes 9 cusp lines including the electron dump. The discharge properties were investigated preliminarily to enhance the efficiency of the beam extraction. The discharge of the new ion source was mainly controlled by a constant power mode of operation. The discharge of the plasma generator was initiated by the support of primary electrons emitted from the cathode, consisting of 12 tungsten filaments with a hair-pin type (diameter = 2.0 mm). The arc discharge of the new ion source was achieved easily up to an arc power of 80 kW (80 V/1000 A) with hydrogen gas. The 80 kW capacity seems sufficient for the arc power supply to attain the goal of arc efficiency (beam extracted current/discharge input power = 0.8 A/kW). The accelerator of the new ion source consists of four grids: plasma grid (G1), gradient grid (G2), suppressor grid (G3), and ground grid (G4). Each grid has 280 EA circular apertures. The performance tests of the new ion source accelerator were also finished including accelerator conditioning. A hydrogen ion beam was successfully extracted up to 100 keV /60 A. The optimum perveance is defined where the beam divergence is at a minimum was also investigated experimentally. The optimum hydrogen beam perveance is over $2.3{\mu}P$ at 60 keV, and the beam divergence angle is below $1.0^{\circ}$. Thus, the new ion source is expected to be capable of extracting more than a 5 MW deuterium ion beam power at 100 keV. This ion source can deliver ~2 MW of neutral beam power to KSTAR tokamak plasma for the 2012 campaign.

  • PDF

Assessment of Extreme Wind Risk for Window Systems in Apartment Buildings Based on Probabilistic Model (확률 모형 기반의 아파트 창호 시스템 강풍 위험도 평가)

  • Ham, Hee Jung;Yun, Woo-Seok;Choi, Seung Hun;Lee, Sungsu;Kim, Ho-Jeong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.6
    • /
    • pp.625-633
    • /
    • 2015
  • In this study, a coupled probabilistic framework is developed to assess wind risk on apartment buildings by using the convolution of wind hazard and fragility functions. In this framework, typhoon induced extreme wind is estimated by applying the developed Monte Carlo simulation model to the climatological data of typhoons affecting Korean peninsular from 1951 to 2013. The Monte Carlo simulation technique is also used to assess wind fragility function for 4 different damage states by comparing the probability distributions of the window system's resistance performance and wind load. Wind hazard and fragility functions are modeled by the Weibull and lognormal probability distributions based on simulated wind speeds and failure probabilities. The modeled functions are convoluted to obtain the wind risk for the different damage levels. The developed probabilistic framework clearly shows that wind risk are influenced by various important characteristics of terrain and apartment building such as location of building, exposure category, topographic condition, roof angle, height of building, etc. The risk model presented in this paper can be used as tools to predict economic loss estimation and to establish wind risk mitigation plan for the existing building inventory.

A study on the development of simulation program for the small naturally aspirated four-stroke diesel engine (소형 4행정사이클 무과급 디이젤 기관의 성능 시뮤레이션 전산프로그램의 개발에 관한 연구)

  • 백태주;전효중
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.17-36
    • /
    • 1984
  • Since 1973, the competition on the development of fuel saving type internal combustion engines has become severe by the two times oil shock, and new type engines are reported every several months. Whenever these new type engines are developed, new designs are required and they will be offered in the market after performing the endurance test for a long time. But the engine market is faced with a heavy burden of finance, as the developing of a new engine requires tremendous expenses. For this reason, the computer simulation method has been lately developed to cope with it. The computer simulation method can be available to perform the reasonable research works by the theoretical analysis before carrying out practical experiments. With these processes, the developing expenses are cut down and the period of development is curtailed. The object of this study is the development of simulation computer program for the small naturally aspirated four-stroke diesel engine which is intended to product by the original design of our country. The process of simulation is firstly investigated for the ideal engine cycle, and secondly for the real engine cycle. In the ideal engine cycle, each step of the cycle is simulated by the energy balance according to the first law of thermodynamics, and then the engine performance is calculated. In the real cycle imulation program, the injection rate, the preparation rate and the combustion rate of fuel and the heat transfer through the wall of combustion chamber are considered. In this case, the injection rate is supposed as constant through the crank angle interval of injection and the combustion rate is calculated by the Whitehouse-Way equation and the heat transfer is calculated by the Annand's equation. The simulated values are compared with measured values of the YANMAR NS90(C) engine and Mitsubishi 4D30 engine, and the following conclusions are drawn. 1. The heat loss by the exhaust gas is well agree with each other in the lower load, but the measured value is greater than the calculated value in the higher load. The maximum error rate is about 15% in the full load. 2. The calculated quantity of heat transfer to the cooling water is greater than the measured value. The maximum error rate is about 11.8%. 3. The mean effective pressure, the fuel consumption, the power and the torque are well agree with each other. The maximum error is occurred in the fuel consumption, and its error rate is about 7%. From the above remarks, it may be concluded that the prediction of the engine performance is possibly by using the developed program, although the program needs to reform by adding the simulation of intake and exhaust process and assumping more reliable mechanical efficiency, volumetric efficiency, preparation rate and combustion rate.

  • PDF

A STUDY ON STRESS DISTRIBUTION OF ENDODONTICALLY TREATED TOOTH ACCORDING TO THE VARIOUS POST LENGTH USINGTHREE-DIMENSIONAL FINITE ELEMENT METHOD (포스트 길이가 치근내 응력분산에 미치는 영향에 관한 삼차원 유한요소법적 연구)

  • Choi, Soo-Yong;Lee, Sun-Hyung;Yang, Jae-Ho;Chung, Hun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.2
    • /
    • pp.177-197
    • /
    • 1995
  • The endodontically treated tooth is generally restored with post & core, owing to the brittleness and the loss of large amount of tooth structure. Although there have been lots of studies about the endodontically treated teeth, the three-dimensional quantitative studies about the strees distribution of them are in rare cases. In this study, it was assumed that the coronal portion of the upper incisou had severely damaged. After the root canal therapy it was post cored, and restored with PFM crown, for this experiment nine types of model were constructed : 1); long, 2); medium, 3); short gold post for the roots supported with a narmal alveolar bone, 4); long, 5); medium, 6); short gold post for the roots supported with an alveolar bone resorbed to its 1/3 of root length, 7); long, 8); medium, 9); short base metal post for the roots supported with an alveolar bone resorbed to its 1/3 of root length. Force was applied from two directions. One was functional maximum bite force(300N) applied to the spot just lingual to the incisal edge with the angle of 45 degrees to the long axis of the tooth, and the other one was horizontal force(300N) applied to the labial surface. The results analyzed with three-dimensional finite element method were as follows : 1. Stress was concentrated on the middle portion of the labial side dentin of the root and the lingual portion of the apical dentin of the root. Stress in the post showed maximum value at 2 mm above the post apex. 2. In case of the long post and base metal post, strees was concentrated on the apex of the root and the post. 3. In case of the longer post, the displacement on the post-cement interface was lessened. The gold post was more displaceable than the base metal post. 4. In case of the alveolar bone resorption, stress concentrated on the root and the post and displacement on the post-cement interface were increased.

  • PDF

Miniaturization of Circular Microstrip Antenna Using the Perturbation Effect (Perturbation 효과를 이용한 원형 마이크로스트립 안테나의 소형화)

  • Ryu Mi-Ra;Hur Jung;Woo Jong-Myung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.7 s.110
    • /
    • pp.605-614
    • /
    • 2006
  • In this paper, a 3D structure skimmer-shaped circular microstrip antenna is designed, the ends of whose both sides are made as DC(Depressed Carving part) applying perturbation effect to reduce the patch size of microstrip antenna operating at design frequency 1.575 GHz. The result shows its return loss, - 10 dB bandwidth, gain, - 3 dB beamwidth E, H-plane are -26.59 dB, 65 MHz(4.13 %), 4.66 dBd, $79^{\circ},\;87^{\circ}$ respectively. The diameter of the antenna is 85 mm, which is 12.4 % reduced compared to the size(97 mm) of general microstrip patch antenna. Therefore its area reduction is 23.2 %. Furthermore, a linear and circular polarized baseball-shaped circular microstrip antenna is designed to minimize the patch size of the antenna. This structure of antenna operating at the design frequency 1.575 GHz is applied with the optimum RC(Raised Carving part) & DC ratio and an asymptotic line angle. In case of linear polarized baseball-shaped circular microstrip antenna, the patch size of the antenna is 74 mm, which is 41.8 % area reduction compared to general microstrip patch antenna. In case of circular polarized baseball-shaped circular microstrip antenna, the diameter of patch is 82 mm, which is 28.5 % area reduction compare to general microstrip patch antenna linear polarized. We have verified that the perturbation effect can be applied to minimize the circular microstrip antenna.