• Title/Summary/Keyword: loosening

Search Result 471, Processing Time 0.024 seconds

Finite element analysis of the effect of novel Lock Screw system preventing abutment screw loosening (지대주 나사 풀림 방지를 위한 새로운 Lock Screw 시스템의 효과에 대한 유한요소해석적 연구)

  • Im, Eun Sub;Kim, Jong Eun;Kim, Jee Hwan;Park, Young Bum
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.3
    • /
    • pp.132-142
    • /
    • 2019
  • Purpose: The purpose of this finite element analysis study is to introduce the novel Lock screw system and analyze its mechanical property to see if it can prevent abutment screw loosening. Materials and Methods: The Lock screw is a component tightened on the inside of the implant abutment which applies compressive force to the abutment screw head. To investigate the effect, modeling was done using CAD program and it was analyzed by finite element analysis under various load conditions. First, the preload was measured according to the tightening torque of the abutment screw then it was compared with the theoretical value to verify the analytical model. The validated analytical model was then divided into those with no external load and those with 178 N, and the tightening torque of the lock screw was changed to 10, 20, 30 Ncm respectively to examine the property of stress distribution on the implant components. Results: Using Lock screw under various loading conditions did not produce equivalent stresses beyond the yield strength of the implant components. In addition, the axial load was increased at the abutment-abutment screw interface. Conclusion: The use of Lock screw does not exert excessive stress on the implant components and may increase the frictional force between the abutment-abutment screw interface, thus it is considered to prevent loosening of the abutment screw.

Comparison of the torque stability of Implant Torque Controllers

  • Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Korean Dental Science
    • /
    • v.2 no.1
    • /
    • pp.19-27
    • /
    • 2009
  • Tightening of the screws in implant restorations should be accurate and precise. If applied torque is too low, screw loosening would be occurred. With too high torque, the screw fracture might take place. Various torque generating devices are developed and employed to apply a proper torque. The purpose of this investigation was to determine and compare the accuracy of the torque controllers. In this study, 4 types of torque controllers were used; electronic torque controller, torque limiting device, torque indicating device and contra angle torque driver. Digital torque gauge was employed to measure the de-torque value. Thirty cycles of tightening and loosening were done with each torque controller. All implant torque controllers have shown slight errors and deviations. The torque liming device exhibited the most accurate data. No significant difference was found among the mean de-torque values of the electronic torque controller, torque indicating device and contra angle torque driver. In the limitation of this study, it would be recommended that the implant torque controllers should be checked whether uniformed and precise torque can be generated and a measuring error should be corrected.

  • PDF

Dyeing of Wool at Low Temperature - focusing on solubility parameter$(\delta)$ - (양모의 저온 염색(1) - 용해도 파라미터$(\delta)$를 중심으로 -)

  • 도성국
    • Textile Coloration and Finishing
    • /
    • v.15 no.6
    • /
    • pp.55-62
    • /
    • 2003
  • Wool fabrics were dyed with the aqueous solution of C. I. Red Acid 114 mixed with methanol dissolving three kinds of barely water soluble ketones, acetophenone, 2-pentanone, and 3-pentanone. The steric hinderance and the orientation of the bigger hydrophobic part of the solvated dye molecules to the fiber slowed down the dying rate, however, loosening the wool molecule, say a little swelling, disaggeregating the dye molecules, and attaining the higher dye concentration on the fiber surface by the added solvents increased the amount of dye on the fabric. The higher concentration or/and the higher dyeing temperature helped loosen fiber molecules and made it easier for the solvated dye molecules to penetrate into the inside of the fiber. Acetophenone, the most influential solvent used, showed that the ability to loosen fiber molecules was the most important of all the three positive solvent actions mentioned above. The considered mechanism provided before reflected the fact that the dye uptake on the fabric dyed with the solvents included, except for 0.034M and 0.051M of acetophenone, was even lower than that without any solvents at $50^\circ{C}$, but all the solvents added to the dye bath increased the dye uptake on the fiber at $70^\circ{C}$.

Behavior of shallow 2-Arch tunnel due to excavation under horizontal discontinuity plane (수평 불연속변 하부에 굴착한 얄은 심도의 2-Arch 터널의 거동)

  • Cheon, Eun-Sook;Kim, Hong-Moon;Lee, Sang-Duk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.7 no.3
    • /
    • pp.227-237
    • /
    • 2005
  • In this study, the behavior of shallow 2-Arch tunnel due to excavation under horizontal discontinuity plane was verified experimentally. The model tests were carried out by varying the overburden height and the location of the discontinuity plane. The model tests followed exactly the real 2-Arch tunnel construction stages. As a result, it is discovered that stress-transfer mechanism and loosening area around the 2-Arch tunnel depends on the overburden heights and the location of the discontinuity plane. And central pillar load is also dependent on overburden height, location of discontinuity plane and construction stages.

  • PDF

Creep-Induced Tension Loosening of CRT Tension Mask (크리프에 따른 CRT 텐션 마스크의 장력 이완)

  • Chung, Il-Sup
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.6
    • /
    • pp.1034-1040
    • /
    • 2003
  • Tension mask is a part of CRT type devices, which is installed right behind glass-made front panel. Numerous slits on the thin metal sheet enable the electron beams emitted from posterior gun to be focused, resulting in enhanced definition. Flattened and enlarged displays necessitate the imposition of pretension on the masks, in order to improve the robustness of display quality against vibration or impact. High temperature assembly process subsequent to pretensioning, however, degenerates creep resistance of mask material, and common mask may become susceptible to undesirable elongation due to creep. Once tensile stress becomes high enough to induce creep deformation, pretension is substantially loosened. In this study, tension mask assembly is modeled as a combined structure of beams and wire array, and a numerical simulation is attempted for pretensioning followed by high temperature process. Based on a model study, creep occurrence is found to be probable and its adverse influence is quantified. As fur maintaining high tensile force, simply increasing pretension does not seem to be helpful. Instead, the structure of frame needs to be modified somehow, or material for mask needs to be selected properly.

Total elbow arthroplasty for posttraumatic destroyed or unreduced elbow joint (외상 후 파괴된 주관절 또는 진구성 탈구에서의 주관절 전치환술)

  • Kim, Young-Kyu;Jung, Lee-Hyuk
    • Clinics in Shoulder and Elbow
    • /
    • v.6 no.1
    • /
    • pp.37-43
    • /
    • 2003
  • Purpose: To evaluate the results in patients who received total elbow replacement for posttraumatic destroyed or unreduced elbow joint. Materials and Methods: Six patients with posttraumatic destroyed, or unreduced elbow joint, who were nearly impossible to move actively and had pain and grossly unstable joint, were followed up average 42 months. 3 cases were soft tissue injuries and bone defects which were caused by severe comminuted fracture, 1 was a nonunion with comminuted fracture, and 2 were unreduced elbow joint. Total elbow replacement was performed average 10 months after the injury. All the cases were used by semiconstrained prosthesis, and the results were estimated by Mayo elbow perfomance score. Results: Pain was decreased in all the cases postoperatively. Average ranges of motion were improved with active extension 20° and flexion 120°. Mayo elbow performance scores were pain 42.5 points, range of motion 17.5 points, stability 8.3 points, function 19.2 points and totally 87.5 points, and final results were 3 excellent and 3 good. Loosening of prosthesis was not found in all the cases by final follow-up radiograph. Conclusicon: Semiconstrained TER can be used as a effective treatment improving pain and active ranges of motion caused by posttraumatic destroyed or unreduced elbow joint, however, long term follow-up is needed because early loosening of TER can be occurred due to severe bone defects.

Hybrid bolt-loosening detection in wind turbine tower structures by vibration and impedance responses

  • Nguyen, Tuan-Cuong;Huynh, Thanh-Canh;Yi, Jin-Hak;Kim, Jeong-Tae
    • Wind and Structures
    • /
    • v.24 no.4
    • /
    • pp.385-403
    • /
    • 2017
  • In recent years, the wind energy has played an increasingly important role in national energy sector of many countries. To harvest more electric power, the wind turbine (WT) tower structure becomes physically larger, which may cause more risks during long-term operation. Associated with the great development of WT projects, the number of accidents related to large-scaled WT has also been increased. Therefore, a structural health monitoring (SHM) system for WT structures is needed to ensure their safety and serviceability during operational time. The objective of this study is to develop a hybrid damage detection method for WT tower structures by measuring vibration and impedance responses. To achieve the objective, the following approaches are implemented. Firstly, a hybrid damage detection scheme which combines vibration-based and impedance-based methods is proposed as a sequential process in three stages. Secondly, a series of vibration and impedance tests are conducted on a lab-scaled model of the WT structure in which a set of bolt-loosening cases is simulated for the segmental joints. Finally, the feasibility of the proposed hybrid damage detection method is experimentally evaluated via its performance during the damage detection process in the tested model.

Analytical investigation on moment-rotation relationship of through-tenon joints with looseness in ancient timber buildings

  • Xue, Jianyang;Qi, Liangjie;Dong, Jinshuang;Xu, Dan
    • Earthquakes and Structures
    • /
    • v.14 no.3
    • /
    • pp.241-248
    • /
    • 2018
  • To study the mechanical properties of joints in ancient timber buildings in depth, the force mechanism of the through-tenon joints was analyzed, also the theoretical formulas of the moment-rotation angles of the joints with different loosening degrees were deduced. To validate the rationality of the theoretical calculation formulas, six joint models with 1/3.2 scale ratio, including one intact joint and five loosening joints, were fabricated and tested under cyclic loading. The specimens underwent the elastic stage, the plastic stage and the destructive stage, respectively. At the same time, the moment-rotation backbone curves of the tenon joints with different looseness were obtained, and the theoretical calculation results were validated when compared with the experimental results. The results show that the rotational moment and the initial rotational stiffness of the tenon joints increase gradually with the increase of the friction coefficient. The increase of the tenon section height can effectively improve the bearing capacity of the through-tenon joints. As the friction coefficient of the wood and the insertion length of the tension increase, the embedment length goes up, whereas it decreases with the increase of section height. With the increase of the looseness, the bearing capacity of the joint is reduced gradually.

Abrasion of abutment screw coated with TiN

  • Jung, Seok-Won;Son, Mee-Kyoung;Chung, Chae-Heon;Kim, Hee-Jung
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.2
    • /
    • pp.102-106
    • /
    • 2009
  • STATEMENT OF PROBLEM. Screw loosening has been a common complication and still reported frequently. PURPOSE. The purpose of this study was to evaluate abrasion of the implant fixture and TiN coated abutment screw after repeated delivery and removal with universal measuring microscope. MATERIAL AND METHODS. Implant systems used for this study were Osstem and 3i. Seven pairs of implant fixtures, abutments and abutment screws for each system were selected and all the fixtures were perpendicularly mounted in liquid unsaturated poly-esther with dental surveyor. After 20 times of repeated closing and opening test, the evaluation for the change of inner surface of implant and TiN-coated abutment screw, and weight loss were measured. Mann-Whitney test with SPSS statistical software for Window was applied to analyze the measurement of weight loss. RESULTS. TiN-coated abutment screws of Osstem and 3i showed lesser loss of weight than non-coated those of Osstem and 3i (P < .05, Mann-Whitney test). CONCLUSION. Conclusively, TiN coating of abutment screw showed better resistance to abrasion than titanium abutment screw. It was concluded that TiN coating of abutment screw would reduce the loss of preload with good abrasion resistance and low coefficient of friction, and help to maintain screw joint stability.