• 제목/요약/키워드: longitudinal direction

Search Result 819, Processing Time 0.032 seconds

Effectiveness of the Respiratory Gating System for Stereotectic Radiosurgery of Lung Cancer (폐암 환자의 정위적 방사선 수술 시 Respiratory Gating System의 유용성에 대한 연구)

  • Song Heung-Kwon;Kwon Kyung-Tae;Park Cheol-Su;Yang Oh-Nam;Kim Min-Su;Kim Jeong-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.125-131
    • /
    • 2005
  • Purpose : For stereotactic radiosurgery (SRS) of a tumor in the region whose movement due to respiration is significant, like Lung lower lobe, the gated therapy, which delivers radiation dose to the selected respiratory phases when tumor motion is small, was performed using the Respiratory gating system and its clinical effectiveness was evaluated. Materials and Methods : For two SRS patients with a tumor in Lung lower lobe, a marker block (infrared reflector) was attached on the abdomen. While patient' respiratory cycle was monitored with Real-time Position Management (RPM, Varian, USA), 4D CT was performed (10 phases per a cycle). Phases in which tumor motion did not change rapidly were decided as treatment phases. The treatment volume was contoured on the CT images for selected treatment phases using maximum intensity projection (MIP) method. In order to verify setup reproducibility and positional variation, 4D CT was repeated. Results : Gross tumor volume (GTV) showed maximum movement in superior-inferior direction. For patient #1, motion of GTV was reduced to 2.6 mm in treatment phases ($30{\sim}60%$), while that was 9.4 mm in full phases ($0{\sim}90%$) and for patient #2, it was reduced to 2.3 mm in treatment phases ($30{\sim}70%$), while it was 11.7 mm in full phases ($0{\sim}90%$). When comparing two sets of CT images, setup errors in all the directions were within 3 mm. Conclusion : Since tumor motion was reduced less than 5 mm, the Respiratory gating system for SRS of Lung lower lobe is useful.

  • PDF

Geochemical Exploration for Tri Le REE Occurrence in Nghe An Province within Northern Vietnam (베트남 북부 네안성 칠레 희토류 산출지의 지구화학탐사)

  • Heo, Chul-Ho;Ho, Tien Chung;Lee, Jae-Ho
    • Economic and Environmental Geology
    • /
    • v.47 no.2
    • /
    • pp.147-168
    • /
    • 2014
  • The soil geochemical exploration was carried out targeting around Tri Le area far from about 30 km with northwestern direction from Que Phong within Nghe An province. The interval of sampling are horizontal 200 m interval with 23 line and longitudinal 300 m with 10 line, resulting in 228 soil samples. Based on the result of the soil geochemical exploration, the detailed pitting survey was carried out targeting the grid point with high TREO content, resulting in 75 soil samples within 7 pits. The geology of survey area are consisted of Ban Chieng biotite granite complex and granitic gneiss intruding Ban Khang formation comprising of quartz schist and marble. Main mineralization in the study area have the characteristics of occurrence with tin, ruby and REE-bearing monazite and xenotime to be thought as occurring at the alteration zone of granite complex. In order to elucidate the source rock of monazite and xenotime confirmed from heavy sand, soil geochemical exploration was carried out. As a analysis result with ICP-MS on the soil samples from the soil geochemical exploration, total REE oxide content of background amount to about 2 times of crustal abundance, enriching the heavy rare earth(about 2 times) and light rare earth(about 1.5 times). As a analysis result with ICP-MS on the soil samples from the soil detailed pit survey, we only identified outcrop considering as economic weathered granite body at the grid point 1-10 pit among 7 pits. As a synthetic consideration on the soil geochemical exploration and detailed pit survey, we tentatively designated Tri Le area as no promising target for REE. In 2014, we have the plan to carry out the soil geochemical exploration targeting the extended economic REE ore body in Quy Chau as project area from 2011 to 2012.

Development of Two-dimensional Prompt-gamma Measurement System for Verification of Proton Dose Distribution (이차원 양성자 선량 분포 확인을 위한 즉발감마선 이차원분포 측정 장치 개발)

  • Park, Jong Hoon;Lee, Han Rim;Kim, Chan Hyeong;Kim, Sung Hun;Kim, Seonghoon;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.42-51
    • /
    • 2015
  • In proton therapy, verification of proton dose distribution is important to treat cancer precisely and to enhance patients' safety. To verify proton dose distribution, in a previous study, our team incorporated a vertically-aligned one-dimensional array detection system. We measured 2D prompt-gamma distribution moving the developed detection system in the longitudinal direction and verified similarity between 2D prompt-gamma distribution and 2D proton dose distribution. In the present, we have developed two-dimension prompt-gamma measurement system consisted of a 2D parallel-hole collimator, 2D array-type NaI(Tl) scintillators, and multi-anode PMT (MA-PMT) to measure 2D prompt-gamma distribution in real time. The developed measurement system was tested with $^{22}Na$ (0.511 and 1.275 MeV) and $^{137}Cs$ (0.662 MeV) gamma sources, and the energy resolutions of 0.511, 0.662 and 1.275 MeV were $10.9%{\pm}0.23p%$, $9.8%{\pm}0.18p%$ and $6.4%{\pm}0.24p%$, respectively. Further, the energy resolution of the high gamma energy (3.416 MeV) of double escape peak from Am-Be source was $11.4%{\pm}3.6p%$. To estimate the performance of the developed measurement system, we measured 2D prompt-gamma distribution generated by PMMA phantom irradiated with 45 MeV proton beam of 0.5 nA. As a result of comparing a EBT film result, 2D prompt-gamma distribution measured for $9{\times}10^9$ protons is similar to 2D proton dose distribution. In addition, the 45 MeV estimated beam range by profile distribution of 2D prompt gamma distribution was $17.0{\pm}0.4mm$ and was intimately related with the proton beam range of 17.4 mm.

Introduction and feasibility study of the HD-270 MLC (HD-270 MLC의 소개 및 유용성평가)

  • Kim Dae Young;Kim Won Taek;Lee Hwa Jung;Lee Kang Hyeok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.1-9
    • /
    • 2003
  • I. Purpose The multileaf collimator(MLC) has many advantages, but use of the MLC increased effective penumbra and isodose undulation in dose distribution compared with that of an alloy block. In this work, we introduced the HD-270 MLC, which can improve the above disadvantages of MLC, and reported its feasibility study. II. Method and Materials The HD-270 MLC is a technique which combines the use of the existing Siemens multileaf collimator(3D MLC) with patient translation perpendicular to the leaf plane. The technique produces a smoothed isodose distribution with the reduced isodose undulation and effective penumbra. To assess the efficacy of the HD-270 technique and determine the appropriate resolution, a polygonal shaped MLC field was made to produce field edge angles from 0 degree to 75 degree with a step of 15 degree. Each HD-270 group was generated according to the allowed resolution, i. e., 5, 3, and 2mm. The experiment was carried out on Primus, a Siemens linear accelerator configured with HD-270 MLC. The total 60 MU of 6 MV photon beam was delivered to X-Omat film(Kodak, USA) at a SAD of 100 cm and 1.5 cm depth in solid water phantom. Exposed films were scanned by Lumiscan75(LUMISYS) and analyzed using RIT113 software(Radiological Imaging Technology Inc., USA). To test the mechanical accuracy of table movement, the transverse, longitudinal, and vertical positions were controlled by a consol with ${\pm}5\;mm,\;{\pm}4\;mm,\;{\pm}3\;mm,\;and\;{\pm}2\;mm$ steps, and then measured using a dial gauge with an accuracy of 0.001 inch. During the experiments, the table loaded with about 50Kg human phantom to simulate the real treatment situation. III. Results The effective penumbra and isodose undulation became larger with increase the resolution and field edge angle. The accuracy of the table movement on each direction is good within the ${\pm}1\;mm$. IV. Conclusion Clinical use of the MLC can be increased by using of the HD-270 MLC which complements to the disadvantages of the MLC.

  • PDF

A Trend of Research in Community Health Nursing (지역사회간호학 관련 논문 연구동향 분석 -학회지 발표 논문을 중심으로-)

  • Lee, In-Sook;Kim, Yu-Na;Choi, Key-Won;Chin, Young-Ran
    • Research in Community and Public Health Nursing
    • /
    • v.12 no.1
    • /
    • pp.288-298
    • /
    • 2001
  • This article makes an attempt to evaluate the extent of developing community health nursing knowledge and to suggest the direction of developing a body of knowledge henceforth through the results of analysis for contents and outcomes of all literatures. which have been published in the Journal related to community health nursing. Refer to the following for the result of this article. 1. The total number of literatures analyzed amounted to 100 pieces in Journal of community health nursing society. 78 in Journal of industrial nursing society, 134 in Journal of school health society. 40 in Journal of home care nursing society. 2. Journal of community health nursing society Health needs and educational-behavioral diagnoses, which are more concrete nursing assessments and diagnoses. formed the main current(54%) of articles published in Journal of community health nursing society since 1992. There was a quantitative growth as well as a qualitative advance. Through a classification by the type of a body of knowledge. It was found that the knowledge providing nursing practice with bases, commanded an overwhelming majority(71.8%). Also, Researches on systemic supports for nursing practice are showing a tendency to increase. 3. Journal of industrial nursing society 52.6% of research papers presented in Journal of industrial nursing society dealt with health problem of workers. assessment of risk factors, diagnosis of health behaviors. Because of the beginning of an industrial nursing, the domain of nursing management to establish the role and task, work condition, training. documentary system made up 23 percent of research, subjects. A knowledge providing nursing practice with bases have a majority, 69.2%. In addition. the subject concerning a systemic support and quality assurance was scarce but continuously presented. 4. Journal of school health society The major point of this journal is the identification of health problems and risk factors which belong to assessment and diagnosis domain(56.8%) regardless of year, Because of the interdisciplinary characteristic. The knowledge on quality assurance of nursing practice is relatively rare. But, articles related to a systemic support is plentiful. 5. Journal of home care nursing society In its infancy, there was a large number of papers concerning need assessment and diagnosis, Comparing others, this journal has introduced a good many of articles related to program management. delivery system. service fee, etc that belong to domain of systemic support for nursing practice. 6. It is showing definitely that quantity and extent of research have grown for a short period. See the analysis in terms of nursing process, studies related to the domain of assessment and diagnosis command an absolute majority regardless of kinds of journal. Although articles referring to program management and implementation is increasing in number, it is scarce to evaluate a nursing program and grope for an improvement. Also, program development based on a theoretical framework is little. Therefore much more scientific effort to ensure profession should be executed. 7. In the methodological aspect, longitudinal study needs to be carried out so that we could show the evidence based nursing theory. To develop a more general theory, we have to conduct a study of various subjects and improve a validity of tools through a repeat test. In addition, the effort for interdisciplinary cooperation is needed.

  • PDF

Failure Behavior and Separation Criterion for Strengthened Concrete Members with Steel Plates (강판과 콘크리트 접착계면의 파괴거동 및 박리특성)

  • 오병환;조재열;차수원
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.1
    • /
    • pp.126-135
    • /
    • 2002
  • Plate bonding technique has been widely used in strengthening of existing concrete structures, although it has often a serious problem of premature falure such as interface separation and rip-off. However, this premature failure problem has not been well explored yet especially in view of local failure mechanism around the interface of plate ends. The purpose of the present study is, therefore, to identify the local failure of strengthened plates and to derive a separation criterion at the interface of plates. To this end, a comprehensive experimental program has been set up. The double lap pull-out tests considering pure shear force and half beam tests considering combined flexure-shear force were performed. The main experimental parameters include plate thickness, adhesive thickness, and plate end arrangement. The strains along the longitudinal direction of steel plates have been measured and the shear stress were calculated from those measures strains. The effects of plate thickness, bonded length, and plate end treatment have been also clarified from the present test results. Nonlinear finite element analysis has been performed and compared with test results. The Interface properties are also modeled to present the separation failure behavior of strengthened members. The cracking patterns as well as maximum failure loads agree well with test data. The relation between maximum shear and normal stresses at the interface has been derived to propose a separation failure criterion of strengthened members. The present study allows more realistic analysis and design of externally strengthened flexural member with steel plates.

CROSS-SECTIONAL MORPHOLOGY AND MINIMUM CANAL WALL WIDTHS IN C-SHAPED ROOT OF MANDIBULAR MOLARS (C-shaped canal의 절단면 분석을 통한 근관형태의 변화와 근관과 치아외벽간의 최소거리 분석에 관한 연구)

  • Song, Byung-Chul;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.1
    • /
    • pp.37-46
    • /
    • 2007
  • The C-shaped canal system is an anatomical variation mostly seen in mandibular second molars, although it can also occur in maxillary and other mandibular molars. The main anatomical feature of C-shaped canals is the presence of fins or web connecting the individual root canals. The complexity of C-shaped canals prevents these canals from being cleaned, shaped, and obturated effectively during root canal therapy, and sometimes it leads to an iatrogenic perforation from the extravagant preparation. The purpose of this study was to provide further knowledge of the anatomical configuration and the minimal thickness of dentinal wall according to the level of the root. Thirty extracted mandibular second molars with fused roots and longitudinal grooves on lingual or buccal surface of the root were collected from a native Korean population. The photo images and radiographs from buccal, lingual, apical direction were taken. After access cavity was prepared, teeth were placed in 5.25% sodium hypochlorite solution for 2 hours to dissolve the organic tissue of the root surface and from the root canal system. After bench dried and all the teeth were embedded in a self-curing resin. Each block was sectioned using a microtome (Accutom-50, Struers, Denmark) at interval of 1 mm. The sectioned surface photograph was taken using a digital camera (Coolpix 995, Nikon, Japan) connected to the microscope. 197 images were evaluated for canal configurations and the minimal thickness of dentinal wall between canal and external wall using 'Root Thickness Gauge Program' designed with Visual Basic. The results were as follows : 1. At the orifice level of all teeth, the most frequent observed configuration was Melton's Type C I (73%), however the patterns were changed to type C II and C III when the sections were observed at the apical third. On the other hand, the type C III was observed at the orifice level of only 2 teeth but this type could be seen at apical region of the rest of the teeth. 2. The C-shaped canal showed continuous and semi-colon shape at the orifice level, but at the apical portion of the canal there was high possibility of having 2 or 3 canals 3. Lingual wall was thinner than buccal wall at coronal, middle, apical thirds of root but there was no statistical differences.

Correlation Analysis between Damage of Expansion Joints and Response of Deck in RC Slab Bridges (RC 슬래브교의 신축이음 손상과 바닥판 응답과의 상관관계 분석)

  • Jung, Hyun-Jin;An, Hyo-Joon;Park, Ki-Tae;Jung, Kyu-San;Kim, Yu-Hee;Lee, Jong-Han
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.245-253
    • /
    • 2021
  • RC slab bridges account for the largest portion of deteriorated bridges in Korea. However, most RC slabs are not included in the first and second classes of bridges, which are subject to bridge safety management and maintenance. The highest damaged components in highway bridges are the subsidiary facilities including expansion joints and bearings. In particular, leakage through expansion joints causes deterioration and cracks of concrete and exposure of reinforced bars. Therefore, this study analyzed the effect of adhesion damage at expansion joints on the response of the deck in RC slab bridges. When the spacing between the expansion joints at both ends was closely adhered, cracks occurred in the concrete at both ends of the deck due to the resistance rigidity at the expansion joints. Based on the response results, the correlation analysis between displacements in the longitudinal direction of the expansion joint and concrete stress at both ends of the deck for each damage scenario was performed to investigate the effect of the occurrence of damage on the bridge behavior. When expansion joint devices at both sides were damaged, the correlation between displacement and stress showed a low correlation of 0.18 when the vehicles proceeded along all the lanes. Compared with those in the intact state, the deflections of the deck in the damaged case at both sides showed a low correlation of 0.34 to 0.53 while the vehicle passed and 0.17 to 0.43 after the vehicle passed. This means that the occurrence of cracks in the ends of concrete changed the behavior of the deck. Therefore, data-deriven damage detection could be developed to manage the damage to expansion joints that cause damage and deterioration of the deck.

Changes in blood pressure and determinants of blood pressure level and change in Korean adolescents (성장기 청소년의 혈압변화와 결정요인)

  • Suh, Il;Nam, Chung-Mo;Jee, Sun-Ha;Kim, Suk-Il;Kim, Young-Ok;Kim, Sung-Soon;Shim, Won-Heum;Kim, Chun-Bae;Lee, Kang-Hee;Ha, Jong-Won;Kang, Hyung-Gon;Oh, Kyung-Won
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.2 s.57
    • /
    • pp.308-326
    • /
    • 1997
  • Many studies have led to the notion that essential hypertension in adults is the result of a process that starts early in life: investigation of blood pressure(BP) in children and adolescents can therefore contribute to knowledge of the etiology of the condition. A unique longitudinal study on BP in Korea, known as Kangwha Children's Blood Pressure(KCBP) Study was initiated in 1986 to investigate changes in BP in children. This study is a part of the KCBP study. The purposes of this study are to show changes in BP and to determine factors affecting to BP level and change in Korean adolescents during age period 12 to 16 years. A total of 710 students(335 males, 375 females) who were in the first grade at junior high school(12 years old) in 1992 in Kangwha County, Korea have been followed to measure BP and related factors(anthropometric, serologic and dietary factors) annually up to 1996. A total of 562 students(242 males, 320 females) completed all five annual examinations. The main results are as follows: 1. For males, mean systolic and diastolic BP at age 12 and 16 years old were 108.7 mmHg and 118.1 mmHg(systolic), and 69.5 mmHg and 73.4 mmHg(diastolic), respectively. BP level was the highest when students were at 15 years old. For females, mean systolic and diastolic BP at age 12 and 16 years were 114.4 mmHg and 113.5 mmHg(systolic) and 75.2 mmHg and 72.1 mmHg(diastolic), respectively. BP level reached the highest point when they were 13-14 years old. 2. Anthropometric variables(height, weight and body mass index, etc) increased constantly during the study period for males. However, the rate of increase was decreased for females after age 15 years. Serum total cholesterol decreased and triglyceride increased according to age for males, but they did not show any significant trend fer females. Total fat intake increased at age 16 years compared with that at age 14 years. Compositions of carbohydrate, protein and fat among total energy intake were 66.2:12.0:19.4, 64.1:12.1:21.8 at age 14 and 16 years, respectively. 3. Most of anthropometric measures, especially, height, body mass index(BMI) and triceps skinfold thickness showed a significant correlation with BP level in both sexes. When BMI was adjusted, serum total cholesterol showed a significant negative correlation with systolic BP at age 12 years in males, but at age 14 years the direction of correlation changed to positive. In females serum total cholesterol was negatively correlated with diastolic BP at age 15 and 16 years. Triglyceride and creatinine showed positive correlation with systolic and diastolic BP in males, but they did not show any correlation in females. There was no consistent findings between nutrient intake and BP level. However, protein intake correlated positively with diastolic BP level in males. 4. Blood pressure change was positively associated with changes in BMI and serum total cholesterol in both sexes. Change in creatinine was associated with BP change positively in males and negatively in females. Students whose sodium intake was high showed higher systolic and diastolic BP in males, and students whose total fat intake was high maintained lower level of BP in females. The major determinants on BP change was BMI in both sexes.

  • PDF