• Title/Summary/Keyword: long tooth

Search Result 395, Processing Time 0.023 seconds

A SCANNING ELECTRON MICROSCOPIC STUDY OF BONDING ASPECTS TO THE SCLEROTIC DENTIN (경화된 상아질의 접합 양상에 관한 주사전자현미경적 연구)

  • Lee, Rin;Lee, Hyeong-Il;Lee, Kwang-Won;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.228-243
    • /
    • 1997
  • The changes of microstructures, morphology of sclerotic dentin and bonding aspects generated by an adhesive resin was investigated. Incisors and premolars showing natural cervical abrasions were collected and conditioned with 10 % phosphoric acid or 10 % maleic acid. The sclerotic dentin specimens were then rinsed and blot-dried and applied with dentin adhesive (All Bond 2) to the conditioned dentin surface. To examine the morphologic change of the sclerotic dentin specimen after etching and bonding procedure, the treated specimens were examined by SEM. To analyze the chemical composition of sclerotic dentin and crystals occluding dentinal tubules, the sclerotic dentin specimen was powdered and examined with X-ray Diffractometer. To investigate the Ca/P weight percent ratio within the dentinal tubules, the sclerotic dentin specimen was fractured perpendicularly to the long axis of the tooth from the center of cervical abrasion lesion and then examined with EDX(Energy Dispersive X-ray) microanalyzer. The results were as follows : 1. The increased width of peritubular dentin and the depositions of the irregular amorphous materials within the dentinal tubules were showed in the sclerotic dentin specimens. 2. After the treatment of sclerotic dentin specimen with 10 % phosphoric acid or 10 % maleic acid, the lateral side of tubules rather than cross-sectional tubule openings was showed exclusively at the incisal and gingival incline of the specimens. 3. After the treatment of sclerotic dentin specimen with 10 % phosphoric acid or 10 % maleic acid, the hybrid layer was not formed evidently and the resin tag was not formed or shortly penetrated into the tubules with the thinner diameter. 4. According to the results of XRD analysis of the sclerotic dentin specimen, Hydroxyapatite and Octacalcium phosphate were predominent, however, Whitlockite crystals were rare. 5. The mean Ca/P weight percent ratio analysed from 5 fractured sclerotic dentin specimens was $2.322{\pm}0.170$ at the intertubular dentin, $1.826{\pm}0.051$ within the dentinal tubule.

  • PDF

The thickness of alveolar bone at the maxillary canine and premolar teeth in normal occlusion

  • Jin, Seong-Ho;Park, Jun-Beom;Kim, Namryang;Park, Seojin;Kim, Kyung Jae;Kim, Yoonji;Kook, Yoon-Ah;Ko, Youngkyung
    • Journal of Periodontal and Implant Science
    • /
    • v.42 no.5
    • /
    • pp.173-178
    • /
    • 2012
  • Purpose: The main purpose of this study was to investigate bone thickness on the buccal and palatal aspects of the maxillary canine and premolars using cone-beam computed tomography (CBCT). The differences between left- and right-side measurements and between males and females were also analyzed. Methods: The sample consisted of 20 subjects (9 males and 11 females; mean age, $21.9{\pm}3.0$) selected from the normal occlusion sample data in the Department of Orthodontics, The Catholic University of Korea. The thickness of the buccal and palatal bone walls, perpendicular to the long axis of the root were evaluated at 3 mm and 5 mm apical to cemento-enamel junction (CEJ) and at root apex. Results: At the canines and first premolars regions, mean buccal bone thickness of at 3 mm and 5 mm apical to CEJ were less than 2 mm. In contrast, at the second premolar region, mean buccal bone thickness at 3 mm and 5 mm apical from CEJ were greater than 2 mm. Frequency of thick bone wall (${\geq}2mm$) increased from the canine to the second premolar. Conclusions: This result should be considered before tooth extraction and planning of rehabilitation in the canine and premolar area of maxilla. Careful preoperative analysis with CBCT may be beneficial to assess local risk factors and to achieve high predictability of success in implant therapy.

EFFECTS OF AMYLASE ON THE DEMINERALIZATION IN HYDROXYAPATITE (Amylase가 Hydroxyapatite 탈회에 미치는 영향)

  • Lee, In-Hwan;Seo, Jeong-Taeg;Choi, Byung-Jai;Lee, Jong-Gap
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.2
    • /
    • pp.335-351
    • /
    • 1998
  • Salivary proteins which are produced in the saliary acinar cells have been known to be involved in the Calcium and phosphate metabolism. The acquired pellicle resulting from such metabolism is considered as a secondary defence membrane against tooth caries. In this respect, some proteins included in saliva probably play an important role in the prevention of demineralization in enamel. On the other hand, fluoride has long been known to prevent the demineralization of enamel by the inhibition of the growth of Streptococcus mutans(S. mutans) and by the chemical reaction with calcium and phosphate, Therefore, I have examined the roles of amylase and albumin in the demineralization of enamel and compared these preteins with fluoride in terms of anticariogenic effect. 1. The demineralization caused by S. mutans occurred slowly and progressively for the first 60 min, then the rate of demineralization was accelerated afterwards. 2. pH decreased continuously during the entire period of each experiment. 3. The demineralization was significantly inhibited by the preteatment of amylase and fluoride but albumin had little effect on it. 4. An addition of 0.1 mM lactic acid (final concentration 0.1 ${\mu}M$) caused a rapid increase in calcium concentration reaching a maximum within 10 min. 5. pH decreased rapidly by the addition of 0.1 mM lactic acid and reached a minimum within a few seconds followed by an increase in pH. pH reaced a plateu with 10 min. 6. Fluoride, amylase and albumin played little role in the 0.1 mM lactic acid-induced demineralization. 7. A slow infusion of 0.1 M lactic acid at a rate of 5 ${\mu}l/min$ caused a slower increase in calcium concentration compared with the bolus addition of lactic acid. 8. Fluoride had an inhibitory effect on the calcium release caused by slow infusion of lactic acid while amylase and albumin had no effect on it. These results suggest that fluoride inhibits demineralization by protecting the HA from the acid attack whereas amylase has a direct effect on S. mutans to prevent demineralization.

  • PDF

The Influence of Microwave Sintering Process on the Adaptation of CAD/CAM Zirconia Core (마이크로 웨이브 소결 과정이 CAD/CAM 지르코니아 코아의 적합도에 미치는 영향)

  • Kim, Keun Bae;Kim, Jee Hwan;Lee, Keun-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.95-107
    • /
    • 2009
  • The purpose of this research was to examine the fitness of zirconia cores that were made by different sintering methods; generic electricity furnace and microwave furnace. Firstly, 12 cores for each group were made by using each different sintering process and attached them to a metal die with silicon. The internal and marginal gap of sintered zirconia was measured by using Skyscan 1076 micro-CT, then it was reorganized by CT-An software. To each samples, we extracted B-L image, M-D image of cutting side, and cross-sectional side of tooth long axis and calculated the mean value of marginal, axial, and occlusal gap each side. Results: 1. The mean marginal gap of sintered zirconia was $36.20{\mu}m$ for EVE, $47.67{\mu}m$ for LAV, $52.47{\mu}m$ for DEN, and $54.63{\mu}m$ for CER. 2. For the axial wall, the research showed the largest value of $63.49{\mu}m$ for EVE, but there were no statistical significance. 3. In related to the occlusal internal measurement, DEN showed the smallest value ($77.06{\mu}m$), EVE and CER showed significantly high value. From this study, it is suggested that CAD/CAM zirconia core which was made in the process of microwave sintering has clinically acceptable values in marginal and internal gap.

A Masked Hemophilia B, Severe Bleeding after Tonsillectomy and Adenoidectomy (잠재성 혈우병 환아에서의 편도 적출후 심한출혈의 1치험례)

  • 박영서;김기헌;김선무;이종무
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1972.03a
    • /
    • pp.17.1-17
    • /
    • 1972
  • Hemophilia B is hereditary disorder of blood coagulation known as a deficiency of P.T.C. or Christmas factor. Anyway it's indistinguishable clinically with hemophia A and C. Here's one of most interesting problems gave us because we could only find it out as a hemophilia B. when we stood a situation to be met continuous bleeding from the operative wound of tonsillectomy and Adenoidectomy. Wintrobe proposed that easy bruising, difficulty in stopping the bleeding from razor cuts, and prolonged bleeding after tonsillectomy or tooth extraction usually are the major manifestations. For a long time little attention was paid to reports of a milder form of the diseases. In such cases coagulation time, and even prothrombin consumption were normal and the symptoms were correspondinly mild, small wounds as a rule giving little trouble and hemoarthrosis being uncommon. In our cases, there's no specific contributory history except nasal bleeding intermittently and also no specific contributory laboratory data before the operation. After the T. & A., there's continuous bleeding from nasopharynx and the coagulas on the both tonsilar fossas being grown day by day. Therefore we suspected some abnormality of coagulation mechanism and then we could get conclusion of hemophilia B. after various laboratory tests including T.G.T., As I know, this case, hemophilia B. is 3rd one as a report in Korea. We have no data of hemophilia family at present time, so that I propose that we have to make system of hemophilia family in Korea. In a next, we have to make routinely complete laboratory test, ego routine C.B.C., bleeding time, coagulation time, prothrombine time, partial thromboplastine time, before operation of T.& A. If we can solve these problems we can get the T. & A. without any problems of bleeding according to get the operation of T. & A.

  • PDF

The Relationship between Dental Amalgam Fillings and Urinary Mercury Concentration among Elementary School Children in a Metropolitan Area (대도시지역 일부 초등학생의 치과용 아말감 충전치아와 요중 수은농도의 관련성)

  • Jung, Yun-Sook;Sakong, Joon;An, Seo-Young;Lee, Young-Eun;Song, Keun-Bae;Choi, Youn-Hee
    • Journal of dental hygiene science
    • /
    • v.12 no.3
    • /
    • pp.253-258
    • /
    • 2012
  • Dental amalgam is an alloy composed of a mixture of approximately equal parts of elemental liquid mercury and an alloy powder. Amalgam has been the most popular and effective restorative material used in dentistry. Despite the long history and popularity of dental amalgam as a restorative material, there have been periodic concerns regarding the potential adverse health effects arising from exposure to mercury in amalgam. Since children are more at risk for mercury toxicity, we aimed to assess the association between dental amalgam filling and urinary mercury concentration in children. 581 of elementary school children in grades 1st4th were conveniently recruited from two schools located in Daegu city, Korea. To obtain dental caries experience states, oral examination were conducted using the full term for DFS index, number of amalgam filling surfaces and the type of filling materials. A questionnaire was used to collect information about general characteristics and the frequencies of tooth brushing, gum chewing and fish/seafood consumption. The statistical analysis was done using the SPSS 18.0 program. The mean urinary mercury concentration in children having more surfaces was highest. As a results Urinary mercury concentration of children who have 79 teeth of amalgam filling and more than 10 is higher than without amalgam filling. The number of amalgam filling surface is closely related with urinary mercury concentration.

MORPHOLOGICAL CHANGES OF DENTIN SURFACE TREATED WITH VARIOUS DENTIN SURFACE CONDITIONERS (수종(數種) 표면처리제(表面處理劑)에 의(依)한 상아질(象牙質) 표면(表面)의 형태(形態) 변화(變化)에 관(關)한 연구(硏究))

  • Cho, Jin-Ho;Choi, Ho-Young;Min, Byung-Soon;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.2
    • /
    • pp.323-334
    • /
    • 1988
  • The purpose of this study was to observe the effect of dentin surface conditioners on the dentin surfaces. Freshly extracted human molars were used in this study. They were stored at $4^{\circ}C$ saline solution before experiment. The crown portions of the teeth were cut in various directions by means of wet diamond point to expose dentin which include transverse, vertical oblique, horizontal and oblique cut to the long axis (Fig. 1). Each tooth was then mounted with self curing acrylic resin in brass ring to expose the flattened dentin surfaces. Final finish was accomplished by grinding the dentin specimens with wet No. 180 and No. 600 grit silicon carbide abrasive paper until a 6.0mm in diameter on a dentin surface was exposed without pulp exposure. The specimens were divided into 9 groups according to the modes of dentin treatment procedure. The following surface treatments were applied on these preparation surfaces; Group 1: unetched (control group) after finish with No. 600 silicon carbide abrasive paper. Group 2: etched with 30% phosphoric acid for 60s Group 3: etched with 10-3 solution for 60s Group 4: Cleaned with 5% NaOCl for 30s Group 5: applied Dentin Adhesit Group 6: cleaned with 5% NaOCl followed by applying the Dentin Adhesit$^{(R)}$ Group 7: applied Photo Bond on the unetched dentin followed by applying the Photo Clearfil Bright Group 8: Etched with 30% phosphoric acid followed by applying Photo Bond and Photo Clearfil Bright Group 9: etched with 10-3 solution followed by applying Photo Bond and Photo Clearfil Bright All the specimens were stored in $37^{\circ}C$ under 50% relative humidity for 24 hours before observations. The specimens in 7, 8, and 9 group, omitting the group 1 to 6, were demineralized in 10% HCl for 10s in order to observe the resin tags. All the specimens in each group were then dried at room temperature. The dried specimens were ion coated with Eiko ion coater (Eiko-engineering Co.), and observed in Hitachi S-430 Scanning electron microscope (Hitachi, Co. Tokyo) at 15KV. The following results were obtained as follows; 1. The smear layers were still remained in group 1,2,4,5, and 6. 2. There is no effect of 5% NaOCl and 30% phosphoric acid on the changes of dentin morphology 3. The dentin treated with 10-3 solution, indicating the tubules opened when the smear layer and the dental plug dissolved. 4. In case of applying the bonding agents the resin tag was not formed at the deep area of dentinal tubules, but in case of applying the Dentin Adhesit$^{(R)}$ that was not.

  • PDF

AN ELECTRON MICROSCOPIC STUDY OF THE PERIAPICAL GRANULOMA AND THE PERIAPICAL CYST (치근단육아종(齒根端肉芽腫)과 치근단양종(齒根端襄腫)의 전자현미경적(電子顯微鏡的) 연구(硏究))

  • Yo, In-Ho;Lim, Sung-Sam
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.2
    • /
    • pp.283-294
    • /
    • 1988
  • The purpose of this study was to investigate the characteristic features of the cells and tissues of the chronic periapical lesions using light microscope and electron microscope. Fifteen dental periapical lesions were obtained from the patients undergoing periapical surgery. Each specimen was divided into two parts along the tooth axis. One part was routinely processed for histopathologic examinations. 12 periapical lesions were diagnosed as granuloma and 3 periapical specimens as periapical cyst. The other part was fixed in 2.5% glutaraldehyde in 0.1M sodium cacodylate buffer at pH 7.4 and 1% osmic acid in same buffer. They were embedded in Epon 812. The semithin sections were used for the orientation of the lesions and the ultrathin sections were stained conventionally and examined with AEI Corynth 500 electron microscope. The results were as follows. 1. PMN and macrophages, which were dominant cell type, were scattered in small or large numbers throughout the central destructive area of granuloma. In the granulomatous area, plasma cells and lymphoytes were found in significant number and a lot of new capillary formation were revealed. Clefts caused by cholesterol were often seen in the connective tissue. Occasionally foam cells became collected in groups and epithelial proliferation were present. 2. In both granuloma and cyst, some plasma cells contained narrow cisternae of granular endoplasmic reticulum of which was tightly packed with electron dense materials, and other cells exhibited dilated profiles of granular endoplasmic reticulum. 3. In the area where plasma cells and lymphocytes were collected in groups, lymphocytes with well developed nucleolus and profuse cytoplasm were found and differentiating plasma cells were also present. 4. In the epithelial strands of the granulomatous area, epithelial cells contained enlarged endoplasmic reticulum, tonofilaments and ribosoms. Toward the intercellular space epithelial cells protruded a few microvilli. In the intercellular space, exudate-like electron dense materials, most of which was attached to the plasma membrane, appeared. 5. Some foam cells filled with numerous lipid droplets and others had lipid droplets and crystal-like structures. 6. Cyst epithelium consisted of bright cells and dark cells. The former had bright cytoplasm and small amounts of ribosoms, and the latter dark cytoplasm, many ribosoms, mitochondria and elongated microvilli. 7. Epithelial cells near the cyst lumen protruded a lot of long microvilli toward intercellular space and cyst lumen.

  • PDF

MARGINAL FIDELITY AND FRACTURE STRENGTH OF IPS EMPRESS $2^{(R)}$ CERAMIC CROWNS ACCORDING TO DIFFERENT CEMENT TYPES

  • Cho Hyun-Ok;Kang Dong-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.6
    • /
    • pp.545-559
    • /
    • 2002
  • There has been increasing use of IPS Empress $2^{(R)}$ owing to easy fabrication method, high esthetics similar to natural teeth, good marginal accuracy, and sufficient fracture strength. However, in clinical application, although a luting agent and the tooth cementation bonding procedure influence the marginal accuracy and fracture strength restoration, there has been a controversy in the selection of proper luting agent. This study was to measure the marginal fidelites and fracture strength of IPS Empress crowns according to three cement types, Protec $cem^{(R)}$, Variolink $II^{(R)}$ and Panavia $21^{(R)}$. After construction of 12 experimental dies for each group, IPS Empress $2^{(R)}$ crowns were fabricated and luted the metal master die prepartion of the maxillary right premolar. Marginal gaps before cementation and after cementation were measured. Buccal incline on the functional cusp of specimens were loaded until the catastrophic failure and fracture strength was measured. The results of this study were as follows: 1. The range of gap was $34.04{\pm}4.84{\mu}m$ before cementation and $37.88{\pm}5.00{\mu}m$ after cementation, which showed significant difference by paired t-test (p<0.05). The difference in the results from marginal accuracy according to measuring point proved to be not statistically significant by two-way ANOVA test (p>0.05). 2. The difference in the results from marginal accuracy according to three cement types Proved that The Variolink $II^{(R)}$ cement group had the least gap, $35.43{\pm}5.03{\mu}m$, and showed superior marginal accuracy while there existed statistic significance in Protec $cem^{(R)}$ cement group, $39.06{\pm}4.41{\mu}m$ or Panavia $21^{(R)}$ cement group, $39.16{\pm}4.39{\mu}m$ by two-way ANOVA test & multiple range test (p<0.05). 3. The difference in the results from fractures strength testing according to three cement type groups proved to be statistically significant (p<0.05). The Variolink $II^{(R)}$ cement group shows highest fracture strength of $1257.33{\pm}226.77N$, Panavia $21^{(R)}$ cement group has $1098.08{\pm}138.45N$, and Protec $cem^{(R)}$ cement group represents the lowest fracture strength of $926.75{\pm}115.75N$. 4. Three different cement groups of different components showed acceptable marginal fidelity and fracture strength. It is concluded that IPS Empress $2^{(R)}$ crowns luted using Variolink $II^{(R)}$ cement group had stronger fracture strength and smaller marginal gap than the other cement groups. Although Variolink $II^{(R)}$ resin cement seemed acceptable to clinical applications in IPS Empress $2^{(R)}$ system, the IPS Empress $2^{(R)}$ system still requires long-term research due to the lack of data in clinical applications.

Effect of embossed new dental pick on periodontitis (Embossed new dental pick이 치주염에 미치는 영향)

  • Suk, Hun-Joo;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.3
    • /
    • pp.563-572
    • /
    • 2004
  • Since bacterial plaque is known as the major cause of every oral disease, it is necessary to control plaque to maintain periodontal health. Although tooth brushing has been the typical method of plaque control, additional use of plaque control devices are necessary for cleansing interdental areas. Dental floss has been used for a long time as the additional plaque control device and proved to be effective. The newly developed embossed new dental pick is composed of elastic plastic material in form with its tip longer than other toothpick. In addition, as thickness of the tip gradually increases, it can be adapted easily with minimal trauma to interdental gingiva. The embossed tip can remove dental plaque easily, and the opposite end can approach lingual and palatal areas through triple angulation. Therefore, the authors studied the effect of embossed new dental pick and dental floss on periodontally involved 15 patient. The following results were obtained. 1. For embossed new dental pick, probing depth at baseline, 1 week, 4 weeks were $3.6{\pm}0.6mm$, $3.4{\pm}0.5mm$, $3.2{\pm}0.5mm$, respectively, and $4.2{\pm}0.9mm$, $4.1{\pm}0.9mm$, $4.0{\pm}0.9mm$, respectivly for clinical attachment level. 2. In case of embossed new dental pick, bleeding on probing at baseline, 1 week, 4 weeks were $43.0{\pm}4.4%$, $28.5{\pm}5.1%$, $22.2{\pm}5.6%$, respectively, and, at 1 week and 4 weeks, they were significantly different from that of dental floss. 3. Gingival index of toαhpick at baseline, 1 week, 4 weeks were $1.7{\pm}0.5$, $1.0{\pm}0.3$, $0.9{\pm}0.2$, respectively, and, $1.7{\pm}0.5$, $1.1{\pm}0.4$, $1.0{\pm}0.4$, respectively for plaque index, and $3.0{\pm}0.5$, $1.7{\pm}0.5$, $1.4{\pm}0.4$, respectively for proximal plaque index. proximal plaque index at 4 weeks was significantly different from that of dental floss. 4. The result of questionnaire showed that the two types of device were both satisfactory, however, embossed new dental pick had higher preference as well as satisfaction. As a result, embossed new dental pick is thought to be clinically effective for its simplicity and good accessibility.