• Title/Summary/Keyword: long term stability

Search Result 1,162, Processing Time 0.027 seconds

Amperometric Glucose Biosensor Based on Sol-Gel-Derived Zirconia/Nafion Composite Film as Encapsulation Matrix

  • Kim, Hyun-Jung;Yoon, Sook-Hyun;Choi, Han-Nim;Lyu, Young-Ku;Lee, Won-Yong
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.1
    • /
    • pp.65-70
    • /
    • 2006
  • An amperometric glucose biosensor has been developed based on the use of the nanoporous composite film of sol-gel-derived zirconia and perfluorosulfonated ionomer, Nafion, for the encapsulation of glucose oxidase (GOx) on a platinized glassy carbon electrode. Zirconium isopropoxide (ZrOPr) was used as a sol-gel precursor for the preparation of zirconia/Nafion composite film and the performance of the resulting glucose biosensor was tuned by controlling the water content in the acid-catalyzed hydrolysis of sol-gel stock solution. The presence of Nafion polymer in the sol-gel-derived zirconia in the biosensor resulted in faster response time and higher sensitivity compared to those obtained at the pure zirconia- and pure Nafion-based biosensors. Because of the nanoporous nature of the composite film, the glucose biosensor based on the zirconia/Nafion composite film can reach 95% of steady-state current less than 5 s. In addition, the biosensor responds to glucose linearly in the range of 0.03-15.08 mM with a sensitivity of 3.40 $\mu$A/mM and the detection limit of 0.037 mM (S/N = 3). Moreover, the biosensor exhibited good sensor-to-sensor reproducibility (~5%) and long-term stability (90% of its original activity retained after 4 weeks) when stored in 50 mM phosphate buffer at pH 7 at 4 ${^{\circ}C}$.

Electrochemical performance of double perovskite structured cathodes for intermediate temperature SOFCs

  • Jo, Seung-Hwan;Muralidharan, P.;Kim, Do-Kyung
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.56.1-56.1
    • /
    • 2009
  • The intermediate operating temperature of solid oxide fuel cells (IT-SOFCs) have achieved considerable importance in the area of power fabrication. This is because to improve materials compatibility, their long-term stability and cost saving potential. However, to conserve rational cell performance at reduced-temperature regime, cathode performance should be obtained without negotiating the internal resistance and the electrode kinetics of the cell. Recently, double perovskite structure cathodes have been studied with great attention as a potential material for IT-SOFCs. In this study, double-perovskite structured cathodes of $GdBaCoCuO_{5+\delta}$, $GdBaCo_{2/3}Cu_{2/3}Fe_{2/3}O_{5+\delta}$ compositions and $(1-x)GdBaCo_2O_{5+\delta}+xCe_{0.9}Gd_{0.1}O_{1.95}$ (x = 10, 20, 30 and 40 wt.%) composites were evaluated as the cathode for intermediate temperature solid oxide fuel cells(IT-SOFCs). Electrical conductivity of the cathodes were measured by DC 4-probe method, and the thermal expansion coefficient of each sample was measured up to $900^{\circ}C$ by a dilatometer study. Area specific resistances(ASR) of the $GdBaCo_{2/3}Cu_{2/3}Fe_{2/3}O_{5+\delta}$ cathode and 70 wt.% $GdBaCo_2O5+\delta$ + 30wt.% Ce0.9Gd0.1O1.95 composite cathode on CGO electrolyte substrate were analyzed using AC 3-probe impedance study. The obtained results demonstrate that double perovskite-based compositions are promising cathode materials for IT-SOFCs.

  • PDF

LEAK-BEFORE-BREAK ANALYSIS OF THERMALLY AGED NUCLEAR PIPE UNDER DIFFERENT BENDING MOMENTS

  • LV, XUMING;LI, SHILEI;ZHANG, HAILONG;WANG, YANLI;WANG, ZHAOXI;XUE, FEI;WANG, XITAO
    • Nuclear Engineering and Technology
    • /
    • v.47 no.6
    • /
    • pp.712-718
    • /
    • 2015
  • Cast duplex stainless steels are susceptible to thermal aging during long-term service at temperatures ranging from $280^{\circ}C$ to $450^{\circ}C$. To analyze the effect of thermal aging on leak-before-break (LBB) behavior, three-dimensional finite element analysis models were built for circumferentially cracked pipes. Based on the elasticeplastic fracture mechanics theory, the detectable leakage crack length calculation and J-integral stability assessment diagram approach were carried out under different bending moments. The LBB curves and LBB assessment diagrams for unaged and thermally aged pipes were constructed. The results show that the detectable leakage crack length for thermally aged pipes increases with increasing bending moments, whereas the critical crack length decreases. The ligament instability line and critical crack length line for thermally aged pipes move downward and to the left, respectively, and unsafe LBB assessment results will be produced if thermal aging is not considered. If the applied bending moment is increased, the degree of safety decreases in the LBB assessment.

Investigation on Watertight Properties of the Latex Concrete for Protection Layers of the Slab on Vibrating Strucutres (진동구조물 슬래브 보호층으로서 라텍스 콘크리트의 수밀특성 분석)

  • Lee, Sun-Gyu;Lee, Jung-Hoon;Choi, Sung-Min;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.247-252
    • /
    • 2009
  • The LMC method of construction which have application to the road bridge is being considered the least relative importance about the watertight performance, because it focused on the durability of concrete. However, The LMC which is being expanded scope of application to the method of construction has grown importance about the watertight performance on the usability and maintenance side as well as durability. In this study, The latex concrete of two types which are different from mingled-ratio of the latex made a comparison to the compressive strength, watertight performance, dynamic wheel load resistance performance and confirmed what it has resistibility about chemical action through the chemical resistance test. The initial strength and watertight performance showed that were tendency the downward at 14 days. However, The long-term strength after 28 days showed that it has firm performance. In consequence, The initial curing of latex concrete is required to scrupulous care and attention at the site application. As a chemical resistance test result, The specimen that is steeped in sulphuric acid solution of 2% discovered the delamination phenomenon. However, it was confirmed that delamination phenomenon don't have an effect on the compressive strength. Moreover, As a dynamic wheel load resistance test result, The latex concrete was concluded to confirming the durability and running stability, because it had hardly any thickness reduction of latex concrete surface about dynamic wheel load and rarely found crack and delamination.

  • PDF

Effects of the contingent liabilities caused by project financing on financial status of the Korean construction firms (프로젝트금융으로 인한 우발채무가 건설기업의 재무상태에 미치는 영향)

  • Kang, Namhui;Kim, Hyunjoong;Choi, Jaehyun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.6
    • /
    • pp.84-91
    • /
    • 2015
  • Project Financing (PF) is a financing method, executed based upon the projected profitability from a project itself instead of relying on the credit rating of project sponsors or any type of collateral. However, most financial institutions of Korea lacks the long term profitability assessment capability, and they prefer to acquire credit reinforcement from the construction companies in the form of the guarantor or debt argument commitments. As a result, PF contingent liabilities as an indirect debt, are burdened to the construction companies. Even though the PF contingent liabilities are not supposed to be part of the financial statements, they became a mandatory disclosure items since 2009. In this study, PF contingent liabilities were studied to indicate how they were correlated with construction firms' financial ratios. Construction firms were grouped by their credit rating and each group was compared in order to analyze PF contingent liabilities' impact on the financial condition of the company in terms of liquidity, liability, and stability.

Study on Combination of External Gosamgamibang and Internal Chenggihaedok-san for the Treatment of Atopic Dermatitis (아토피피부염에 대한 고삼가미방(苦參加味方)과 청기해독산(淸肌解毒散)의 겸용 투여 효과)

  • Ko, Hong-Yun;Kim, Dong-Hee
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.6
    • /
    • pp.1282-1291
    • /
    • 2009
  • A combined prescription of GGB and CHS (G&C prescription group) was used to investigate its effects on immune related factors and histological changes in atopic dermatitis(AD) induced mice. Significant decrease of atopic dermatitis clinical index in G&C prescription group. In DLN, G&C prescription group significantly modulated the immune cells. G&C prescription group also showed significant effect on the immune cells of the dorsal skin as well as DLN. The group indicated significant decrease of the biosynthesis of IL-4, IL-5, IL-13, GM-CSF, cytokines in serum. On the other hand, the biosynthesis of TNF-$\alpha$ was decreased. G&C prescription group significantly decreased the immunoglobulin IgE levels in serum. The results suggest that G&C prescription significantly improves atopic dermatitis through regulation of immune cells and cytokines. Comparative studies with Protopic ointment also showed that G&C prescription showed significant effect in AD patients, and active application of the prescription in clinicals is anticipated. However, the reason for the results that oppose to those of previous studies should be investigated. Also, therapeutic effects of both internal and external applications should be studied individually as well as for any synergistic effects. Safety, toxicity, as well as stability studies should follow to develop G&C prescription into long-term external clinical product.

Simulation of tissue differentiation around acetabular cups: the effects of implant-bone relative displacement and polar gap

  • Mukherjee, Kaushik;Gupta, Sanjay
    • Advances in biomechanics and applications
    • /
    • v.1 no.2
    • /
    • pp.95-109
    • /
    • 2014
  • Peri-acetabular bone ingrowth plays a crucial role in long-term stability of press-fit acetabular cups. A poor bone ingrowth often results in increased cup migration, leading to aseptic loosening of the implant. The rate of peri-prosthetic bone formation is also affected by the polar gap that may be introduced during implantation. Applying a mechano-regulatory tissue differentiation algorithm on a two-dimensional plane strain microscale model, representing implant-bone interface, the objectives of the study are to gain an insight into the process of peri-prosthetic tissue differentiation and to investigate its relationship with implant-bone relative displacement and size of the polar gap. Implant-bone relative displacement was found to have a considerable influence on bone healing and peri-acetabular bone ingrowth. An increase in implant-bone relative displacement from $20{\mu}m$ to $100{\mu}m$ resulted in an increase in fibrous tissue formation from 22% to 60% and reduction in bone formation from 70% to 38% within the polar gap. The increase in fibrous tissue formation and subsequent decrease in bone formation leads to weakening of the implant-bone interface strength. In comparison, the effect of polar gap on bone healing and peri-acetabular bone ingrowth was less pronounced. Polar gap up to 5 mm was found to be progressively filled with bone under favourable implant-bone relative displacements of $20{\mu}m$ along tangential and $20{\mu}m$ along normal directions. However, the average Young's modulus of the newly formed tissue layer reduced from 2200 MPa to 1200 MPa with an increase in polar gap from 0.5 mm to 5 mm, suggesting the formation of a low strength tissue for increased polar gap. Based on this study, it may be concluded that a polar gap less than 0.5 mm seems favourable for an increase in strength of the implant-bone interface.

Effect of Initial Volume of Hard Water and Contact Time on the Reduction of Calcium Ion Concentration using High Voltage Impulse Technique (고전압 임펄스 기술을 활용한 경도 제거에서 경수의 초기부피와 인가시간이 칼슘이온 농도에 미치는 영향)

  • Cho, Seung-Yeon;Kim, Tae-Hui;Chang, In-Soung;Hong, Woong-ki;Lee, June-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.7
    • /
    • pp.1066-1071
    • /
    • 2017
  • Recently high voltage impulse (HVI) technique has been extensively studied for desalting processes to control the $CaCO_3$ scale formation in industrial water practices such as power plant, boiler, and heat exchange operations. Investigation of the operational parameters for the HVI is important, however, those had not been reported yet. In this study, the effect of initial feed volume and contact time on reduction of calcium ion concentration by the HVI technique was investigated. Initial feed volumes of artificial hard water which contained 100 mg/L of $Ca^{2+}$, were set to 1, 2, and 3 L respectively. After 24hr of HVI contact with 12kV, $Ca^{2+}$ ion was reduced to 50, 29 and 19 % of their initial concentration, indicating that calcium removal increased as initial feed volume decreased. This implies the applied HVI pulse energy per unit mass of calcium is important parameter determining overall desalting efficiency. A series of extended operations of HVI up to 30 days verified the long term stability of the HVI system. The calcium ion declined to 40 mg/L after 2~3 days, and further reduction of calcium was not achieved, indicating that optimum operation time could be 2~3 days under these experimental conditions. Consequently, it was confirmed that the important operational parameter of HVI technique is initial feed volume and contact time as well as the applied voltage that was already proven in the previous study.

T-RFLP Analysis of Microbial Community Structure in Leachate from Landfill Sites (폐기물매립장 침출수내 미생물군집 구조 해석을 위한 T-RFLP의 활용)

  • Yu, Jae-Cheul;Ishigaki, Tomonori;Kamagata, Yoichi;Lee, Tae-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.4
    • /
    • pp.369-378
    • /
    • 2010
  • Microorganisms are key-role player for stabilization of landfill sites. In order to evaluate the availability of T-RFLP(Terminal Restriction Fragment Length Polymorphism) for monitoring microbial community variations during stabilization of landfill sites, the phylogenic diversity of microbial community in the leachate from 4 different full-scale landfills was characterized by T-RFLP based on bacterial 16S rDNA. Main population of microbial community analyzed by T-RFLP was significantly similar with that of microbial community analyzed by clone library analysis. The results of T-RFLP analysis for main population of microbial community in the leachate from landfills with different landfill structures, waste types and landfill ages showed apparently different microbial diversity and structures. Therefore, long-term monitoring of microbial community in leachate from landfill sites by using T-RFLP is expected to be available for evaluation of landfill stability.

Weather Characteristics of Oenarodo Space Center (외나로도 우주센터의 기상특성)

  • Kim, Jhoon;Kook, B.J.;Moon, K.J.;Lee, J.H.;Koo, J.H.;Park, S.S.;Lee, H.K.
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.3
    • /
    • pp.314-327
    • /
    • 2009
  • Weather launch criteria of launch at Oenarodo Space Center is important for the successful launch operation. In particular, most of the launch failure occurs during the period of separation from the launch pad, thus meteorological condition is critical at this phase. In earlier days, the weather launch criteria adopted wind and forecast data for the launch operation. Nevertheless, the control of position and stability require other meteorological components such as vertical wind shear, lightning, temperature and visibility, because the launch vehicle is moving mostly vertically. We analyze these meteorological components by using the observed data at KMA at neighboring Oenarodo to determine the weather launch criteria. These criteria need further refinements through long-term observation.