• Title/Summary/Keyword: long slit

Search Result 77, Processing Time 0.036 seconds

A Study on the Size of the Back Slit for Tight Skirts - In the Case of Walking on the Floor or Stairways - (동작에 따른 타이트스커트의 뒤트임 분량에 대한 연구 -보행시와 계단 승강시 -)

  • Kim Chung Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.16 no.4 s.44
    • /
    • pp.485-493
    • /
    • 1992
  • Three kinds of tight skirts, slim type, straight type, and semi-tight type were investigated to obtain necessary information about the size of the back slit. Fourteen college students put on these experimental clothes and walked on the flat floor, going up and down the stairs. The dimensions of the back slit were measured by width and length. The stride length was taken from the record of footprints of walking. The correlation between the body measurement, stride length and the size of the back slit was studied. As a result of this experiment, the findings are as follows: 1. The size of the back slits differed from each skirt type at the level of p<0.001. In the case of walking on the floor, the average dimension of the back slit was 14.0 cm long 5.0 cm wide for the slim type,9.5 cm long 2.8 cm wide for the straight type and 2.1 cm long 0.5 cm wide for the semi-tight type. 2. In the case of walking on the stairways, the average dimension of the back slit was 16.0 cm long 5.8 cm wide for the slim type, 12.4 cm long 3.9 cm wide for the straight type and 3.1 cm long 1.1 cm wide for the semi-tight type. 3. The correlation between the height (stature, waist height, knee height) and the size of back slit was 0.3 to 0.6. The correlation between the girth (waist, hip) and the size of back slit was 0.3 to -0.5. 4. The correlation between the stride length and the size of back slit was 0.76 for the slim skirt, 0.56 for the straight skirt, 0.28 for the semitight skirt.

  • PDF

LONG-SLIT SPECTROSCOPY FOR EXTENDED OBJECTS (면천체(EXTENDED OBJECTS)에 대한 긴 슬릿 분광관측 연구)

  • SUNG EON-CHANG
    • Publications of The Korean Astronomical Society
    • /
    • v.15 no.spc1
    • /
    • pp.39-60
    • /
    • 2000
  • We will discuss two-dimmensional spectrophotometry including long-slit spectroscopy and narrow-band imaging. The basic principles, applications, and techniques of observations and data reduction of spectroscopy and spectrophotometry for extended objects are described. This discussion will focus on practical long-slit spectroscopy using a Cassegrain spectrograph attached with 2 or 4m class telescopes and on imaging spectrophotometry using narrow-band interference filter sets. We will discuss scientific applications.

  • PDF

PERFORMANCE TEST OF THE BOAO LONG SLIT SPECTROGRAPH (LSS) (보현산천문대 긴슬릿 분광기의 성능 분석)

  • Kim, Kang-Min;Lee, Byeong-Chul;Han, In-Woo;Yoon, Tae-Seog
    • Publications of The Korean Astronomical Society
    • /
    • v.18 no.1
    • /
    • pp.81-86
    • /
    • 2003
  • We tested the characteristics of the newly made Long Slit Spectrograph (LSS) of the BOAO which replaced the Medium Dispersion Spectrograph (MDS) in the year of 2003. Performance test results on the spectrogram shift by gravity direction variation, slit illumination function, efficiency and the precision of the radial velocity measurements show the capabilities of the LSS are much improved in every respect comparing with those of the MDS.

FLUX CALIBRATION METHOD OF SLIT SPECTROMETER FOR EXTENDED SOURCES

  • Lee, Sung-Ho;Park, Soo-Jong
    • Journal of The Korean Astronomical Society
    • /
    • v.39 no.4
    • /
    • pp.151-155
    • /
    • 2006
  • Long slit spectrometers are widely used in optical and infrared bands in astronomy. Absolute flux calibration for extended sources, however, is not straightforward, because a portion of the radiation energy from a flux calibration star is blocked by the narrow slit width. Assuming that the point spread function(PSF) of the star is circularly symmetric, we develop a robust method to extrapolate the detected stellar flux to the unobscured flux using the measured PSF along the slit-length direction. We apply this method to our long slit data and prove that the uncertainty of the absolute flux calibration is less than a few percents.

DESIGN AND MANUFACTURING OF THE CASSEGRAIN INTERFACE MODULE OF THE BOAO ECHELLE SPECTROGRAPH

  • KIM KANG-MIN;JANG BE-HO;HAN INWOO;JANG JEONG GYUN;SUNG HYUN CHUL;CHUN MOO-YOUNG;HYUNG SIEK;YOON TAE-SEOG;VOGT STEVEN S.
    • Journal of The Korean Astronomical Society
    • /
    • v.35 no.4
    • /
    • pp.221-227
    • /
    • 2002
  • Cassegrain interface module (CIM) of the fiber-fed high resolution echelle spectrograph has been designed and manufactured for the 1.8 m reflector at the Bohynsan Optical Astronomy Observatory. We also constructed a long slit spectrograph attached to this CIM, which would replace the earlier rather inefficient medium dispersion spectrometer. We present detailed description for design and manufacturing concepts of the CIM which consists of a slit assembly, slit monitoring system, calibration lamp system and a long slit spectrograph, in order to provide how the overall system and each part. are constructed. The preliminary performance test carried out so far seems to indicate a successful result.

Optical Long-slit Spectroscopy of Parsec-scale Jets from DG Tau

  • Oh, Heeyoung;Pyo, Tae-Soo;Yuk, In-Soo;Park, Byeong-Gon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.75.1-75.1
    • /
    • 2014
  • We present the result of a long-slit spectroscopic study of DG Tau, which is known to emanate parsec-scale outflows. To study the kinematics and physical properties of the jet, we obtained the optical emission lines of $H{\alpha}$, [OI], [NII], and [SII] from HH 158 and HH 702 using the long-slit spectrograph at Bohyunsan Optical Astronomical Observatory. HH 158 shows the peak radial velocity in a range of ~ - 270 to - 30 km s-1. HH 702, located at 11' away from DG Tau shows the velocity of ~ - 80 km s-1. The proper motion velocities of detected knots are estimated through the comparisons with the locations of those knots in the previous studies. We also examine the variations of physical parameters depending on the velocity distribution and the distance from the source using line ratio maps derived from obtained forbidden emission lines.

  • PDF

Wall charge effects on structural properties of a coarse-grained FENE polyelectrolyte confined in slit nanochannels by Brownian dynamics simulation

  • Jeon, Jong-Gu;Chun, Myung-Suk
    • Korea-Australia Rheology Journal
    • /
    • v.19 no.2
    • /
    • pp.51-59
    • /
    • 2007
  • A polyelectrolyte chain confined in a slit nanochannel exhibits a structural transition from the one in free space. In this paper, the effect of the long-range electrostatic interactions between the xanthan polyelectrolyte and the slit wall on the confined xanthan conformation is investigated via the Brownian dynamics simulation. A neutral and two negatively charged surfaces of polydimethylsiloxane (PDMS) and glass are combined to make four kinds of slit channels with different charge characteristics: i) neutral-neutral, ii) glass-glass, iii) neutral-PDMS and iv) neutral-glass walls. Their walls are characterized by uniform surface charge densities determined from experimental data of zeta potential. Both the nonmonotonic chain size variation and the loss of long-range bond vector correlation, previously observed under confinement in the PDMS-PDMS slit, are also found in the neutral slit, demonstrating the nonelectrostatic origin of such crossover behaviors. As expected, the effect of wall charges is negligible at sufficiently high medium ionic strength of 100mM but it becomes significant in the opposite limit of 0.01mM. In the latter case, the high charge density of glass walls strengthens the effective confinement of a negatively charged polyelectrolyte and produces a xanthan structure comparable to that confined in a much narrower neutral slit. The obtained structural data suggest the possibility of controlling the structure of confined polyelectrolytes by the modification of surface charge characteristics of micro/nanofluidic devices in combination with the adjustment of the medium ionic strength.

3-D Profile Measurement System of Live Human Faces for the '93 Taejon Expo Kumdori Robot Scupltor (93 대전엑스포 꿈돌이 조각가로보트의 인물형상 측정시스템)

  • 김승우;박현구;김문상
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.3
    • /
    • pp.670-679
    • /
    • 1995
  • This paper presents the 3-D profile measurement system of live human faces, which was developed specially for 'KUMDORI sculptor robot' of the '93 Taejon Exposition. '93 Taejon EXPO. The basic principle for measurement adopts the slit beam projection which is a method of measuring 3-D surface profiles using geometric optics between the slit beam and the CCD camera. Since the slit beam projection consumes long measuring time, it is unfit to measure the 3-D profiles of living objects as human. Therefore, the projection type slit beam method which consumes short measuring time is newly suggested. And an algorithm to reconstruct the 3-D profile from the deformed images using finite approximated calibration is suggested and practically implemented. The projection type slit beam method was applied to spectators in a period of '93 Taejon EXPO. The measurement results show that the technique is suitable for 3-D face profile measurement on a living body.

Integral Field Spectroscopic Data Reduction Method for High Resolution Infrared Observation

  • Lee, Sung-Ho;Pak, Soo-Jong;Choi, Min-Ho
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.4
    • /
    • pp.309-318
    • /
    • 2010
  • We introduce a technical approach for reducing three-dimensional infrared (IR) spectroscopic data generated by integral field spectroscopy or slit-scanning observations. The first part of data reduction using IRAF presents a guideline for processing spectral images from long-slit IR spectroscopy. Multichannel image reconstruction, Image Analysis and Display (MIRIAD) is used in the later part to construct and analyze the data cubes which contain spatial and kinematic information of the objects. This technic has been applied to a sample data set of diffuse 2.1218 ${\mu}m$ $H_2$ 1-0 S(1) emission features observed by slit-scanning around Sgr A East in the Galactic center. Details of image processing for the high-dispersion infrared data are described to suggest a sequence of contamination cleaning and distortion correction. Practical solutions for handling data cubes are presented for survey observations with various configurations of slit positioning.

An Experimental Study of the Airside Performance of Slit Fin-and-Tube Heat Exchangers under Dry and Wet Conditions

  • Chang, Keun-Sun;Long, Phan-Than
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.17 no.1
    • /
    • pp.7-14
    • /
    • 2009
  • Water condensate accumulated on the surface of a fin-and-tube heat exchanger significantly affects its thermal and hydraulic performances. The purpose of this study is to investigate the effects of condensate retention on the air-side heat transfer performance and flow friction for various flow and geometric conditions. Total of twelve samples of slit and plate fin-and-tube heat exchangers are tested under dry and wet conditions. The thermal fluid measurements are made using a psychrometric calorimeter. Frontal air velocity varies in the range from 0.7 m/s to 1.5 m/s. Using the experimental data, presented are heat transfer coefficients in terms of Colburn j-factors and friction factors, and these data are compared with the existing correlations.