• Title/Summary/Keyword: long implant

Search Result 514, Processing Time 0.032 seconds

Full mouth rehabilitation of patient with severe dental caries with implant fixed prosthesis fabricated with milling and 3D printing method: A case report (밀링 및 3D 프린팅 방법으로 제작된 임플란트 보철물을 이용한 심한 우식 환자의 완전 구강 회복 증례)

  • Kim, Taeyoon;Lee, Jun-Suk;Hong, Seoung-Jin;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.288-295
    • /
    • 2019
  • Passive fit of prosthesis is an essential property of implant supported prosthesis for long term success and minimization of complications. And the property is determined mostly by fabrication procedure. There were limitations of extensive implant prosthesis because conventional casting method generate contraction error of long span prosthesis. However, Computer-aided design/Computer-aided manufacturing (CAD/CAM) technology of 3D printing and milling metal framework can overcome those limitations. This case is a full mouth rehabilitation using extensive implant fixed prosthesis. Removable interim prosthesis was made for esthetic, functional evaluation and a guide for implant insertion. After the insertion, implant fixed interim prosthesis was delivered. After additional evaluation and adjustment, final prosthesis was designed with CAD, the fabricated with CAM. Milling technique was used for anterior screw type implant superstructure and 3D printing technique was used for the anterior and posterior implant copings. Fit of the final restoration was favorable. The practitioner and patient were both esthetically and functionally satisfied with the final result.

Reinforcing the retention of provisional restoration using provisional implant on maxillary anterior region: clinical case report (상악 전치부 고정성 보철물 수복 시 임시 임플란트를 이용한 임시보철물의 유지력 증가 증례보고)

  • Kim, Chang-Dae;Moon, Hong-Seok;Chung, Moon-Kyu;Lee, Jae-Hoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.221-225
    • /
    • 2013
  • Proper management of provisional prosthesis is key to success in prosthodontics. Provisional restoration on maxillary anterior missing area frequently come across a incident of falling off especially in patients with long span pontics and oval arch shape. This is because maxillary anterior teeth are more exposed to horizontal force than the posterior teeth and additional anterior cantilever effect will negatively affect to the retention of provisional prosthesis. Beside that maxillary anterior provisional prosthesis should provide proper incisal guidance during the mandibular functional movements. However occlusal contacts on the prosthesis in maximum intercuspal position are located on opposite side of fulcrum line of prosthesis which will cause removing force against the provisional prosthesis. This case report present that provisional implant prevent pre-described harmful effect on maxillary anterior fixed provisional prosthesis and provide comfort and satisfactory result during post-extraction healing period.

Wear, microleakage and plastic deformation of an implant-supported chair-side bar system

  • Mehl, Christian Johannes;Steiner, Martin;Ludwig, Klaus;Kern, Matthias
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.4
    • /
    • pp.323-328
    • /
    • 2015
  • PURPOSE. This in-vitro study was designed to evaluate retention forces, microleakage and plastic deformation of a prefabricated 2-implant bar attachment system (SFI-Bar, Cendres+$M{\acute{e}}taux$, Switzerland). MATERIALS AND METHODS. Two SFI implant-adapters were torqued with 35 Ncm into two implant analogues. Before the tube bars were finally sealed, the inner cavity of the tube bar was filled with liquid red dye to evaluate microleakage. As tube bar sealing agents three different materials were used (AGC Cem (AGC, resin based), Cervitec Plus (CP; varnish) and Gapseal (GS; silicone based). Four groups with eight specimens each were tested (GS, GS+AGC, AGC, CP). For cyclic loading, the attachment system was assembled parallel to the female counterparts in a chewing simulator. The mean retention forces of the initial and final ten cycles were statistically evaluated (ANOVA, ${\alpha}{\leq}.05$). RESULTS. All groups showed a significant loss of retention forces. Their means differed between 30-39 N initially and 22-28 N after 50,000 loading cycles. No significant statistical differences could be found between the groups at the beginning (P=.224), at the end (P=.257) or between the loss of retention forces (P=.288). Microleakage occurred initially only in some groups but after 10,000 loading cycles all groups exhibited microleakage. CONCLUSION. Long-term retention forces of the SFI-Bar remained above 20 N which can be considered clinically sufficient. The sealing agents in this study are not suitable to prevent microleakage.

Effect of supportive periodontal therapy on long-term implant survival rate

  • Choi, So-Jeong;Kim, Ok-Su
    • Oral Biology Research
    • /
    • v.42 no.4
    • /
    • pp.228-234
    • /
    • 2018
  • The aim of this study was to determine the condition of supportive periodontal therapy (SPT) in implant patients and the effect of SPT on implant long-term survival. Implants placed at the Dept. of Periodontology, Chonnam National University Dental Hospital over a 5-year period, were traced for up to 8 years. Patients who had visited the hospital at least once a year were defined as regular SPT, and patients who were treated by active periodontal therapy were defined as patients with periodontitis. Kaplan-Meier survival analysis was performed based on the observation periods, and the effect of SPT and history of periodontitis on implant survival assessed by chisquare test. A total of 183 patients (age: 21-91, 98 males and 85 females), and 508 implants were used for this study. Three hundred eight implants were under SPT and 87 implants was under regular SPT. For the patients with periodontitis 136 implants were placed. The 5-year survival rate was 94.8%. The overall survival rate in patients who received SPT was 97.1% and 91.0% for those who did not (p=0.004). The survival rate in patients who received regular SPT was 97.7%, and 96.8% for patients received irregular SPT. The survival rate was 93.4% in patients with periodontitis and 95.2% in patients without periodontitis. Among patients with periodontitis, the survival rate was 100.0% in patients who received regular SPT and 89.2% for irregular SPT (p=0.012). These results suggest that regular SPT improves implant survival rate and is more effective in patients with periodontitis.

Treatment concepts for the posterior maxilla and mandible: short implants versus long implants in augmented bone

  • Thoma, Daniel Stefan;Cha, Jae-Kook;Jung, Ui-Won
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.1
    • /
    • pp.2-12
    • /
    • 2017
  • The aim of this narrative review is to describe treatment options for the posterior regions of the mandible and the maxilla, comparing short implants vs. longer implants in an augmented bone. The dental literature was screened for treatment options enabling the placement of dental implants in posterior sites with a reduced vertical bone height in the maxilla and the mandible. Short dental implants have been increasingly used recently, providing a number of advantages including reduced patient morbidity, shorter treatment time, and lower costs. In the posterior maxilla, sinus elevation procedures were for long considered to be the gold standard using various bone substitute materials and rendering high implant survival rates. More recently, implants were even placed without any further use of bone substitute materials, but the long-term outcomes have yet to be documented. Vertical bone augmentation procedures in the mandible require a relatively high level of surgical skill and allow the placement of standard-length dental implants by the use of autogenous bone blocks. Both treatment options, short dental implants, and standard-length implants in combination with vertical bone augmentation procedures, appear to result in predictable outcomes in terms of implant survival rates. According to recent clinical studies comparing the therapeutic options of short implants vs. long implants in augmented bone, the use of short dental implants leads to a number of advantages for the patients and the clinician.

Survival of surface-modified short versus long implants in complete or partially edentulous patients with a follow-up of 1 year or more: a systematic review and meta-analysis

  • Medikeri, Raghavendra Shrishail;Pereira, Marisca Austin;Waingade, Manjushri;Navale, Shwetambari
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.4
    • /
    • pp.261-281
    • /
    • 2022
  • Purpose: Short implants are a potential alternative to long implants for use with bone augmentation in atrophic jaws. This meta-analysis investigated the survival rate and marginal bone level (MBL) of surface-modified short vs. long implants. Methods: Electronic and manual searches were performed for articles published between January 2010 and June 2021. Twenty-two randomized controlled trials (RCTs) comparing surface-modified short and long implants that reported the survival rate with at least 1 year of follow-up were selected. Two reviewers independently extracted the data, and the risk of bias and quality of evidence were evaluated. A quantitative meta-analysis was performed regarding survival rate and MBL. Results: The failure rates of surface-modified short and long implants differed significantly (risk ratio, 2.28; 95% confidence interval [CI], 1.46, 3.57; P<0.000). Long implants exhibited a higher survival rate than short implants (mean follow-up, 1-10 years). A significant difference was observed in mean MBL (mean difference=-0.43, 95% CI, -0.63, -0.23; P<0.000), favoring the short implants. Regarding the impact of surface treatment in short and long implants, for hydrophilic sandblasted acid-etched (P=0.020) and titanium oxide fluoride-modified (P=0.050) surfaces, the survival rate differed significantly between short and long implants. The MBL differences for novel nanostructured calcium-incorporated, hydrophilic sandblasted acid-etched, and dual acid-etched with nanometer-scale calcium phosphate crystal surfaces (P=0.050, P=0.020, and P<0.000, respectively) differed significantly for short vs. long implants. Conclusions: Short surface-modified implants are a potential alternative to longer implants in atrophic ridges. Long fluoride-modified and hydrophilic sandblasted acid-etched implants have higher survival rates than short implants. Short implants with novel nanostructured calcium-incorporated titanium surfaces, hydrophilic sandblasted acid-etched surfaces, and dual acid-etched surfaces with nanometer-scale calcium phosphate crystals showed less marginal bone loss than longer implants. Due to high heterogeneity, the MBL results should be interpreted cautiously, and better-designed RCTs should be assessed in the future.

Finite Element Stress Analysis of Implant Prosthesis of Internal Connection System According to Position and Direction of Load (임플랜트-지대주의 내측연결 시스템에서 하중의 위치 및 경사에 따른 임플랜트 보철의 유한요소 응력분석)

  • Jang, Jong-Seok;Jeong, Yong-Tae;Chung, Chae-Heon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.21 no.1
    • /
    • pp.1-14
    • /
    • 2005
  • The purpose of this study was to assess the loading distributing characteristics of implant prosthesis of internal connection system(ITI system) according to position and direction of load, under vertical and inclined loading using finite element analysis (FEA). The finite element model of a synOcta implant and a solid abutment with $8^{\circ}$ internal conical joint used by the ITI implant was constructed. The gold crown for mandibular first molar was made on solid abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction (loading condition B), 200N at the centric cusp in a $15^{\circ}$ inward oblique direction (loading condition C), 200N at the in a $30^{\circ}$ inward oblique direction (loading condition D) or 200N at the centric cusp in a $30^{\circ}$ outward oblique direction (loading condition E) individually. Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment. The following results have been made based on this study: 1. Stresses were concentrated mainly at the ridge crest around implant under both vertical and oblique loading but stresses in the cancellous bone were low under both vertical and oblique loading. 2. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading than with the vertical loading. 3. An offset of the vertical occlusal force in the buccolingual direction relative to the implant axis gave rise to increased bending of the implant. So, the relative positions of the resultant line of force from occlusal contact and the center of rotation seems to be more important. 4. In this internal conical joint, vertical and oblique loads were resisted mainly by the implant-abutment joint at the screw level and by the implant collar. Conclusively, It seems to be more important that how long the distance is from center of rotation of the implant itself to the resultant line of force from occlusal contact (leverage). In a morse taper implant, vertical and oblique loads are resisted mainly by the implant-abutment joint at the screw level and by the implant collar. This type of implant-abutment connection can also distribute forces deeper within the implant and shield the retention screw from excessive loading. Lateral forces are transmitted directly to the walls of the implant and the implant abutment mating bevels, providing greater resistance to interface opening.

The oral microbiome of implant-abutment screw holes compared with the peri-implant sulcus and natural supragingival plaque in healthy individuals

  • MinKee Son;Yuri Song;Yeuni Yu;Si Yeong Kim;Jung-Bo Huh;Eun-Bin Bae;Won-Tak Cho;Hee Sam Na;Jin Chung
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.3
    • /
    • pp.233-244
    • /
    • 2023
  • Purpose: An implant-supported prosthesis consists of an implant fixture, an abutment, an internal screw that connects the abutment to the implant fixture, and the upper prosthesis. Numerous studies have investigated the microorganisms present on the implant surface, surrounding tissues, and the subgingival microflora associated with peri-implantitis. However, there is limited information regarding the microbiome within the internal screw space. In this study, microbial samples were collected from the supragingival surfaces of natural teeth, the peri-implant sulcus, and the implant-abutment screw hole, in order to characterize the microbiome of the internal screw space in healthy subjects. Methods: Samples were obtained from the supragingival region of natural teeth, the peri-implant sulcus, and the implant screw hole in 20 healthy subjects. DNA was extracted, and the V3-V4 region of the 16S ribosomal RNA was sequenced for microbiome analysis. Alpha diversity, beta diversity, linear discriminant analysis effect size (LEfSe), and network analysis were employed to compare the characteristics of the microbiomes. Results: We observed significant differences in beta diversity among the samples. Upon analyzing the significant taxa using LEfSe, the microbial composition of the implant-abutment screw hole's microbiome was found to be similar to that of the other sampling sites' microbiomes. Moreover, the microbiome network analysis revealed a unique network complexity in samples obtained from the implant screw hole compared to those from the other sampling sites. Conclusions: The bacterial composition of the biofilm collected from the implant-abutment screw hole exhibited significant differences compared to the supra-structure of the implant. Therefore, long-term monitoring and management of not only the peri-implant tissue but also the implant screw are necessary.

Distal-Extension Removable Partial Denture with Anterior Implant Prostheses: Case Report (전치부 임플란트 보철을 이용한 후방연장 국소의치 수복)

  • Na, Hyun-Joon;Kang, Dong-Wan;Son, Mee-Kyung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.4
    • /
    • pp.437-447
    • /
    • 2011
  • In patients who used removable partial dentures for a long period of time, gradual alveolar bone resorption occurs in edentulous area. However, in residual teeth area, alveolar bone is maintained sound. This causes an imbalance in intermaxillary distance between a maxillae and a mandible which is intensified due to expansion in vertical and horizontal bone amount difference between the two area as time passes. As the result, this shows a substantial difference in vertical position according to the period of teeth loss even after residual teeth loss. As in this situation, a patient with bilaterally and anterio-posteriorly different intermaxillary distance, various prosthodontic problems can be caused in fixed implant prosthodontics and implant overdenture. This study shows a case in which implant-supported removable partial denture was fabricated considering residual alveolar bone height after teeth loss in a patient who had been using a distal extension removable partial denture for a long period of time. In anterior area with short intermaxillary distance, fixed prosthodontics were fabricated with implant placement and in posterior area with long intermaxillary distance, a removable partial denture was fabricated. Finally, a small number of implants were placed without additional surgery and economical and comfortable treatment results were shown.

Retreatment of fractured implant overdenture due to long-term maintenance failure (장기간의 유지관리 실패로 인해 파절된 임플란트 피개의치 재수복 증례)

  • Kim, Minjee;Hong, Seoungjin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.3
    • /
    • pp.235-242
    • /
    • 2018
  • Periodontal and prosthodontic maintenance of implant overdenture is a very important factor for the long term success of the prosthesis and implants. Failure of maintenance can lead to prosthetic failure due to peri-implant bone loss and fracture and wear of the prosthesis or components. In this case, the existing gold milled bars were reconstructed with cobalt chrome milled bar in a manner that does not interfere with the external shape for the retreatment of fractured implant overdenture by maintenance failure. Two implants of mandible were selected strategically and the CM LOC attachments were connected to the two implants, and implant overdentures were fabricated. As a result, prosthesis with a functional and esthetic design that facilitates good hygiene management of the patient was delivered, which is advantageous for long term maintenance, and regular check-ups were scheduled for proper maintenance.