• Title/Summary/Keyword: long implant

Search Result 517, Processing Time 0.026 seconds

EFFECTS OF BONE ENGAGEMENT TYPE&IMPLANT LENGTH ON STRESS DISTRIBUTION: A THREE DIMENSIONAL FINITE ELEMENT ANALYSIS (임플란트 매식조건에 따른 상, 하악골의 응력분포 양상에 대한 3차원 유한요소분석 연구)

  • Choi, Jeong-Hwa;Seo, Ki-Youl;Choi, Joo-Ho;Han, Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.5
    • /
    • pp.687-697
    • /
    • 1999
  • A finite element analysis has been utilized to analyze stress and strain fields and design a new configuration in orthopedics and implant dentistry. Load transfer and stress analysis at implant bone interface are important factors from treatment planning to long term success. Bone configuration and quality are different according te anatomy of expecting implantation site. The purpose of this study was to compare the stress distribution in maxilla and mandible accord-ing to implant length and bone engagement types. A three dimensional axi-symmetric implant model(Nobel Biocare, Gothenburg, Sweden) with surrounding cortical and cancellous bone were designed to analyze the effects of bone engagement and implant length on stress distribution. ANSYS 5.5 finite element program was utilized as an interpreting toot. Three cases of unicortical anchorage model with 7, 10, 13 mm length and four cases of bicortical anchorage model with 5, 7, 10 and 13 mm length were compared both maxillary and mandibular single implant situation. Within the limits of study, following conclusions were drawn. 1. There is a difference in stress distribution according to cortical and cancellous bone thickness and shape. 2. Maximum stress was shown at the top of cortical bone area regardless of bone engagement types. 3. Bicortical engagement showed less stress accumulation when compared to unicortical case overall. 4. Longer the implant future length, less the stress on cortical bone area, however there is no difference in mandibular bicortical engagement case.

  • PDF

Implant-Supported Fixed Prostheses for the rehabilitation of distal free end in periodontally compromised dentitions Number of fixtures affecting bone tissue change (치주질환에 이환된 환자에서 구치 상실 치열 수복을 위한 임플란트 수복)

  • Yi, Seung-Won;Kim, Young-Soo
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.1
    • /
    • pp.53-63
    • /
    • 2005
  • Number of fixtures supporting prosthesis for rehabilitation of partial edentulism in distal area is an important factor in distal area to the bone tissue response around dental implant. Optimal number and optimal positioning of dental implant has leaded to the stable condition of bone tissue and successful long-term treatment outcome. This clinical and radiographic study was performed to document and evaluate the short-term result of occlusal rehabilitation by means of implant-supported fixed prostheses (ISPs) especially for partial edentulism in distal area in patients treated for advanced periodontal disease and to verify the number of fixture affecting the bone tissue response. A total of 30 consecutive patients referred because of advanced periodontal disease were included. Before the implant therapy was initiated, periodontal treatment was performed and the outcome evaluated during at least a 6-month period. An individual maintenance care program was designed for each patient. All 75 implants were placed using a 2-stage surgical approach. The patients were divided into 2 groups, in one of which two fixtures were placed and in the other of which three fixtures were placed with tripodal geometry. Following installation of the ISPs, all patients underwent a baseline examination including evaluation of i) oral hygiene, and ii) periodontal/ peri-implant conditions, and iii) radiographs. These examinations were repeated annually during the 1 or 2-year observation period. The results were as follows: 1.No single implant was lost during the observation follow-up period. 1.The percentage of plaque harboring surfaces and bleeding units upon probing were found to be low (<10%), and no soft tissue complications were recorded. 1.Two-fixture group showed bone destruction ranged from 0.0mm to 1.5mm and the mean was 0.31mm. Three-fixture group showed more bone destruction of 0.51mm. There was no statistically difference between two groups. These results suggested that the factor for success is not the number of fixture but the strict maintenance of peri-implant tissue health and initial stability of fixture.

The Effect of a Shock-Absorbable Polymer(Chitosan) on the Initial Stability and Dynamic Behavior of Dental Implant (충격흡수용 고분자재료의 이용이 Implant 초기안정성과 동적거동에 미치는 영향)

  • Joo, W.;Choi, K.;Kwon, I.C.;Choi, J.B.;Moon, H.J.;Shin, J.W.;Lee, Y.C.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.337-342
    • /
    • 1997
  • Dental implant has been increasingly used to recover the masticatory unction of tooth. It has been well known that the success of dental implant is heavily dependent on initial stability and long-term osseointegration due to optimal stress distribution in the surrounding bones. The role of periodontal ligament, removed during operation, is to absorb impact force and to distribute them to alveolar bone. or this reason, the study for artificial periodontal ligament has become an important issue in this field. In this study, chitosan was coated on dental implant or the purpose of replacing the role of intact periodontal ligament. The results by experiment and FEM analysis showed : I) Initial stability of dental implant was significantly increased(35%) when the implant was coated with chitosan. II) The coated implant showed higher impact absorption, more even stress distribution and lower stress magnitude under impact force than uncoated implant. Accordingly, the micro-fracture of the surrounding bones due to impact force would be lessened by chitosan coating on dental implant.

  • PDF

Comparison of stress distribution in bone and implant-supported dental prosthesis with zirconia and titanium implants: a 3-dimensional finite element analysis (지르코니아 및 티타늄 임플란트를 사용한 지지골 및 임플란트 유지 수복물의 응력 분포 비교: 3차원 유한 요소 분석)

  • Hong, Min-Ho
    • Journal of Technologic Dentistry
    • /
    • v.42 no.4
    • /
    • pp.348-354
    • /
    • 2020
  • Purpose: Zirconia is differentiated from other ceramics because of its high resistance to corrosion and wear, excellent flexural strength (900~1400 MPa), and high hardness. Dental zirconia with proven mechanical/biological stability is suitable for the manufacture of implants. However, there are limited in vivo studies evaluating stress distribution in zirconia compared with that in titanium implants and studies analyzing finite elements. This study was conducted to evaluate the stress distribution of the supporting bone surrounding zirconia and titanium implants using the finite element analysis method. Methods: For finite element analysis, a single implant-supported restoration was designed. Using a universal analysis program, eight occlusal points were set in the direction of the occlusal long axis. The occlusal load was simulated at 700 N. Results: The zirconia implant (47.7 MPa) von Mises stress decreased by 5.3% in the upper cortical bone compared with the titanium implant (50.2 MPa) von Mises stress. Similarly, the zirconia implant (20.8 MPa) von Mises stress decreased by almost 4% in the cancellous bone compared with the titanium implant (21.7 MPa) von Mises stress. The principal stress in the cortical and cancellous bone exhibited a similar propensity to von Mises stress. Conclusion: In the supporting bone, the zirconia implant is able to reduce bone resorption caused by mechanically transferred stress. It is believed that the zirconia implant can be a potential substitute for the titanium implant by reinforcing aesthetic characteristics and improving stress distribution.

Pontic site development with an implant submergence technique for unaesthetic implant in the anterior maxilla (상악 전치부 임플란트의 비심미성 개선을 위한 임플란트 침수(submergence)를 동반한 치조제 증대술)

  • Song, Yujeong;Lee, Ju-Youn
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.289-295
    • /
    • 2020
  • Improving implant esthetics is very difficult, especially in cases where unaesthetic problems are related to implants in the maxillary anterior dentition. A 69-year old male patient was referred by a prosthodontist for periodic pus discharge and an unaesthetic implant prosthesis (maxillary right lateral incisor). The implant was placed too deeply and showed soft tissue volume deficiency and a long clinical crown. After a clinical and radiographic examination, implant submergence and alveolar ridge augmentation were performed to enhance the aesthetics instead of an explantation. The treatment plan was as follows: extraction the adjacent teeth with tooth mobility, secondary caries, and poor prognosis; placement an additional dental implant with hard and soft tissue grafting; fabrication a fixed bridge using implant abutments. A fixed esthetic prosthesis using implants was fabricated, and the patient was satisfied with the prosthesis. A ridge augmentation with implant submergence may be an alternative for solving the problems of unaesthetic implant restorations in the esthetic zone.

Implant assisted removable partial denture with implant surveyed prostheses: A 9-year follow-up (임플란트 서베이드 보철물을 이용한 임플란트 보조 국소의치의 9년 경과 관찰 증례)

  • Lee, Jae-Rim;Yoon, Hyung-In;Kim, Hee-Sun;Sim, Hye-Young;Han, Yoon-Sic
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.211-221
    • /
    • 2022
  • Implant placement may be restricted by anatomical and/or financial limitations in restoring a completely edentulous arch, or the patients' unwillingness to have extensive surgical procedures. Implant assisted removable partial dentures (IARPD) in combination with anterior fixed implant prostheses can be proposed as an alternative treatment option for the restoration of a completely edentulous arch. In this case, a 56-year-old female patient who has a fully edentulous maxilla opposed by partially edentulous mandible was treated. The treatment option for the maxilla consisted of an implant-assisted removable partial denture supported by four anterior fixed implant prostheses. The mandible was restored with 8 anterior fixed partial dentures and posterior fixed implant-supported prostheses. Long-term follow-up and supportive periodontal treatment were performed for 9 years, and the patient was satisfied with the overall appearance as well as masticatory function.

Implant Maintenance Care (임프란트의 유지관리)

  • Jung, Jae-Jeon
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.8 no.1
    • /
    • pp.104-106
    • /
    • 1999
  • There has been a growing interest in implant among dentists and patients, recently. Maintenance of the implant and prothesis is the key factor for a long tern1 success. This article describes several methods for maintenance care which can be achieved with the cooperation of the patient and the dental staff members. By following this maintenance program I hope that our patient can enjoy their implants much more.

  • PDF

Guided bone regeneration using K-incision technique

  • Cho, Young-Dan;Ku, Young
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.3
    • /
    • pp.193-200
    • /
    • 2018
  • Purpose: The present study describes 3 patients with chronic periodontitis and consequent vertical resorption of the alveolar ridge who were treated using implant-based restoration with guided bone regeneration (GBR). Methods: After extraction of a periodontally compromised tooth, vertical bone augmentation using a K-incision was performed at the healed, low-level alveolar ridge. Results: The partial-split K-incision enabled soft tissue elongation without any change in buccal vestibular depth, and provided sufficient keratinized gingival tissue during GBR. Conclusions: Within the limits of this study, the present case series demonstrated that the novel K-incision technique was effective for GBR and allowed normal implant-based restoration and maintenance of a healthy periodontal condition. However, further long-term follow-up and a large-scale randomized clinical investigation should be performed to evaluate the feasibility of this technique.

Factors affecting the survival of implants: a long-term retrospective study (임플란트의 생존에 영향을 미치는 요인에 대한 장기간의 후향적 연구)

  • Song, Susanna;Lee, Jae-Kwan;Um, Heung-Sik;Chang, Beom-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.1
    • /
    • pp.10-19
    • /
    • 2015
  • Purpose: The aim of the present study was to evaluate the long-term survival of implants retrospectively and determine the risk factors associated with implant failure. Materials and Methods: Of all implants that were placed at the Department of Periodontology of the Dental Hospital of Gangneung-Wonju National University from January 1998 to December 2012, 2265 implants that were followed up until June 2013 were included in this study. Data were collected from clinical and radiographic examinations from previous visits. The information gathered included gender, age, smoking status, implant diameter, implant length, surface of implant, location of implant within the dental arch, surgical techniques and existence of complications. Results: The survival rate before loading was 98.9%. The cumulative survival rate after 5 years of loading was 97.2%, and after 15 years of loading was 95.2%. In a simple logistic regression analysis, gender (P = 0.016), smoking status (P = 0.001), location of implant (P = 0.020) and existence of complications (P = 0.002) were statistically associated with implant failure and included in the multiple regression analysis. As a result of multiple logistic regression analysis, the variables statistically associated with implant failure (P < 0.05) were smoking status (P = 0.049) and existence of complications (P < 0.001). Conclusion: The cumulative survival rate of dental implants after 15 years of loading was 95.2% and that the variables statistically associated with implant failure were smoking status and existence of complications.

The Study of Bone Formation around Titanium Implants Placed in Adrenalectomized Rat's Tibia (부신 제거 백서에 티타늄 임플랜트 매식후 주위 골형성에 관한 연구)

  • Choi, Kab-Lim;Kim, Jong-Ryoul;Park, Bong-Soo;Sung, Iel-Yong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.22 no.3
    • /
    • pp.274-287
    • /
    • 2000
  • The use of dental implants has increased tremendously in recent years and is expected to increase even more in the future. The successful outcome of any implant procedure is surely dependent on interrelationship of the various components of an equation that includes biocompatibility of implant material, macroscopic and microscopic nature of the implant surface, the status of implant bed, surgical technique, undisturbed healing phase and subsequent prosthetic design and long-term loading phase. The purpose of this study was to clarify the effects of adrenalectomy on the osseointegration of pure titanium implants. Seventy rats, 11 weeks of age, were divided into two groups : an adrenalectomized group and a control group. Titanium screw implant(diameter, 2.0mm; length, 3.5mm) was placed into left tibia of 70 rats, 35 in control group and 35 in the experimental group. The rats were sacrificed at different time interval (1, 2, 3, 4, 6, 8, and 12 weeks after implantation) for histopathologic observation, histomorphometric analysis and immunohistochemistry with fibronectin and CD44 antibody. The results obtained from this study were as follows: 1. Histopathogically, findings, newly formed bone was seen at 3 weeks control group and became lamellar bone at 12 weeks. At 6 weeks, lipocytes were observed in bone marrow space. Thickness of regenerated trabecular bone increased till 6 weeks after then, that decreased gradually. 2. By histomorphometric analysis, marrow bone density and contact ratio of marrow bone to implant decreased significantly from 8 to 12 weeks in experimental group compared to control group and also total bone to implant contact ratio decreased significantly from 4 to 12 weeks in experimental group compared to control group. 3. Fibronectin immunoreactivity was very strong at 3 and 4 weeks control group. And after that reduced gradually. But it was continuously strong from 1 to 12 weeks experimental group. 4. CD44 immunoreactivity was very strong in the newly formed osteoblasts at 3 and 4 weeks control group. But it reacted minimally later. However, it reacted continuously strong from 3 to 12 weeks experimental group. From these results, bone to implant contact ratio decreased gradually from 4 weeks in adrenalectomized group compared to control group. CD44 and fibronectin immunoreactivities were strong at all times in adrenalectomized rats. Therefore, it could be stated that immature bone remained continuously for a long time and not readily proceeded into mature status.

  • PDF