• Title/Summary/Keyword: lod

Search Result 739, Processing Time 0.031 seconds

The development and validation of a novel liquid chromatography tandem mass spectrometry (LC-MS/MS) procedure for the determination of fluoroquinolones residues in chicken muscle using modified QuEChERS (quick, easy, cheap, effective, rugged and safe) method

  • Park, Sunjin;Kim, Hyobi;Choi, Byungkook;Hong, Chung-Oui;Lee, Seon-Young;Jeon, Inhae;Lee, Su-Young;Kwak, Pilhee;Park, Sung-Won;Kim, Yong-Sang;Lee, Kwang-jick
    • Korean Journal of Veterinary Service
    • /
    • v.42 no.4
    • /
    • pp.289-296
    • /
    • 2019
  • A novel rapid procedure with liquid chromatography tandem mass spectrometry (LC-MS/MS) detection has been developed by changing various conditions including sample preparation such as QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) methodology. This work has been involved the optimization and validation of detection method for fluoroquinolones which are widespread used in livestock especially in the chicken. Five grams of homogenized chicken muscle were extracted with QuEChERS EN and acetonitrile containing 5% formic acid and cleaned with anhydrous magnesium sulfate and C18 sorbent. The separation was performed on Acquity UPLC HSS T3 (2.1 mm×100 mm, 1.8 ㎛) column. The mobile phase A and B were composed of water containing 0.1% formic acid and acetonitrile containing 0.1% formic acid, respectively. Flow rate was 0.25 mL/min and column temperate was 40℃. LC-MS/MS with multiple reaction monitoring has been optimized for ten fluoroquinolones (ciprofloxacin, danofloxacin, difloxacin, enrofloxacin, marbofloxacin, norfloxacin, ofloxacin, orbifloxacin, pefloxacin and sarafloxacin). The method developed in this study has been presented good linearity with correlation coefficient (R2) of 0.9971~0.9998. LOD and LOQ values ranged from 0.09 to 0.76 ppb and from 0.26 to 2.29 ppb, respectively. The average recoveries were from 77.46 to 111.83% at spiked levels of 10.0 and 20.0 ㎍/kg. Relative standard deviation (%) ranged 1.28~11.90% on intra-day and 3.10~8.38 % on inter-day, respectively. This analysis method was applicable to the livestock residue laboratories and was expected to be satisfactory for the residue surveillance system.

Simultaneous Determination of Aflatoxins and Ochratoxin A in Pork by LC-MS/MS (LC-MS/MS를 이용한 돼지고기 중 총아플라톡신 및 오크라톡신 A 동시분석법 확립)

  • Paek, Ockjin;Park, Songyi;Park, Ki Hun;Kim, Sheen-Hee;Suh, Saejung;Yoon, Hae Jung
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.3
    • /
    • pp.194-200
    • /
    • 2016
  • Aflatoxins and ochratoxin A (AFTs and OTA) are secondary fungal metabolites produced by several moulds, mainly by Aspergillus flavus by Aspergillus ochraceus and Penicillium verrucosum, and these toxins can be transferred to animals and humans through the ingestion of contaminated feed and food. This study was to develop the analytical method for determination the levels of AFTs ($B_1$, $B_2$, $G_1$ and $G_2$) and OTA in pork. The AFTs and OTA were analyzed simultaneously by electrospray ionization in positive ion mode and mass reaction monitoring (MRM) after solid phase extract (SPE) columns clean-up. Performance characteristics, such as accuracy, precision, linear range, limit of detection (LOD) and quantification (LOQ), were also determined. Matrix-matched standard calibration was used for quantification, obtaining the recoveries in the range of 67.3~108.2% with the relative standard deviations of < 20%. Limits of detection and quantification were also estimated, obtaining the limits of quantification ranged in $0.7{\sim}1.3{\mu}g/kg$. The results of the inter-day study, which was performed with pork samples for 3 days, showed an accuracy of 92.0~109.9%. The precisions (expressed as relative standard deviation values) for the inter day variation were 2.6~17.8%. The method developed in this study was able to carry out the analysis with the satisfactory intensity and accuracy.

System Design for a Urban Energy Monitoring and Visualization Environment Using Ubiquitous Sensor Network and Social Sensor Networking (Ubiquitous Sensor Network 및 Social Sensor Networking을 이용한 도시 에너지 모니터링 가시화 시스템 설계)

  • Choe, Yoon;Jang, Myeong-Ho;Kim, Sung-Ah
    • Journal of the HCI Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.7-14
    • /
    • 2010
  • Urban Data collected through Sensor Network is becoming crucial to understand and analyse a city. Thus, the Ubiquitous Sensor Network builds the foundation of the u-City development. This research aims to develop an energy monitoring application with an intuitive visualization environment which integrates energy usage information on top of urban geospatial information. Such a system will be able to facilitate effective energy supply plan at the early stages of urban planning, and eventually to encourage citizens to conserve energy by giving them real time monitoring information in an easy to understand visual environment. The system provides multiple layers of energy-related information coupled with the geospatial information layer in order to accommodate multiple viewpoints. On the other hand, the system provides logical Level of Detail control based on urban spatial information hierarchy. We defined the system concept and functions, and designed the data structure and the methods of information visualization. This paper presents the visualization methods, data structure, interactions scenarios which combines spacial information, E-GIS data and the energy related sensor data. Furthermore this research tries to introduce the concept of Social Sensor Networking to enhance the monitoring quality.

  • PDF

Determination of fucoxanthin in cosmeceutical products by HPLC-PDA (HPLC-PDA를 이용한 기능성 화장품 중 푸코잔틴의 정량)

  • Choi, Jongkeun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.755-761
    • /
    • 2017
  • This study was conducted to establish an analytical method using an HPLC system equipped with a photodiode array (PDA) detector for the quality control of raw materials and cosmeceuticals containing fucoxanthin as an active ingredient. The column was octadecyl-functionalized silica gel and the measurement wavelength of the PDA was set to 499 nm. To validate the analytical method, the linearity of the calibration curve, detection limit, reproducibility and recovery rate were investigated and good results were obtained. The correlation coefficient of the calibration curve was 1.000 and the linearity was good in the concentration range of 0.5 ~ 100 ppm. Moreover, the limit of detection (LOD) was 0.1 ppm and the limit of quantification (LOQ) was 0.5 ppm. The results of the peak reproducibility test used for evaluating the system suitability showed that the RSD (n = 5) of the peak area was 2.0% and that of the retention time was 0.09%. In the spiking test, the recovery rate was $101.6{\pm}0.77%$. The fucoxanthin contents of the two kinds of fucoxanthin-containing raw materials were $49.6{\pm}3.3%$ and $1.03{\pm}0.016%$, respectively. In addition, the fucoxanthin content in the test product, which was intended to be 150 ppm, was $156.7{\pm}4.7ppm$. From the above results, it was concluded that this method could be applied to the quantitative analysis of fucoxanthin in cosmeceuticals.

Trace level analysis of Pb in plasma by inductively coupled plasma/mass spectrometry (유도결합플라즈마 질량분석법을 이용한 혈장 중 극미량 납 분석)

  • Lee, Sung-Bae;Yang, Jeong-Sun;Choi, Sung-Bong;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.190-196
    • /
    • 2012
  • The human exposure of lead has usually detected the amount of lead in the whole blood, however, this method has a shortcoming to give the information on the short-term exposure to lead. In that sense, it is desirable to estimates the level of lead in plasma to draw the chronic bio-marker of lead exposure even though it is difficult to measure lead of several ng/L. An inductively coupled plasma-mass spectrometry (ICP-MS) method was developed for determining lead in plasma as the chronic bio-marker of lead of workers. To minimize the contamination of lead from the environment, we constructed class 1,000 clean room and compared the amount of floating dust before and after the operation of the clean room. The limit of detection (LOD) and the limit of quantification (LOQ) of lead in fetal bovine serum were 4.3 ng/L and 12.2 ng/L by NIOSH method (statistical calculation method) and 7.0 ng/L and 22.1 ng/L by signal/noise ratio, respectively. The accuracy was in a range of 92.3-101.3%, and the precision of the assay was less than 4% in the samples spiked in the concentration of 20 ng/L and 2,000 ng/L. The method was simple, reproducible and sensitive enough to permit reliable analysis of lead to the ng/L level in plasma and/or serum. The method was also useful for the biological monitoring of chronic exposure to lead.

Analysis of Biurea Decomposed from Azodicarbonamide in Food Products by High Performance Liquid Chromatography Mass/Mass Spectrometry (LC/MS/MS를 이용한 식품 중 아조디카르본아미드 분해산물인 Biurea 함량 분석)

  • Lim, Ho-Soo;Pahn, Kyeong-Nyeo;Kim, Jun-Hyun;Jang, Gui-Hyeon;Moon, Gui-Im;Yang, Hyo-Jin;Park, Sung-Kwan;Park, Hae-Kyong;Kim, So-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.4
    • /
    • pp.377-382
    • /
    • 2010
  • This study was conducted to establish a method to analyze biurea decomposed from azodicarbonamide in processed foods such as wheat flour and bread. New method was developed using high performance liquid chromatography mass/mass spectrometry to determine biurea in wheat flour and bakery products. The recovery rate was 94.3-112.5%. The limit of detection for biurea was 0.003 mg/kg, and the limit of quantification was 0.01 mg/kg. The monitoring results for biurea content using established methods showed that biurea was detected at 2.76 mg/kg in the azodicarbonamide-detected flour (detection rate, 2%). The detection rate in processed foods such as baked goods was 27% (16/59). The detection range was 0.19-18.01 mg/kg (average, 3.79 mg/kg). However, it was thought that the detection level was safe due to much lower values than the standard (45 mg/kg). As a result, the newly established biurea analytical method will contribute to the management of azodicarbonamide in processed foods such as wheat flour and bakery products.

Analytical Method Development and Monitoring of Residual Solvents in Dietary Supplements (건강기능식품 중 잔류용매 분석법 개발 및 모니터링)

  • Lee, Hwa-Mi;Shin, Ji-Eun;Jang, Young-Mi;Kim, Hee-Yun;Kim, Mee-Hye
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.4
    • /
    • pp.390-397
    • /
    • 2010
  • Residual solvents in foods are defined as organic volatile chemicals used or produced in manufacturing of extracts or additives, or functional foods. The solvents are not completely eliminated by practical manufacturing techniques and they also may become contaminated by solvents from packing, transportation or storage in warehouses. Because residual solvents have no nutritional value but may be hazardous to human health, there is a need to remove them from the final products or reduce their amounts to below acceptable levels. The purpose of this study was to develop and evaluate an analytical method for the screening of residual solvents in health functional foods. Furthermore, the aim of this study was to constitute a reasonable management system based on the current state of the market and case studies of foreign countries. Eleven volatile solvents such as MeOH, EtOH, trichloroethylene and hexane were separated depending on their column properties, temp. and time using Gas Chromatography (GC). After determining the GC conditions, a sample preparation method using HSS (Head Space Sampling) was developed. From the results, a method for analyzing residual solvents in health functional foods was developed considering matrix effect and interference from the sample obtained from the solution of solvents-free health functional foods spiked with 11 standards solutions. Validation test using the developed GC/HSS/MS (Mass Spectrometry) method was followed by tests for precision, accuracy, recovery, linearity and adequate sensitivity. Finally, examination of 104 samples grouped in suits was performed by the developed HSS/GC/MS for screening the solvents. The 11 solvents were isolated from health functional foods based on vapor pressure difference, and followed by separation within 15 minutes in a single run. The limt of detection (LOD), limit of quantification (LOQ), recovery and coefficient of variation (C.V.) of these compounds determined by the HSS/GC/MS were found to be 0.1 pg/mL, 0.1-125 pg/g, 51.0-104.6%, and less than 15%, respectively. Using the developed HSS/GC/MS method, residual solvent from 16 out of 104 health functional products were detected as a EtOH. This method therefore seems t o be a valuable extension ofanalytical method for the identification of residual solvents in health functional food.

Determination of Polycyclic Aromatic Hydrocarbons in Processed Chestnut Products (밤가공품 중 polycyclic aromatic hydrocarbons 함량 분석)

  • Seo, Il-Won;Nam, He-Jung;Kim, Dong-Hyuk;Shin, Han-Seung
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.3
    • /
    • pp.339-344
    • /
    • 2009
  • Concentrations of polycyclic aromatic hydrocarbon (PAH) in processed chestnut products were determined by HPLC/FLD. The methodology involved procedures of sonication with water, extraction with hexane, and clean-up on a Sep-pak florisil cartridge. The PAH limits of detection (LOD) and limits of quantitation (LOQ) ranged from 0.012 to 0.382 ${mu}g/kg$ and from 0.042 to 1.273 ${mu}g/kg$, respectively. The coefficients of variation for intra- and inter-day assays were 0.02-4.48% and 0.37-9.83%, respectively, and the accuracies were 81.95-125.44% and 79.89-116.53%, respectively. The overall recoveries for eight PAHs spiked into the processed chestnut products ranged from 87.83 to 100.56%. As a result, PAH contents were not detected in the processed chestnut products.

Analysis of Florfenicol in Meats (식육 중 항생제 florfenicol의 분석)

  • Kuk, Ju-Hee;Song, Young-Me;Bae, Min-Seok;Go, Myoung-Jin;Yoo, Myung-Sang;An, Eun-Suk;Park, Eun-Heui;Go, Myoung-Jin;Kang, Kil-Jin
    • Journal of Food Hygiene and Safety
    • /
    • v.23 no.4
    • /
    • pp.319-323
    • /
    • 2008
  • Analytical method for determination of florfenicol was developed for estimate veterinary drug residue of unestablished MRLs in meat. The method was validated in correspondence with the CODEX guideline for florfenicol residue in meat. The samples mixed with sodium sulfate were extracted with ethyl acetate. After clean-up, the residue was dissolved in mobile phase and analyzed using high-performance liquid chromatography with fluorescence detector. The calibration curve showed good linearity($r^2=0.9997$) within the concentration range of $0.05{\sim}1.0\;mg/kg$. The limit of detection(LOD) and limit of quantification(LOQ) were validated at 0.012 and 0.039 mg/kg, respectively. The recoveries in fortified meat ranged from 85.6 to 95.6%($1.1{\sim}5.3%$ RSD) at the 0.05 to 0.4 spiking levels. We monitored 150 samples of meats that were purchased in Korea(Seoul, Busan, Daegu, Daejeon and Gwangju). Among tested samples, florfenicol was detected in 1 of pig at the level of 0.040 mg/kg, and below LOQ in 1 of cattle, 2 of pig and 2 of chicken. The residues of florfenicol in the tested samples were within the MRLs.

Simultaneous Determination of Quinolones in Flatfish and Egg Using liquid Chromatography with Fluorescence Detection (액체크로마토그래피를 이용한 광어 및 계란 중 퀴놀론계의 동시분석법 개발)

  • Lee, Sang-Hee;Shim, You-Shin;Kim, Hyun-Ju;Choi, Yoon-Hee;Shin, Dong-Bin
    • Journal of Food Hygiene and Safety
    • /
    • v.23 no.4
    • /
    • pp.324-329
    • /
    • 2008
  • An analytical method for the simultaneous determination of nine quinolones (QNs) namely, marbofloxacin, norfloxacin(IS), ciprofloxacin, danofloxacin, enrofloxacin, sarafloxacin, difloxacin, oxolinic acid, and flumequine in flatfish and egg was developed and validated using liquid chromatography with fluorescence detection (LC-FD). The samples were extracted using a traditional liquid-liquid extraction process; deproteinization was accomplished by the addition of trichloroacetic acid and acetonitrile (ACN), and defatting was performed with hexane. Chromatographic separation was achieved on a reverse phase C8 column with gradient elution using a mobile phase of 200 mM ammonium acetate buffer (pH 4.5) and ACN. The proposed method was validated according to the CODEX guideline. Mean recoveries of QNs from flatfish and egg were 89.6-106.5% with relative standard deviations (RSDs) below 15% at three different concentrations of 50, 100 and $500{\mu}g/kg$. Linearity was obtained with a correlation coefficient ($r^2$) of 0.9989-1.0000. The LOD for the investigated QNs was $1-16{\mu}g/kg$ depending on flatfish and egg. The present method can be applied simultaneously to determine QNs in muscle of flatfish and egg.