• Title/Summary/Keyword: localized failure

Search Result 171, Processing Time 0.024 seconds

Characteristics of the Horizontal Stress and the Possibility of Stress Induced Brittle Failure in Chuncheon-Yanggu Mountainous Region by the In-situ Stress Measurements (현장 측정에 의한 춘천-양구 산악지역 내 수평응력 분포와 취성파괴 가능성에 관한 연구)

  • Bae Seongho;Jeon Seokwon
    • Tunnel and Underground Space
    • /
    • v.15 no.2 s.55
    • /
    • pp.157-167
    • /
    • 2005
  • Current initial rock stress state is one of the key factors required to evaluate the stability and failure around an excavated opening and its importance increases as the construction depth become deeper and the scale of the rock structure become larger. In this paper, the study was performed to evaluate the characteristics of the regional stress state at Chuncheon-Yanggu mountainous region, the East-North part of Kyeonggi Massif. Forty nine field stress measurements in 9 boreholes were conducted at the depth from 20 m to 290 m by hydraulic fracturing method. The fracturing tracing works were carried out by acoustic televiewer scanning. The study results revealed that the different intial rock stress states presented at different formation rock type and the excessive horizontal stress state with stress ratio(K) close to 3.0 was measured at the depth of 200 m and deeper in the intrusive unite body of the study area. The results from the investigation of excessive horizontal stress and its effect on failure mode showed that there exist several points where the localized excessive horizontal stresses are big enough to potentially induce brittle failures around the future openings greater than 100 m in depth within the granite body of the study area.

A Study of Localization for Adiabatic Shear Band in WHA(Tungsten Heavy Alloy) (텅스텐 중합금의 단열전단밴드 형성 및 국부화에 대한 연구)

  • Hwang, Doo-Son;Hong, Sung-In
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.6
    • /
    • pp.18-25
    • /
    • 2007
  • In a plastic metal forming of thermally rate-sensitive material, the localized shear band stems from evolution of a narrow region in which intensive plastic flow occurs. And it give rise to fatal fracture with plastic instability. The objectives of this study are to investigate the localization behavior by using numerical method and predict the failure for WHA(Tungsten Heavy Alloy). In this work, the implicit finite difference scheme is used because of the advantage about convergence and the numerical stability. This study is based on an analysed material with hardening as well as thermally softening behavior which includes isotropic strain hardening and observed the extension of localization within shear band according to material properties.

A simplified method for evaluation of shear lag stress in box T-joints considering effect of column flange flexibility

  • Doung, Piseth;Sasakia, Eiichi
    • Structural Engineering and Mechanics
    • /
    • v.73 no.2
    • /
    • pp.167-179
    • /
    • 2020
  • This study provides a simplified method for the evaluation of shear lag stress in rectangular box T-joints. The occurrence of shear lag phenomenon in the box T-joint generates stress concentration localized at both web-flange junctions of the beam, which leads to cracking or failure in the weld region of the joint. To prevent such critical circumstance, peak stress at the weld region is required to be checked during a preliminary design stage. In this paper, the shear lag stresses in the T-joints were evaluated using least-work solution in which the longitudinal displacements of the beam flange and web were presumed. The evaluation process considered particularly the effect of column flange flexibility, which was represented by an axial spring model, on the shear lag stress distribution. A simplified method for stress evaluation was provided to avoid solving complex mathematical problems using a stress modification factor βs from a parametric study. The results showed that the proposed method was valid for predicting the shear lag stress in the box T-joints manually, as well compared with finite element results. The results are further summarized, discussed, and clarified that more flexible column flange caused higher stress concentration.

High temperature rupture lifetime of 304 stainless steel under multiaxial stress states (다축응력상태에서의 304 스테인리스강의 고온 파괴수명에 관한 연구)

  • Kim, Ho-Kyung;Chung, Kang;Chung, Chin-Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.3
    • /
    • pp.595-602
    • /
    • 1998
  • Specimens of 304 stainless steel were tested to failure at elevated temperatures under multiaxial stress states, uniaxial tension using smooth bar specimens, biaxial shearing using double shear bar specimens, and triaxial tension using notched bar specimens. Rupture times are compared for uniaxial, biaxial, and triaxial stress states with respect to the maximum principal stress, the von Mises effective stress, and the principal facet stress. The results indicate that the principal facet stress gives the best correlation for the material investigated, and this parameter can predict creep life data under multiaxial stress states with rupture data obtained with specimens under uniaxial stresses. The results also suggest that grain boundary cavitation, coupled with localized deformation processes such as grain boudary sliding, controls the lifetimes of the specimens.

Diagnostics and Prognostics Based on Adaptive Time-Frequency Feature Discrimination

  • Oh, Jae-Hyuk;Kim, Chang-Gu;Cho, Young-Man
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.9
    • /
    • pp.1537-1548
    • /
    • 2004
  • This paper presents a novel diagnostic technique for monitoring the system conditions and detecting failure modes and precursors based on wavelet-packet analysis of external noise/vibration measurements. The capability is based on extracting relevant features of noise/vibration data that best discriminate systems with different noise/vibration signatures by analyzing external measurements of noise/vibration in the time-frequency domain. By virtue of their localized nature both in time and frequency, the identified features help to reveal faults at the level of components in a mechanical system in addition to the existence of certain faults. A prima-facie case is made via application of the proposed approach to fault detection in scroll and rotary compressors, although the methods and algorithms are very general in nature. The proposed technique has successfully identified the existence of specific faults in the scroll and rotary compressors. In addition, its capability of tracking the severity of specific faults in the rotary compressors indicates that the technique has a potential to be used as a prognostic tool.

Deterministic Fracture Mechanics Analysis of Nuclear Reactor Pressure Vessel Under Rot Leg Leak Accident (고온관 누설에 의한 가압열충격 사고시 원자로 용기의 건전성 평가를 위한 결정론적 파괴역학 해석)

  • Lee, Sang-Min;Choi, Jae-Boong;Kim, Young-Jin;Park, Youn-Won;Jhung, Myung-Jo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.11
    • /
    • pp.2219-2227
    • /
    • 2002
  • In a nuclear power plant, reactor pressure vessel (RPV) is the primary pressure boundary component that must be protected against failure. The neutron irradiation on RPV in the beltline region, however, tends to cause localized damage accumulation, leading to crack initiation and propagation which raises RPV integrity issues. The objective of this paper is to estimate the integrity of RPV under hot leg leaking accident by applying the finite element analysis. In this paper, a parametric study was performed for various crack configurations based on 3-dimensional finite element models. The crack configuration, the crack orientation, the crack aspect ratio and the clad thickness were considered in the parametric study. The effect of these parameters on the maximum allowable nil-ductility transition reference temperature ($(RT_{NDT})$) was investigated on the basis of finite element analyses.

Surgical treatment of pulmonary aspergillosis (폐 Aspergillosis 의 외과적 치료)

  • 유회성
    • Journal of Chest Surgery
    • /
    • v.17 no.2
    • /
    • pp.269-274
    • /
    • 1984
  • Since tuberculosis was a common pulmonary disease in Korea, Aspergillosis was easily misdiagnosed as tuberculosis and an acute form of Aspergillosis was misinterpreted as pneumonia because of their similarities in the X-ray findings. This investigation is designed to illustrate the clinical features and preoperative diagnosis and surgical role in the management of this disease. In a retrospective review of operative cases from Jan. 1963 through Dec. 1983, 36 cases were analyzed. Peak age incidence lies in the 3rd decade [41.7%]. All cases had a history of treatment with antituberculous drugs under diagnosis of pulmonary tuberculosis and the most common chief complaint was hemoptysis [69.5%]. Only nine cases [25%] showed cavitary lesions with mycetoma and preoperative sputum study for fungus showed low positive valve [42.3%]. Anatomical location of lesion was located mainly upper lobe [66.7%] and most of cases were managed by lobectomy. We experienced 7 cases of complication; they were postoperative empyema, hepatic failure, esophageal varix bleeding. Postoperative pathologic findings showed that 29 cases [80.5%] were combined with tuberculosis 3 cases were combined with bronchiectasis and 4 cases were not combined with other disease. In conclusion, when the patient has a longstanding history of pulmonary tuberculosis and has a hemoptysis, he must be suspected fungus super infection. Resectional surgery is the treatment of choice for symptomatic localized disease and needed resection in asymptomatic patient to prevent possible fatal sequelae in the future.

  • PDF

A Study on the Spalling Properties of High-Performance Concrete with the Kinds of Aggregate and Polypropylene Fiber Contents (골재종류 및 폴리프로필렌 섬유 혼입률 변화에 따른 고성능 콘크리트의 폭열 특성에 관한 연구)

  • 한천구;양성환;이병렬;황인성
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.5
    • /
    • pp.69-77
    • /
    • 1999
  • A spalling is defined as the damages of concrete exposed to high temperature during the fire by causing cracks and localized bursting of small pieces of concrete. It is reported that spalling is caused by the vapor pressure and polypropylene(PP) fiber has an important role in protecting from spalling. This paper is a study on the properties and spalling resistance of high-performance concrete with the kinds of aggregate and the contents of PP fiber. According to the experimental results, concrete contained no PP fiber take place in the form of the surface spalling and the failure of specimenns after fire test regardless of the kinds of aggregate. Concrete contained more than 0.05% of PP fiber with the aggregate of basalt does not take place the spalling, while the concrete using granite and limestone does the surface spalling. It is found that residual compressive strength after exposed at high temperature has 50~60% of its original strength. Although specimens after exposed at high temperature is cured at water for 28days, they do not recover their original strength.

Finite element modelling of self-supported transmission lines under tornado loading

  • Altalmas, A.;El Damatty, A.A.
    • Wind and Structures
    • /
    • v.18 no.5
    • /
    • pp.473-495
    • /
    • 2014
  • Localized wind events, in the form of tornadoes and downbursts, are the main cause of the large number of failure incidents of electrical transmission line structures worldwide. In this study, a numerical model has been developed to study the behaviour of self-supported transmission lines under various tornado events. The tornado wind fields used were based on a full three-dimensional computational fluid dynamics analysis that was developed in an earlier study. A three-dimensional finite element model of an existing self-supported transmission line was developed. The tornado velocity wind fields were then used to predict the forces applied to the modelled transmission line system. A comprehensive parametric study was performed in order to assess the effects of the location of the tornado relative to the transmission line under F2 and F4 tornado wind fields. The study was used to identify critical tornado configurations which can be used when designing transmission line systems. The results were used to assess the sensitivity of the members' axial forces to changes in the location of the tornado relative to the transmission line. The results were then used to explain the behaviour of the transmission line when subjected to the identified critical tornado configurations.

Circumferential Resection and Reconstruction of The Mediastinal Trachea Without Prosthesis for Tracheal Stenosis: A Report of 4 Cases (기관삽입관에 의한 기관협착증 의 외과적 치료: 4례 보고)

  • 박주철
    • Journal of Chest Surgery
    • /
    • v.10 no.1
    • /
    • pp.17-24
    • /
    • 1977
  • The present treatment of respiratory failure, using cuffed endotracheal and tracheostomy tube has produced, apparently with increasing frequency, three lesions which have serious ceminical manifestations such as tracheal stenosis, tracheomalasia, and localized tracheal erosion. Extensive resection and reconstruction of the trachea must be necessary because conservative treatment has generally failed in the fully developed stenotic lesion. of the mediastinal trachea following extensive resection is best accomplished by direct anastomosis of the patient`s own tracheobronchial tissue. Any replacement of the mediastinal trachea must be air tight and laterally rigid, and must heal dependably. A variety of materials has been used for substitution following circumferential excision of tracheal segments within the mediastinum. These attempts have often failed because of early leak or late stenosis. We have successfully performed circumferential resection and primary end-to-end anastomosis of the trachea for 4 cases of post-intubation tracheal stenosis located a few centimeter below the tracheostomy stoma in the period of 3 years between 1974 and 1976. The lesion in one patient was found in the upper trachea which was approached anteriorly through a cervicomediastinal incision with division of the upper sternum. Other three located in the lower half of the trachea were operated through a high transthoracic incision with appropriate hilar mobilization in addition to cervical flexion for the development of the cervical trachea into the mediastinum. There were no hospital death, but suture line granulations occurred in two patients were managed by bronchoscopic removal of granulations without difficulties.

  • PDF