• 제목/요약/키워드: local panel

검색결과 333건 처리시간 0.024초

Maximum Power Point Tracking under Partial Shading condition

  • Kashif, Muhammad Fayyaz;Park, Yongsoon;Sul, Seung-Ki
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 추계학술대회
    • /
    • pp.40-41
    • /
    • 2011
  • Partial shading on a Photo Voltaic panel can generate the local maximum power points on the powervoltage curve of the panel. Presence of the local peaks can disturb the efficient operation of maximum power point tracking (MPPT).In this study, the MPPT under partial shading condition is investigated. To circumvent the trappings into the local peaks, the results of the study are enumerated and discussed.

  • PDF

틸팅 차량용 적층재의 차음성능 평가 (An Estimation of the Sound Insulation Performance of the Multi-layered Panel for a Tilting Train)

  • 서태건;임봉기;김석현;김재철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.597-600
    • /
    • 2009
  • Sound transmission loss (TL) is experimently investigated on the multi-layered panel used for the floor of a tilting train. Measurement of the intensity transmission loss is performed according to ASTM E 2249-02. The floor structure consists of corrugated steel panel, glass wool, plywood and cover. On the corrugated steel panel, TL drop by local resonance is considered and the TL improvement effect by damping treatment is estimated. Total sound transmission loss of the entire floor structure is obtained and the contribution of each layer is examined.

  • PDF

차세대 고속철도 차량 적층 구조의 차음성능 (Sound Insulation Performance of the Layered Structure of the Next Generation High Speed Train)

  • 이중혁;김석현
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.326-331
    • /
    • 2011
  • Aluminum extruded panel used in a high speed train shows high stiffness, however, its sound insulation performance is remarkably decreased by local resonance phenomena. In this paper, improvement strategy of the sound insulation performance is proposed for the floor extruded panel used in HEMU-400x, 400km/h class next generation high speed train under development, and the improvement effect is verified by experiment. Aluminum extruded panel specimen for the floor is manufactured and urethane foam is installed in the core of the panel. Based on ASTM E2249-02, intensity transmission loss is measured and the improvement effect in local resonance frequency band is verified. Finally, improvement effect of the sound insulation performance is estimated on the layered floor structure including the foamed aluminum panel.

  • PDF

Hysteretic performance of a novel composite wall panel consisted of a light-steel frame and aerated concrete blocks

  • Wang, Xiaoping;Li, Fan;Wan, Liangdong;Li, Tao
    • Steel and Composite Structures
    • /
    • 제41권6호
    • /
    • pp.861-871
    • /
    • 2021
  • This study aims at investigating the hysteretic performance of a novel composite wall panel fabricated by infilling aerated concrete blocks into a novel light-steel frame used for low-rise residential buildings. The novel light-steel frame is consisted of two thin-wall rectangular hollow section columns and a truss-beam assembled using patented U-shape connectors. Two bare light-steel frames and two composite wall panels have been tested to failure under horizontal cyclic loading. Hysteretic curves, lateral resistance and stiffness of four specimens have been investigated and analyzed. Based on the testing results, it is found that the masonry infill can significantly increase the lateral resistance and stiffness of the novel light-steel frame, about 2.3~3 and 21.2~31.5 times, respectively. Failure mode of the light-steel frame is local yielding of the column. For the composite wall panel, firstly, masonry infill is crushed, subsequently, local yielding may occur at the column if loading continues. Hysteretic curve of the composite wall panel obtained is not plump, implying a poor energy dissipation capacity. However, the light-steel frame of the composite wall panel can dissipate more energy after the masonry infill is crushed. Therefore, the composite wall panel has a much higher energy dissipation capacity compared to the bare light-steel frame.

Wire Rope Isolator 마운팅 수동 조작 패널의 진동 저감 (Vibration Reduction for a Local Operation Panel Mounted by Wire Rope Isolator)

  • 김재실;김동일;허종대;황재덕
    • 한국기계가공학회지
    • /
    • 제13권6호
    • /
    • pp.127-133
    • /
    • 2014
  • This paper reviews a finite element model of a wire rope isolator (WRI) via an experimental comparison test. A local operation panel (LOP) mounted on a WRI is modeled using a finite element method. Mode analyses and harmonic analyses are conducted while varying of the thickness of the rope for the WRI. A feasible WRI can be selected considering the reduction of the vibration and the total weight of the LOP system.

알미늄 압출재의 차음 구조 설계 (Design of Aluminium Extruded Panel for Sound Insulation)

  • 서태건;김석현;김정태;송달호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.996-999
    • /
    • 2010
  • Aluminium extruded panel is the most important element for sound insulation in a express train. However, comparing with the flat plate with the same weight, the extruded panel shows remarkably low sound transmission loss above the 1st local resonance frequency, which is determined by the dimension of the core structure. Preceding study showed the possibility of the improvement of sound insulation performance by properly designing the core dimension. By the proper core design, local resonance frequency shifts to higher frequency region without any reduction of bending or torsional strength and without any weight increase. Based upon this result, this study investigates in detail the design modification of the core structure of the aluminium extruded panel used in a express train under development, in aspect of sound insulation. Design result is compared with those of other developed models.

  • PDF

Analysis of Local Tax Performance Through Tax Capacity and Tax Effort in Indonesia 2014-2018

  • RAFSANJANI, Ali Hadi;AGUSTINA, Neli
    • Asian Journal of Business Environment
    • /
    • 제12권2호
    • /
    • pp.43-53
    • /
    • 2022
  • Purpose: This study aims to analyze the performance of local taxes in Indonesia through the estimation of tax capacity and tax effort, as well as classifying provinces based on the estimated value of tax capacity and tax effort. Research design, data and methodology: this study uses panel data of 34 provinces in Indonesia for the period of 2014-2018. The analytical method used in the tax capacity model is panel data regression to explain the factors that influence tax performance. Tax effort is estimated by the ratio of tax to tax capacity. Results: The results of the analysis show that gini ratio and regional expenditures have a significant positive effect on the tax ratio, while the share of GRDP in the manufacturing sector and HDI has a significant negative effect on the tax ratio. Based on the results, there are 19 provinces that have low tax capacity and 16 provinces that have low tax effort. Conclusions: The development of local tax performance tends to fluctuate with an average of 1.24 percent per year. Gini ratio and regional expenditure have a significant positive effect on the tax ratio, while the share of GRDP in the manufacturing sector and HDI have a significant negative effect on the tax ratio.

흡음 및 댐핑재 의한 주름강판의 차음성능 개선효과 (Improvement Effect of the Sound Insulation Performance of the Corrugated Steel Panel by Sound Absorbing and Damping Materials)

  • 김석현;서태건;김정태
    • 한국철도학회논문집
    • /
    • 제13권5호
    • /
    • pp.476-480
    • /
    • 2010
  • 철도차량의 바닥재에 널리 사용되는 주름 강판은 국부공진 효과에 의하여 특정 주파수 대역에서의 차음성능이 심각하게 저하된다. 그 대책으로, 본 연구에서는 우레탄 폼재를 주름내부에 충진시키거나 유리면층을 바닥재에 적층시킨 후, 차음성능의 향상효과를 실험적으로 평가한다. 주름강판 및 바닥 적층재를 대상으로 ASTM E2249-02에 근거하여 인텐시티 투과손실을 측정하고 평가한다. 본 연구의 목적은 폼 충진이나 유리면 적층이 중량 증가 측면에서 열차 차체의 차음성능을 어느 정도 향상시키는가를 규명하는 데에 있다.

Impact of Railroads on Local Economies: Evidence from U.S. History

  • Kim, Jiyoung;Go, Sun
    • 유통과학연구
    • /
    • 제15권4호
    • /
    • pp.25-32
    • /
    • 2017
  • Purpose - The introduction and expansion of the railway network since the 19th century brought revolutionary changes in economic activities, performance, and structure. The purpose of this study is estimating the impact of railroads on the local agricultural and manufacturing structures in the 19th century USA. Research design, data, and methodology - To identify the impact of railroads on local economic structure, county-level panel data from the U.S. census were analyzed using a panel fixed-effect differences-in-differences regression. The empirical investigation focuses on whether railroads changed the overall volume and sectoral composition of the local agricultural sector, and whether they contributed to the growth of the local manufacturing industry and its productivity. Results - The railroad introduction led to the relative decline of the agricultural sector, while encouraging the growth of market-oriented gardening. As such, manufacturing productivity increased by the introduction of railroads, although manufacturing inputs and home manufactures were unaffected. Conclusions - The findings imply that railroads contributed to the growth of market-oriented farming in rural areas, and the rise of productivity in the local manufacturing sector. Meanwhile, evidence of railroad-driven growth for the entire agricultural sector or a massive reallocation of resources from agriculture to manufacturing were not found.

국부 경화 열처리된 차체 부품의 기계적 성질과 미세조직에 관한 연구 (A Study on Mechanical Properties and Microstructure of Local-Hardening Heat-Treated Automotive Panel)

  • 이재호;정우창
    • 열처리공학회지
    • /
    • 제23권6호
    • /
    • pp.301-308
    • /
    • 2010
  • A steel with chemical composition, 0.22% C, 0.25% Si, 1.26% Mn, 0.22% Cr, 0.04% Ti, 0.0042% B, and a microstructure of ferrite and spheroidized cementite has been press-formed to automotive center pillar followed by local-hardening heat-treatment. Hardness, tensile properties, fractography, microstructure and surface roughness of local-hardening heat-treated automotive center pillar have been examined. The directly heated and quenched area had fully martensitic structure with Vickers hardenss in the range of 500 to 510. The heat affected area close to the directly heated area showed dual-phase structure of ferrite and martensite. The width of the heat-treated and heat-affected areas after the local-hardening heat treatment was ranging from 32 mm to 50 mm. The surface of the local-hardening heat-treated center pillar revealed some temper color as a consequence of the oxidation during the heat treatment, but the surface roughness was not affected by the local-hardening heat treatment.