• 제목/요약/키워드: local energy

검색결과 1,961건 처리시간 0.035초

An edge-based smoothed finite element method for adaptive analysis

  • Chen, L.;Zhang, J.;Zeng, K.Y.;Jiao, P.G.
    • Structural Engineering and Mechanics
    • /
    • 제39권6호
    • /
    • pp.767-793
    • /
    • 2011
  • An efficient edge-based smoothed finite element method (ES-FEM) has been recently developed for solving solid mechanics problems. The ES-FEM uses triangular elements that can be generated easily for complicated domains. In this paper, the complexity study of the ES-FEM based on triangular elements is conducted in detail, which confirms the ES-FEM produces higher computational efficiency compared to the FEM. Therefore, the ES-FEM offers an excellent platform for adaptive analysis, and this paper presents an efficient adaptive procedure based on the ES-FEM. A smoothing domain based energy (SDE) error estimate is first devised making use of the features of the ES-FEM. The present error estimate differs from the conventional approaches and evaluates error based on smoothing domains used in the ES-FEM. A local refinement technique based on the Delaunay algorithm is then implemented to achieve high efficiency in the mesh refinement. In this refinement technique, each node is assigned a scaling factor to control the local nodal density, and refinement of the neighborhood of a node is accomplished simply by adjusting its scaling factor. Intensive numerical studies, including an actual engineering problem of an automobile part, show that the proposed adaptive procedure is effective and efficient in producing solutions of desired accuracy.

Mid-IR Luminosity Functions of Local Galaxies in the North Ecliptic Pole Field

  • Kim, Seong Jin;Lee, Hyung Mok;Jeong, Woong-Seob
    • 천문학회보
    • /
    • 제40권1호
    • /
    • pp.72.3-72.3
    • /
    • 2015
  • We present the mid-infrared (MIR) luminosity function (LF) of local (z < 0.3) star forming (SF) galaxies based on the AKARI's NEP-Wide Survey data. We utilized a combination of the NEP-Wide point source catalogue containing a large number (114,000) of infrared (IR) sources distributed over the wide (5.4 sq. deg) field and spectroscopic redshift (z) data for 1790 selected targets obtained by optical follow-up surveys with MMT/Hectospec and WIYN/Hydra. The AKARI's continuous $2{\sim}24{\mu}m$ wavelength coverage and the spectroscopic redshifts for sample galaxies enable us to derive accurate spectral energy distributions (SEDs) in the mid-infrared. We carried out SED-fit analysis and employed 1/Vmax method to derive the mid-IR (e.g., $8{\mu}m$, $12{\mu}m$, and $15{\mu}m$ rest-frame) luminosity functions. Our results for local galaxies from the NEP region generally consistent with various previous works for other fields over wide luminosity ranges. The comparison with the results of the NEP-Deep data implies the luminosity evolution from higher redshifts towards the present epoch. We attempted to fit our derived LFs to the double power-laws and present the resulting power indices. We also examined the correlation between mid-IR luminosity and total IR luminosity.

  • PDF

결정질 태양전지의 국부적 후면 전극 형성에서 접합 면적에 따른 전기적 특성분석 연구 (A study on local back contact of crystalline solar cell according for electrical specific analysis research in junction area)

  • 장주연;송규완;이준신
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.56.2-56.2
    • /
    • 2010
  • 국부적 후면 전극(LBC)형성은 결정질 실리콘 태양전지에서 고효율과 저가화를 동시에 달성할 수 있는 기술이다. 후면 표면 passivation과 국부적 후면 전극 형성을 통해서 후면 재결합 속도를 낮출 수 있고 이를 통해 효율향상을 기대해볼 수 있다. 본 연구에서는 PECVD를 이용한 LBC(local back contact) cell의 후면 passivation 박막을 형성하였고 접합면적에 따른 전기적 특성을 분석해 보았다. LBC cell을 위한 후면 passivation 박막은 PECVD를 이용한 ONO박막을 사용하였고, 후면 opening 형성에 etching paste를 이용하였다. Opening size는 0.4mm,0.5mm,0.7mm로 형성하여 cell을 제작하고 효율을 분석하였다. 실험결과 opening size가 0.4mm일때 전극의 접촉면적이 15.96%, 0.5mm일때 10.22%, 0.7mm일때 5.17%로 형성됨을 확인할 수 있었다. Opening size가 0.4mm일 때 cell의 효율이 가장 우수함을 IQE 및 LIV 결과를 통해 확인 할 수 있었다. 결과적으로 접촉면적이 증가함에 따라 전극에서 수집되는 carrier의 양이 증가하고 셀 효율역시 향상됨을 확인 할 수 있었다.

  • PDF

결정질 태양전지 국부적 후면 접촉 Passivation에 따른 특성 연구 (A study on Characteristics of crystalline solar cell on local back contact according to passivation)

  • 김현엽;최재우;이준신
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.122.2-122.2
    • /
    • 2011
  • 결정질 태양전지 제작에서, passavtion은 표면의 반사도를 줄여주는 반사 방지막의 역할과 표면의 dangling bond를 감소시켜, 표면 재결합 속도를 줄이고 minority carrier lifetime을 증가하는 데 큰 영향을 미친다. 그렇기 때문에 저가형 고효율 태양전지 제작에서 우수한 특성을 가지는 passivation막은 매우 중요한 이슈이다. 본 연구에서는 LBC(local back contact) 구조를 가지는 단결정 태양전지 후면에, 기존의 Full Al-BSF의 passivation 막을 SiNx와 ONO passivation 막으로 각각 대체하여, LBC 구조에서 더 적합한 passivation 막을 찾고자 하였다. SiNx와 ONO passivation 막은 단결정 LBC 구조 태양전지 후면에 각각 형성되었고 $800^{\circ}C$, 20 sec 조건으로 소성되었다. 실험결과는 minority carrier lifetime과 surface recombination velocity로 관찰하였다. 그 결과, SiNx passivation 막의 표면 재결합 속도는 29.7cm/s이고, ONO passivation 막의 표면 재결합 속도는 24.5cm/s로, Full Al-BSF 표면 재결합 속도 750cm/s에 비해 더 적합한 passivation 막으로 확인할 수 있었다. 결과적으로 SiNx,ONO passivation 막이 Full Al-BSF보다 전극에 수집되는 캐리어의 양이 많아짐에 따라 효율향상을 가져올 수 있을 것이다.

  • PDF

인지 통신에서 1차 사용자의 판단 시간을 줄이기 위한 Or 기법의 연구 (A Study of the Or rule to reduce decision time of Primary User at the Cognitive radio)

  • 최문근;공형윤
    • 한국인터넷방송통신학회논문지
    • /
    • 제10권5호
    • /
    • pp.161-166
    • /
    • 2010
  • 기존의 OR 법칙은 각각의 2차 사용자가 검출한 결과 값을 퓨전센터에서 취합하여 1차 사용자의 존재 유무를 판단한다. 따라서 기존의 OR 법칙은 1차 사용자의 존재 유무를 판단하기 위해서 CR 네트워크 내에 존재하는 모든 2차 사용자로부터 검출 결과 값을 취합하여야 했다. 하지만 본 논문을 통해 제안하는 OR 법칙은 2차 사용자의 검출 결과 값에 따라 퓨전센터에서 취합하는 2차 사용자의 검출 결과 값의 수를 조절하여 2차 사용자의 전송 용량을 높일 수 있다. 그리고 본 논문을 통해 제안하는 OR 법칙의 시뮬레이션을 통해 기존의 OR 법칙과 제안하는 OR 법칙의 오 경보 확률, 미 검출 확률을 구하고 전송 용량을 구한다.

국소적 초음파 가진이 난류경계층에 미치는 영향 (Influence of Local Ultrasonic Forcing on a Turbulent Boundary Layer)

  • 박영수;성형진
    • 한국가시화정보학회지
    • /
    • 제3권1호
    • /
    • pp.78-89
    • /
    • 2005
  • An experimental study was carried out to investigate the effect of local ultrasonic forcing on a turbulent boundary layer. Stereoscopic particle image velocimetry (SPIV) was used to probe the characteristics of the flow. A ultrasonic forcing system was made by adhering six ultrasonic transducers to the local flat plate. Cavitation which generates uncountable minute air-bubbles having fast wall normal velocity occurs when ultrasonic was projected into water. The SPIV results showed that the wall normal mean velocity is increased in a boundary layer dramatically and the streamwise mean velocity is reduced. The skin friction coefficient (C$_{f}$) decreases 60$\%$and gradually recovers at the downstream. The ultrasonic forcing reduces wall-region streamwise turbulent intensity, however, streamwise turbulent intensity is increased away from the wall. Wall-normal turbulent intensity is almost the same near the wall but it increases away from the wall. In the vicinity of the wall, Reynold shear stress, sweep strength and production of turbulent kinetic energy were decreased. This suggests that the streamwise vortical structures are lifted by ultrasonic forcing and then skin friction is reduced.

  • PDF

Structural Steel as Boundary Elements in Ductile Concrete Walls

  • Cho, Soon-Ho
    • KCI Concrete Journal
    • /
    • 제12권2호
    • /
    • pp.73-84
    • /
    • 2000
  • A new form of construction utilizing structural steel as the boundary elements in ductile flexural concrete walls is proposed to solve the bar congestion problems in such a heavily reinforced region, while maintaining the ductility and energy absorption capacity comparable to their traditional form. Two wall specimens containing rectangular hollow structural sections (HSS) and channels at their ends respectively, and one companion standard reinforced concrete wall specimen with concentrated end reinforcement were constructed and tested under reversed cyclic loading to evaluate the construction process as well as the structural performance. Initially, all three specimens were chosen and detailed with some caution to have approximately the same flexural capacity without change of the original shape and dimension of a rectangular cross section correction. Analysis and comparison of test results indicated that the reversed cyclic responses of three walls showed similar hysteretic properties, but in those with steel boundaries, local buckling of the corresponding steel webs and flanges following significant yielding was a dominant factor to determine the hysteretic response. The monotonic and cyclic responses predicted based on a sectional approach was also presented and found to be in good agreement with measured results. Design recommendations considering local instability of the structural steel elements and the interaction between steel chords and a concrete web member in such a composite wall are presented.

  • PDF

난류유동의 Large-Eddy Simulation 기법의 알고리즘 향상에 관한 연구 (Improvement on Large-Eddy Simulation Technique of Turbulent Flow)

  • 앙경수
    • 대한기계학회논문집
    • /
    • 제19권7호
    • /
    • pp.1691-1701
    • /
    • 1995
  • Two aspects of Large-Eddy Simulation(LES) are investigated in order to improve its performance. The first one is on how to determine the model coefficient in conjunction with a dynamic subgrid-scale model, and the second one is on a wall-layer model(WLM) which allows one to skip near-wall regions to save a large number of grid points otherwise required. Especially, a WLM suitable for a separated flow is considered. Firstly, an averaging technique to calculate the model coefficient of dynamic subgrid-scale modeling(DSGSM) is introduced. The technique is based on the concept of local averaging, and useful to stabilize numerical solution in conjunction with LES of complex turbulent flows using DSGSM. It is relatively simple to implement, and takes very low overhead in CPU time. It is also able to detect the region of negative model coefficient where the "backscattering" of turbulence energy occurs. Secondly, a wall-layer model based on a local turbulence intensity is considered. It locally determines wall-shear stresses depending on the local flow situations including separation, and yields better predictions in separated regions than the conventional WLM. The two techniques are tested for a turbulent obstacle flow, and show the direction of further improvements.rovements.

기장 향토 음식의 조리표준화(제2보) - 미역설치, 몰설치, 기장우묵, 섞박지 - (Recipe Standardization of Native Local Foods in Gijang Region(The Second Report) - Miyeokseolchi, Molseolchi, Gijangumuk, Seokbakji -)

  • 김소미;임지애
    • 한국조리학회지
    • /
    • 제13권4호
    • /
    • pp.220-231
    • /
    • 2007
  • This study was designed to standardize the recipes of native local foods in Gijang region such as 'Miyeokseolchi', 'Molseolchi', 'Gijangumuk' and 'Seokbakji' and analyze their nutrients. The test recipe for each food was prepared according to the information obtained from the personal interview of Gijang natives and then applied to sensory evaluation. After that, CAN pro 3.0 was used for the nutritional evaluation. The results are as follows: Both Miyeokseolchi and Molseolchi were preferred with soybean sprouts added but Miyeokseolchi with fermented red pepper paste added. Gijangumuk was preferred with dissolved ceylon moss added, not filtered. Seokbakji was preferred with salt-fermented gizzard shad added. Nutrient analysis was performed according to the established standard recipe. In general, it appeared that energy content was low and amino acid contents such as glutamate, aspartic acid, leuicine and arginine were high. Major fatty acids in Miyeokseolchi and Molseolchi were a linoleic acid and Seokbakji has a palmitic acid and EPA.

  • PDF

멀티에이전트 시스템을 이용한 마이크로그리드 분산 지능형 관리시스템 파일럿 플랜트 개발 (Development of Pilot Plant for Distributed Intelligent Management System of Microgrids)

  • 오상진;유철희;정일엽;임재봉
    • 전기학회논문지
    • /
    • 제62권3호
    • /
    • pp.322-331
    • /
    • 2013
  • This paper describes the development of the pilot plant of distributed intelligent management system for a microgrid. For optimal control and management of microgrids, intelligent agents area applied to the microgrid management system. Each agent includes intelligent algorithms to make decisions on behalf of the corresponding microgrid entity such as distributed generators, local loads, and so on. To this end, each agent has its own resources to evaluate the system conditions by collecting local information and also communicating with other agents. This paper presents key features of the data communication and management of the developed pilot plant such as the construction of mesh network using local wireless communication techniques, the autonomous agent coordination schemes using plug-and-play functions of agents and contract net protocol (CNP) for decision-making. The performance of the pilot plant and developed algorithms are verified via real-time microgrid test bench based on hardware-in-the-loop simulation systems.