• 제목/요약/키워드: local energy

검색결과 1,961건 처리시간 0.031초

Multi-measuring기법을 이용한 원전 제어밸브의 누설진단 (Leakage Monitoring of Control Valves for Nuclear Power Plants Using Multi-measuring)

  • 김성영;김영범;김봉호;이상국
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3458-3463
    • /
    • 2007
  • Leakage would happen because of the damage of high temperature and high-pressure valve in nuclear power plant. condition based prevention maintenance is essential by using the suitable method based on local condition. Energy loss prevention can prevent from an accurate test, Local actually and ability. The methods of test for high energy fluid leakage at present are analysis of ${\Delta}$T, AE(Acoustic Emission) analysis, and thermal image. The result for test of AC (Main steam) system in YNG 2 Unit reveals that the AE occurred clearly in leakage situation, but thermal image didn't occur. It is identified that leakage is occurred when the orifice located front and back of valve operates. It shows that making a impatient judgment by using the single method if it is leakage is containing uncertainty. So I think that using the Multi-Measuring method is more sound judgment than Single-Measuring method.

  • PDF

튜브배열 변화에 따른 직교류형 열교환기의 성능에 관한 연구 (A Study on the Performance of a Cross-Flow Beat Exchanger by Tube Array Change)

  • 전용한;김남진;김종보
    • 에너지공학
    • /
    • 제15권1호
    • /
    • pp.28-34
    • /
    • 2006
  • 고온의 연소가스를 교란시키고 열교환 요소와 오랜시간 접촉하도록 원관을 옆으로 서로 맞대어 붙인 후 이 원관의 배열과 수직한 방향으로 연소가스가 흐르도록 설계된 열교환기에 대하여 실험적으로 열전달특성을 조사하기 위해서 유동이 충분히 발달한 영역에서 관 외부 원주방향으로 스테인레스 박판을 부착하고 직류 전원공급기를 통해 열유속을 주어, 관 주위의 대류열전달계수를 측정하였다. 실험 결과 세로피치 0.075 m, 가로피치 0.08 m이고 엇갈림 배열일 때 열전달계수가 15% 정도 차이가 크게 났으며, 레이놀즈수가 증가할수록 열전달계수도 증가함을 알 수 있었다. 또한 전체 평균 누셀트 수도 엇갈림 배열이 정렬배열에 비해 높게 나타났다.

냉각수 온도에 따른 수분류 충돌제트의 열전달 특성 연구 (Effect of Cooling Water Temperature on Heat Transfer Characteristics of Water Impinging Jet)

  • 이정호;유청환;도규형
    • 열처리공학회지
    • /
    • 제23권5호
    • /
    • pp.249-256
    • /
    • 2010
  • Water jet impingement cooling has been widely used in a various engineering applications; especially in cooling of hot steel plate of steelmaking processes and heat treatment in hot metals as an effective method of removing high heat flux. The effects of cooling water temperature on water jet impingement cooling are primarily investigated for hot steel plate cooling applications in this study. The local heat flux measurements are introduced by a novel experimental technique that has a function of high-temperature heat flux gauge in which test block assemblies are used to measure the heat flux distribution during water jet impingement cooling. The experiments are performed at fixed flow rate and fixed nozzle-to-target spacing. The results show that effects of cooling water temperature on the characteristics of jet impingement heat transfer are presented for five different water temperatures ranged from 5 to $45^{\circ}C$. The local heat flux curves and heat transfer coefficients are also provided with respect to different boiling regimes.

Active Contour Model을 이용한 임의의 물체 윤곽선 추출 (Arbitrary Object Contour Extraction using Active Contour Model)

  • 문창수;유봉길;오승재;정종필;전희정
    • 한국컴퓨터정보학회논문지
    • /
    • 제4권4호
    • /
    • pp.77-85
    • /
    • 1999
  • 본 논문은 Kass가 제안한 수식을 수정했다. 첫 번째로, 물체의 내부나 외부에 초기 값을 설정할 수 있도록 하였으며, 물체의 윤곽선을 보다 빨리 쉽게 추출할 수 있고 에지가 강한 곳으로 움츠려드는 것을 개선하였다. 두 번째로 내부에너지 수식을 개선하였고, $3{times}3$ 행렬을 사용하였다. 세 번째로 에너지 항을 부과하여 한 점에 모이는 현상을 처리했고, 임계값을 사용하여 윤곽선을 정확하게 추출하도록 알고리즘을 수정하였다. 알고리즘을 수정한 결과, 초기 값을 쉽게 설정했고 높은 곡률의 물체도 추출했다. 피드백시스템을 사용하여 처리속도를 개선했다.

  • PDF

PREDICTION OF A HEAT TRANSFER TO CO2 FLOWING IN AN UPWARD PATH AT A SUPERCRITICAL PRESSURE

  • Cho, Bong-Hyun;Kim, Young-In;Bae, Yoon-Yeong
    • Nuclear Engineering and Technology
    • /
    • 제41권7호
    • /
    • pp.907-920
    • /
    • 2009
  • This study was performed to evaluate the prediction capability of a commercial CFD code and to investigate the effects of different geometries such as a 4.4 mm tube and an 8/10 mm annular channel on the detailed flow structures. A numerical simulation was performed for the conditions, at which the experimental data was produced by the test facility SPHINX. A 2-dimensional axisymmetric steady flow was assumed for computational simplicity. The RNG $\kappa-\varepsilon$ turbulence model (RNG) with an enhanced wall treatment option, SST $\kappa-\omega$ (SST) and low Reynolds Abid turbulence model (ABD) were employed and the numerical predictions were compared with the experimental data generated from the experiment. The effects of the geometry on heat transfer were investigated. The flow and temperature fields were also examined in order to investigate the mechanism of heat transfer near the wall. The local heat transfer coefficient predicted by the RNG model is very close to the measurement result for the tube. In contrast, the local heat transfer coefficient predicted by the SST and ABD models is closer to the measurement for the annular channel.

Visual Tracking of Objects for a Mobile Robot using Point Snake Algorithm

  • Kim, Won;Lee, Choon-Young;Lee, Ju-Jang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1998년도 제13차 학술회의논문집
    • /
    • pp.30-34
    • /
    • 1998
  • Path Planning is one of the important fields in robot technologies. Local path planning may be done in on-line modes while recognizing an environment of robot by itself. In dynamic environments to obtain fluent information for environments vision system as a sensing equipment is a one of the most necessary devices for safe and effective guidance of robots. If there is a predictor that tells what future sensing outputs will be, robot can respond to anticipated environmental changes in advance. The tracking of obstacles has a deep relationship to the prediction for safe navigation. We tried to deal with active contours, that is snakes, to find out the possibilities of stable tracking of objects in image plane. Snakes are defined based on energy functions, and can be deformed to a certain contour form which would converge to the minimum energy states by the forces produced from energy differences. By using point algorithm we could have more speedy convergence time because the Brent's method gives the solution to find the local minima fast. The snake algorithm may be applied to sequential image frames to track objects in the images by these characteristics of speedy convergence and robust edge detection ability.

  • PDF

바이오매스 순환단지조성을 위한 거버넌스 구축방안 연구 (A Study of the Efficient Planning of Governance for Building Biomass Circulation Estate)

  • 권구중;이수영;황재현
    • 한국유기농업학회지
    • /
    • 제22권4호
    • /
    • pp.561-579
    • /
    • 2014
  • This research estimates the necessity of a better governance plan on the purpose of fulfillment energy recovery by building resource recycling system for biomass resources and waste resources that derive from agricultural and mountain village areas. The utilization of new renewable energy technology which uses waste and biomass sources diverse as variety of resources, collecting method, operator etc. and is structurally complicated the formation of policy is also very difficult. There is failure because of the problems which occurs from the policy led by government. Biomass Town Development Project should be made through the central government and the local government integrated support system and should be formed a consultative group in order to process the project mutually with these two department including the experts from the related areas. This consultative group, while government organizations carry out the hub function of strategic knowledge management, should carry out the control tower function to be able to be net working transfer the information with the cooperation of private and government so vitalize the communication area among the related actors. And to be able to increase the participation rate of the local people the consistent and various educations should be given so a smooth business promotion progress will be desired through the change of perception and coactive participation of people.

Hysteretic performance of a novel composite wall panel consisted of a light-steel frame and aerated concrete blocks

  • Wang, Xiaoping;Li, Fan;Wan, Liangdong;Li, Tao
    • Steel and Composite Structures
    • /
    • 제41권6호
    • /
    • pp.861-871
    • /
    • 2021
  • This study aims at investigating the hysteretic performance of a novel composite wall panel fabricated by infilling aerated concrete blocks into a novel light-steel frame used for low-rise residential buildings. The novel light-steel frame is consisted of two thin-wall rectangular hollow section columns and a truss-beam assembled using patented U-shape connectors. Two bare light-steel frames and two composite wall panels have been tested to failure under horizontal cyclic loading. Hysteretic curves, lateral resistance and stiffness of four specimens have been investigated and analyzed. Based on the testing results, it is found that the masonry infill can significantly increase the lateral resistance and stiffness of the novel light-steel frame, about 2.3~3 and 21.2~31.5 times, respectively. Failure mode of the light-steel frame is local yielding of the column. For the composite wall panel, firstly, masonry infill is crushed, subsequently, local yielding may occur at the column if loading continues. Hysteretic curve of the composite wall panel obtained is not plump, implying a poor energy dissipation capacity. However, the light-steel frame of the composite wall panel can dissipate more energy after the masonry infill is crushed. Therefore, the composite wall panel has a much higher energy dissipation capacity compared to the bare light-steel frame.

Ductile capacity study of buckling-restrained braced steel frame with rotational connections

  • Mingming Jia;Jinzhou He;Dagang Lu
    • Steel and Composite Structures
    • /
    • 제46권3호
    • /
    • pp.417-433
    • /
    • 2023
  • The maximum ductility and cumulative ductility of connection joints of Buckling-Restrained Braced Frames (BRBF) are critical to the structural overall performance, which should be matched with the BRB ductility. The two-story and one-span BRBF with a one-third scale was tested under cyclic quasi-static loading, and the top-flange beam splice (TFBS) rotational connections were proposed and adopted in BRBF. The deformation capacity of TFBS connections was observed during the test, and the relationship between structural global ductility and local connection ductility was studied. The rotational capacity of the beam-column connections and the stability performance of the BRBs are highly relevant to the structural overall performance. The hysteretic curves of BRBF are stable and full under large displacement demand imposed up to 2% story drift, and energy is dissipated as the large plastic deformation developed in the structural components. The BRBs acted as fuses and yielded first, and the cumulative plastic ductility (CPD) of BRBs is 972.6 of the second floor and 439.7 of the first floor, indicating the excellent energy dissipation capacity of BRBs. Structural members with good local ductility ensure the large global ductility of BRBF. The ductile capacity and hysteretic behavior of BRBF with TFBS connections were compared with those of BRBF with Reduced Beam Section (RBS) connections in terms of the experimental results.

Techno-economic design of a grid-tied Photovoltaic system for a residential building

  • Asad A. Naqvi;Talha Bin Nadeem;Ahsan Ahmed;Muhammad Uzair;S. Asad Ali Zaidi
    • Advances in Energy Research
    • /
    • 제8권1호
    • /
    • pp.59-71
    • /
    • 2022
  • Increasing cost of electricity due to rising price of fuel is one of the local community's main issues. In this research, switching of grid dependent system to the grid-tied Photovoltaic (PV) system with net metering for a residential building is proposed. The system is designed by considering the maximum energy demand of the building. The designed system is analyzed using RETScreen on technical, economic and environmental grounds. It is found that the system is able to produce 12,000 kWh/year. The system is capable to fulfill the electricity demand of the building during day time and is also capable to sell the energy to the local grid causing the electric meter to run in reverse direction. During night time, electricity will be purchased from grid, and electric meter will run in the forward direction. The system is economically justified with a payback period of only 3 years with net present value of PKR. 4,758,132. Also, the system is able to reduce 7.2 tons of CO2 not produced in the entire life of the project.