• 제목/요약/키워드: local distance

검색결과 1,122건 처리시간 0.033초

Performance Analysis of Local Network PPP-RTK using GPS Measurements in Korea

  • Jeon, TaeHyeong;Park, Sang Hyun;Park, Sul Gee
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제11권4호
    • /
    • pp.263-268
    • /
    • 2022
  • Precise Point Positioning-Real Time Kinematic (PPP-RTK) is a high accuracy positioning method that combines RTK and PPP to overcome the limitations on service coverage of RTK and convergence time of PPP. PPP-RTK provides correction data in the form of State Space Representation (SSR), unlike RTK, which provides measurement-based Observation Space Representation (OSR). Due to this, PPP-RTK has an advantage that it can transmit less data than RTK. So, recently, several techniques for PPP-RTK have been proposed. However, in order to utilize PPP-RTK techniques, performance analysis of these in a real environment is essential. In this paper, we implement the local network PPP-RTK and analyze the positioning performance according to the distance within 100 km from the reference station in Korea. As results of experiment, the horizontal and vertical 95% errors of local network PPP-RTK were 6.25 cm and 5.86 cm or less, respectively.

국소영역에서 이동표적의 상대위치 측정 장치 개발 (Development of Relative Position Measuring Device for Moving Target in Local Area)

  • 서명국
    • 드라이브 ㆍ 컨트롤
    • /
    • 제17권4호
    • /
    • pp.8-14
    • /
    • 2020
  • Intelligent devices using ICT technology have been introduced in the field of construction machinery to improve productivity and stability. Among the intelligent devices, Machine Guidance is a device that provides real-time posture, location, and work range to drivers by installing various sensors, controllers, and satellite navigation systems on construction machines. Conversely, the efficiency of equipment that requires location information, such as machine guidance, will be greatly reduced in buildings, and tunnels in the GPS blind spots. Thus, the other high-precision positioning technologies are required in the GPS blind spot zone. In this study, we will develop a relative position measurement system that provides precise location information such as construction machinery and robots in a local area where the GPS reception is difficult. A relative position measurement system tracks a marker in the form of a sphere installed on a vehicle by using the image base tracking technology, and measures the distance and direction information to the marker to calculate a position.

LCD 제조공정 종사근로자의 극저주파자기장 노출특성 연구 (A Study on the Extremely Low Frequency Magnetic Fields Exposure Characteristics of Workers in LCD Manufacturing Process)

  • 김준범;강준혁;정은교;정기효
    • 한국산업보건학회지
    • /
    • 제32권1호
    • /
    • pp.10-20
    • /
    • 2022
  • Objectives: The aim of this study is to evaluate exposure levels of the extremely low frequency magnetic fields(ELF-MF) radiated from various electric facilities in Liquid Crystal Display(LCD) manufacturing processes. Methods: This study measured the exposure levels of personal and local ELF-MF for the electronic facilities installed in two LCD manufacturing companies. Samplers were installed around workers' waist during working hours to identify personal exposure levels, and direct reading equipment were located at 3 cm, 10 cm, and 30 cm away from the surface of the electronic facilities to measure local exposure levels. Average and maximum(ceiling) values were calculated for personal and local exposure levels. Results: Average and maximum of personal exposure levels for each worker were 0.56(mean) ± 0.02(SE) µT and 6.31 ± 0.75 µT, respectively. Statistical analyses of the study found that maximum of the personal exposure levels for engineers was significantly higher than that for operators since engineers spend more time near the electronic facilities for repairing. The range of maximum personal exposure levels was 0.50 ~ 43.50 µT and its highest level was equivalent to 4.35 % of ACGIH(American Conference of Governmental Industrial Hygienists) exposure limit value(1 mT). Maximum of local exposure levels was 8.18 ± 0.52 µT and the electronic facilities with higher exposure levels were roof rail and electric panel, which were not related to direct manufacturing. The range of maximum local exposure levels was 0.60 ~ 287.20 µT and its highest level was equivalent to 28.7 % of the ACGIH exposure limit value. Lastly, the local exposure levels significantly decreased as the measurement distance from the electronic facilities increased. Conclusions: Maximum of personal and local exposure levels did not exceed the exposure limit value of ACGIH. However, it is recommended to keep the workers as far as possible from the sources of ELF-MF.

Development of the remote control system for Internet-based mobile robot using Embedded Linux and Qt

  • Park, Tae-Gyu;Jeon, Jae-Wook
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.622-627
    • /
    • 2003
  • The existing remote control system have some inherent disadvantage of direct control in the limit range. In some special cases, for example, a power apparatus, an unmanned factory, a nuclear factory, a security management system, the tele-operation is needed to control remote robot without limit space. This field is based on the Internet communication. Because the Internet is constructed all over the world. And it is possible that we control remote mobile robot in the long distance. In this paper, we developed a remote control system. This system is divided into two primary parts. These are local site and remote site. There are the moving robot and web server in the remote site and there is the robot control device in local site. The moving robot is moved by two stepper motors and the robot control device consists of SA-1100 micro controller and embedded Linux. And this controller is an embedded system. Public personal computer which is connected the Internet is used for the web server. The web server provides the mobile robot control interface program to the remote controller and captures the image for feedback information. In the whole system, a robot control device is connected with moving robot and web server through the Internet. So the operator can control the moving robot in the distance through the Internet.

  • PDF

파랑 및 정상흐름에 의한 해저관로 주변의 국부세굴 특성 비교 (Comparison of Local Scour around Pipeline Caused by Waves and Steady Currents)

  • 김경호;오현식
    • 한국해양공학회지
    • /
    • 제25권2호
    • /
    • pp.21-28
    • /
    • 2011
  • The primary purpose of the present study was to investigate the mechanism causing scour around a pipeline placed on the seabed in a shallow water zone. Such submarine pipelines are usually exposed to currents and waves. The present experiments made estimates for each different flow type. The scour width and depth in the equilibrium scour phase were analyzed by non-dimensional parameters. The experiment in this study considered various parameters: pipe diameters, wave periods, wave heights, and current velocities. Using the experimental results, the correlations of scour width, scour depth, and main non-dimensional parameters such as the Fr number and KC number were analyzed. In the case of steady currents, the scour hole was closely related to the bottom velocity, while the scour hole in waves showed a relatively low correlation to the bottom velocity because when exposed to waves the scour hole was restricted according to the movement distance of the water particles during a wave period. However, the scour width under a steady current was not limited because vortex shedding was well developed from having enough time and distance.

Effect of Air Velocity on Combustion Characteristics in Small-Scale Burner

  • Laryea, Gabriel Nii;No, Soo-Young
    • 한국연소학회지
    • /
    • 제10권1호
    • /
    • pp.1-6
    • /
    • 2005
  • This paper presents the combustion characteristics of hydrocarbon fuel from a conventional pressure-swirl nozzle of a small-scale burner. The nozzle has orifice diameters of 0.256 mm and liquid flow rates ranging from 50 to 64 mL/min were selected for the experiments. The furnace temperature distribution along the axial distance, the gas emission such as CO, $CO_2$, NOx, $SO_2$, flue gas temperature, and combustion efficiency were studied. The local furnace and flue gas temperatures decreased with an increase in air velocity. At injection pressures of 1.1 and 1.3 MPa the maximum furnace temperatures occurred closer to the burner exit, at an axial distance of 242 mm from the diffuser tip. The CO and $CO_2$concentrations decreased with an increase in air velocity, but they increased with an increase in injection pressure. The effect of air velocity on NOx was not clearly seen at low injection pressures, but at injection pressure of 1.3 MPa it decreased with an increase in air velocity. The effect of air velocity on $SO_2$ concentration level is not well understood. The combustion efficiency decreased with an increase in air velocity but it increased with an increase in injection pressure. It is recommended that injection pressure less than 0.9 MPa with air velocity not above 8.0 m/s would be suitable for this burner.

  • PDF

Extraction of a crack opening from a continuous approach using regularized damage models

  • Dufour, Frederic;Pijaudier-Cabot, Gilles;Choinska, Marta;Huerta, Antonio
    • Computers and Concrete
    • /
    • 제5권4호
    • /
    • pp.375-388
    • /
    • 2008
  • Crack opening governs many transfer properties that play a pivotal role in durability analyses. Instead of trying to combine continuum and discrete models in computational analyses, it would be attractive to derive from the continuum approach an estimate of crack opening, without considering the explicit description of a discontinuous displacement field in the computational model. This is the prime objective of this contribution. The derivation is based on the comparison between two continuous variables: the distribution if the effective non local strain that controls damage and an analytical distribution of the effective non local variable that derives from a strong discontinuity analysis. Close to complete failure, these distributions should be very close to each other. Their comparison provides two quantities: the displacement jump across the crack [U] and the distance between the two profiles. This distance is an error indicator defining how close the damage distribution is from that corresponding to a crack surrounded by a fracture process zone. It may subsequently serve in continuous/discrete models in order to define the threshold below which the continuum approach is close enough to the discrete one in order to switch descriptions. The estimation of the crack opening is illustrated on a one-dimensional example and the error between the profiles issued from discontinuous and FE analyses is found to be of a few percents close to complete failure.

연소실 냉각을 위한 충돌제트/유출냉각기법에서 유출판에서의 열전달특성 (Heat Transfer Characteristics on Effusion Plate in Impingement/Effusion Cooling for Combustor)

  • 이동호;조형희
    • 대한기계학회논문집B
    • /
    • 제24권3호
    • /
    • pp.435-442
    • /
    • 2000
  • The present study is conducted to investigate the local heat/mass transfer characteristics for flow through perforated plates. A naphthalene sublimation method is employed to determine the local heat/mass transfer coefficients on the effusion plate. Two parallel perforated plates are arranged for the two different ways: staggered and shifted in one direction. The experiments are conducted for hole pitch-to-diameter ratios of 6.0, for gap distance between the perforated plates of 0.33 to 10 hole diameters, and for Reynolds numbers of 5,000 to 12,000. The result shows that the high transfer region is formed at stagnation region and at the mid-line of the adjacent impinging jets due to secondary vortices and flow acceleration to the effusion hole. For flows through the perforated plates, the mass transfer rates on the surface of the effusion plate are about six to ten times higher than for effusion cooling alone (single perforated plate). More uniform and higher heat/mass transfer characteristic is obtained in overall region with small gap between two perforated plates.

횡분류(流)(橫噴流)에서 난류 비예흔합 화염의 화염날림에 대한 거대 와(渦)구조 혼합 모텔 적용 (A Large-scale Structural Mixing Model applied to Blowout of Turbulent Nonpremixed Jet Flames in a Cross Jet Flow)

  • 이기만;박정
    • 대한기계학회논문집B
    • /
    • 제26권1호
    • /
    • pp.133-140
    • /
    • 2002
  • This article presents an application of a large-scale structural mixing model(Broadwell et at. 1984) to the blowout of turbulent reacting cross flow jets. Experimental observations, therefore, aim to identify the existence of large-scale vortical structure exerting an important effect upon the flame stabilization. In the analysis of common stability curve, it is seen that the phenomenon of blowout are only related to the mixing time scale of the two flows. The most notable observation is that the blowout distance is traced at a fixed positions according to the velocity ratio at all times. Measurements of the lower blowout limits in the liftable flame are qualitatively in agreement with the blowout parameter $\xi$, proposed by Broadwell et al. Good agrement between the results calculated by a modified blowout parameter $\xi$'and the present experimental results confirms the important effect of large-scale structure in the stabilization feature of blowout.

Effect of Air Velocity on Combustion Characteristics Scale Burner

  • Laryea, Gabriel Nii;No, Soo-Young
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2005년도 동계 학술대회 논문집
    • /
    • pp.76-82
    • /
    • 2005
  • This paper presents the combustion characteristics of hydrocarbon fuel from a conventional pressureswirl nozzle of a small-scale burner. The nozzle has orifice diameters of 0.256 mm and liquid flow rates raging from 50 to 64 mL/min were selected for the experiments. The furnace temperature distribution along the axial distance, the gas emission such as CO, $CO_2,\;NOx,\;S0_2,$ flue gas temperature, and combustion efficiency were studied. The local furnace and flue gas temperatures decreased with an increase in air velocity. At injection pressures of 1.1 and 1.3 MPa the maximum furnace temperatures occurred closer to the burner exit, at an axial distance of 242 mm from the diffuser tip. The CO and $CO_2$ concentrations decreased with an increase in air velocity, but they increased with an increase in injection pressure. The effect of air velocity on NOx was not clearly seen at low injection pressures, but at injection pressure of 1.3 MPa it decreased with an increase in air velocity. The effect of air velocity $SO_2$ concentration level is not well understood. The combustion efficiency decreased with an increase in air velocity but it increased with an increase in injection pressure. It is recommended that injection pressure less than 0.9 MPa with air velocity not above 8.0 m/s would be suitable for this burner.

  • PDF