• 제목/요약/키워드: local density

검색결과 1,103건 처리시간 0.027초

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

낙동강 수변 생태복원지 시공 후 4년간(2007~2010년) 식생구조 변화 모니터링 (Monitoring of Plant Community Structure Change for Four Years(2007~2010) after Riparian Ecological Restoration, Nakdonggang(River))

  • 기경석;김종엽
    • 한국환경생태학회지
    • /
    • 제26권5호
    • /
    • pp.707-718
    • /
    • 2012
  • 본 연구는 낙동강수계 매수토지 생태복원지를 대상으로 2007년 복원 공사 직후부터 4년간의 식생구조 변화를 모니터링하고 식생 관리방안을 제시하고자 하였다. 연구대상지는 낙동강 수계 생태복원지 중 총 15개소($208,342m^2$)를 대상지로 하였고 조사는 2007년 11월, 2008년 9월, 2009년 10월, 2010년 9월에 각각 시행하였다. 식재종 및 개체수 변화 분석 결과 교목층은 당단풍나무, 상수리나무, 신나무, 갈참나무, 굴참나무 등은 비교적 개체수가 증가하거나 변화가 없었고 떡갈나무, 말채나무, 뽕나무, 쪽동백나무, 팥배나무는 100% 고사한 것으로 나타났다. 관목은 초본과 덩굴성 식물에 의한 피압으로 대부분 고사하였다. 식재밀도는 4년간 평균 28주/$100m^2$ ${\rightarrow}$ 20주/$100m^2$ ${\rightarrow}$ 16주/$100m^2$ ${\rightarrow}$ 16주/$100m^2$로 감소하였다. 생장량은 복원 공사 직후 이식에 따른 스트레스로 다소 감소하였으나 이후 활착이 이루어짐에 따라 안정화되는 경향을 나타내었다. 흉고단면적 변화는 2007년 복원직후에 $507.1cm^2/100m^2$이던 것이 2008년에 $301.8cm^2/100m^2$로 감소하였으며 이후에는 $324.9cm^2/100m^2$(2009년), $372.7cm^2/100m^2$(2010년)으로 다소 증가하는 경향을 나타내었다. 수변 생태복원지의 식재구조 개선을 위해서는 토양습도를 고려한 수종의 선정과 대상지 여건을 고려한 적정 식재구조의 차별화가 필요하였다.

점봉산 신갈나무군락의 생물종 다양성, 구조 다양성과 지상부 생물량의 관계에 대한 연구 (Relationship between Aboveground Biomass and Measures of Structure and Species Diversity in Quercus mongolica-Dominated Forest, Mt. Jeombong)

  • 정헌모;장인영;홍승범
    • 한국환경생태학회지
    • /
    • 제30권6호
    • /
    • pp.1022-1031
    • /
    • 2016
  • 본 연구는 강원도 점봉산에 분포하고 있는 신갈나무군락에서 군락의 지상부 생물량과 생물종 다양성, 그리고 군락 구조의 다양성 간의 관계 특성을 밝히기 위하여 수행되었다. 이를 위해, 2004년부터 2013년까지 점봉산 신갈나무군락에서 측정한 지상부 생물량은 총 $311.1ton{\cdot}ha^{-1}$였으며, 종 별 생물량 및 구성 비율은 신갈나무 $206.3ton{\cdot}ha^{-1}$(66.3%),까치박달 $36.9ton{\cdot}ha^{-1}$(11.9%),피나무 $30.6ton{\cdot}ha^{-1}$(9.8%)등의 순으로 적었다. 신갈나무의 지상부 생물량이 가장 많은 것은 전체에 비해 임목 밀도가 많지 않지만, 평균 흉고직경(DBH)이 50cm 이상인 개체수 비율이 다른 수종에서 보다 월등히 높기 때문인 것으로 판단된다. 이 군락의 종 다양성 지수(H')와 종 균등도(J')를 추정해 본 결과 각각 2.015~2.166과 0.673~0.736의 범위 내에서 시간에 따른 점진적인 증가를 보여 주고 있다. 위의 종 다양성 지수와 종 균등도는 지상부 생물량과 높은 양의 상관관계를 나타내는데, 이는 시간이 변함에 따라 신갈나무군락의 지상부 생물량이 공간적으로 균일해진다는 것과 이러한 현상이 다양한 수종에 걸쳐 나타나고 있다는 것을 의미한다. 또한, 생물량-종 다양성 지수(BS)와 종 풍부도-생물량-종 다양성 지수(ABS)도 각각 3.746~3.811, 4.781~5.028 범위 내에서 시간에 따른 점진적인 증가를 보여주고 있었으며, 이들 지수와 지상부 생물량 높은 양의 상관관계가 관찰되었다. 이는 신갈나무군락의 지상부 생물량이 다양한 수종에서 뿐만 아니라 다양한 직경급에 따라 균일해 지고 있음을 나타낸다. 그리고 점봉산 신갈나무군락은 군락의 구조적 다양성을 통하여 생산성과 탄소 저장 능력이 더욱 효율화 되어, 자원이 풍부한 생태계로서의 역할을 수행 할 것으로 예상된다. 또한 복원된 산림의 생물다양성과 생산성의 유지를 위하여 생태적 특성을 고려한 다양한 수종과 다양한 DBH 수목의 선택적 식재를 제안한다.

삼상유동층에서 동력학적 기체유출 측정방법에 의한 큰 기포와 작은 기포의 체류량 특성 해석 (Analysis of Holdup Characteristics of Large and Small Bubbles in Three-Phase Fluidized Beds by using a Dynamic Gas Disengagement Method)

  • 임현오;임대호;서명재;강용;정헌;이호태
    • Korean Chemical Engineering Research
    • /
    • 제49권5호
    • /
    • pp.605-610
    • /
    • 2011
  • 내경이 0.105 m이고 높이가 2.5 m인 삼상(기체-액체-고체) 유동층에서 상대적으로 큰 기포와 작은 기포의 체류량 특성을 고찰하였다. 기체유속(0.01~0.07 m/s), 액체유속(0.01~0.07 m/s) 그리고 입자크기($0.5{\sim}3.0{\times}10^{-3}m$)가 상대적으로 큰 기포와 작은 기포의 체류량에 미치는 영향을 검토하였다. 삼상 유동층에서 이들 두 종류 기포들의 체류량은 동력학적 기체 유출 방법(Dynamic gas disengagement method)에 의해 측정된 각각 기포들에 의한 압력강하 정보로부터 정압강하법(static pressure drop method)에 의해 산출되었다. 기체조절기에 의해 조절되는 건조되고 여과된 공기와 물 그리고 밀도가 2,500 $kg/m^3$인 유리구슬을 각각 기체, 액체 및 고체유동입자로 사용하였다. 삼상유동층에서 이들 두 종류의 기포, 즉 상대적으로 큰 기포와 작은 기포들은 유동층 탑에 유입되는 기체와 액체의 흐름을 정지시킨 후 경과시간에 따른 탑 내부의 압력강하를 측정함으로써 효과적으로 조사하고 분리할 수 있었다. 이들 두 종류의 기포들은 경과시간에 따라 증가하는 압력강하의 기울기가 서로 매우 다르게 나타났다. 실험결과 상대적으로 큰 기포들의 체류량은 기체의 유속이 증가함에 따라 증가하였으나 액체의 유속이 증가함에 따라서는 감소하였다. 그러나, 이들 큰 기포의 체류량은 유동입자의 크기가 변화함에 따라 국부적인 최소값을 나타내었다. 상대적으로 작은 기포들의 체류량은 기체유속 또는 고체입자의 크기가 증가함에 따라 증가하였으나 액체의 유속이 증가함에 따라서는 약간 감소하였다. 이들 두 종류 기포들의 체류량들은 각각 본 연구의 실험 범위 내에서 조작변수들의 상관식으로 나타낼 수 있었다.

게임서버의 CPU 사용율 기반 효율적인 부하균등화 기술의 설계 및 구현 (Design and Implementation of Game Server using the Efficient Load Balancing Technology based on CPU Utilization)

  • 명원식;한준탁
    • 한국게임학회 논문지
    • /
    • 제4권4호
    • /
    • pp.11-18
    • /
    • 2004
  • 과거의 온라인 게임은 일대일 접속으로 두 사람만이 데이터를 주고받으며 게임 할 수 있었으나 현재의 온라인 게임은 MMORPG라고 해서 수만 명의 사람들이 동시에 접속이 가능하다. 특히 우리나라는 세계 어느 나라에서 찾아 볼 수 없는 네트워크 인프라를 확보하고 있다. 거의 모든 가정에 초고속 인터넷 통신망이 설치되어 있으며 높은 인구 밀도는 이런 인프라의 형성을 가속화하는 것을 가능하게 했다. 하지만 이러한 온라인 게임의 급격한 증가는 제한적인 인터넷의 통신용량에 대하여 트래픽의 증가로 이어지고 온라인 게임이 접속이 불안정해지거나 접속이 다운되는 상태로 이어질 가능성이 높다. 이러한 문제를 해결하기 위해 각 게임 서버를 보다 확충함으로서 해결할 수 있으나 그럴 경우 고비용을 필요로 하게 된다. 본 논문에서는 이러한 문제점을 해결하고자 현재의 온라인 게임에서 사용되고 있는 컨텐츠별로 나누어진 게임 서버들을 지 역 클러스터 링 형태로 연결하고, 부하 균등화(Load Balancer)서버로써 특정한 게임 서버의 부하를 감소시키고 게임 서버의 성능 향상과 효율적인 게임 서버 운용을 위하여 부하 균등화 기법을 제안한다. 본 논문에서는 그룹별 각각 다른 서비스를 하고 CPU 사용율의 자원정보를 이용하여 효율적으로 부하를 균등화하는 기법을 제안한다. 각각 서로 다른 게임을 서비스하는 그룹들은 컨텐츠들에 대한 수정, 삭제, 추가 등 자원 정보 변경으로 인하여 깨어질 수도 있는 자원 정보 일관성을 유지하기 위해 네트워크 파일 시스템에 연결되어 운영된다. 성능 실험을 통해 기존의 RR방식과 LC방식보다 제안한 방식이 각각 12%와 10%의 응답시간 향상을 보여주었다.기간효과를 별도로 취급하기는 쉽지 않다.이즈의 영향이 가장 클 것으로 판단된다. 항원성시험에서 casein으로 피하 감작할 경우 푸른색 반점이 나타났으나 효소처리구에서는 이러한 반점이 나타나지 않아 충분히 항원성이 저감화 되었음을 확인하였다. 행동을 평가하는데 있어 적정한 신뢰도와 타당도를 가지고 있었으며 임상 장면에서 아동의 행동 문제에 대한 평가 및 진단에 유용하게 사용될 수 있을 것으로 보인다.식적인 형태소-음소 상응 규칙 적용 능력 모두에서 장애를 보였으며, 거울상 반전 오류 등 시각적 정보 처리 기능의 장애도 나타내었다. 이들 장애는 단어/비단어 읽기 검사와 글자기호감별검사를 통해 신뢰할 수 있고 타당성 있게 구분하고 평가할 수 있었다.치료 시 고려해야 할 것이다.순차처리항목과 계산능력에서 유의하게 높았고(p<.05), KEDI-WISC를 이용한 평가에서는 ADHD- HI형은 대상수가 소수여서 비교할 수 없었으며, ADHD-C형과 ADHD-Ⅰ형 사이에 유의한 차이는 보이지 않았다. CPT, WCST, SST를 이용한 신경심리학적 실행기능의 비교에서 아형간 계량적인 차이는 있었으나 통계적으로 유의한 차이는 보이지 않았다. 결 론:결론적으로 ADHD 세 아형은 임상적으로 뚜렷한 차이를 보였지만, 실행기능상 유의한 차이를 발견할 수 없었다. 향후 보다 잘 고안 된 연구와 발달중인 아동에 적절한 신경심리 평가 도구의 개발을 통해 결과를 보완해야 할 것으로 사료된다.었으나, 주의력에서는 전두엽의 실행능력(executive function)과 관련되는 검사들에서 산소흡입이 특이한 효과를 보여준다는 것이 확인되었고, 기억능력에서는 단기기억능력 평가에서 산소흡입군이

  • PDF

조선시대(朝鮮時代) 도작농업(稻作農業)의 발전(發展)과 인구증가(人口增加) (Rice Cultivation and Demographi Development in Korea : 1429-1918)

  • 이호철
    • Current Research on Agriculture and Life Sciences
    • /
    • 제7권
    • /
    • pp.201-219
    • /
    • 1989
  • Rice culture in Korea has a long history ranging over two thousand years. In the agriculture economy of pre-mordern Korea, however, its importantce was not as great as generally assumed. In fact, rice culture reached full development only after the 1920s when the Japanese colonial government carried out its drive to increase rice production in the Korea peninsula. It was not until the mid-1930s that rice became the staple in Korean diet. This can be attributed to two factors : (1) a mountainous topography that provides little irrigated fields and (2) a climate characterized by droughts in spring and heavy precipitation in summer. The present paper attempts to answer some of these questions. Specifically it will focus on these : Did the development of rice culture actually result in population growth? What are the salient features of agricultural develdpment and population grow in traditional Korea? Does the case of Korea conform the prevailing generalization about the agriculture in East Asia? I have discussed the development of rice culture and population growth in the Chos$\breve{o}$n dynasty, focusing on the relation between the rapid spread of transplanting and the rapid growth of population from the seventeenth to the nineteenth century. Here are my conclusions. (1) The spread of transplanting and other technological innovationsc contributed to the rapid growth of population in this period. However, we should also note that the impact of rice culture on population growth was rather limited, for rice culture was not the mainstay of agricultural economy in pre-modern Korea. Indeed we should consider the influence of dry field cropsn population growth. Nevertheless, it is obvious that the proliferation of rice culture was a factor crucial to population growth and regional concentration. (2) How should we characterize the spread of rice culture in the whole period? Evidently rice culture spread from less then 20% of cultivated fields in the fifteenth century to about 36% of them in the early twentieth century. Although rice as a single crop outweighed other crops, rice culture was more then counter-balanced by dry field crops as a whole, due to Korea's unique climate and geography. Thus what we have here in not a typical case of competition between rice culture and day field culture. Besides, the spread of rice culture in the seventeenth and eighteenth centuries accomplished by technological innovations that overcame severe springtime drought, rather than extensive irrigation. Althougt irrigarion facilities did proliferate to some extent, this was achieved by local landlords and peasants rather than the state. This fact contradicts the classical thesis that the productivity of rice culture increased through the state management of irrigation and that this in turn determined the type of society. (3) We should further study other aspects of the transition from the stable population and production struture in the fifteenth and sixteenth centuries to the rapid population growth and excessive density of population thereafter. We should note that there were continuing efforts to reclaim the land in order to solve the severe shortage of land. Changes also took place in the agricultural production relations. The increase in land producrivity developed tenancy based on rent in kind, and this in turn increased the independence of tenants from their landlords. There were changes in family relations-such as the shift to primogeniture as an effort to prevent progressive division of property among multiplying offspring. The rapid population growth also produced a great mass of propertyless farm laborers. These changes had much to do with the disintegration of traditional social institutions and political structure toward the end of the Chos$\breve{o}$n dynasty.

  • PDF

우간다 초등학생의 영양섭취 실태조사: 도심지역과 농촌지역의 비교 (Evaluation of Nutritional Status among Primary School Children in Uganda: Comparison of Urban and Rural Areas)

  • 이지연;박혜정;유민;황하영;성정림;김희선
    • 대한지역사회영양학회지
    • /
    • 제25권2호
    • /
    • pp.91-101
    • /
    • 2020
  • 연구에 참여한 우간다 초등학교 2곳 학생들이 평소 식사섭취패턴을 유지한다면 향후 학생들의 영양불량이 염려되므로 빠른 시일 내 효과적인 영양중재프로그램이 실시될 필요가 있다. 우간다 자국민의 미량영양소 섭취결핍 문제는 본 연구 대상들에게서도 심각성이 확인되어 성장기에 바람직한 건강과 영양 상태를 유지하기 위해 비타민과 무기질 섭취 및 식사다양성을 향상시킬 수 있는 영양 강화 급식이 제공될 필요가 있다. 지역별 대상자들의 식사섭취패턴의 차이는 시장 접근성, 우간다 기후에 따른 재배가능 농작물과 자급률 등 환경적 요소와 사회경제학적 요인으로 인해 뚜렷한 차이를 보였으므로 본 사업 전 예비조사를 통해 마을공동체의 토속적 식생활패턴과 영양상태 문제점 등을 파악하는 것이 효과적인 중재계획을 설정하는데 도움이 되리라 사료된다. 이와 함께 지역별 인프라 및 식품 유통망의 특징 및 지역농작물의 자급수준도 면밀히 조사가 시행되어야 할 것으로 사료된다. 마지막으로 국제개발원조사업의 지속가능성을 고려하여 급식중재 메뉴에 다양한 현지 식품과 지역농작물을 적극적으로 활용하는 등 '선 순환적 네트워크'를 구축하도록 다양한 방법을 적용해야할 것으로 사료된다. 이를 통해 여전히 국제원 조사업의 수혜자적 측면에서 소외계층이라 사료되는 초등학교 학생들에게 효과적인 급식개선 중재사업은 인도주의적 차원의 서비스로도 적용되어 학생의 출석률 및 진학률을 높이고 중퇴율과 퇴학률 개선에 긍정적인 효과를 주어 우간다 초등교육 여건 향상에 기여하리라 사료된다.

3차원 속도 토모그래피를 이용한 북한지역의 지각구조 연구 (Study of Crustal Structure in North Korea Using 3D Velocity Tomography)

  • So Gu Kim;Jong Woo Shin
    • 지질공학
    • /
    • 제13권3호
    • /
    • pp.293-308
    • /
    • 2003
  • 북한 지역 60km 하부 지각구조에 관한 새로운 결과를 토모그래피 방법으로 연구하였다. 한반도와 주변에서 얻어진 1013개의 P파와 S파 주행시간이 사용된다. 또한, 이 연구에서 토모그래피 알고리즘에 의해서 모든 지진의 진원이 재결정 된다. 속도구조의 파라미터화는 지진파 밀도에 따라 분포된 Node에 의해서 결정된다. 4개 Level의 120 Node가 각각 P파와 S파의 속도 구조에 적용된다. 연구 결과로 깊이 8Km의 량림 육괴의 깊이에서 P파와 S파 속도 이상변화는 각각 높고 낮게 나타났다. 그 반면에 평남분지의 P파와 S파 속도는 24km 깊이까지 모두 낮게 나타났다 그것은 량림 육괴는 지하수나 온천 등으로 포화 된 단층 및 파쇄대를 많이 갖고 있는 시생대-초기 하부 원생대육괴로 되어 있고, 반면에 평남분지의 평양-사리원 일대는 상부 원생대, 실루리안, 상부 고생대와 하부 중생대 기원의 퇴적층으로 채워진 내부 플렛트 폼 함몰로 되어 있음을 의미한다. 특히 백두산 하부 8, 16. 24km 깊이에서 높은 P파와 5파의 속도이상은 고결된 마그마 물체의 천부 도랑일지 모른다. 그러나 38km에서 낮은 P파와 S파 속도이상은 용융상태의 저속도 마그마방과 관련 된 것으로 본다. 우리는 또한 사리원을 포함한 옹진 분지에서 Moho불연속면이 약 55km임을 발견하였다. 백두산의 모호불연속면은 38km가량 된다. 특히 백두산 Moho에서 V/sub p//V/sub s/의 높은 비율은 지각과 맨틀 경계에서 용융물체가 있는것으로 간주된다. 또한 본 연구는 또한 량림육괴 순상지(Shield)의 끝 가장자리인 묘향산 지역 하부 40km에서 매운 높은 P파와 S파 속도 구조를 갖는 물체가 있음을 보여 주었다.

생명기후분석시스템(BioCAS)을 이용한 폭염 건강위험의 검증 - 서울시 건물규모를 중심으로 - (Evaluation of Health Impact of Heat Waves using Bio-Climatic impact Assessment System (BioCAS) at Building scale over the Seoul City Area)

  • 김규랑;이지선;이채연;김백조;브리타 얘니케;아힘 홀트만;디터 쉐러
    • 환경영향평가
    • /
    • 제25권6호
    • /
    • pp.514-524
    • /
    • 2016
  • 생명기후분석시스템(BioCAS)을 이용하여 서울시 전역의 폭염사례일 기온, 인지온도(PT), 초과사망률($r_{EM}$) 분포를 분석하였다. 분석 해상도는 25m 였으며, 사례일은 2012년 8월 5일이었다. 분석 결과는 관측된 사망률 및 내원환자수 자료와의 비교를 통해 평가되었다. 2004년에서 2013년의 폭염 원인인 사망률 자료와 2006년에서 2011년의 국민건강보험공단의 폭염 내원환자수 자료를 이용하여 행정구별 폭염 건강위험 자료를 추출하였다. 자료 비교를 위한 공간 해상도는 사망률 및 내원환자수 자료의 해상도인 행정구 단위였다. BioCAS에서 분석된 사례일 최고 인지온도 및 초과사망률 분포 자료는 행정구별 공간 평균, 최대, 최소 및 누적값으로 변환된 후 건강피해자료와 상관분석이 수행되었다. 분석 결과 일 최고 인지온도 및 초과사망률의 공간 평균값은 건강피해를 설명하지 못하는 것으로 나타났다. 대신 일 최고 인지온도의 공간 최솟값은 사망률과, 공간 최댓값은 내원환자수와 상관관계가 있는 것으로 나타났다(각각 r=0.53, r=0.42). 즉, 밀집된 건물에 의해 생겨나는 공간 최댓값은 낮 동안의 일사병 발생과 내원환자수 증가에 영향을 주었고, 식생에 의해 나타나는 공간 최솟값은 밤 동안의 열 스트레스를 감소시켜 사망률에 영향을 주었던 것으로 판단된다. 한편 분석된 초과사망률($r_{EM}$)은 공간 최댓값과 내원환자수가 상관관계가 있었지만(r=0.52) 사망률과의 상관관계는 인정되지 않았는데, 이것은 연령별 인구구성 차이에 따른 기저 폭염위험도 차이 등 행정구별 불균일성을 고려하지 못한 한계가 나타난 것으로 판단된다. 개별 건물과 식생의 열적 효과는 공간 평균보다 최대, 최소 등 그 분포가 중요한 것으로 나타났다. 이러한 고해상도 분석기술은 도시의 건강영향평가를 통해 도시개발에 관한 경제성 분석에 활용이 가능할 것으로 기대된다.