• 제목/요약/키워드: local cooling temperature

검색결과 182건 처리시간 0.025초

A Numerical Study on Cavitation Suppression Using Local Cooling

  • Zhang, Yuan-Yuan;Sun, Xiao-Jing;Huang, Dian-Gui
    • International Journal of Fluid Machinery and Systems
    • /
    • 제3권4호
    • /
    • pp.292-300
    • /
    • 2010
  • This study strives to develop an effective strategy to inhibit cavitation inception on hydrofoils by using local cooling technique. By setting up a temperature boundary condition and cooling a small area on the upper surface of a hydrofoil, the fluid temperature around the cooling surface will be decreased and thereby the corresponding liquid saturation pressure will drop below the lowest absolute pressure within the flow field. Hence, cavitation can never occur. In this paper, a NACA0015 hydrofoil at $4^{\circ}$ angle of attack was numerically investigated to verify the effectiveness of the proposed technique. The CFD results indicate that the cooling temperature and the cooling surface roughness are the critical factors affecting the success of such technique used for cavitation suppression.

Al-7wt%Si-0.3wt%Mg 합금의 응고 및 미세조직에 미치는 Sr 첨가와 금형예열온도의 영향 (The Effect of Sr Addition and Mold Preheating Temperature on the Solidification and Microstructure of Al-7wt%Si-0.3wt%Mg Alloy)

  • 권일수;김경민;윤의박
    • 한국주조공학회지
    • /
    • 제17권6호
    • /
    • pp.608-614
    • /
    • 1997
  • The effect of mold preheating temperature on the microstructure such as grain size, eutectic silicon morphology was investigated for the Al-7wt%Si-0.3wt%Mg alloy. Microstructural variations have been characterized as a function of Sr addition and cooling rate during solidification. Microstructures were correlated with cooling rate, local solidification time and eutectic nucleation temperature, etc. In this study, Sr addition caused increase of local solidification time, undercooling and reduction of eutectic plateau temperature. In logarithmic scale, local solidification time was in inverse proportion to cooling rate. Eutectic nucleation temperature was in inverse proportion to cooling rate of logarithmic scale. Increasing the cooling rate refined dendrite arm spacing and eutectic silicon. Dendrite arm spacing was logarithmically in inverse proportion to cooling rate. Without modifier addition, eutectic silicon was modified at cooling rate of $7^{\circ}C/s$ or higher.

  • PDF

근권부 국부 냉방이 토마토 묘 생육에 미치는 영향 (Effect of Root-zone Local Cooling on Seedling Growth of Tomato)

  • 김은지;황현승;주세훈;나해영
    • 생물환경조절학회지
    • /
    • 제31권4호
    • /
    • pp.286-291
    • /
    • 2022
  • 본 연구는 근권부 냉방이 토마토 육묘 시 묘 생육에 미치는 영향을 구명하고자 수행되었다. 생장상 하부 파이프 냉방을 이용하여 근권부 온도를 20℃와 25℃로 설정하여 실험을 수행하였다. 전 생육기간동안 초장, 근장, 엽수는 두 온도 처리구간 차이를 보이지 않았다. 엽면적, 지상부와 지하부의 생체중 및 건물중, 엽록소 함량은 파종 28일 경과 시 25℃ 처리구가 더 높았으며, 실험 종료 시 두 처리구 간 유의한 차이를 보이지 않았다. 이상의 결과로 근권부 온도 20℃와 25℃에서 토마토 생육 차이를 확인하지 못했다. 따라서, 본 연구는 고온기 토마토 묘 생산 시 온실 냉방 효율을 높이기 위한 국부 냉방 기술 확립에 도움을 줄 수 있을 것이다.

고온환경 하에서 착용하는 인체냉각 보조도구로서의 Cooling Vest 연구(1) -Local Cooling에 따른 인체의 온열생리학적 특성- (Efficacy of Cooling Vest for Auxiliary Body Cooling in Hot Environments (1) -Thermophysiological Response of Human Body in Local Cooling-)

  • 권오경;김진아;김태규
    • 한국의류산업학회지
    • /
    • 제2권3호
    • /
    • pp.265-271
    • /
    • 2000
  • Heat stress results in fatigue, a decline in strength, alertness., and mental capacity. The problem is compounded when high humidity exists. To help relieve worker heat stress, many types of cooling units are marketed. While workers may experience some cooling, critical body core temperatures often continue to elevate. This study was designed to find the effects of three kinds of cooling vest with portable frozen gel strips on thermophysiological parameters and on temperature and humidity within clothing. The heart rate, rectal, and skin temperature as well as sweat rate and clothing microclimate were measured during 80 min in 5 healthy males. Inquiries were also made into the subjective rating thermal, humidity comfort, and fatigue sensations. The main findings in our experiments are as follows: (a) Physiological parameters such as rectal temperature was the lowest in garb A1, intermediate in garb A, and the highest in garb A2 throughout the experiment. And mean skin temperature was the lowest in garb A, intermediate in garb A1, and the highest in garb A2; (b) Temperature and humidity within clothing (back) were garb in Al, intermediate in garb A, and the highest in garb A2. But the temperature and humidity within clothing (chest) were garb in A, intermediate in garb A1, and the highest in garb A2; (c) Most participants (4 out of 5 persons) answered that they felt more comfortable and fatigueless in garb A1 than in garb A and A2. It is concluded that local cooling in garb A1 of the upper torso could physiological reduce the thermal strain in participants wearing cooling vest.

  • PDF

냉각수 온도에 따른 수분류 충돌제트의 열전달 특성 연구 (Effect of Cooling Water Temperature on Heat Transfer Characteristics of Water Impinging Jet)

  • 이정호;유청환;도규형
    • 열처리공학회지
    • /
    • 제23권5호
    • /
    • pp.249-256
    • /
    • 2010
  • Water jet impingement cooling has been widely used in a various engineering applications; especially in cooling of hot steel plate of steelmaking processes and heat treatment in hot metals as an effective method of removing high heat flux. The effects of cooling water temperature on water jet impingement cooling are primarily investigated for hot steel plate cooling applications in this study. The local heat flux measurements are introduced by a novel experimental technique that has a function of high-temperature heat flux gauge in which test block assemblies are used to measure the heat flux distribution during water jet impingement cooling. The experiments are performed at fixed flow rate and fixed nozzle-to-target spacing. The results show that effects of cooling water temperature on the characteristics of jet impingement heat transfer are presented for five different water temperatures ranged from 5 to $45^{\circ}C$. The local heat flux curves and heat transfer coefficients are also provided with respect to different boiling regimes.

신체 부위별 냉각허용한계온도에 관한 연구 (Permissible Safety Limits in Local Cooling Focused on the Parts of Human Body)

  • 황경숙;최정화;김경란
    • 한국의류학회지
    • /
    • 제31권1호
    • /
    • pp.119-130
    • /
    • 2007
  • The objects of this study were to investigate responses and peculiarity during local cooling by parts of the human body and to show permissible safety limits without injurious to his health because of excessive cooling when he works hot environments. It were measured rectal temperature, skin temperature, heart rate, total body weight loss, local sweat in back and thigh, clothing microclimate and subjective sensation on 8 subjects and cooling parts were head, neck, chest, abdomen, back, waist, hip, upper arm, forearm, hand, thigh, calf and foot. According to above-mentioned the first experiment, we chose permissible safety limits by parts of the human body for one hour. In the second experiment, it was showed permissible safety limits by parts which examined their safety about health through 4 hours cooling test on 3 subjects. The results are as follows: 1. As a result of the first experiment, we chose permissible safety limits by parts, as follows, head $25^{\circ}C$, neck $20^{\circ}C$, chest $27^{\circ}C$, abdomen $25^{\circ}C$, back $20^{\circ}C$, waist $20^{\circ}C$, upper arm $20^{\circ}C$, forearm $20^{\circ}C$, hand $23^{\circ}C$, thigh $20^{\circ}C$, calf $20^{\circ}C$ and foot $23^{\circ}C$ in $37^{\circ}C$, 50%R.H. environment for 1 hour. 2. As a result of the second experiment, cooling on these safety limits temperatures except chest didn't have a bad effect on health. So it was proved that right permissible safety limits of chest was $28^{\circ}C$. From these results, it has been suggested that skin temperature didn't fall below permissible safety limits when human body was to be cool by parts.

분무냉각에 의한 강판 열처리과정에 있어서 열전달분포의 측정 (Measurements of Heat Transfer Distribution in Spray Cooling of Hot Steel Plate .)

  • 김영찬;유갑종;서태원
    • 설비공학논문집
    • /
    • 제12권10호
    • /
    • pp.886-893
    • /
    • 2000
  • A good understanding of the heat transfer distribution is very important to suppress the deformation of steel products. In this study, the local heat transfer coefficients are experimentally investigated to understand the heat transfer distribution of thick steel plates with even flat spray nozzle. The steel slabs are cooled down from the initial temperature of about $1000^{\circ}C$ , and the local heat transfer coefficients and surface temperatures are calculated from the measured temperature-time history. The results show that the local heat transfer coefficients of spray cooling are dominated by the local droplet flow rate, and in proportion to becoming more distant from the center of heat transfer surface, the local heat transfer coefficients decrease with the decrease of the local droplet flow rate.

  • PDF

압전소자와 열전소자를 이용한 국소부 냉각성능 평가에 관한 연구 (Study on Evaluation of Local Cooling Performance using Piezoelectric and Thermoelectric Modules)

  • 오후석;최병희
    • 한국산학기술학회논문지
    • /
    • 제18권2호
    • /
    • pp.478-483
    • /
    • 2017
  • 본 논문에서는 소형 전자기기와 같은 발열부 온도 제어를 위해 압전 소자와 열전 소자를 이용하여 국소부 냉각 성능을 실험적으로 조사해 보았다. 실험은 열전 소자를 이용하여 실험 영역내에 냉각부를 형성하고, 압전 소자에 80Hz와 110Hz 의 인가주파수를 각각 적용하여, 압전 소자를 작동시켰을 때와 작동시키지 않았을 때 열전 소자에 의해 형성된 시험부의 냉각 영역에서 온도 분포를 측정하였다. 또한, 냉각 영역의 온도측정 결과를 토대로 압전 소자를 적용하였을 때와 적용하지 않았을 때 냉각 영역의 성능 계수를 계산하고, 가시화 장치를 구성한 후 시험부내에 냉각 영역의 열유동 현상도 확인해 보았다. 실험결과, 온도분포 측정 실험 결과와 성능 계수 계산 결과로 부터 압전 소자를 작동하지 않은 경우보다 압전 소자를 작동한 경우에서 냉각 성능이 개선되는 것을 확인할 수 있었다.. 또한, 가시화 결과를 토대로 열전 소자에 의해 형성된 냉각 영역에 압전 소자를 작동시켰을 경우에 냉각 영역의 국소부에 압전 소자에 의한 상하 진동의 강제 대류 현상이 발생하면서 냉각영역 전체에 고르게 분포하는 유동을 형성하고 냉각 성능이 개선되는 원인을 확인할 수 있었다.

핫팩을 이용한 인체의 부위별 가온과 제거가 사지부 피부 열화상도에 미치는 영향 (Effects of local body heating and cooling on thermogram analysis of the extremity with hot pack)

  • 김소영;홍경희
    • 한국생활과학회지
    • /
    • 제23권6호
    • /
    • pp.1205-1215
    • /
    • 2014
  • The purpose of this study was to investigate the effect of local heating and cooling of various body parts on the skin temperature of the exposed extremities including neck. Hot pack was used to warm up the body of seven participants for 15 minutes and it was removed as the temperature of the hot pack decreased after 15minutes of warming. Thermograms of body surface with and without hot pack were analyzed intensively to observe the efficiency of the local heating of shoulder, abdomen, back waist, and foot on the skin temperature of ten area of the subjects' body. The results indicated that the absolute skin temperature of front upper arm and thigh was significantly higher depending on the area of heating, especially, in case of abdomen and foot heating, which was not observed at the back of the body. The rate of skin temperature of extremities such as finger, palm and foot was significantly different depending on the body area of local heating. Generally, it was found that back waist heating was not efficient to warm up and maintain the skin temperature of the body after removing the hot pack.

냉각공기량이 자동차 냉각성능에 미치는 영향에 관한 실험적 연구 (An Experimental Study on Effects of Cooling Airflow rate on the Automotive Cooling Performance)

  • 김진현;이해철;박종남;차경옥
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.950-954
    • /
    • 2001
  • Gasoline engine manufacturers are currently considering designs that will result in low combustion air temperature for improvement of fuel consumption and emission levels. There are a variety of cooling systems that can be used to accomplish this goal. Coolong is therefore normally achieved through a balance of ram and fan action. This paper studies the various systems and compare the cooling performance for several conditions, based on a automotive engine. An experimental analysis was developed to predict the interaction of the fan system and the heat exchangers of the engine cooling system. The local temperature induced by the fan on the cooling system is measured. These experimental result were accomplished using air flow management techniques.

  • PDF