• 제목/요약/키워드: local air temperature

검색결과 418건 처리시간 0.028초

GIS 기법을 이용한 대기온도 변화 분포 분석 (Analysis of Air Temperature Change Distribution that Using GIS technique)

  • 정규용;강인준;김수겸;주홍식
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2010년 춘계학술발표회 논문집
    • /
    • pp.395-397
    • /
    • 2010
  • AWS that exist in Pusan is watching local meteorological phenomena established in place that the weather observatory does not exist by real time, and is used usefully to early input data of numerical weather forecasting model. I wished to display downtown of Pusan and air temperature change of peripheral area using this AWS data. Analyzed volatility using AWS observation data for 5 years to recognize air temperature change of Pusan area through data about temperature among them. Drew air temperature distribution chart by season of recapitulative Pusan area applying IDW linear interpolation with this.

  • PDF

대류난방시 실내열환경에 관한 연구 - 온도 및 기류속도에 대한 온열쾌적감- (The Study on Indoor Thermal Environment during Convection Heating - Thermal Comfort by Indoor Air Temperature and Velocity -)

  • 김동규;정용현
    • 한국환경과학회지
    • /
    • 제14권2호
    • /
    • pp.209-214
    • /
    • 2005
  • Draft is defined as an unwanted local cooling of the human body caused by air movement. It is a serious problem in many ventilated or air conditioned buildings. Often draft complaints occur although measured velocities in the occupied zone maybe lower than prescribed in existing standards. Purpose of this study is to clarify the evaluation of thermal comfort based on temperature and air velocity in winter. Experiments were performed in an environmental chamber in winter. Indoor temperature and air velocity was artificially controlled. The experiments were performed to evaluate temperature conditions and air velocity conditions by physiological and psychological responses of human. According to physiological responses and psychological responses, it was clear that the optimum air velocity is about 0.15 m/s and 0.30 m/s.

바닥취출 공조공간에서 급기온도 및 급기풍속이 환기효율에 미치는 영향 (Effect of supply air temperature and airflow rate on ventilation effectiveness in an underfloor air conditioning space)

  • 정광섭;한화택;홍승재
    • 설비공학논문집
    • /
    • 제10권5호
    • /
    • pp.640-648
    • /
    • 1998
  • A numerical study has been conducted to investigate the effect of inflow supply air temperature and velocity on ventilation effectiveness in an underfloor air conditioning space. A low Reynolds number k-$\varepsilon$ model is implemented to calculate steady state turbulent velocity distributions. A step-down injection method is used to calculate local and room mean ages from transient concentrations based on the concept of the age of air. Results show that there is a significant effect of Archimedes number on ventilation effectiveness especially for cooling conditions. Reynolds number shows relatively minor effect on velocity distribution and ventilation effectiveness especially for isothermal and heating conditions. It can be concluded that underfloor air conditioning system provides good ventilation characteristics for cooling conditions because of temperature stratification in the space.

  • PDF

대향류 확산화염의 고온공기 연소특성에 관한 수치해석 (A Numerical Analysis of the Characteristics with High Temperature Air Combustion in Counterflow Diffusion Flame)

  • 조은성;히데아키 코바야시;정석호
    • 한국연소학회지
    • /
    • 제8권4호
    • /
    • pp.9-14
    • /
    • 2003
  • High temperature air combustion technology has been utilized by using preheated air over 1100 K and excessive exhaust gas recirculation. Numerical analysis was performed to investigate the combustion characteristics with high temperature deficient oxygen air combustion by adopting a counterflow as a model problem accounting for detailed chemical kinetics. Methane($CH_4$) was used as a test fuel and calculated oxidizer conditions were low temperature high oxygen (300K, $X_{O2}=0.21$) and high temperature low oxygen (1300K, $X_{O2}=0.04$) conditions. The latter case showed that the flame temperature is lower than the former case and its profile showed monotonic decrease from oxidizer to fuel side, without having local maximum flame temperature at high stretch rate. Also, heat release rate was one order lower and it has one peak profile because of low oxygen concentration and heat release rate integral is almost same for stretch rate. High temperature low oxygen air combustion shows low NO emission characteristics.

  • PDF

열풍기 이용 콘크리트 보온양생 성능 개선 방안 분석 (A Study on the Improvement of Thermal Curing Performance of Concrete Using Hot Air Blower)

  • 최지수;김상엽;송진희;조홍범;이규남
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.239-240
    • /
    • 2022
  • In winter, low outdoor temperature can casue reduction of concrete strength. Therefore, thermal protection is required when curing concrete in winter to maintain a certain level or higher surface temperature. Accordingly, in domestic construction sites, a curing method in which surrounds casting areas by tents and operates hot air blowers are widely applied. However, local low-temperature areas may occur due to airtightness of the curing tents. If additional heat is supplied to prevent occurrence of local low-temperature areas, energy consumption increases. Therefore in this study, a plan for improvement method of concrete curing was considered and the performance was evaluated through numerical analysis. A plan to improve the airtightness of the wall opening was applied, but the analysis showed that if only a part of the curing area is shielded, the temperature of the unshielded area decreases,making it inappropriate to improve curing performance.

  • PDF

국부 근접 난방 모듈을 이용한 전기차 탑승자의 열쾌적성에 대한 실험적 연구 (Experimental study on Thermal Comfort of Electric Vehicle Occupants Using Local Proximity Heating Module)

  • 이채열 ;임종한;이재욱;박상희
    • 한국산업융합학회 논문집
    • /
    • 제27권3호
    • /
    • pp.655-663
    • /
    • 2024
  • In order to meet the technological demand for indoor heating systems that ensure winter thermal comfort during the transition from internal combustion engines to electrification, a localized proximity heating module using surface heating elements was developed. The operational performance of heating module was tested in the low temperature chamber. The experiment conditions were varied by changing the chamber temperature (-10, 0℃), the air flow rate (6.2, 6.0, 4.2m3/h), the heater power (100, 80, 60, 40W). Thermal comfort model was confirmed using the CBE Thermal Comfort Tool applying ASHRAE standard 55. Under -10℃ condition, thermal comfort was satisfied at 23.4, 23.2℃ at power of 100W and air flow rate 6.0, 4.6m3/h. Under 0℃ condition, at power of 80W, air flow rate 6.2, 6.0m3/h, and at power of 60W, air flow rate 4.6m3/h showed results of 25.7, 26.1, 23.0℃, respectively, satisfying thermal comfort. This study analyzed the operating performance of the local proximity heating module in the low temperature chamber and applied thermal comfort model to prove applicability of local proximity heating module using surface heating elements and how to utilize the thermal comfort model.

The Relationship between Local Distribution and Abundance of Butterflies and Weather Factors

  • Choi, Sei-Woong
    • The Korean Journal of Ecology
    • /
    • 제26권4호
    • /
    • pp.199-202
    • /
    • 2003
  • According to the energy hypothesis, the energy input per unit area primarily determines species richness in regions of roughly equal area. Some energy-related ecological research included identification of major climatic variables to determine regional species richness. In this study, the local butterfly species richness was examined to find out whether weather variables affected the local distribution or abundance of butterfly populations. Butterfly monitoring data from May 2001 to April 2002 taken at Mt. Yudal, Mokpo, in the southwestern part of Korea, and six weather variables (monthly mean values of temperature, precipitation, evaporation, wind speed, air pressure, and sunlight) were analyzed. Multiple regression analysis showed that only temperature explained 80% and 70% of the variability of log-transformed number of species and individuals, respectively, indicating that temperature played an important role in local species richness. Furthermore, global warming could affect the abundance and distribution of butterflies regionally as well as locally.

수평평활관내의 비공비 혼합냉매의 응축에 대한 예측모델 (A Prediction Model for Condensation of Zeotropic Refrigerant Mixtures Inside a Horizontal Smooth Tube)

  • 이상무;박병덕
    • 설비공학논문집
    • /
    • 제13권4호
    • /
    • pp.262-270
    • /
    • 2001
  • This paper deals with a prediction method for the condensation of ternary refrigerant mixture inside a horizontal smooth tube. Based on some reliable assumptions, the governing equations for the local heat and mass transfer characteristics are derived, and the prediction for the condensation of ternary zeotropic refrigerant mixtures composed of HFC32/HFC125/HFC134a, including R407C, is carried out. The local values of vapor quality, thermodynamic states at bulk vapor, vapor-liquid interface and bulk liquid, mass flux etc. are obtained for a constant wall temperature and a constant wall heat flux conditions, and the effects of the composition of HFC32/HFC125/HFC134a on heat transfer characteristics are examined. The prediction result is also compared with experimental data for condensation of ternary refrigerant mixtures. The predicted wall temperature distribution has a similar trend with experimental data but the predicted local heat transfer coefficients are 20-30% higher than the experimental data.

  • PDF

Forced Convection Boiling Heat Transfer from a Horizontal Cylinder to Subcooled Water

  • Lee, Sung-Hong;Lee, Euk-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제7권
    • /
    • pp.79-90
    • /
    • 1999
  • This investigation presents the experimental results of forced convection boiling heat transfer around a circular, electrically heated horizontal cylinder to subcooled water in cross flow. In these experiments, the following primary variables were included: heat flux, flow velocity, pressure and degree of subcooling at inlet. Local surface temperatures were measured at nine peripheral positions. Local surface temperature distributions are classified into four categories depending on the supplied heat flux. The effects of the boiling curve depending on the fluid velocity, degree of subcooling at inlet and pressure are presented.

  • PDF

지리산 개서어나무림에서의 12년간 지역기후의 변화에 따른 연간 종자생산량의 변동 (Twelve Years Changes in Local climate Factors and Annual fluctuations of Seed Production of the Carpinus tschonoskii Forest in Mt. jiri in Southern Korea)

  • 임영득;홍선기
    • The Korean Journal of Ecology
    • /
    • 제21권6호
    • /
    • pp.809-814
    • /
    • 1998
  • Changes of annual seed production related to climate change were studied for 12 years in Piagol, a riparian valley in Mt. Jiri. Sixty-four seed traps (sized 0.5 ${\times}$ 0.5 $m^{2}$) were set up on the forest floor of surveyed area. Seeds were collected from these traps at an interval of 15 days from September to November since 1984. Vegetation of the study area was mainly consisted of the naturally regenerated Carpinus tschonoskii in the tree layer. Acer mono, Quercus serrata, Carpinus laxiflora and Symplocos chinensis also appeared in the same layer. Maximum production occurred in 1984 and 1994. As a result of comparing seed production with local climate factors for 12 years, seed productivity and the year of maximum production of Carpinus forest were merely related with precipitation, air temperature and duration of sunshine among local climate factors. Duration of sunshine was, however, not contributed to periodically high productivity of seed of riparian valley carpinus forest.

  • PDF