• Title/Summary/Keyword: loading protocol

Search Result 100, Processing Time 0.035 seconds

Mandibular Mini-Implants Supported Overdentures: A Case Report (미니 임플란트를 이용한 하악의 임플란트 지지 피개의치: 증례보고)

  • Park, Jin-Hong;Lee, Jeong-Yol;Shin, Sang-Wan
    • Implantology
    • /
    • v.19 no.3
    • /
    • pp.146-152
    • /
    • 2015
  • Mini-dental implants for overdenture applications are increasingly popular due to their ease in placement with simplified, less traumatic surgical protocols in limited-width alveolar ridges. However, the clinical decisions including implant number, position, and loading protocol must be based on a thorough evaluation and evidence-based diagnosis. Herein, we reported a case treated with the current method of mandibular mini-implant supported overdenture.

Does matching relation exist between the length and the tilting angle of terminal implants in the all-on-four protocol? stress distributions by 3D finite element analysis

  • Li, Xiaomei;Cao, Zhizhong;Qiu, Xiaoqian;Tang, Zhen;Gong, Lulu;Wang, Dalin
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.3
    • /
    • pp.240-248
    • /
    • 2015
  • PURPOSE. To explore whether there is matching relation between the length and the tilting angle of terminal implants in the All-on-Four protocol by studying the effects of different implant configurations on stress distributions of implant, bone, and framework. MATERIALS AND METHODS. Four implants were employed to support a full-arch fixed prosthesis and five three-dimensional finite element models were established with CT images, based on the length (S and L) and distal tilt angle ($0^{\circ}$, $30^{\circ}$ and $45^{\circ}$) of terminal implants for an edentulous mandible, which named: Tilt0-S, Tilt30-S, Tilt30-L, Tilt45-S and Tilt45-L. An oblique 240 N was loaded at second molar. The von Mises Stresses were analyzed. The implants were consecutively named #1 to #4 from the loading point. RESULTS. 1) Tilt0-S had the greatest stress on the implants, with the other groups exhibiting variable reductions; the four implants of Tilt45-L demonstrated the greatest reduction in stress. 2) Tilt0-S had the greatest stress at bone around #1 implant neck, and Tilt45-L exhibited the least stress, which was a 36.3% reduction compared to Tilt0-S. 3) The greatest stress in the framework was found on the cantilevers distal to #1 implant. Tilt45-S exhibited the least stress. CONCLUSION. Matching different length and tilting angle of the terminal implants led to variable stress reductions on implants, bone and the superstructure. By optimizing implant configuration, the reduction of stress on implants and surrounding bone could be maximized. Under the present condition, Tilt45-L was the preferred configuration. Further clinical testings are required.

An advanced key distribution mechanism and security protocol to reduce a load of the key management system (키 관리시스템의 부하절감을 위한 향상된 키 분배 메커니즘과 보안프로토콜)

  • Jeon, Jeong-Hoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.11 no.6 s.44
    • /
    • pp.35-47
    • /
    • 2006
  • In an Ubiquitous Environment, the growth of various services and equipment is forecasted to increase both the multicast users and diverse hacking attacks of the multicast key. Rapid increasing of multicast users and application security protocols reduce the performance of the Central key management system. Accordingly. We propose to elevate the functionality of the key management mechanism for greater efficiency and stability of the multicast services. in this paper The existing key management mechanism comparison and simulation will analyze these problems. We propose the advanced SMKD (Secure Multicast Key Distribution) mechanism application of the small group and key length control new security protocol by methods to solve these problems. The SMKD Model in this paper will help reduce loading the key distribution and encryption execution of a central key management system, and this model can also ensure stability to a central key management system by efficient key management.

  • PDF

The effect of undersizing and tapping on bone to implant contact and implant primary stability: A histomorphometric study on bovine ribs

  • Di Stefano, Danilo Alessio;Perrotti, Vittoria;Greco, Gian Battista;Cappucci, Claudia;Arosio, Paolo;Piattelli, Adriano;Iezzi, Giovanna
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.3
    • /
    • pp.227-235
    • /
    • 2018
  • PURPOSE. Implant site preparation may be adjusted to achieve the maximum possible primary stability. The aim of this investigation was to study the relation among bone-to-implant contact at insertion, bone density, and implant primary stability intra-operatively measured by a torque-measuring implant motor, when implant sites were undersized or tapped. MATERIALS AND METHODS. Undersized (n=14), standard (n=13), and tapped (n=13) implant sites were prepared on 9 segments of bovine ribs. After measuring bone density using the implant motor, 40 implants were placed, and their primary stability assessed by measuring the integral of the torque-depth insertion curve. Bovine ribs were then processed histologically, the bone-to-implant contact measured and statistically correlated to bone density and the integral. RESULTS. Bone-to-implant contact and the integral of the torque-depth curve were significantly greater for undersized sites than tapped sites. Moreover, a correlation between bone to implant contact, the integral and bone density was found under all preparation conditions. The slope of the bone-to-implant/density and integral/density lines was significantly greater for undersized sites, while those corresponding to standard prepared and tapped sites did not differ significantly. CONCLUSION. The integral of the torque-depth curve provided reliable information about bone-to-implant contact and primary implant stability even in tapped or undersized sites. The linear relations found among the parameters suggests a connection between extent and modality of undersizing and the corresponding increase of the integral and, consequently, of primary stability. These results might help the physician determine the extent of undersizing needed to achieve the proper implant primary stability, according to the planned loading protocol.

Application of dental implant for orthodontic anchorage (보철 수복용 임플란트의 교정치료를 위한 고정원의 활용)

  • Kang, Hyo-Jin;Park, Eun-Jin;Kim, Sun-Jong;Pang, Eun-Kyoung
    • The Journal of the Korean dental association
    • /
    • v.54 no.6
    • /
    • pp.404-413
    • /
    • 2016
  • Currently, dental implants have become predictable and reliable adjuncts for oral rehabilitation. Osseointegrated implants can be used to provide rigid orthodontic anchorage and have advantages compared conventional orthodontic anchorage especially when there were edentulous areas and implants were scheduled as a treatment plan. Orthodontic force doesn't cause the bone loss of osseointegrated implants. Implant materials, surgical protocols and healing time before loading follow the conventional treatment protocol. Because the implants, once installed, can't change the location, meticulous treatment planning should be preceded. Further investigations are needed to standardize the treatment protocol.

  • PDF

SDN/NFV Based Web Cache Consistency and JavaScript Transmission Acceleration Scheme to Enhance Web Performance in Mobile Network (모바일 네트워크에서 SDN/NFV 기반의 웹 성능 향상을 위한 웹 캐시 일관성 제공과 JavaScript 전송 가속화 방안)

  • Kim, Gijeong;Lee, Sungwon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39B no.6
    • /
    • pp.414-423
    • /
    • 2014
  • The number and size of resource constituting the web page has been increasing steadily, and this circumstance leads to rapidly falling quality of web service in mobile network that offer relatively higher delay. Moreover, Improving the quality of a web services protocol is difficult to provide network function because the current network architecture has closed structure. In this paper, we suggest schemes to enhance web performance in mobile network, which are Check Coded DOM scheme and Functional JavaScript Transmission scheme, and then try to seek idea which can be provided suggested schemes as a network function using NFV(Network Function Virtualization). For the performance evaluation and analysis about the suggested schemes, we perform network simulation using SMPL library. We confirm that suggested schemes offer better performance in term of page loading time, the number of message and the amount of traffic in the network than HTTP Protocol.

Comparison of the Anaerobic Threshold Level Between Subjects With and Without Non-Specific Chronic Low Back Pain (비특이성 만성요통 유무에 따른 무산소성 역치수준 비교)

  • Seong, Jun-Hyuk;Kwon, Oh-Yun;Yi, Chung-Hwi;Cynn, Heon-Seock;Cho, Young-Ki
    • Physical Therapy Korea
    • /
    • v.18 no.1
    • /
    • pp.74-82
    • /
    • 2011
  • The purpose of this study was to compare the anaerobic threshold (AT) between subjects with and without non-specific chronic low back pain (NCLBP). The patient group included 15 women with NCLBP. The normal group included 15 women without NCLBP who were age-, height-, weight-, and activity level-matched. The subjects performed a Balke treadmill protocol which was symptom-limited progressive loading test. Their heart rate (HR), ventilatory gas and metabolic equivalents (METs) were measured using the automatic breath gas analyzing system. After the test, each subjects' ratings of perceived exertion (RPE) were evaluated. The visual analog scale (VAS) was assessed pre- and post-test. The independent t-test and Wilcoxon's signed-rank test were used for analysis of the data. Time, HR, the volume of oxygen consumption ($VO_2$), relative $VO_2$, and METs at the AT level of the patient group were significantly lower than those of the healthy group (p<.05). However, there were no significant differences in RPE, VAS, and breathing frequency at the AT level (p>.05). The findings of this study indicate that patients with NCLBP had a lower aerobic fitness than healthy subjects. Thus, implementation of rehabilitation program to increase aerobic fitness may be considered in patietns with NCLBP, and further studies are required to determine the etiological factors of decreased aerobic fitness.

Main/Sub Device Authentication and Authorization Protocol in Ubiquitous Office Network (유비쿼터스 오피스 네트워크에서의 Main/Sub 디바이스 인증/인가 프로토콜)

  • Moon, Jong-Sik;Lee, Im-Yeong
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.19 no.5
    • /
    • pp.105-118
    • /
    • 2009
  • In modern society, as the rapid development of IT technology combined with the computer-based high-speed communication networks makes it possible to provide a wide spectrum of services and devices, we have been confronting a new cultural transformation era, referred to as the information society. However, the requirements to be considered in security aspect have became more complicated and diversified, and there remains the same security weaknesses as in the existing media or protocol. Particularly, the office network device with roaming is susceptible to the different kinds of attacks such as terminal hacking, virus attacks, and information leakage because the computing capacity is relatively low and the loading of already developed security functions is difficult. Although developed as one solution to this problems, PKI security authentication technology isn't suitable for multi-domain environments providing uonments proffice network service, and so the development of a novel authentication system is needed. Therefore, in this paper researched the roaming and device authentication/auth for multitechnology using an ID-based public key, authorization ticket, and Sub-device ticket with a purpose to contribute to the development of the secured and efficient technology.

Practical Application of Cryopreservation of In Vitro Grown Shoot Tips of Strawberry (Fragaria × ananassa Duch.) using Droplet-Vitrification

  • Jinjoo Bae;Young-Yi Lee;Jae-Young Song;Jung-Ro Lee;Munsup Yoon
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2021.04a
    • /
    • pp.36-36
    • /
    • 2021
  • Cryopreservation has been broadly used as an efficient method for a long-term conservation for many types of plants especially vegetatively propagated plants. Among several cryopreservation methods, a droplet-vitrification was the most widely applicable and efficient method. Studies have developed protocols for strawberry using droplet-vitrification method and suggested the practical use of the protocol for large number of germplasm with a little modification. In this study, the droplet vitrification method of shoot tip has been tested on 31 accessions provided around the world. Shoot tips were precultured on Murashige and Skoog (MS) liquid medium supplemented with 0.3~0.5M sucrose. Precultured explants were osmoprotected with loading solution, 35% of PVS3 (C4, 17.5% glycerol and 17.5% sucrose) for 40 min and exposed to dehydration solution, PVS3 (B1, 50% glycerol and 50% sucrose) for 60 min. Then, the explants were transferred onto droplets containing 2.5 uL PVS3 on sterilized aluminum foils prior to direct immersion in liquid nitrogen (LN) for 1hr. The cryopreserved shoot tips were rapidly warmed in a water bath at 40C and then unloaded in MS with 0.8M sucrose for 40 min. The shoot tips were cultured in NH4NO3-free MS post culture medium for 2 weeks. Subsequently, the explants were moved to the MS medium for 6 weeks and evaluated the regrowth rate. By this droplet-vitrification protocol, twenty-four accessions showed at least 40% regrowth rate. Out of 24 accessions, 'Nonsan1ho' had the highest regeneration rate of 85.8% and 'Jumbo pureberry' had the lowest with 42.1%.

  • PDF

Development of Multi-channels NMEA0183 Indicator System (다채널 NMEA0183 인디케이트 시스템 개발)

  • Kim, Gwan-Hyung;Oh, Am-Suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.11
    • /
    • pp.2327-2332
    • /
    • 2011
  • Recently, the increase of loading amount on cargo ships due to the automation of loading process results in much complex ship operation. For this reason, NMEA-0183 based on RS-422,485 and NMEA-2000 based on CAN communication methods have been usually used as a standardized method in the marin electric interfacing equipments. In this paper, a general NMEA-0183 protocol was designed to support 7-channel NMEA-0183 serial communication data, which can receive 3-channel 16 bits ADC and 2-channel pulse using SPI(Serial Peripheral Interface). In particular, this method was designed for ship communication requires 7 important factors. Also in this study, using the minimization of the proposed method and realizing the monitoring system based on PC, the effectiveness of multichannel indicator system was proposed.