• Title/Summary/Keyword: loading protocol

Search Result 100, Processing Time 0.039 seconds

Numerical investigation of cyclic performance of frames equipped with tube-in-tube buckling restrained braces

  • Maalek, Shahrokh;Heidary-Torkamani, Hamid;Pirooz, Moharram Dolatshahi;Naeeini, Seyed Taghi Omid
    • Steel and Composite Structures
    • /
    • v.30 no.3
    • /
    • pp.201-215
    • /
    • 2019
  • In this research, the behavior of tube-in-tube BRBs (TiTBRBs) has been investigated. In a typical TiTBRB, the yielding core tube is located inside the outer restraining one to dissipate energy through extensive plastic deformation, while the outer restraining tube remains essentially elastic. With the aid of FE analyses, the monotonic and cyclic behavior of the proposed TiTBRBs have been studied as individual brace elements. Subsequently, a detailed finite element model of a representative single span-single story frame equipped with such a TiTBRB has been constructed and both monotonic and cyclic behavior of the proposed TiTBRBs have been explored under the application of the AISC loading protocol at the braced frame level. With the aid of backbone curves derived from the FE analyses, a simplified frame model has been developed and verified through comparison with the results of the detailed FE model. It has been shown that, the simplified model is capable of predicting closely the cyclic behavior of the TiTBRB frame and hence can be used for design purposes. Considering type of connection detail used in a frame, the TiTBRB member which behave satisfactorily at the brace element level under cyclic loading conditions, may suffer global buckling due to the flexural demand exerted from the frame to the brace member at its ends. The proposed TiTBRB suit tubular members of offshore structures and the application of such TiTBRB in a typical offshore platform has been introduced and studied in a single frame level using detailed FE model.

Improvement of Straw Loading Method on Survival of Mouse IVF/IVC Blastocysts Cryopreserved by Vitrification (체외수정과 체외배양에서 생산된 생쥐 배반포기배의 초자화 동결에 있어서 Straw Loading 방법의 개선)

  • 김선의;엄상준;김은영;윤산현;박세필;임진호
    • Korean Journal of Animal Reproduction
    • /
    • v.20 no.1
    • /
    • pp.35-42
    • /
    • 1996
  • This study was carried out to investigate the effect of straw loading method and thawing protocol on the in vitro development of in vitro produced mouse blastocysts cryopreserved by vitrification. Three loading types of straw I, Il and III on loading and sealing method were made for vitrification. The ability of the solution on straw loading methods to remain vitreous during warming was tested by exposed in air for 1 to 10 s sec. and then plunged the vitrified straws into water bath at 25°C. Embryos to be vitrified were equilibrated to the 20% EG for 5min. and exposed in EFS 40 for 1min. The plug ends of Straw I and Straw II were sealed with straw powder and Straw III was treated straw powder, followed by heat sealing and then plunged into LN$_2$. The results obtained in these experiments were summarized as follows; 1) Straw I embryo column mostly changed from transparent to opaque upon thawing without exposure in air for 3-6 sec. Straw II embryo column was I improved partially but was not remained completely vitreous during warming. However, when Straw lll loading method was used, the embryo column was remained vitreous completely. 2) High survival rates and development rates of each groups (middle blastocysts and hatching blastocysts) of vitrified embryos were obtained by using Straw III loading method than Straw I method (P<0.05). And the range of s standard error was low in Straw lll method. 3) When the embryos vitrified-frozen were placed in air for 3, 5 and l0sec. and then warmed rapidly in water bath at 25$^{\circ}C$, the survival rates after 24h of culture were 72.7-87.1% and the development rates to hatching stage after 48h of culture were 34.0-48.4%. There were no significantly differences according to exposure time in air during warming. In conclusion, the present results showed that highly survival and low standard error of vitrified-frozen mouse bIastocysts were obtained by using straw lll loading, double sealing and appropriate 2 step warming method.

  • PDF

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF $BR{\AA}NEMARK\;NOVUM^{(R)}$ IMMEDIATE IMPLANT PROSTHODONTIC PROTOCOL ($Br{\aa}nemark\;Novum^{(R)}$ 즉시 임플랜트 보철 수복 방법에 관한 삼차원 유한요소 분석적 연구)

  • Kim Woo-Young;Kim Yung-Soo;Jang Kyung-Soo;Kim Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.5
    • /
    • pp.463-476
    • /
    • 2001
  • Since the treatment of edentulous patients with osseointegrated implant was first introduced more than 30 years ago, implant therapy has become one of the most important dental treatment modalities today. Based on the previous experience and knowledge, $Br{\aa}nemark\;Novum^{(R)}$ protocol was introduced with the concept of simplifying surgical and prosthetic technique and reducing healing time recently. This protocol recommends the installation of three 5mm wide diameter futures in anterior mandible and the prefabricated titanium bars for superstructure fabrication. This study was designed to analyze the stress distribution at fixture and superstructure area according to changes of fixture number, diameter and superstructure materials. Four 3-dimensional finite element models were fabricated. Model 1 - 5 standard fixtures (13mm long and 3.75mm in diameter) & superstructure consisted of type IV gold alloy and resin Model 2- 3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of type IV gold alloy and resin Model 3-3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of titanium and resin Model 4-3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of titanium and porcelain A 150N occlusal force was applied on the 1st molar of each model in 3 directions - vertical($90^{\circ}$), horizontal($0^{\circ}$) and oblique($120^{\circ}$). After analyzing the stresses and displacements, following results were obtained. 1. There were no significant difference in stress distribution among experimental models. 2. Model 2, 3, 4 showed less amount of compressive stress than that of model 1. However, tensile stress was similar. 3. Veneer material with a high modulus of elasticity demonstrated less stress accumulation in the superstructure. Within the limites of this study, $Br{\aa}nemark\;Novum^{(R)}$ protocol demonstrated comparable biomechanical properties to conventional protocol.

  • PDF

Effect of Implant Length on the Immediate Loading at the Anterior Maxilla (즉시하중시 상악 전치부에 식립된 임플란트 길이 변화에 따른 응력 분포의 삼차원 유한요소 연구)

  • Lee, Joon-Seok;Kim, Myung-Joo;Kwon, Ho-Beom;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.3
    • /
    • pp.255-265
    • /
    • 2009
  • Recently many studies have been published on application of immediate loaded implants. However, the immediate loading protocol has not been well documented. The purpose of the present study was to evaluate the stress distribution between bone-implant interfaces and the effect of implant length in the anterior maxilla using 3 dimensional finite element analyses. The diameter 4.0 mm threaded type implants with different length(8.5 mm, 10.0 mm, 11.5 mm, 13.0 mm, 15.0 mm) were used in this study. The bone quality of anterior maxillary bone block was assumed to D3 bone. Bone-implant interfaces of immediately loaded implant were constructed using a contact element for simulating the non osseointegration status. For simplification of all the processing procedures, all of the material assumed to be homogenous, isotropic, and linearly elastic. The 178 N of static force was applied on the middle of the palatoincisal line angle of the abutment with $120^{\circ}$ angle to the long axis of abutment. Maximum von Mises stress were concentrated on the labial cortical bone of the implant neck area, especially at the cortical-cancellous bone interfaces. Compared the different length, highest peak stress value was observed at the 8.5 mm implants and the results indicated a tendency towards favorable stress distribution on the bone, when the length was increased. Presence of cortical bone was very important to immediate loading, and it appears that implants of a length more than 13 mm are preferable for immediate loading at the anterior maxilla.

Rehabilitation after operation

  • 최창혁
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2003.11a
    • /
    • pp.84-90
    • /
    • 2003
  • 최근 견관절 질환 치료의 발전에 힘입어 술 후의 유병율을 줄이고, 보다 견고한 조직 복원이 가능해 짐으로써 운동사슬(kinetic chain)의 생리적이고 생 역학적인 복원을 위한 재활치료를 조기에 시행할 수 있게 되었다. 이러한 조기재활 치료는 술 전 적절한 준비, 해부학적인 수술적 치료, 술 중 적절한 운동범위의 회복, 술 후 조기 보조 및 능동 보조운동, closed chain-axial loading rehabilitation protocol, 재활치료 중 기능적 관절위치 유지 및 기능회복에 따른 생리적 호전 등의 원칙을 통해 견관절의 여러 질환의 재활치료에 적용할 수 있다. 견관절의 조기 재활치료 시 통증은 근육의 조화운동을 저해하게 되며 관절의 안정적인 운동과 기능을 방해하게 된다. 따라서 시각 측정표를 이용한 4이하의 통증범위에서, 관절의 위치와 팔 및 몸의 운동 그리고 근육의 작용을 잘 관찰하는 가운데 운동을 함으로써 통증으로 인한 근억제 효과를 줄이며, 보다 조기에 안전하게 일상생활 및 운동복귀를 할 수 있다.

  • PDF

Development of a Portable Device based on PDA for Vibration Signal Analysis (PDA 기반 포터블 진동 신호 분석기 개발)

  • 김동준;박광호;기창두
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.12
    • /
    • pp.179-184
    • /
    • 2002
  • In this study, we developed a portable device which can monitor and analyze vibration signals from machines. This system consists a PDA loading the program for vibration analysis and A/D board for vibration acquisition. A PDA is smaller than the palm of the hand, but it has a powerful computing ability as much as an IBM compatible PC with a Pentium 100MHz CPU. The A/D board developed in this study supports LAN interface using TCP/IP communication protocol. The application program for vibration analysis includes signal processing module, fault diagnosis module, data store module, and plot display module. MS visual embedded C++ 3.0 was used to developed the program.

A Design on the Digital Protective Relay System for Generator Fault Diagnosis (발전기 고장진단을 위한 디지털보호계전 시스템 설계)

  • Lee, Sung-Hwan;Jang, Nak-Won;Yi, Dong-Young
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.717-718
    • /
    • 2008
  • We developed the protection program for the generator fault protection system and each module of the digital protective relay H/W for loading the protection program. The protective algorithm for the generator is 51, 51G/N, 46P/N, 47P/N, 50G/N, and 32, and we developed each fault protection program. And we must design high efficiency microprocessor, CT, and PT for realtime measuring, relaying and high accuracy of measurement, also. From now on digital protective relay must be operated with integrated management systems. For this point, we must load various industrial protocol on the digital protective relay. In this research, we developed each protective relay H/W module according to above conditions. And we designed real-time operating system in order that each protective algorithm is operated with realtime processing on the H/W system.

  • PDF

Design and Implementation of IEEE 802.21 Media Independent Handover Protocol (IEEE 802.21 Media Independent Handover 프로토콜의 설계 및 구현)

  • Song, In-Jae;Lee, Sung-Won
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2011.06d
    • /
    • pp.295-298
    • /
    • 2011
  • 최근 모바일 디바이스 이용자가 증가하면서 모바일 트래픽이 급격하게 증가하고 있으며 이로 인한 네트워크 과부하 문제가 대두되고 있다. 이를 해결하기 위해 이동통신 사업자들은 WiFi 핫스팟 등의 인프라 증설을 통해 트래픽 분산(off-loading)효과를 기대 하지만 3G, WiFi 등 이기종 네트워크간 이동성이 고려되지 않은 상태에서 사용자들의 요구를 만족시키기 어렵다. 본 논문에서는 이기종 네트워크간 심리스 핸드오버를 위한 IEEE 802.21 Media Independent Handover(MIH) 표준을 기반으로 MIH 프레임워크에 대해 살펴보고 구현 관점에서 MIH 프로토콜을 위한 시스템 설계와 프로토타입을 제시한다.

Physical Therapy Following Leg Lengthening and Deformity Correction by Ilizarov Method : Clinical Commentary (Ilizarov 술식을 이용한 하지 연장술 및 변형 교정술 후 물리치료)

  • Kim, Tae-Youl;Hwang, Tae-Yeun
    • Journal of Korean Physical Therapy Science
    • /
    • v.1 no.2
    • /
    • pp.355-365
    • /
    • 1994
  • Ilizarov limb lengthening has been the new method to deal with a variety of orthopaedic problems. Ilizarov apparatus consists of stainless steel rings that surround the limb and are interconnected by threaded rods. Tensioned wires pierce the bone in the plane of each ring and are tightly attached to the ring. Ilizarov has reported distraction osteogenesis with the use of the typical fixator that allows functional loading. The purpose of this commentary is to introduce a four-stage rehabilitation protocol currently used by the authors in the physical therapy management of a post -limb lengthening. Each treament stage corresponds to a medical stage in the lengthening process. Treatment goals for each of the physical therapy treatment stage are presented to guide treatment planning. Two case examples are presented to illustrate the use of the management goals in treatment planning.

  • PDF

Development of new inner diaphragms for a H-beam and composite box column joint

  • Khan, Mahbub;Uy, Brian;Kim, Jin W
    • Steel and Composite Structures
    • /
    • v.42 no.3
    • /
    • pp.363-373
    • /
    • 2022
  • This paper presents an experimental and a numerical investigation of a H-beam - composite box column joint fabricated with two new inner diaphragms and a continuous inner diaphragm. The main objective of the current research project is to investigate the structural performance of the newly developed inner diaphragms under a cyclic loading protocol. Hysteretic behaviour of the composite joints is analysed to investigate the structural performance of the new and continuous inner diaphragms. This paper compares the result of the finite element (FE) models with the new and continuous inner diaphragms against their counterpart experimental results. To produce a design criterion for the newly developed inner diaphragms, yielding or failure area of the inner diaphragms under tensile stress is analysed from the FE results.