• Title/Summary/Keyword: load-slip

검색결과 514건 처리시간 0.03초

경수 및 공기중에서의 지르칼로이-4 튜브의 프레팅 마멸특성 비교 (A Comparison of Fretting Wear Characteristics of Zircaloy-4 Tube in Light Water and in Air)

  • 조광희;김태형;김석삼
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1999년도 제29회 춘계학술대회
    • /
    • pp.303-309
    • /
    • 1999
  • The fretting wear behaviour of Zircaloy-4 tube used as the fuel rod cladding in PWR nuclear power plants has been investigated at the different test environment, in light water and in air as a function of slip amplitude, normal load, test duration and frequency. Zircaloy-4 tubes were used for both of oscillating and stationary specimens. A fretting wear tester was designed to be suitable for this fretting test. The wear volume and specific wear rate of Zircaloy-4 tube in water were greater than those in air under various slip amplitude. It was found that delaminate debris and surface cracks were observed at low slip amplitude and high load in water Experimental results showed that the light water accelerated the wear of Zircaloy-4 tube at low slip amplitude in fretting.

  • PDF

Fuzzy Technique based Chopper Control for Slip Energy Recovery System with Twelve-Pulse Converter

  • Tunyasrirut, S.;Ngamwiwit, J.;Furuya, T.;Yamamoto, Y.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.509-514
    • /
    • 2004
  • This paper introduces the modified slip energy recovery system in order to improve its power factor and to reduce harmonics of line current waveforms. Twelve pulse line commutated converter with the chopper type IGBT is applied where the chopper is applied across the DC terminal and the chopped DC is fed to the converter operating as an inverter and then passed through the wye-wye and delta-wye transformer circuit. This scheme leads to be able to adjust the speed of the motor by the duty cycle of the chopper operating in PWM mode. The fuzzy logic controller is also introduced to the modified slip energy recovery system for keeping the motor speed to be constant when the load varies. The experimental results in testing the 0.22 kW wound rotor induction motor from no-load condition to rated condition show the effectiveness of the proposed control scheme.

  • PDF

경수중에서 지르칼로이-4 튜브의 프레팅 마멸특성 (Fretting Wear Characteristics of Zircaloy-4 Tube in Light Water)

  • 조광희;노규철;김석삼;조성재
    • Tribology and Lubricants
    • /
    • 제14권4호
    • /
    • pp.88-94
    • /
    • 1998
  • The fretting wear characteristics of Zircaloy-4 tube in light water were investigated experimentally. A fretting wear tester was designed to be suitable for this fretting test. This study was focused on the effects due to the combination of normal load, slip amplitude and number of cycles as the main factors of fretting. The results of this study showed that the wear volume increased abruptly at slip amplitude above 100 ${\mu}{\textrm}{m}$, which is defined as critical slip amplitude of Zircaloy-4 tube in light water, and that under 160 ${\mu}{\textrm}{m}$ the wear volume decreased as load increased at the same slip amplitude.

경수중에서 지르칼로이-4 튜브의 프레팅 마멸특성 (Fretting Wear Characteristics of Zircaloy-4 Tube in Light Water)

  • 조광희;노규철;김석삼;조성재
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1998년도 제27회 춘계학술대회
    • /
    • pp.55-63
    • /
    • 1998
  • The fretting wear characteristics of Zircaloy-4 tube in light water were investigated experimentally. A fretting wear tester was designed to be suitable for this fretting test. This study was focused on the effects due to the combination of normal load, slip amplitude and number of cycles as the main factors of fretting. The results of this study showed that the wear volume increased abruptly at slip amplitude above 100$\mu$m, which is defined as critical slip amplitude of Zircaloy-4 tube in light water, and that under 160$\mu$m the wear volume decreased as load increased at the same slip amplitude.

  • PDF

비탄성 변형 이론을 바탕으로 한 Mg-Al 합금의 슬립기구 천이 현상 해석 (Effect of slip system transition on the deformation behavior of Mg-Al alloy: internal variable based approach)

  • 이현석;방원규;장영원
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2004년도 춘계학술대회 논문집
    • /
    • pp.186-189
    • /
    • 2004
  • Although magnesium has high potential for structural material due to the lightweight and high specific strength, the structural application has been limited by the low ductility at room temperature. The reason of the poor ductility is few activated slip systems of magnesium (HCP structure) during deformation. As temperature increases, however, additional non-basal slip systems are incorporated to exhibit higher ductility comparable to aluminum. In the present study, a series of tensile tests of Mg-Al alloy has been carried out to study deformation behavior with temperature variation. Analysis of load relaxation test results based on internal variable approach gave information about relationship between the micromechanical character and corresponding deformation behavior of magnesium. Especially, the material parameter, p representing dislocation permeability through barriers was altered from 0.1 to 0.15 as the non-basal slip systems were activated at high temperature.

  • PDF

지르칼로이-4 튜브 프레팅 마멸 특성의 환경 의존성과 마멸기구 (Comparison of Fretting Wear Characteristics of Zircaloy-4 Tube in Light Water and in Air)

  • 조광희;김석삼
    • Tribology and Lubricants
    • /
    • 제15권1호
    • /
    • pp.83-89
    • /
    • 1999
  • The fretting wear behaviour of Zircaloy-4 tube used as the fuel rod cladding in PWR nuclear power plants has been investigated at the different test environment, in light water and in air as a function of slip amplitude, normal load, test duration and frequency. Zircaloy-4 tubes were used for both of oscillating and stationary specimens. A fretting wear tester was designed to be suitable for this fretting test. The wear volume and specific wear rate of Zircaloy-4 tube in water was greater than those in air under various slip amplitude. Delaminates and surface cracks were observed at low slip amplitude and high load of fretting test in water, but the traces of adhesion and plowing were observed at and above 200 Um. The water accelerates the wear of Zircaloy-4 tube at lower slip amplitude in fretting.

비탄성 변형 이론을 바탕으로 한 Mg-Al 합금의 슬립기구 천이 현상 해석 (Effect of Slip System Transition on the Deformation Behavior of Mg-Al Alloy: Internal Variable Based Approach)

  • 이현석;장영원;방원규
    • 소성∙가공
    • /
    • 제13권6호
    • /
    • pp.535-539
    • /
    • 2004
  • Although magnesium has high potential for structural material due to the lightweight and high specific strength, the structural application has been limited by the low ductility at room temperature. The reason of the poor ductility is few activated slip systems of magnesium (HCP structure) during deformation. As temperature increases, however, additional non-basal slip systems are incorporated to exhibit higher ductility comparable to aluminum. In the present study, a series of tensile tests of Mg-Al alloy has been carried out to study deformation behavior with temperature variation. Analysis of load relaxation test results based on internal variable approach gave information about relationship between the micromechanical character and corresponding deformation behavior of magnesium. Especially, the material parameter, p representing dislocation permeability through barriers was altered from 0.1 to 0.15 as the non-basal slip systems were activated at high temperature.

미끄러져 넘어짐의 생체학적 연구에 있어서 부하이동이 끼치는 영향 (Load Carrying Effect on the Biomechanical Parameters of Slips and Falls)

  • 명노해
    • 대한산업공학회지
    • /
    • 제27권2호
    • /
    • pp.197-202
    • /
    • 2001
  • The biomechanical analysis of the load carrying effect on different floor surfaces has been conducted. Four different floor surfaces were prepared for ten subjects with each walking at a fixed velocity(1.33 m/sec) while carrying five different loads. The results showed that because of the significant interaction effect between floor slipperiness and the load carrying task, the load carrying effect should be analyzed according to different levels of the floor slipperiness, especially contaminant floors. On oily surfaces, slip distance(SD) and heel velocity (HV) increased whereas stride length(SL) decreased as load increased. In other words, significantly longer SD, faster HV, and no normal gait were found as load increased. As a result, a different protocol should be applied to measure floor slipperiness on oily floors as compared to dry surfaces for tribological approach.

  • PDF

원자스케일 마찰의 하중 및 강성 의존성 (Load and Stiffness Dependence of Atomistic Sliding Friction)

  • 성인하
    • Tribology and Lubricants
    • /
    • 제23권1호
    • /
    • pp.9-13
    • /
    • 2007
  • Despite numerous researches on atomic-scale friction have been carried out for understanding the origin of friction, lots of questions about sliding friction still remain. It is known that friction at atomic-scale always shows unique phenomena called 'stick-slips' which reflect atomic lattice of a scanned surface. In this work, experimental study on the effects of system stiffnesses and load on the atomic-scale stick-slip friction of graphite was performed by using an Atomic Force Microscope and various cantilevers/tips. The objective of this research is to figure out the dependency of atomic-scale friction on the nanomechanical properties in sliding contact such as load, stiffness and contact materials systematically. From this work, the experimental observation of transitions in atomic-scale friction from smooth sliding to multiple stick-slips in air was first made, according to the lateral cantilever stiffness and applied normal load. The superlubricity of graphite could be verified from friction vs. load experiments. Based on the results, the relationship between the stickslip behaviors and contact stiffness was carefully discussed in this work. The results or this work indicate that the atomic-scale stick-slip behaviors can be controlled by adjusting the system stiffnesses and contact materials.

유도전동기(誘導電動機) 구동(驅動)을 위한 부하전류식(負荷轉流式) 전류형(電流型) 인버터의 제어(制御) (The Control of load Commutated Current Source Inverter for Induction Motor Drive)

  • 정연택;심재명;이사영;소용철;이재옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.255-257
    • /
    • 1994
  • The V/F slip frequency constant control methods are used for driving induction motor with load commutated current source inverter, that is. constant V/F and slip frequency driving is used to load commutate the inverter below the critical frequency, while constant voltage and variable frequency and slip frequency driving are used in above the critical region. In order to applicate the load commutated current source inverter to the general use, speed control range of induction noter is selected to two times at rated frequency. Therefore, economical application is possible because of the maximum reduction of the condenser of the inverter output port. The use of the proposed force commutated circuit improves the false operation of force commutated circuit and inverter commutation failure which are produced by the influence of the lower-order harmonics of the conventional load commutated current source inverter at starting.

  • PDF