• 제목/요약/키워드: load-displacement behaviour

검색결과 127건 처리시간 0.027초

Estimation for Primary Tunnel Lining Loads

  • 김학준
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1998년도 터널.암반역학위원회 박사학위 논문집
    • /
    • pp.153-204
    • /
    • 1998
  • Prediction of lining loads due to tunnelling is one of the major issues to be addressed in the design of a tunnel. The objective of this study is to investigate rational and realistic design loads on tunnel linings. factors influencing the lining load are summarized and discussed. The instruments for measuring the lining loads are reviewed and discussed because field measurements are often necessary to verify the design methods. Tunnel construction in the City of Edmonton has been very active for storm and sanitary purposes. Since the early 1970's, the city has also been developing an underground Light Rail Transit system. The load measurements obtained from these tunnels are compared with the results from the existing design methods. However, none of the existing methods are totally satisfactory, Therefore, there is some room for improvement in the prediction of lining loads. The convergence-confinement method is reviewed and applied to a case history of a tunnel in Edmonton. The convergence curves are obtained from 2-D finite element analyses using three different material models and theoretical equations. The limitation of the convergence-confinement method is discussed by comparing these curves with the field measurements. Three-dimensional finite element analyses are performed to gain a better understanding of stress and displacement behaviour near the tunnel face. An improved design method is proposed based on the review of existing design methods and the performance of numerical analyses. A specific method or combination of two different methods is suggested for the estimation of lining loads for different conditions of tunnelling. A method to determine the stress reduction factor is described. Typical values of dimensionless load factors nD/H for tunnels in Edmonton are obtained from parametric analyses. Finally, the loads calculated using the proposed method are compared with field measurements collected from various tunnels in terms of soil types and construction methods to verify the method. The proposed method gives a reasonable approximation of the lining loads. The proposed method is recommended as an approximate guideline for the design of tunnels, but the results should be confirmed by field measurements due to the uncertainties of the ground and lining properties and the construction procedures, This is the reason that in-situ monitoring should be an integral part of the design procedure.

  • PDF

Behaviour of ultra-high strength concrete encased steel columns subject to ISO-834 fire

  • Du, Yong;Zhou, Huikai;Jiang, Jian;Liew, J.Y. Richard
    • Steel and Composite Structures
    • /
    • 제38권2호
    • /
    • pp.121-139
    • /
    • 2021
  • Ultra-high strength concrete (UHSC) encased steel columns are receiving growing interest in high-rise buildings owing to their economic and architectural advantages. However, UHSC encased steel columns are not covered by the modern fire safety design code. A total of 14 fire tests are conducted on UHSC (120 MPa) encased steel columns under constant axial loads and exposed to ISO-834 standard fire. The effect of load ratio, slenderness, stirrup spacing, cross-section size and concrete cover to core steel on the fire resistance and failure mode of the specimens are investigated. The applicability of the tabulated method in EC4 (EN 1994-1-2-2005) and regression formula in Chinese code (DBJ/T 15-81-2011) to fire resistance of UHSC encased steel columns are checked. Generally, the test results reveal that the vertical displacement-heating time curves can be divided into two phases, i.e. thermal expansion and shortening to failure. It is found that the fire resistance of column specimens increases with the increase of the cross-section size and concrete cover to core steel, but decreases with the increase of the load ratio and slenderness. The EC4 method overestimates the fire resistance up to 186% (220 min), while the Chinese code underestimates it down to 49%. The Chinese code has a better agreement than EC4 with the test results since the former considers the effect of the load ratio, slenderness, cross section size directly in its empirical formula. To estimate the fire resistance precisely can improve the economy of structural fire design of ultra-high strength concrete encased steel columns.

Stabilization of backfill using TDA material under a footing close to retaining wall

  • Arefnia, Ali;Dehghanbanadaki, Ali;Kassim, Khairul Anuar;Ahmad, Kamarudin
    • Geomechanics and Engineering
    • /
    • 제22권3호
    • /
    • pp.197-206
    • /
    • 2020
  • Reutilization of solid waste such as Tire Derived Aggregate (TDA) and mixing it with soft soil for backfill material not only reduces the required volume of backfill soil (i.e., sand-mining procedures; reinforcement), but also preserves the environment from pollution by recycling. TDA is a widely-used material that has a good track record for improving sustainable construction. This paper attempted to investigate the performance of Kaolin-TDA mixtures as a backfill material underneath a strip footing and close to a retaining wall. For this purpose, different types of TDA i.e., powdery, shredded, small-size granular (1-4 mm) and large-size granular (5-8 mm), were mixed with Kaolin at 0, 20, 40, and 60% by weight. Static surcharge load with the rate of 10 kPa per min was applied on the strip footing until the failure of footing happened. The behaviour of samples K80-G (1-4 mm) 20 and K80-G (5-8 mm) 20 were identical to that of pure Kaolin, except that the maximum footing stress had grown by roughly three times (300-310 kPa). Therefore, it can be concluded that the total flexibility of the backfill and shear strength of the strip footing have been increased by adding the TDA. The results indicate that, a significant increase in the failure vertical stress of the footing is observed at the optimum mixture content. In addition, the TDA increases the elasticity behaviour of the backfill.

압축응력장 이론을 적용한 콘크리트 유한요소법 개발 (Finite Element Method for Structural Concrete Based on the Compression Field Theory)

  • 조순호
    • 전산구조공학
    • /
    • 제9권1호
    • /
    • pp.151-159
    • /
    • 1996
  • 구조용 콘크리트의 비선형 거동을 예측하기 위하여, 압축강도 연화현상, 거시적 및 회전균열모델등의 내용을 포함하고 있는 압축장 응력장 이론(CFT)에 근거한 유한요소법이 개발/제시되었다. 또한, 이와 관련하여 CFT가 암시하는 탄젠트 및 세칸트 재료강성이 반복계산해법의 관점에서 정의/논의되었다. 최종적으로 계산상의 효율성 증대 및 최대하중 이후의 거동 포착에 주안점을 두어 초기재료 강성을 채택한 변위증분법 논리 및 빠른 수렴을 위한 Over-Relaxtion방법이 Isoparametric계의 8-Node요소에 포함/유도되었다. 이와 같이하여 제시된 비선형 해석 프로그램 NASCOM은 응력 혼돈지역에 위치하는 콘크리트 평면요소의 하중 지지능력, 탄성범위 이후의 변형 특성, 균열양상 및 보강근의 항복범위등의 예측을 가능하게 하였다. NASCOM의 제한된 검증을 위하여, Cervenka의 판넬 시험결과에 대한 하중지지능력 및 변형이력등을 예측한 결과가 전체적인 의미에서 실험결과와 상응하는 일치를 나타내었다.

  • PDF

크기최적화 이후에 나타나는 2차원 얕은 아치 트러스의 후 좌굴 거동의 변화에 대한 연구 (A Study on the Variation of Post Buckling Behaviour of 2-dimensional Shallow Arch Truss after Size Optimization)

  • 이상진;이인수
    • 한국공간구조학회:학술대회논문집
    • /
    • 한국공간구조학회 2008년도 춘계 학술발표회 논문집
    • /
    • pp.107-112
    • /
    • 2008
  • 본 연구에서는 이산계열 대공간구조물의 크기최적화에 따른 후 좌굴거동의 변화에 대하여 조사하고 그 결과를 기술하였다. 본 연구에서는 35개의 부재를 가지는 얕은 아치형 2차원 공간트러스 구조물을 이용하여 연구를 수행하였다. 먼저 트러스의 최적의 부재 크기 패턴을 조사하기 위하여 수학적 프로그래밍 기법을 도입하였다. 이때 최소화해야하는 트러스의 전체 부재의 중량을 목적함수로 이용하고 하중이 가해지는 절점에서 발생하는 변위 값과 각 부재에서 발생하는 응력 값을 허용치 이하로 제한하는 제약조건으로 사용하였다. 크기최적화에서 도출된 트러스 구조물의 후좌굴 거동은 통합 비선형해석기법을 이용하여 조사 분석하였다. 본 연구에서 제시한 결과는 이산계열 대공간구조물의 설계에 기본 데이터로 유용하게 사용될 것으로 판단된다.

  • PDF

Earthquake-resistant rehabilitation of existing RC structures using high-strength steel fiber-reinforced concrete jackets

  • Kalogeropoulos, George I.;Tsonos, Alexander-Dimitrios G.;Konstantinidis, Dimitrios;Iakovidis, Pantelis E.
    • Earthquakes and Structures
    • /
    • 제17권1호
    • /
    • pp.115-129
    • /
    • 2019
  • The effectiveness of an innovative method for the earthquake-resistant rehabilitation of existing poorly detailed reinforced concrete (RC) structures is experimentally investigated herein. Eight column subassemblages were subjected to earthquake-type loading and their hysteretic behaviour was evaluated. Four of the specimens were identical and representative of columns found in RC structures designed in the 1950s-70s period for gravity load only. These original specimens were subjected to cyclic lateral deformations and developed brittle failure mechanisms. Three of the damaged specimens were subsequently retrofitted with innovative high-strength steel fiber-reinforced concrete (HSSFC) jackets. The main variables examined were the jacket width and the contribution of mesh steel reinforcement in the seismic performance of the enhanced columns. The influence of steel fiber volume fraction was also examined using test results of a previous work of Tsonos et al. (2017). The fourth earthquake damaged subassemblage was strengthened with a conventional RC jacket and was subjected to the same lateral displacement history as the other three retrofitted columns. The seismic behaviour of the subassemblages strengthened according to the proposed retrofit scheme was evaluated with respect to that of the original specimens and that of the column strengthened with the conventional RC jacket. Test results clearly demonstrated that the HSSFC jackets effectively prevented the development of shear failure mechanisms, while ensuring a ductile seismic response similar to that of the subassemblage retrofitted with the conventional RC jacket. Ultimately, an indisputable superiority in the overall seismic performance of the strengthened columns was achieved with respect to the original specimens.

Effects of number and angle of T Shape non persistent cracks on the failure behavior of samples under UCS test

  • Sarfarazi, V.;Asgari, K.;Maroof, S.;Fattahi, Sh
    • Computers and Concrete
    • /
    • 제29권1호
    • /
    • pp.31-45
    • /
    • 2022
  • Experimental and numerical simulation were used to investigate the effects of angle and number of T shape non-persistent crack on the shear behaviour of crack's bridge area under uniaxial compressive test. concrete samples with dimension of 150 mm×150 mm×40 mm were prepared. Within the specimen, T shape non-persistent notches were provided. 16 different configuration systems were prepared for T shape non-persistent crack based on two and three cracks. In these configurations, the length of cracks were taken as 4 cm and 2 cm based on the cracks configuration systems. The angle of larger crack related to horizontal axis was 0°, 30°, 60° and 90°. Similar to cracks configuration systems in the experimental tests, 28 models with different T shape non-persistent crack angle were prepared in numerical model. The length of cracks were taken as 4 cm and 2 cm based on the cracks configuration systems. The angle of larger crack related to horizontal axis was 0°, 15°, 30°, 45°, 60°, 75° and 90°. Tensile strength of concrete was 1 MPa. The axial load was applied to the model. Displacement loading rate was controlled to 0.005 mm/s. Results indicated that the failure process was significantly controled by the T shape non-persistent crack angle and crack number. The compressive strengths of the specimens were related to the fracture pattern and failure mechanism of the discontinuities. Furthermore, it was shown that the compressive behaviour of discontinuities is related to the number of the induced tensile cracks which are increased by increasing the crack number and crack angle. The strength of samples decreased by increasing the crack number. In addition, the failure pattern and failure strength are similar in both methods i.e. the experimental testing and the numerical simulation methods (PFC2D).

보강날개로 보강된 수중잠제 지지말뚝의 보강효과 분석 (The Reinforcing Effect of Blade Attached Pile to Support Submerged Breakwater)

  • 정상섬;홍문현;고준영
    • 대한토목학회논문집
    • /
    • 제35권4호
    • /
    • pp.863-874
    • /
    • 2015
  • 본 연구에서는 보강날개로 보강된 수중잠제 지지말뚝의 보강효과를 분석하기 위하여 하중전이거동을 분석하였다. 먼저 3차원 유한요소해석을 통해 말뚝의 변위 및 하중전이곡선(지반반력) 결과로부터 보강효과를 확인하고, 하중전이곡선에서 극한저항력 비율로 보강말뚝의 수평 및 인발하중에 대한 보강계수를 산정함으로써 보강효과를 정량화 하였다. 산정된 보강계수를 쌍곡선 하중전이함수의 극한저항력 $p_u$$t_{max}$에 곱해서 보정상수(fitting parameter)로 적용하여 보강효과를 고려한 하중전이함수를 제안하였다. 제안된 하중전이함수가 수치해석 결과를 잘 반영하고 있는지 확인하기 위해 3차원 유한요소해석을 비교하여 보강말뚝의 하중전이거동을 분석하였다. 제안된 하중전이함수를 하중전이법 해석에 적용하여, 실제 수중잠제를 해석한 결과 보강말뚝의 전단력, 휨 모멘트, 변위가 무보강말뚝보다 작게 발생하고, 지반반력은 더 크게 발생하여 비교적 경제적인 설계가 가능할 것으로 판단된다.

Non-linear analysis of pile groups subjected to lateral loads using 'p-y' curve

  • Chore, H.S.;Ingle, R.K.;Sawant, V.A.
    • Interaction and multiscale mechanics
    • /
    • 제5권1호
    • /
    • pp.57-73
    • /
    • 2012
  • The paper presents the analysis of two groups of piles subjected to lateral loads incorporating the non-linear behaviour of soil. The finite element method is adopted for carrying out the parametric study of the pile groups. The pile is idealized as a one dimensional beam element, the pile cap as two dimensional plate elements and the soil as non-linear elastic springs using the p-y curves developed by Georgiadis et al. (1992). Two groups of piles, embedded in a cohesive soil, involving two and three piles in series and parallel arrangement thereof are considered. The response of the pile groups is found to be significantly affected by the parameters such as the spacing between the piles, the number of piles in a group and the orientation of the lateral load. The non-linear response of the system is, further, compared with the one by Chore et al. (2012) obtained by the analysis of a system to the present one, except that the soil is assumed to be linear elastic. From the comparison, it is observed that the non-linearity of soil is found to increase the top displacement of the pile group in the range of 66.4%-145.6%, while decreasing the fixed moments in the range of 2% to 20% and the positive moments in the range of 54% to 57%.

직류전위차법을 이용한 AISI 316강 시효재의 탄소성 파괴인성 평가 (Evaluation of Elastic-Plastic Fracture Toughness of Aged AISI 316 Steel Using DC-electric Potential Method)

  • 임재규;장진상
    • 대한기계학회논문집A
    • /
    • 제21권3호
    • /
    • pp.519-527
    • /
    • 1997
  • AISI 316 steel has been used extensively for heater and boiler tube of the structural plants such as power, chemical and petroleum plants under severe operating conditions. Usually, material degradation due to microcrack or precipitation of carbides and segregation of impurity elements, is occured by damage accumulated for long-term service at high temperature in this material. In this study, the effect of aging time on fracture toughness was investigated to evaluate the measurement of material degradation. The elastic-plastic fracture toughness behaviour of AISI 316 steel pipe aged at $550^{\circ}C$for 1h-10000h (the aged material) was characterized using the single specimen J-R curve technique and eletric potential drop method at normal loading rate(load-line displacement speed of 0.2mm/min) in room temperature and air environment. The fracture toughness data from above experiments is compared with the $J_{in}$ obtained from predicted values of crack initiation point using potential drop method.