• 제목/요약/키워드: load per unit area

검색결과 47건 처리시간 0.028초

뜬바닥층의 하중조건에 따른 경량충격음 저감량 분석 (Analysis of the Reduction of Light-weight Imapct Noise for Load Condition of Floating Floor)

  • 김명준;이성호;양재훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.356-360
    • /
    • 2006
  • Recently, for the purpose of improving the isolation performance of impact noise, many resilient materials have been installed in a residential building. As one of the reduction method for improving the performance of light-weight impact noise, this study is focused on the load condition of floating layer over resilient material. We studied the correlation between the mass or load of the floating layer and the reduction of light-weight impact noise by experiments in reverberation chamber for testing the impact noise. The results show that the reduction of impact noise is improved by increasing the mass per unit area of floating layer until about $140kg/m^2$. But the reduction is not obvious by adding extra mass on the floating layer.

  • PDF

기후변화 대응 저에너지 건축물 조성을 위한 건축물 기화냉각시스템 에너지성능평가 연구 (A Study on the Energy Performance Evaluation of Building Evaporative Cooling System for Building Construction in Response to Climate Change)

  • 권기욱
    • 융합정보논문지
    • /
    • 제9권1호
    • /
    • pp.54-60
    • /
    • 2019
  • 최근 기후변화로 인한 외부 열환경이 악화되고 있으며, 이로인한 건축물에너지사용량이 상승하고 있다. 기후변화 대응형 건축물 저에너지 기술 성능평가를 위하여 Energy Plus를 활용하였다. 실험군 유형은 기본건축물(Control)과 기화냉각시스템(EMS)이며, 유형별 분석결과를 비교하였다. 에너지성능평가결과 냉방피크부하는 Control 대비 EMS에서 약 9% 이상 저감률을 보였다. 단위면적당 연간 냉방부하는 Control 대비 EMS에서 약 17% 이상 저감률을 나타내었다. 단위면적당 연간 에너지사용량은 Control 대비 EMS에서 약 10% 이상 저감률을 보였다. 따라서 건축물 에너지저감기술로 기화냉각시스템의 효과는 양호한 것으로 판단되었으며, 향후 기화냉각시스템의 분사량 및 이격거리에 따른 건축물에너지성능평가 연구가 진행되어야 할 것이다.

Modeling the Effects of Low Impact Development on Runoff and Pollutant Loads from an Apartment Complex

  • Jeon, Ji-Hong;Lim, Kyoung-Jae;Choi, Dong-Hyuk;Kim, Tae-Dong
    • Environmental Engineering Research
    • /
    • 제15권3호
    • /
    • pp.167-172
    • /
    • 2010
  • The effects of low impact development (LID) techniques, such as green roofs and porous pavements, on the runoff and pollutant load from an apartment complex were simulated using the Site Evaluation Tool (SET). The study site was the Olympic Village, a preexisting apartment complex in Seoul, South Korea, which has a high percentage of impervious surfaces (approximately 72% of the total area). Using the SET, the effects of replacing parking lots, sidewalks and driveways (37.5% of the total area) having porous pavements and rooftops (14.5% of the total area) with green roofs were simulated. The simulation results indicated that LID techniques reduced the surface runoff, and peak flow and pollutant load, and increased the evapotranspiration and soil infiltration of precipitation. Per unit area, the green roofs were better than the porous pavements at reducing the surface runoff and pollutant loads, while the porous pavements were better than green roofs at enhancing the infiltration to soil. This study showed that LID methods can be useful for urban stormwater management and that the SET is a useful tool for evaluating the effects of LID on urban hydrology and pollutant loads from various land covers.

대형 바렛말뚝과 현장타설말뚝의 하중전이특성 파악을 위한 재하시험 (Pile Load test on a Large Barrette Pile and a Bored Pile for the Identification of the Load Transfer Characteristics)

  • 한성길;박종관
    • 한국철도학회논문집
    • /
    • 제9권4호
    • /
    • pp.493-498
    • /
    • 2006
  • In this study, two large pile load tests were performed in the deep sand gravel deposit of Nakdong river basin so that the characteristics of the load transfer was identified. The fully instrumented rectangular barrette pile in the size of $1.5\times3.0m$ and the circular bored pile of the diameter 1.5 m were placed into the ground below 50 m. Under the applied loads of 2,400 tonf and 4,000 tonf, the test results of the load transfer showed the portion of 83% and 93% of the applied loads on the barrette pile and the bored pile, respectively, were supported by the skin friction along the pile shaft. It was revealed that the most of these skin friction mobilized in sand layer underlying clay layer having N-value more than 30 and that the friction per unit area of the bored pile was larger than the friction of barrette pile. However, if embedded in the stiff sand graval layer, the both piles were proven to be sufficient for using as the friction piles.

벼 도복 관련형질과 포장도복과의 관계 (Relationship Between Lodging-Related Characteristics and Field Lodging in Rice)

  • 임준택;권병선;정병관
    • 한국작물학회지
    • /
    • 제36권4호
    • /
    • pp.319-323
    • /
    • 1991
  • 벼의 도복에 관련하는 형질들의 포장도복과의 관련정도를 밝혀 벼의 이도복성육종의 기초자료를 제공코져 1900년대에서 1980년대에 재배 또는 육성된 10품종을 재배하여 실험한 결과를 요약하면 다음과 같다. 1 포장도복정도와 관련정도가 높은 형질들은 간장, 단위간하중(W/l), 단위 직경휨모멘트(W1/d), 도복지수(L), 하중비(W1/P), 임계도 복하중지수 (Ws$^2$/l$^4$)등 이었다. 2. 간장은 포장도복과 높은 상관(r=0.7607)을 보이나 간장만으로 품종의 도복정도를 판정하기는 미흡하였다 3. 측정의 난역도와 소모되는 시간을 고찰해 볼 때 도복저항성을 판정하는데 유용할 형질들은 간장, W/l, W1/d, Ws$^2$/l$^4$이었다. 4. 간경, 줄기단면적, 간벽의 두께, 줄기단면의 2차 관성 모멘트는 포장도복과 아무런 상관관계를 보이지 않았다. 5. 좌절강도(S)는 포장도복과 유의한 부의 상관 (r=-0.3986)을 보였다.

  • PDF

가스 포일 스러스트 베어링의 하중지지 성능 및 구동 토크에 관한 실험적 연구 (Experimental Study on the Load Carrying Performance and Driving Torque of Gas Foil Thrust Bearings)

  • 김태호;이태원;박문성;박정민;김진성;정진희
    • Tribology and Lubricants
    • /
    • 제31권4호
    • /
    • pp.141-147
    • /
    • 2015
  • Gas foil thrust bearings (GFTBs) have attractive advantages over rolling element bearings and oil film thrust bearings, such as oil-free operation, high speed stability, and high-temperature operation. However, GFTBs have lower load carrying capacity than the other two types of bearings owing to the inherent low gas viscosity. The load carrying capacity of GFTBs depends mainly on the compliance of the foil structure and the formed hydrodynamic wedge, where the gas pressure field is generated between the top foil and the thrust runner. The load carrying capacity of the GFTBs is very important for the suitable design of oil-free turbomachinery with high performance. The aim of the present study is to identify the characteristics of the load carrying performance of GFTBs. A new test rig for the experimental measurements is designed to provide static loads up to 800 N using a pneumatic cylinder. The maximum operating speed of the driving motor is 30,000 rpm. A series of experimental tests—lift-off test, static load performance test, and maximum load capacity test—estimate the performance of a six-pad GFTB, in terms of the static load, driving torque, and temperature. The maximum load capacity is determined by increasing the static load until the driving torque rises suddenly with a sharp peak. The test results show that the torque and temperature increase linearly with the static load. The estimated maximum load capacity per unit area is approximately 80.5 kPa at a rotor speed of 25,000 rpm. The test results can be used as a design guideline for GFTBs for realizing oil-free turbomachinery.

태양열 온실 난방에 대한 최척 집열 면적과 경제성 평가 (Optimum Collector Area and Economic Evaluation for the Greenhouse Heating)

  • 박이동;김규인
    • 태양에너지
    • /
    • 제2권1호
    • /
    • pp.49-58
    • /
    • 1982
  • Aim of this study was to obtain the heating performance and the economic evaluation on solar heating system for greenhouse which area of floor was $90m^2$. For heating performance effective solar energy for the greenhouse was compared with overall heating loads including coefficient of heat transfer and conduction. And the economic evaluation solar heating system was evaluated by comparison its initial investiment costing with oil saving cost. Initial investiment costing included collector cost, storage cost, piping cost, control system cost and miscellaneous costs which included pumps, motors etc. The contents of this study included the survey of climate conditions for solar heating, long-term collector performance and optimum collector area of solar heating system in existing greenhouse. The results are follows: 1. Average horizontal radiation during winter was $2,434Kcal/m^2$ day which was the highest value in this country, so the climate conditions of Suwon was suitable for solar heating. 2. Resulting calculation of the optimum collector area was $30m^2$ and the solar energy accounted for 30% of the overall heating load. 3. The capacity of storage tank required 60 liter per unit area ($m^2$) of solar collector.

  • PDF

차축의 중량 분포와 타이어의 공기압이 트랙터 작업의 연료 효율에 미치는 영향 (Effects of Distribution of Axle Load and Inflation Pressure of Tires on Fuel Efficiency of Tractor Operations)

  • 이진웅;김경욱;김동현;최규정
    • Journal of Biosystems Engineering
    • /
    • 제36권5호
    • /
    • pp.303-313
    • /
    • 2011
  • This study was conducted to investigate the effects of axle weight distribution and inflation pressure of tire on the fuel economy of tractors as well as operational range of tractor engine in terms of engine speed and power when a 4WD tractor of 38.2 kW rated power at 2500 rpm is used for plowing and flooded-field rotavating in paddy fields. (1) Plowing operation required an average engine power of 9.6~13.5 kW which equals 25~35% of rated PTO power. Engine speed ranged from 1,320.4 to 1,737.4 rpm, work velocity from 3.4 to 4.8 km/h, and fuel consumption from 3.2 to 4.2 L/h, respectively. (2) Flooded-field rotavating required an average engine power of 11.5~18.5 kW which equals 30~48.4% of rated PTO power. Out of this 6.2~12.2 kW was used for PTO power. Engine speed ranged from 1,557 to 2,067 rpm, work velocity from 2.5~5.4 km/h and fuel consumption from 3.2~5.5 L/h, respectively. (3) Axle weight distribution, inflation pressure of tire and moisture content of soil did not affect significantly the specific volumetric fuel consumption but affected significantly the fuel consumption per unit area of operation. Fuel savings amounted to 65% in plowing operation and 20% in flooded-field rotavating when the axle weight distribution and inflation pressure of tire were optimally adjusted. (4) Optimal adjustment of axle weight distribution and inflation pressure of tire are expected to save fuel consumption by 10~65% per unit area of operation in plowing and 10~20% in flooded-field rotavating.

철도 차량 화재시 화재강도 예측을 위한 연구 (A Study on the Prediction of Fire Load in case of a Train Fire)

  • 양성진;장정훈;강찬용
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.2101-2108
    • /
    • 2008
  • Most of train fires which occur in usual cases do not grow up significantly on a large scale enough to bring about casualties and harmful damages. However, the consequence of some train fire accidents can be devastating disaster so that it would be even recorded in history in unusual cases. Accordingly, such a probability of fire disaster cannot be ignored in aspect of the railway safety assesment. A scale of injury and damage is very difficult to predict and analyze. Because it is depend on various factors, i.e. fire load, burning period, facilities, environment condition, and so on. Thus, a prediction of fire load could be understood as a one methodology to estimate railway safety assesment. The summation method which is one of them is used to evaluate the overall fire load by assuming that sum of heat release rate per unit area or mass of each composite material equals the total. However, since the train fire is classified into a compartment fire in under-ventilation condition. The summation method do not estimate a fire load completely. In this journal, Various methods to predict fire load are introduced and evaluated. Especially the fire simulation tool FDS(Fire Dynamics Simulator)which is based on the CFD(Computational Fluid Dynamics) is introduced, too. Through the FDS simulation, numerical analyses for the fire load and flame spread are performed. Then, these results of the simulation are validated through the comparison study with the experimental data. Then, limitations and approximations including in simulation process are discussed. The future direction of research is proposed.

  • PDF

스파크점화기관에서 흡기제어 방식이 부분부하 성능에 미치는 영향(1) - 스로틀링과 마스킹의 비교 (Effect of Intake Flow Control Method on Part Load Performance in SI Engine(1) - Comparison of Throttling and Masking)

  • 강민균;엄인용
    • 한국자동차공학회논문집
    • /
    • 제22권2호
    • /
    • pp.156-165
    • /
    • 2014
  • This paper is the first investigation on the effect of flow control methods on the part load performance in a spark ignition engine. For comparison of the methods, two control devices, port throttling and masking, were applied to a conventional engine without any design change of the intake port. Steady flow evaluation shows that steady flow rates per unit opening area and swirl ratio are very low compared with the port throttling and saturated from mid-stage valve lift, however, swirl increases slightly as the lift is higher in case of 1/4 masking control. In the part load performance, the effect of simple port throttling on lean misfire limit expansion is limited and insufficient; on the other hand a masking improves the limit considerably without any port modification for increasing swirl. Also the results show that the intake flow control improves the combustion with following two mechanisms: stratification induced by the combination of the flow pattern and the fuel injection timing attribute to ignition ability and the intensified flow ensure fast burn. In addition fuel consumption reduces under the flow controls and the reduction rate is different according to the operation conditions and control methods. At the Stoichiometric and/or low speed and low load the throttling method is more advantageous; however vice versa at lean and high load condition. Finally, the throttling is more efficient for HC reduction than masking, on the other side the NOx emissions increase under the masking and decrease under the port throttling compared with conventional port scheme.